West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

(S)-2-(Pyrrolidin-2-yl)acetic Acid Hydrochloride

    • Product Name (S)-2-(Pyrrolidin-2-yl)acetic Acid Hydrochloride
    • Alias (S)-(-)-Pyroglutamic acid hydrochloride
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    707841

    Product Name (S)-2-(Pyrrolidin-2-yl)acetic Acid Hydrochloride
    Cas Number 112441-76-2
    Molecular Formula C6H12ClNO2
    Molecular Weight 165.62
    Appearance White to off-white solid
    Purity Typically ≥98%
    Melting Point 190-195°C (dec.)
    Solubility Soluble in water
    Smiles C1CCNC1[C@@H](C(=O)O)Cl
    Synonyms (S)-2-Pyrrolidineacetic Acid Hydrochloride
    Storage Temperature 2-8°C, protected from light and moisture
    Optical Activity Specific rotation [α]D +16° to +22° (c=1, H2O)
    Ph 1 Solution 3.0-4.0

    As an accredited (S)-2-(Pyrrolidin-2-yl)acetic Acid Hydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing A clear, labeled 5-gram amber glass bottle with screw cap, featuring Sigma-Aldrich branding, product name, and hazard warnings.
    Shipping (S)-2-(Pyrrolidin-2-yl)acetic Acid Hydrochloride is shipped in tightly sealed, chemical-resistant containers to prevent moisture and contamination. Standard shipping includes appropriate labeling for hazardous materials. The package is cushioned to avoid breakage, with a safety data sheet included, and complies with regulatory standards for chemical handling and transport. Temperature control may be applied if required.
    Storage (S)-2-(Pyrrolidin-2-yl)acetic acid hydrochloride should be stored in a tightly sealed container, protected from light and moisture, at 2–8 °C (refrigerator) in a well-ventilated, dry area. Avoid exposure to heat, acids, or incompatible substances. Ensure the chemical is clearly labeled and stored away from food and incompatible chemicals, following standard laboratory safety protocols.
    Free Quote

    Competitive (S)-2-(Pyrrolidin-2-yl)acetic Acid Hydrochloride prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    (S)-2-(Pyrrolidin-2-yl)acetic Acid Hydrochloride: Crafted for Precision in Chemical Synthesis

    From Our Factory Floor to Your Lab Bench

    Producing (S)-2-(Pyrrolidin-2-yl)acetic acid hydrochloride isn't just a technical procedure—it's the result of deliberate choices, careful controls, and lessons from a long road in organic synthesis. This molecule, known for its chiral pyrrolidine ring and hydrochloride salt form, answers to specifications that research chemists and drug developers expect. Our team doesn't treat it as another box to fill on the shipment log. The purity of the final product isn't a side effect; it's the result of an approach shaped by real conversations with scientists who care about more than the usual tick-box on a COA.

    Let's talk about what sets this compound apart. (S)-2-(Pyrrolidin-2-yl)acetic acid hydrochloride offers an (S)-enantiomer with a structure that opens the door for specialized peptide synthesis, chiral auxiliaries, and advanced pharmaceutical intermediates. Most of the demand comes from sectors that demand chiral integrity, reproducibility, and minimal batch-to-batch variation. In our production setting, controlling asymmetric induction has become an art as much as science; we owe much to feedback from partners in the pharmaceutical field who point out the pitfalls of racemization and the headaches caused by starting material impurities.

    Specification Built on What the Chemistry Demands

    The hydrochloride salt is not just a nice-to-have. It brings water solubility and makes handling safer—attributes that laboratories prefer when scaling asymmetric syntheses. Our lots offer assay results above 99% by HPLC, with chromatograms we review batch after batch. Impurity profiles aren't just regulatory obligations. We have seen how even minor ghosts in the profile complicate downstream steps: protecting group strategies can trip up, purification time balloons, or yields begin to slide. By setting upper limits for key impurities at 0.2% or below, we've helped more than a few collaborators streamline R&D projects with tight timelines.

    We insist on tight controls at every stage: starting with the optically pure precursor, careful control of reaction conditions, continuous in-process monitoring, and drying with conditions that avoid deliquescence or caking. Moisture content below 0.5% makes storage simpler and reduces risks in multi-step sequences, especially for those running peptide couplings that react poorly to stray water.

    Practical Benefits Forged from Experience

    We used to think all customers primarily cared about cost per gram. Over time, we've learned otherwise. For many, it's the work saved from not fighting off residual solvents, or avoiding re-crystallization after each delivery. Handling losses cut into precious research budgets faster than most realize. Chemists told us, “give us a product that doesn't need fixing,” so our drying protocols and packaging shifted. Double-bagged, nitrogen-flushed, and sealed with enough margin to withstand damp weather or rough transit, each pack undergoes visual inspection before shipment. We've watched enough powder changes in color or clump together from careless packaging to know the consequences hit hardest in the middle of time-limited research.

