|
HS Code |
576446 |
| Chemical Name | Picolinimidamide Hydrochloride |
| Molecular Formula | C6H8ClN3 |
| Molecular Weight | 157.60 g/mol |
| Appearance | White to off-white solid |
| Solubility | Soluble in water |
| Cas Number | 3104-68-1 |
| Melting Point | 225-230°C (decomposes) |
| Storage Temperature | 2-8°C |
| Purity | ≥98% |
| Synonyms | Picolinamidine hydrochloride |
| Iupac Name | pyridine-2-carboximidamide hydrochloride |
| Smiles | C1=CC=NC(=C1)C(=N)N.Cl |
| Usage | Intermediate in organic synthesis |
| Stability | Stable under recommended conditions |
As an accredited Picolinimidamide Hydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | A 5-gram amber glass bottle labeled "Picolinimidamide Hydrochloride, Chemical Grade," featuring hazard icons, Sigma-Aldrich branding, and batch details. |
| Shipping | Picolinimidamide Hydrochloride is shipped in a tightly sealed container to prevent moisture absorption and contamination. It is handled under ambient conditions, with MSDS documentation included. Standard chemical shipping protocols are followed, with labeling for laboratory use only. Temperature control is not typically required unless otherwise specified by the manufacturer. |
| Storage | Picolinimidamide Hydrochloride should be stored in a tightly sealed container at 2-8°C (refrigerated), protected from light and moisture. Ensure the storage area is well-ventilated and chemicals are kept away from incompatible substances. Use appropriate secondary containment and follow all standard laboratory safety protocols as provided by Sigma Aldrich, Merck, or TCI Chemical Grade Safety Data Sheets (SDS). |
Competitive Picolinimidamide Hydrochloride prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Producing Picolinimidamide Hydrochloride takes more than just technical skill. At our facility, every batch follows a clear pathway: precise selection of inputs, controlled reaction stages, and consistent post-processing all combine to produce a compound that meets high expectations for chemical purity and performance. As a chemical manufacturer with years spent on the shop floor and in the lab, seeing the process through from start to finish brings a unique perspective on the science behind every order.
Manufacturing this compound, we rely on our understanding of 2-picoline-based chemistry. The hydrochloride salt form brings improved solubility in aqueous environments, making it a preferred choice for researchers and process chemists. During purification, the product’s stability stands out. Even small fluctuations in pH or temperature can undermine the compound’s quality, so we apply rigorous controls at each stage. The outcome is a finely granular white powder, showing uniformity of particle size and reliable handling characteristics—details that make a difference when scaling from the lab bench to full-scale synthesis.
In our line, the model corresponds directly to batch identity and traceability. Rather than producing generic intermediates without oversight, we track every lot with its own dedicated process log and analytical fingerprint. Our Picolinimidamide Hydrochloride consistently reaches a purity grade of ≥98%, with tightly held limits on moisture and residual solvents, thanks to iterative optimization of each production stage. Overseeing the operation, I often take samples directly from the line for HPLC and NMR analysis—an extra step, but one that lets us catch any small deviations before product packing.
Specifications do more than populate a list; they reflect what matters to customers. Our chemical comes as a crystalline or microcrystalline powder, with manageable bulk density so that dosing remains accurate across scales. We ship in bulk drums and laboratory bottles, using materials proven compatible with this compound to keep degradation in check during transit and storage. Stability studies inside our own warehouse and in external labs have shown consistent shelf life for up to two years under standard dry, cool conditions.
Fine chemical manufacturing connects science with practical needs. In the case of Picolinimidamide Hydrochloride, its broad adoption in synthetic organic chemistry reflects reliable reactivity and manageable risk profile. Research groups working on heterocyclic compounds favor this reagent for its capacity to introduce nitrogen-containing motifs under mild conditions. Our own experience supplying pharmaceutical labs confirms its effectiveness in peptide coupling reactions and functional group transformations, particularly where reaction selectivity dictates a narrow process window.
Routine use in research is one thing; the real test comes in upscaling. We’ve worked closely with specialty chemical producers shifting from 10-gram R&D lots to 10-kilo pilot batches. The same batch-to-batch consistency we monitor internally helps our industrial customers translate their lab findings into pilot and commercial runs. Container type, storage protocol, and handling guidelines that we provide come out of these collaborations, shaped by real experience rather than pure theory.
Comparing one chemical with another on paper rarely tells the full tale. In the synthetic lab, factors like solubility, reactivity, byproduct profile, and safety in handling all become real through daily use. One reason customers stick with our Picolinimidamide Hydrochloride has to do with purity—impurities such as free amines or alternate salts can compromise reaction yield or clog up downstream separations. From early feedback, we learned that process chemists appreciate not having to spend extra time troubleshooting side reactions or variable exothermic behavior. Tighter control upstream means less downstream headache.
Other available amidines offer broader pH ranges or different salt forms. We’ve tested several, both in-house and through feedback from partner labs. Sodium or potassium salts introduce their own interference in certain catalyst-driven reactions, while non-hydrochloride forms sometimes suffer from unpredictable hygroscopicity, drawing in moisture and degrading before use. Hydrochloride’s greater shelf stability, and our focus on filtration and drying, remove this frustration. Our product dissolves rapidly in both aqueous and select organic solvents, helping users cut out the need for pre-treatment steps or extended mixing times.
