HS Code |
251858 |
| Chemicalname | Dichloroglyoxime |
| Casnumber | 5341-58-8 |
| Molecularformula | C2H2Cl2N2O2 |
| Molarmass | 156.96 g/mol |
| Appearance | Solid, usually crystalline |
| Color | White to off-white |
| Meltingpoint | 174-177°C |
| Solubilityinwater | Slightly soluble |
| Boilingpoint | Decomposes before boiling |
| Density | 1.87 g/cm³ |
| Odor | Odorless |
| Storageconditions | Keep container tightly closed and store in a cool, dry place |
| Stability | Stable under recommended storage conditions |
| Synonyms | Dichloro-1,2-dioximeethane |
As an accredited Dichloroglyoxime factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Dichloroglyoxime, 25g, packaged in a sealed amber glass bottle with tamper-evident cap, labeled Sigma Aldrich analytical grade. |
| Shipping | Dichloroglyoxime is shipped in tightly sealed containers to prevent moisture and air exposure. Packaging complies with chemical safety regulations, typically labeled as harmful or irritant. Ground transportation is preferred for stability; air shipment requires additional documentation. Carriers adhere to hazardous materials protocols when shipping from suppliers like Sigma Aldrich, Merck, or TCI. |
| Storage | Dichloroglyoxime should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area away from heat sources and incompatible materials such as strong acids and bases. Protect from light and moisture. Store at room temperature or as specified by the manufacturer's guidelines (Sigma-Aldrich/Merck/TCI). Ensure proper chemical labeling and follow all safety protocols for handling hazardous chemicals. |
Competitive Dichloroglyoxime prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every chemical tells a silent story of its creation. In our production plant, Dichloroglyoxime stands out for its clarity, reliability, and function. Years of delivering this compound have taught us not just its technical features, but also the real needs of the researchers and industrial clients who depend on the purity and predictability of each batch.
Working with Dichloroglyoxime starts with respect for its roots—built on the glyoxime backbone, but modified with chlorine atoms to deliver a niche tool for analytical chemistry and specialty synthesis. Some folks weigh options between dichloro derivatives and simpler glyoximes for basic oxime reactions, but the difference is more than two atoms: it touches on how complex metal ions bind, the detection limits in analysis, and the tailorability for complex syntheses. Our process keeps this in mind from the first raw material audit through every finished batch, with our chemists physically tracking purity and consistency before shipment.
Creating Dichloroglyoxime is no routine batch preparation. It’s a hands-on job. We source clean precursors, keep temperature and pH carefully stable, and run frequent spot checks. Our team tests each lot for active ingredient concentration and checks clarity and color using straightforward, time-proven methods. We know that even small contaminants or variable water content can throw off results in analytical labs. With each kilogram that leaves our reactors, our chemical team signs off on more than data—they sign off on their time and understanding.
Dichloroglyoxime brings value where selectivity matters. While closer relatives like plain glyoxime are well known for nickel and palladium detection, dichloroglyoxime brings sharper sensitivity when distinguishing certain lesser-known transition metals or when researchers face complex mixtures. Some chemistries call for this precise interaction; others lean toward more generalized oximes where cost or supply are a driver. The steady interest from universities and manufacturers in North America and Europe guides our small refinements. We’ve run side-by-side tests against a range of glyoximes and noticed fewer false positives on our refined dichloro variant, especially when it comes to trace heavy metals.
Lab staff and industrial managers care less about gloss and more about “what does this chemical do differently, and does it save time, lower risk, or generate cleaner results?” Dichloroglyoxime often makes the difference where speed of crystallization and selectivity of metal binding matter. For processes that involve high-throughput detection, such as large-scale water testing or pharmaceutical quality assurance, even slight improvements can amount to fewer repeats and lower staff fatigue. Our purity control process is based on actual performance, not just a number on a sheet. The specification follows usage, not marketing promises.
In the field, it pays to get the format right. Many of our regular clients came to us with problems sourced from inconsistent granule sizes or unpredictable solubility profiles found in some broader-market alternatives. Our answer? We standardize the solid material to match the dissolve rate required in modern wet-lab protocols. Each lot’s melting point—and its consistency—is checked and logged for real-world performance. Moisture content, in particular, receives attention, as we know storage conditions can make or break a compound like this.