    Product consistency remains a recurring theme in feedback sessions. When a kilo order follows three months after a small lot, labs expect the same baseline for crystalline form and color. We compare FTIR, melting range, and NMR spectra for every scale-up. We've held back dispatching product when even a minor anomaly in spectral data turned up—missing a shipment makes for a hard phone call, but saving someone two weeks of troubleshooting earns genuine trust in the long run.

    Differentiating from Competing Products

    Not every variant of pyrrolidinylacetic acid meets this bar. Racemic versions and base forms sometimes cost less at first glance, but the chiral purity and work-up simplicity of our hydrochloride salt have shortened synthetic timelines for research clients on multiple continents. Laboratories running multi-step synthesis often report greater throughput with our material. Instead of the usual array of side-reactions and need for extra purification, we’ve seen yields hold steady between runs. For teams working on preclinical candidates, avoiding surprises can make the difference between project approval and an extended review.

    The (S)-enantiomer as the hydrochloride salt brings a clear advantage for those needing stereospecific substrate control or looking to avoid downstream chiral resolutions. While some markets tolerate mixtures, pharmaceutical researchers benefit from starting with a single, proven building block. Across our batches, we've held enantiomeric excess above 99%, and those numbers aren’t just marketing lines—they stand up to repeated scrutiny from client-side independent testing.

    Lessons from Production: Avoiding Pitfalls, Building Confidence

    Scaling asymmetric syntheses brings real challenges. Early attempts to make this compound at larger scales taught us to respect each stage: mixing order, temperature ramp rates, and even the glassware's dimensions matter more at scale than on paper. It’s not just about copying a lab notebook into a reactor; crystallization can stall, or unexpected by-products can slip through if reaction work-ups aren’t followed with focus.

    One key lesson came after we lost an entire batch to a slow pH adjustment in the work-up. The product turned gummy, extraction became unmanageable, and the team had to troubleshoot for days. Ever since, we’ve trained operators to work with deliberate, fine-tuned protocols, backed by real data—not just best guesses. Every production run gets documented, and when we tweak a parameter, that knowledge loops back into our SOPs.

    The market didn't ask us for traceability in the beginning, but a project for a regulated client made us rethink our approach. Now, every drum and bottle leaves our site with a history. We track every precursor lot, record critical instrumentation data, and save reference samples. If a shipment crosses an ocean, we keep backup documentation in case a container spends too long at customs or faces a stability check. These steps aren't the result of regulatory pressure alone. They come from seeing projects that teeter between success and setback for want of reliable documentation.

    What End Users Really Want from (S)-2-(Pyrrolidin-2-yl)acetic Acid Hydrochloride

    Nobody calls our office just to ask for a spec sheet. Instead, the conversations circle practical questions: “Will this batch dissolve as easily as my old supply?” “Are there any traces of heavy metals or residual solvents that will affect my next coupling?” “How long has this lot sat in storage?” To answer with more than words, we work with open data—sometimes, labs want to check the batch’s original NMR themselves. If any test result, even for a supposed trace contaminant, changes, we reach out before shipping a box.

    Pharmaceutical and biotech customers increasingly request transparent handling of documentation and compliance standards. More and more, we've seen requests for not just a COA, but a method of analysis, reference chromatograms, and even a chain of custody. This approach keeps us in step with what today’s R&D requires. Our internal audits focus on cross-checking not only instrument calibration records but also sample handling protocols. Sloppy documentation erodes trust, while thoroughness lets customers make decisions based on fact instead of faith.

    Some chemists are just starting with this moiety; others have run a hundred syntheses with it. We make time to support both. We share our protocols and offer insights about solvent compatibility, storage best practice, and safe disposal. No two research projects move at exactly the same pace, so we have learned to anticipate and adapt to order sizes. Our people pack one-gram vials as carefully as they load ten-kilo drums, knowing the experiment may hinge on a single reaction.

    Environmental and Safety Perspectives—Putting Experience to Work

    We have seen growing expectations for responsible handling and waste minimization. In the early days, disposal of acid chlorides and spent solvents barely registered in the conversation. Today, labs focus on minimizing exposure and simplifying end-of-life disposal. By choosing the hydrochloride salt, users benefit from both better control in aqueous work-ups and reduced handling hazards. We design our process to cut down on halogenated solvent use and keep waste acids separated for easier downstream treatment.

    Solid handling reduces volatilization risks. We pack the compound in containers that resist puncture and shielding from light, because improper exposure can degrade even a good product. By testing each shipment for stability under normal and adverse storage, and by training our logistics crew, we’ve cut complaints over lumpy or discolored material almost to nothing. Our staff have learned the hard way that an overfilled drum or pinhole-sealed bag can undo weeks of careful work.

