HS Code |
151522 |
| Chemical Name | Coenzyme Q9 |
| Molecular Formula | C54H80O4 |
| Molecular Weight | 785.2 g/mol |
| Appearance | Yellow to orange crystalline powder |
| Solubility | Insoluble in water, soluble in organic solvents |
| Melting Point | 52-54 °C |
| Cas Number | 303-98-0 |
| Function | Electron carrier in mitochondrial electron transport chain |
| Synonyms | Ubiquinone-9, CoQ9 |
| Biological Role | Antioxidant and cellular energy production |
| Stability | Stable under recommended storage conditions |
| Storage Conditions | Store in a cool, dry place, away from light |
| Source | Naturally present in animal and plant cells |
| Spectral Data | Characteristic UV absorption at 275 nm |
| Usage | Biochemical research, dietary supplements |
As an accredited Coenzyme Q9 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Coenzyme Q9 from Sigma Aldrich is supplied in a 100 mg amber glass vial with a tamper-evident screw cap and clear labeling. |
| Shipping | Coenzyme Q9, from Sigma Aldrich, Merck, or TCI (chemical grade), is shipped in tightly sealed, inert containers to protect against moisture, light, and air. It is typically transported under ambient or cool conditions, with appropriate hazard labeling, in compliance with international chemical shipping regulations to ensure product integrity and safety. |
| Storage | Coenzyme Q9 (Sigma Aldrich/Merck/TCI Chemical Grade) should be stored at –20°C, protected from light and moisture in a tightly sealed container. It is sensitive to oxidation; therefore, minimize exposure to air. Store in a dry, cool, and well-ventilated area. For best results, aliquot to avoid repeated freeze-thaw cycles. Follow manufacturer’s recommendations for safe handling and storage. |
Competitive Coenzyme Q9 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
At our plant, the process of synthesizing Coenzyme Q9 stands as a focal point in developing reliable nutritional and biochemical ingredients. Crafting this molecule, which bears the chemical name ubiquinone-9, involves more than skill with fine chemicals. Our work with Coenzyme Q9 comes from years of research and direct manufacturing challenges, which have shaped the quality and consistency we’re now able to achieve.
Coenzyme Q9, or C59H90O4 by molecular structure, presents as a yellow-to-orange crystalline or powdery solid. The production line maintains purity above 98% using high-performance liquid chromatography. Shelf stability factors impact this molecule in ways different from its close cousin, Coenzyme Q10. During scaling, we found Q9 slightly less stable toward light and elevated temperatures, which led us to implement specific packaging and storage controls that help customers avoid unexpected losses. For long-term storage, cold chain management reduces oxidative degradation and preserves functional value.
Decades ago, researchers established that Q9 fulfills a role similar to Q10 by participating in electron transport and energy transfer inside mitochondria. Yet the presence of Q9 is dominant in some animal models, notably rodents, where it serves as the principal quinone. One recurring question from our clients—especially those working in preclinical research and animal nutrition—focuses on whether Q9 or Q10 serves the organism best. Our quality control data shows that batches of Q9 produced with tight impurity limits produce clearer biological readouts in animal studies.
Any manufacturer applying Q9 in vivo or ex vivo models recognizes the benefit of molecular uniformity. Formulation scientists and feed manufacturers, especially those designing rodent-specific diets, rely on Q9 for correlation with natural metabolic profiles. Products intended for animal feed are supplied in batches ranging from 100 grams to 20 kilograms, packaged under nitrogen. Years of feedback from research labs have led us to shift our output range to suit the volume and usage frequencies common in this space.
We’ve confronted the physical quirks of Coenzyme Q9 in every scale-up exercise. Unlike Q10, Q9 demonstrates a slightly lower melting point—around 46–49°C by our daily QC checks. Handling in humid, warm environments introduces caking risks; the practical solution involves tight humidity and temperature controls from the drying step onward. Our team also found that Q9’s solubility varies more depending on the solvent system. In ethanol and ether, it dissolves uniformly, but in water solubility stays negligible. This guides our users toward non-aqueous media for formulations, especially for injectable or encapsulated products.
Reported degradation comes almost exclusively from two sources: light and oxidants. We manufacture under amber lighting, and end users often request shipments in light-blocking containers. Oxidative stress on Q9 remains measurable above certain oxygen partial pressures, prompting many clients to choose packaging with oxygen scavengers for sensitive formulations. Over the years, more clients have moved toward single-use sachets, which have practically eliminated end-use degradation complaints.
The similarities between the two coenzyme Q types can mislead buyers. Both play roles in mitochondrial electron transport and ATP synthesis, but the different side-chain lengths—nine isoprenoid units in Q9, ten in Q10—give rise to clear differences in biological context and stability. Coenzyme Q10 dominates in human tissues, so most pharmaceutical supplements use Q10. In contrast, our clients in animal studies, veterinary science, or rodent model optimization continue to demand Q9 for more accurate metabolic mirroring. Substituting Q10 for Q9, or vice versa, does not replicate results in vivo, as downstream metabolism and tissue uptake diverge.
Our lot release specifications account for these critical differences by testing the side-chain distribution in every batch, using proprietary standards developed over years of side-by-side reference studies. A common pitfall in the market stems from manufacturers who treat Q9 and Q10 as interchangeable; we routinely see this lead to inconsistent data or failed animal experiments. By sticking with Q9 where target organisms demand it, researchers obtain cleaner endpoints and reproducible data sets.