Every chemist who has tried to push the sensitivity of a colorimetric assay knows the struggle: stick with traditional glyoximes, or try to go further with derivatives? Dichloroglyoxime provides an answer in scenarios where higher selectivity and cleaner color endpoints are non-negotiable. Our own in-house trials, mirrored by feedback from academic researchers, show that the additional chlorination tightens up the metal chelation range and sharpens analytical endpoints. This means fewer ambiguous results in tests for trace metals—especially those where environmental safety or process quality are on the line.
Some commercial offerings of glyoxime-type compounds are easy to blend, but batch-to-batch differences often crop up, leading to revalidation of protocols in regulated industries. By keeping our production vertical, controlling the inputs, actively monitoring critical chemistry steps, and packing the final product attention to detail, we keep those annoying disruptions off our clients’ plates. Our plant supervisors say, “You can see the transparency in the color—you feel it in the filtered powder texture. That’s not something you measure with a machine alone.”
Field tests and bench scientists push our product hardest. Feedback loops matter. We hear most from environmental analysts, pharmaceutical quality technicians, and research teams focused on precise metal quantification. They don’t want the surprises that come from an off-spec batch: cloudy solutions, inconsistent hues, poor reproducibility. The way we approach making this product—hands-on, empirically tuned, and always with direct feedback—makes that level of trust possible.
One practical example came from a municipal water laboratory struggling to detect low concentrations of nickel amidst interfering substances. Their transition from traditional glyoxime to our dichloro grade removed false negatives that appeared during seasonal water chemistry shifts. It was not a paper exercise—it was a field fix, grounded in the hands-on knowhow of both sides. Similar results have come from academic research into metal ion transport and bioinorganic chemistry, where the sharp delineation provided by dichloroglyoxime allows more confident analysis.
Some users ask if switching from dioxime or standard glyoxime causes complications in protocols. Our experience says that the substitution is smooth, as long as users engage with the slight differences in reactivity and coloring mechanism. We provide guidance based on historical casework, not just generic adjustment tables, and routinely discuss any critical points with repeat clients before large-scale rollouts.
In the chemical supply market, plenty of choices exist: diglyoxime, dimethylglyoxime, plain glyoxime. These all serve specific roles. The dichloro variant stands apart for its engineered selectivity and color response. Where traditional glyoxime sometimes reacts too broadly—catching metals outside the desired target set—our dichloro synthesis lets lab workers pull clearer boundaries. For metal-specific assays, especially those tied to regulatory requirements or cutting-edge research needing distinct detection thresholds, this compounded precision creates a real edge.
Industrial users frequently mention that process controls run smoother; less time is lost cross-checking unanticipated side reactions in multi-metal streams. The dichloro product strains out more interferences in raw water or effluent streams—giving control analysts measurable peace of mind. Research staff appreciate the user-tested protocols we’ve compiled over time from actual client experiences. These are not generic tips: they are insights rooted in day-to-day lab and plant work.
Shipping a sensitive reagent like this adds responsibility on both producer and customer. We handle every batch with a focus on chemical stability: packaging materials resist moisture and light, and each batch is checked before it leaves for even small deviations in weight or consistency. Our plant's safety culture brings practical handling knowledge—engineers and packers receive regular update briefings on best practices, always informed by evolving regulations and on-the-ground observation of chemical behaviors through seasonal temperature shifts.
End users receive recommendations based on our daily work with the product: quick resealing of containers, dry storage away from heat and direct sun, common-sense use of gloves and ventilation. Over decades of production, we’ve encountered nearly every storage mistake and have built up a detailed, experience-backed body of advice for avoiding downtime, off-spec reactions, or wasted material. Whether a client is storing half a kilo for routine use or scaling up for a research deployment, our team knows what protocols keep things running at their best.