Many handling guidelines read as strict instructions, but they often stem from avoidable mistakes. Years of making, storing, and shipping this compound have shown us where real risks lie. Inhalation risk stays low when handling properly bagged and sealed powder, and the hydrochloride form reduces dusting. Our facility’s experience with pneumatic loaders and local extraction points keeps airborne particulates below regulatory thresholds. We recommend similar setups to any operation scaling beyond bench scale, based on observations in our own workspace. Clean-out operations between batches use only compatible solvents—never water exposure alone, as it can cause partial dissolution and unwanted caking.
One memorable episode: a customer reported unexplained melting in storage. After cross-checking conditions, we traced the issue to a shipping container with faulty seals. Moisture ingress led to clumping, which flagged the need for improved liners and moisture barrier packaging. Later tests confirmed that our upgraded containers kept the compound free-flowing, even with weeks spent in high-humidity transit. Problems like these shape every tweak to our process; we invest in resolving common pain points because we’d rather avoid headaches in our own warehouse or anyone else’s.
Some research teams focus on theoretical yield above all else, but working on the ground reveals other priorities. The best process isn’t just about chemical transformation—it’s about controllability and predictability. With Picolinimidamide Hydrochloride, we see top yields when reactions run slightly below ambient temperature and use dry atmospheres. Scale-up brings its own challenges: agitation, solvent volume, and vessel shape all play a role. On our manufacturing line, we’ve documented the impact of mixer speed and cooling rate, building a knowledge base that we share with our users on request.
We support custom requests, such as alternative particle size cuts or pre-packed reaction kits for academic collaborations. These adaptations come straight from conversations with scientists who needed a different flow, not from reading between the lines in anonymous market reports. Talking directly with production chemists or technical directors, we can adjust drying methods, filtering protocols, or package size—each change tied to supporting a specific process case or helping reduce waste. Every adaptation adds value for both sides, and such feedback keeps flowing back into our main product line.
In any modern chemical manufacturing environment, compliance shapes every stage of production. We track material inputs and outputs closely, monitoring emissions and waste streams for alignments with environmental standards. This compound presents fewer disposal difficulties than other nitrogenous reagents, as its aqueous waste stream neutralizes safely with minimal downstream hazardous byproducts. Past routine inspections by regulatory auditors confirm we are following all necessary protocols, including traceability, documentation, and evidence of routine testing. Extra documentation may sound tedious, but our experience shows it builds trust, especially for users in regulated pharmaceutical sectors.
Shipping regulations changed recently, so we reviewed labeling and packaging one more time, ensuring no steps fall short. International customers, especially, appreciate prompt turnaround on COAs and the level of detail we provide beyond the basic data panel. Meeting these requirements not only avoids costly mistakes but also means our product arrives at each destination ready for immediate use. We work with forwarders experienced in chemical logistics—lessons learned from shipments delayed or mishandled in less specialized channels have convinced us of the importance of close oversight here.
Many of our most enduring innovations have come from ongoing partnerships. Instead of stopping at simple transaction-level service, we engage with universities and industrial labs running new reaction methodology or process scale-ups. Sharing firsthand application data, troubleshooting synthesis troubleshooting, and responding to technical inquiries often leads us to tweak our process or packaging. Whether it’s substituting inert liners in response to a particular solvent system, or providing pre-ground material for high-throughput screening, these modifications spring from a real understanding of the work our chemical supports.
Supporting our customers isn’t just about filling orders. Technical service teams keep in close contact post-shipment, addressing any issues and logging unusual results. By pooling these experiences, we continuously refine both our process and the information we provide, feeding back into quality initiatives that support everyone who uses Picolinimidamide Hydrochloride. External audits and collaborative process mapping with partners often identify new areas for efficiency or product improvement; these insights reveal as much about ongoing industrial trends as any trade show or market report.
Having handled many amidine-class reagents over time, the differences in performance go deeper than just structure or analytical data. Picolinimidamide Hydrochloride’s robust shelf stability, low dusting, and minimal sensitivity to ambient humidity set it apart from sodium, potassium, or free-base alternatives. This results in practical time savings when batching out material, reduces the risk of operator error, and simplifies validation for those in tightly regulated spaces. Feedback from pharmaceutical pilot plants highlights the value of being able to switch from small-scale test runs to large-batch production without major changes in process controls or documentation.
Technical literature often emphasizes theoretical reactivity, but the hands-on technician values reliability above all. During repeat preparation of nitrogen-containing heterocycles, for example, inconsistent behavior across suppliers or salt forms can halt development for days. Our investment in consistency—lot-to-lot, shipment-to-shipment—ensures steady output with fewer surprises. This reliability, more than any paper spec, leads to lasting partnerships with our long-term customers.
Evaluating new production technologies and greener methodologies plays an increasing role in guiding our company strategy. Several times, we’ve piloted adjustments to the isolation stage to cut solvent volumes or recover wash streams for re-use, improvements that both reduce costs and environmental impact. Regular benchmarking against industry standards motivates us to try new equipment and monitor for bottlenecks, drawing on the experience of both our own staff and our customers’ feedback.
Growth in demand is driven by innovation on all sides. R&D labs working on new pharmaceuticals or specialty polymers place new demands on reagent quality, consistency, and technical support. These evolving expectations push us to reinvest in both staff training and process controls, keeping us at the front of a crowded market without sacrificing reliability or safety.
For those exploring Picolinimidamide Hydrochloride as a reagent in research or for scaling up production, real results often come down to choice of supplier and the relationship built around that transaction. Our door stays open to questions, requests for technical data, and problem-solving discussions drawn from direct manufacturing experience. The knowledge we’ve built through years of hands-on production sets the foundation for meaningful collaboration—every lesson learned in the plant or lab becomes part of how we operate, improving products not in theory, but in daily practice.