West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

N-Succinimidyl 4-Fluorobenzoate

    • Product Name N-Succinimidyl 4-Fluorobenzoate
    • Alias SFB
    • Einecs 251-608-5
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    817725

    Productname N-Succinimidyl 4-Fluorobenzoate
    Casnumber 63599-71-1
    Molecularformula C11H8FNO4
    Molecularweight 237.18
    Appearance White to off-white solid
    Purity Typically ≥98%
    Meltingpoint 74-77°C
    Solubility Soluble in DMSO, DMF, and slightly in methanol
    Storagetemperature Store at 2-8°C, protect from moisture
    Synonyms SFB; 4-Fluorobenzoic Acid N-Succinimidyl Ester
    Smiles C1=CC(=CC=C1C(=O)OS(=O)(=O)CN2C(=O)CCC2=O)F
    Inchikey GJUZVXNQFOMSGF-UHFFFAOYSA-N

    As an accredited N-Succinimidyl 4-Fluorobenzoate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing N-Succinimidyl 4-Fluorobenzoate (Sigma-Aldrich) is typically packaged in a 1g amber glass vial with a screw cap and label.
    Shipping N-Succinimidyl 4-Fluorobenzoate is typically shipped by Sigma-Aldrich, Merck, or TCI as a solid in tightly sealed containers, under ambient conditions. It is packed to prevent moisture and light exposure. Standard shipping uses ground or air services, following chemical safety regulations, and includes appropriate hazard labeling for laboratory use.
    Storage **N-Succinimidyl 4-Fluorobenzoate** should be stored in a cool, dry, and well-ventilated area away from light and moisture. Keep the container tightly closed and store at 2-8°C (refrigerated). Protect from heat, incompatible substances, and sources of ignition. Use only in a chemical fume hood and avoid direct contact. Follow standard laboratory safety procedures and institutional guidelines.
    Free Quote

    Competitive N-Succinimidyl 4-Fluorobenzoate prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    N-Succinimidyl 4-Fluorobenzoate: Building a Reliable Backbone for Precision Labeling

    Why We Make This N-Succinimidyl 4-Fluorobenzoate

    After years of working with peptide and protein chemists, we've learned how much reliability and consistency matter in active ester linkers. N-Succinimidyl 4-Fluorobenzoate (SFB, also known as p-FB-OSu) stands as a key tool in the hands of professionals working on bioconjugation, radiolabeling, and developing targeted pharmaceuticals. We synthesize SFB with attention to purity, confirmed by rigorous batch controls and advanced chromatographic checks. Our approach has always put real-world lab outcomes first, rather than chasing paperwork or spec sheet perfection.

    What Sets Our SFB Apart

    Producing SFB requires sharp process control. Each batch must maintain high levels of purity and low moisture content, because even small contaminations affect reactivity with amine groups on biomolecules. We routinely observe that SFB batches with trace levels of hydrolyzed byproducts or unreacted fluorobenzoic acid yield unpredictable conjugation ratios. Through better process streamlining and solvent choice, we’ve suppressed these byproducts to background. Years of collaboration with university radiochemistry labs and diagnostic reagent producers have sharpened our production decisions—lessons straight from users seeing differences between batches from various sources.

    Our manufacturing rests on high-purity starting 4-fluorobenzoic acid and fresh N-hydroxysuccinimide. We never shortcut the reaction time or skip re-crystallization steps. Unlike some batches on the open market—originating from traders with murky supply chains—our product registers clean signals on NMR and HPLC, with matching mass spectra. We know deviations at the level of hidden impurities can trigger false positives in protein assays or lead to side-reactions in solid-phase peptide synthesis.

    SFB is More Than a Reagent—It’s an Enabler

    People often overlook how backbone esters like SFB impact the success rate of bioconjugation. Suppose you’re building a PET tracer for protein imaging. If the SFB fails to react fully or leaves residual NHS, the final tracer loses purity, affects shelf-life, and wastes precious isotope. The difference becomes clear when a radiolabeling reaction completes in minutes, with a clean product, versus neighbors struggling through repeated purification and low labeling yield. Working closely with technical teams in diagnostic startups, we've seen well-produced SFB shave days off new method development, because people no longer need to work around purification oddities or batch-to-batch inconsistency.

    Several customers used to report that random SFB batches, including some globally prominent brands, created unpredictable background signals in antibody conjugation and small molecule radiochemistry. After switching to our material, they saw cleaner baseline readings and more efficient amine coupling. These results often matter more than theoretical purity numbers.

    SFB in Practice: Applications that Count

    The most common demand for SFB lands squarely in the field of radiochemistry and site-specific bioconjugation. NHS esters, especially those with aromatic rings and halide substitution, have been the preferred toolbox items for introducing prosthetic groups into peptides, proteins, and antibodies. The active NHS ester group enables selective coupling—mainly targeting free amino groups on lysine side chains. The presence of the para-fluoro moiety allows downstream 18F-labeling, a crucial function in clinical PET imaging agents.