Direct access to the manufacturer carries weight for users. Our lab support lines ring in the same building where batches are made: the same chemists reviewing test sheets take the troubleshooting calls. If a lab faces an unexpected shift in color response, uncertain solubility, or trouble matching previous literature data, our technical staff work through the issue with practical solutions, not canned scripts. Sometimes it’s as simple as adjusting solution strength or tweak to protocol, sometimes it requires batch-specific calibration. Our feedback cycle is rooted in ongoing cooperation.
We know there’s a temptation to treat chemical vendors as just sources of material. In reality, the best results happen when both sides share experience. Lab teams update us about any odd or borderline results, and we’ve modified our checks in direct response. This responsive manufacturing loop not only lifts confidence in our dichloroglyoxime, it also allows us to keep fine-tuning key specs that save time and improve outcomes for clients doing critical work.
There is no shortcut to the habits built from making, testing, and shipping a tight-spec product like dichloroglyoxime over many years. Issues arise: a shift in raw material quality, a new regulation from a key market, a scientific advance that puts new demands on sensitivity. Each challenge that arrives at our plant doors gets met by experience, not by guesswork or paperwork shuffling. We adapt formulation and logistics to match these new realities, using measured batch adjustments and, at times, input from long-term clients who spot field-level trends before the trade journals catch on.
Uninterrupted supply becomes crucial during periods of market volatility. By anchoring production locally and refusing to outsource to low-control environments, we’ve kept delivery schedules steady, even when transport networks break down or raw chemical prices swing. We plan capacity increases based directly on user feedback, not theoretical five-year projections from analysts. This focus on actual order history and client relationships keeps our dichloroglyoxime shipments predictable and free of unwelcome surprises.
In the real world, companies and research teams want plain evidence of chemical quality — not just gloss or persuasive claims. That’s why we run open challenge testing: offering reference samples, supporting side-by-side assay validation, and inviting customers to compare outcomes against their incumbent suppliers. This approach has led to rapid adoption in labs and plants frustrated by inconsistent imports or white-label intermediaries. We make our test methods clear, describe limits, and invite outside validation.
Laboratory clients gain by being able to see full batch data, including simple direct assays and physical checks. Our policy has always been to supply data that’s understandable, with real reference points, not just numbers buried in spec sheets. If a user wants to run their own method side by side with ours, we facilitate — nothing gives us faster feedback when small issues appear, and nothing wins customer loyalty like transparent engagement.
While chemical supply can often feel like a one-way street, we have found the greatest long-term quality improvements come from real conversations with users at every skill level. From experienced research chemists to QA/QC operators running routine batch tests, each piece of feedback has led us to make incremental refinements that cannot be replaced by lab automation alone. We ask practical questions, respond with specific suggestions, and track both the successes and hiccups back to production to avoid repeat problems.
For example, a team working with new alloy materials recently reported an unexpected spectral interference. Our technical leads used their input to modify a portion of our synthesis sequence, shaving down a minor byproduct that was invisible in standard tests but showed up under higher-sensitivity conditions. This collaborative approach means each problem shared by the user base fortifies both the next batch and the industry as a whole.
Looking ahead, dichloroglyoxime will keep evolving. Regulation keeps tightening in critical industries; researchers keep pushing the boundaries with advanced instrumentation. We’ve already begun investing deeper in batch traceability, advanced purity screens, and greener synthesis routes that will keep environmental impact and downstream residues as low as possible. Our production team has started collaborating with outside experts to sharpen up screening capabilities for emerging trace contaminants, aiming to maintain a trusted supply even as analytical standards rise.
Feedback from new applications—such as next-generation thin-film technologies and specialized catalysis—adds a fresh dimension to our R&D pipeline. Each emerging use case receives genuine attention; we prototype pilot-scale batches and seek real-world validation before offering any changes for broad adoption. It’s this cycle, grounded in the reality of manufacturer-to-end-user relationships, that keeps our dichloroglyoxime relevant and reliable.
Every container of dichloroglyoxime represents not just a chemical, but a history of focused production, trial, error, adjustment, and learning. For clients who need more than generic statements or mass-market reliability, direct engagement with the actual manufacturing team translates to tangible outcomes: predictable results, fair troubleshooting, and a path toward ever-improving quality. From input selection to batch output, our process remains steady—chemistry led by experience, informed by feedback, and anchored in the daily demands of real-world users.