    Compliance does not stop once the batch leaves our gates. Each lot comes with recommendations for safe handling, spill management, and emergency protocols. To keep our own staff protected, regular risk reviews have become habit. We analyze not just incident logs, but near-misses—any spill, mix-up, or failure to follow the checklist leads to process tweaks and updated training. These real-world measures allow us to offer more than reassurance: the safety record makes a difference when clients need confidence in long-term partnerships.

    Application Insights—Beyond the Brochure

    This molecule often finds its way into the hands of medicinal chemists charting new routes to CNS agents or amino acid analogs. It serves as a chiral auxiliary or intermediate for active pharmaceutical ingredient synthesis. Some research teams opt for the racemate to save money, but they often circle back to the chiral form for better selectivity and fewer process impurities.

    We see the demand spike ahead of preclinical runs or screening campaigns in medicinal chemistry. The compound’s solid handling and ability to form stable intermediates cut down unnecessary repetition when scaling from grams to hundreds of grams. Custom requests come in for altered particle size, reduced moisture, or further purification. We listen, and the feedback shapes our next production run.

    Long-term partners often share their workarounds and innovations. Some improved peptide coupling efficiency by re-suspending our product in specific buffers. Others discovered that controlling local pH while dissolving sped up downstream cyclization. We've incorporated those findings, not just for one-off requests, but as part of our core recommendations for future users.

    Comparisons—Lessons from the Marketplace

    Competitors sometimes offer lower prices or claim higher throughput with bulk intermediates. Over years, customers have explained their choices in clear terms. Hidden costs—lost yields, extra days spent re-checking purity, or unexpected regulatory issues—often erase any initial savings. More academies and research consortia choose suppliers based on word-of-mouth, testing the consistency, and cross-referencing with internal benchmarks.

    The difference in handling between our hydrochloride salt and the free acid version is not subtle. The salt form minimizes dusting, dissolves in a broader range of lab solvents, and ships with an extended shelf life. Because we produce all material on-site, we control every source, every critical step—from raw materials through to packing lines. Supply interruptions have not been a concern, because buffer stock gets maintained, and any notification for upcoming changes lands with weeks’ notice.

    Skepticism keeps us sharp. Many customers run their own tests: they check for IR fingerprints, residual solvent by GC-MS, and sometimes even commission a full mass balance. We encourage it. Our doors are open to inquiries and technical audits, and we share non-sensitive root-cause analyses if ever an issue is flagged. Tackling outliers and acting on feedback led us to remove unnecessary stabilizers, tighten packaging, and improve documentation clarity.

    Quality Without Shortcuts—A Manufacturer’s Word

    Behind each kilo of (S)-2-(Pyrrolidin-2-yl)acetic acid hydrochloride, there’s a team that insists on real accountability. A few early mistakes—missed batches, suboptimal purities, or unexpected re-tests from critical partners—taught us that quality is not a checkbox. Every SOP review, batch log, and training session owes its existence to those setbacks.

    We maintain open channels—our formulation team, quality control laboratory, and packaging crew loop feedback back to R&D. Audit trails run both internal and external, with access to historical data for regulators and client-side reviewers. If a trend toward out-of-specification parameters emerges, containment and corrective action follow, always in plain language, with technical justifications based on data and experience.

    We know who uses our products and the pressures on their daily work. Those relationships matter. We don’t outsource production, and we don’t white-label for resellers, as this lets us stand up for our materials at every audit and troubleshoot issues without intermediaries clouding communication. Traceability, repeatability, and hands-on support have earned us long-term collaborators who value predictability over hollow promises.

    Feedback Shapes the Future

    Our best improvements have come from honest, sometimes hard conversations. One research group flagged higher-than-expected sodium content, traced to an upstream neutralization step. We rebuilt part of the process, swapped reagents, and managed to recover the original performance—saving headaches across multiple customer projects. Each audit or QC comment gets recorded and, if warranted, becomes a new checkpoint in the process chart.

    We stay engaged past the transaction. If a customer faces issues in scale-up or encounters an unexpected stability problem, our technical staff dig in, review the workflow, and offer solutions drawn from actual production experience. Those exchanges serve as labs for further improvement. Product integrity wins loyalty, but so does human engagement and practical know-how.

    Shaping Reliability, One Batch at a Time

    Through years of hands-on production, close collaboration, and transparent problem-solving, our (S)-2-(Pyrrolidin-2-yl)acetic acid hydrochloride stands as a result of deliberate choices and learning. We have shaped it to address real-world scientific and operational needs, building on the input, trust, and plainspoken advice of the chemists who rely on our work. Our offering goes beyond the certificate—informativeness, trust, and unwavering standards have shaped every step from our factory floor to your experiment.