    Researchers working on antibody-drug conjugates or tracer molecules appreciate a stable, thoroughly tested source of SFB. The molecular weight, solubility profile, and stability—they all matter, but above all, the real difference emerges in hands-on conjugation yield and downstream purification. Mass spectrometry of final conjugates tells the story: residual side-products dramatically drop out when the source SFB is clean.

    Beyond radiolabeling, teams tackling bioactive surface modification or building new diagnostic reagents integrate SFB because it brings versatility without compromising downstream biological activity. We’ve worked with companies working at the intersection of chemistry and biology—hearing feedback about reaction times, byproduct cleanup, and how difficult it can be to get consistent results from the commodity market.

    Model and Specifications, Rooted in Experience

    Our catalog references SFB as Model SFB-418. We keep structural characterization data and batch certificates on file for every lot. Chemists often tell us that the difference between theoretical and delivered material becomes clear only after testing on their own systems. So we don’t just claim high HPLC and NMR purities; we back up our claims with side-by-side demo packs so labs new to our material can test hard endpoints. For typical syntheses, our users dissolve SFB in dry organic solvents—usually acetonitrile or DMF. The product remains free-flowing, not lumpy or oily, which speeds weighing and transfer.

    Our average reported shelf life at 2–8°C in sealed amber glass bottles runs two years without significant hydrolysis. Stability gets confirmed by re-checking key parameter values—no reliance on theoretical “stability under storage” text. We ship in practical pack sizes—grams up to several hundred grams—so researchers can avoid repeated freeze-thaw cycles, which ruin less stable SFB.

    What Compromises Show up in Other SFB Sources

    The market for activated esters remains crowded by intermediaries, but few take feedback from the bench. Common shortcuts include skipping recrystallization or using partially dried starting material. These choices save days in-house, but user results suffer the consequences. Our plant ran several head-to-head blind tests with leading brands. The findings: Non-recrystallized material often clumps, absorbs atmospheric water faster, and forms visible particulate when dissolved. This leads to unexpected side reactions during coupling, and can even block columns during purification runs.

    Other sources sometimes use lower-purity 4-fluorobenzoic acid, which introduces faint but problematic aromatic impurities. These signals almost disappear into the baseline on simple HPLC but emerge clearly in sensitive LC-MS methods. If you’re making clinical trial materials or diagnostic kits, those hidden impurities turn into failed validations.

    Use in Labeling—Lessons Learned from the Lab

    We keep hearing user stories about batch-to-batch surprises from bulk SFB traders—labeling yields drop, unexpected peaks pop up in analytical runs, or the product cakes after weeks on the shelf. Our SFB holds line on amine reactivity and stays dry and powdery, even after months at 2–8°C. Several university peptide labs sent back notes showing near-quantitative yields from tiny coupling reactions—tracer experiments with only micrograms of precious protein. A senior radiochemist reported that our SFB, when used for 18F labeling of a peptide tracer, gave sharper, more concentrated radiolabel than three other test samples.

    Protein scientists working on bioactive surface modification, especially those optimizing site occupancy for lysine or N-terminal modifications, shared their own take: “No more gambling on activation; we just dissolve, react, and purify, and it runs smoother than ever.” That resonates with what we see in routine pilot runs.

    Reducing Waste: Practical Approaches in SFB Handling

    From experience, minimizing SFB waste boils down to keeping it dry and tightly capped, never leaving open bottles under lab humidity. SFB responds fast to moisture, and hydrolyzes back to 4-fluorobenzoic acid, losing its coupling activity. By keeping pack sizes small and providing custom aliquoting, we help customers avoid opening the same bottle day after day. Nobody benefits from oversized bottles that encourage repeated moisture exposure.

    Another waste-reducing tactic: pack each bottle under inert gas, followed by rigorous testing before shipment. We run accelerated shelf-life studies on retained samples to catch any surprises that might escape standard wet chemistry checks.

    Key Structural Features: Not All Fluorobenzoate Esters Are Equal

    SFB carries a fluorine atom at the para position, making it distinct from other NHS-benzoate esters. That halogen enables fast 18F labeling without need for additional prosthetic modification—critical for PET tracer work, where short half-lives place a premium on fast, selective chemistry. The NHS group provides high amine selectivity, coupling efficiently to lysine residues or N-terminal groups at pH 7–8. SFB’s amine selectivity outperforms other aromatic ester choices, including non-fluorinated NHS benzoates.

    Teams working in biopharmaceuticals and diagnostics repeatedly highlight how even small changes in reagent structure ripple through downstream activity and purity. We choose this structure because it brings reactivity, selectivity, and labeling performance without excessive side product formation or harsh conditions. The 4-fluorine not only aids downstream radiolabeling, it also slightly increases electron-withdrawal, making amine coupling more efficient.

    Our Partnership with Researchers: Transparency and Real Support

    We run our production lines with the same focus as the scientists we supply—never letting short-term batch yield pressure override user outcomes. Every lot includes certificate data drawn straight from analytical runs, not generic summary numbers. Technical support responds directly to synthetic and analytical questions; we value lab feedback. Suggestions lead to direct process tweaks, either in drying, bottling, or shipment conditions. Unlike trader-sourced lots, we maintain clear, documented supply chains—customers never risk mixing unknown batches or losing track of batch origin.

    We also believe trust is built by sharing obstacles as well as successes. If a customer’s method turns up new side signal or a coupling step fails, we investigate both in-house and at the user site, seeking experimental solutions together.

    The Difference: Batch Consistency Backed by Us

    Industry-wide, users report that major brands, and especially grey-market SFB, show wider spec drift from batch to batch. One customer shared a data log showing melting point deviation of over 3°C between two consecutive orders from a large distributor. Our internal QC records, going back five years, show a spread of less than 0.5°C from batch to batch. This level of control didn’t come from luck. Before scaling production, we worked through dozens of theoretical and experimental purification strategies—some that didn’t pay off until scale-up showed real cost and performance reward.

    Consistency matters most for users running regulated methods. We built our QC documentation to line up with pharma and IVD requirements from day one. All key reference standards are validated in-house. This means users know their SFB’s certificate isn’t based on third-party claims from a sourcing agent, but on direct batch-specific test data.

    Supporting the Lifecycle: From Synthesis to Application

    Working across the supply and research chain, we see SFB’s value in both basic and applied science. Collaborations with analytical chemists, radiolabeling labs, and diagnostic kit developers generate direct feedback loops—leading us to add reactivity checks, establish new purity markers, and develop documentation suites that speak to technical and regulatory needs alike. Our SFB batch records and user notes form a real-world knowledge base that shortens client R&D cycles.

    We adapted our fulfillment approach in part from conversations with researchers complaining about unreliable shipping conditions—hot climates, border holds, and rough warehouse storage. Vacuum-sealed glass, tamper-proof seals, and cold-chain packaging help ensure each pack arrives unchanged from when it left production.

    Selecting Reliable SFB for Critical Applications

    On-the-ground stories back up our insistence on defined source control. A PET radiochemist described failed labeling runs caused by SFB picked up from a bulk reseller—it arrived yellowed and sticky, infuriating the team and sinking a grant deadline. By switching over to direct-from-manufacturer supply, they met project requirements, finished on time, and saw better downstream results.

    For teams building diagnostic conjugates, minimizing trace reactants and maximizing reproducible coupling are mission-critical. They cited fewer sample rejections, better pass rates in QC, and less trouble from analytical “ghosts"—forensic-level confidence only comes from trustworthy material.

    Innovation: Small Wins that Add up in Process Chemistry

    Continuous process improvement runs as a thread through our manufacturing philosophy. We’ve worked with chemists to pinpoint micro-scale adjustments in drying protocols, select higher surface area reaction vessels, and fine-tune recrystallization temperature ramps. Every tweak, large or small, arose from solving real problems in the field—either ours, or those of the researchers we work with. No change makes it through if it doesn’t improve user outcomes. We track how process changes show up in the finished product—every customer report adds to our feedback loop.

    Some of our most successful innovations—better desiccant blends, improved sealing techniques—came straight from customer pain points. This grounds our approach and sets a real-world rhythm to technical development, rather than speculative features nobody ends up needing.

    The Future of SFB: Supporting Next-Gen Diagnostics and Therapies

    As more therapies and diagnostics move toward targeted, personalized delivery, the need for validated, clean, and reproducible reagents grows. SFB occupies a crucial spot for linking labels, drugs, and imaging agents to proteins and small molecules. Teams working on next-generation cancer diagnostics and bioorthogonal labeling already rely on properties like predictable coupling and reactivity.

    Requests for custom grade SFB—meeting ever-stricter regulatory bar or supporting new conjugation chemistries—keep surging. We stand ready by running pilot batches, supporting validation work, and shifting lot production from R&D into manufacturing as soon as a process proves its value.

    Real Reliability in Every Pack

    N-Succinimidyl 4-Fluorobenzoate stands as more than a background reagent; it represents a partnership between manufacturer and user based on shared, results-driven experience. By centering what matters to chemists—reactivity, consistency, minimal waste, authentic batch data—we keep adjusting, refining, and delivering a material that drives both innovation and day-to-day research. The trust built through repeat performance and technical transparency means SFB delivers on its promise—helping projects succeed, letting scientists focus on discovery, and supporting underserved corners of research and development.