One lesson we’ve learned about the ingredient supply chain is the risk of cross-contamination and batch variability. Small differences in source materials or minor deviations in process can introduce impurities that are hard to trace but easy to measure in sensitive cell culture or in vivo studies. Our internal audits regularly trace raw material origins and track environmental controls at each batch stage, as these steps have the greatest impact on finished Q9 quality. Labs and feed manufacturers working at the edge of detection limits rely on clean starting materials; the burden falls on the producer to prevent invisible noise.
In the past, several clients arrived after receiving underperforming Q9 from non-specialist brokers. We rebuilt confidence by sharing production records, traceable batch histories, and actual analytical reports. There’s a marked difference in perceived trust between a chemical manufacturer and a general distributor; transparency on method, source, and trace metal screening makes up the basis of long-term relationships in this segment. By opening up to regular third-party audits, we confirm that our product matches or exceeds published monographs.
Formulators and research scientists describe Q9 as a “supply chain weak point” due to its low global production volume and the challenge of producing high-purity material without long supply disruptions. We’ve responded by investing in local capacity and redundant warehousing. Every year, we analyze customer feedback on product performance and stability, translating those insights into process tweaks. Years ago, packaging shifts—like the move from clear to amber containers, and from reusable bulk to single-serve packets—directly tracked requests from researchers concerned with light and moisture.
Overly standardized information rarely answers the practical questions customers raise. In real-world use, technical literature on Q9 tends to skip the challenges with formulation compatibility and ingredient stabilization. For example, we identified that incorporating Q9 directly into certain oily matrices can help deliver the active ingredient in animal feed, but that process also accelerates peroxide formation if the feed lipids are not fully refined. We now include peroxide value monitoring as a standard part of our quality system.
We have also worked closely with veterinary supplement producers, who often blend Q9 with vitamins and trace minerals. Our R&D group continuously screens for adverse ingredient interactions—one example being soft gelatin capsule leaks related to higher moisture load, which we fixed by introducing a humidity-limiting step during filling. Most of these improvements originated from open communication with end users rather than from laboratory conjecture.
Ongoing challenges in Q9 production boil down to two main factors: impurity control and product integrity across the distribution chain. To address these, our plants run multi-point impurity screens—focusing on residual solvents, heavy metal traces, hydroperoxides, and polymerization byproducts. Impurities can enter Q9 at each homogenization or extraction step, so we doubled down on critical process control points. This means every batch includes full-release testing, including area normalization for impurities below 0.1%, which research groups flagged as disruptive to their high-sensitivity datasets.
Product stability during shipping continues to concern both us and our customers. Shipment routes that expose Q9 to temperature excusions or direct sunlight almost guarantee product loss, so our distribution partners receive clear guidelines: always use thermal insulation and avoid direct sunlight, even during short transfer periods at airports or warehouses. We routinely monitor returned and customer-used samples for degradation products; over years of trend analysis, these tests have pinpointed weak links in several major logistics providers’ handling. Our team worked directly with those companies to implement process changes.
Down the line, R&D turns to antioxidant package development as one main area of innovation. We currently test combinations of natural tocopherols, chelators, and inert gas purging to preserve Q9 in matrix blends. Early data from ongoing shelf-life trials suggests the right additive package can double the usable life of Q9 in animal feed blocks, which cuts costs for large-scale breeders. The more we share these findings with our customers, the faster we see adoption and real-world impact.
Every region approaches Q9 regulation with a unique focus. In some regions, the molecule still falls under controlled assessment for animal feeds; elsewhere, Q9 appears in industry compendia as a permitted additive for research. By staying ahead of shifting regulatory concerns, we support customers through documentation, impurity proof packs, and periodic compliance updates. Our regulatory team joins working groups and industry associations to help shape and interpret requirements. These behind-the-scenes efforts pay off whenever a researcher or formulator faces a new compliance test.
Technical documentation alone cannot replace actual performance data. We publish anonymized stability summaries and impurity profiles in regional languages for customers to share with their own auditors. Industry feedback from pilot tests, especially in veterinary and research settings, circles back into process and documentation improvements. We respond directly to trending issues, such as concerns over persistent organic pollutants. For instance, routine dioxin screening became a permanent fixture in our batch release process after the veterinary regulatory authorities flagged potential contamination routes.
Many in our industry take technical bulletins as the final word on Q9, but for us, each batch is more than a certificate of analysis. Manufacturing practice shapes the actual experience customers have with Q9—whether that’s adjusting a feed formulation, resolving an unexpected degradation, or pushing forward scientific discovery. Our team spends equal time with documentation, production optimization, and hands-on troubleshooting; lessons on the line become improvements in each bottle or carton shipped.
Open lines of communication with scientists, feed formulators, and purchasing specialists moved us away from a one-size-fits-all approach toward batch-tailored support. From immediate technical troubleshooting to strategizing long-term ingredient supply, every process step and quality standard reflects a mixture of hard science, real-world feedback, and manufacturing know-how.
Through hands-on experience, batch-by-batch improvement, and close collaboration with customers, we deliver Coenzyme Q9 designed for performance in the field, lab, or production floor. Every lesson learned improves what we send out the door—whether that’s a case destined for a veterinary trial or a kilo for a rodent study. Emphasis on transparency, technical dialogue, and reliable follow-through defines our way of supporting Q9 users and their projects.
Major breakthroughs hinge on small details, and the challenge of producing truly consistent Q9 highlights that point. We continue to invest time and technical capital in solving real-world problems tied to Q9 application, formulation, and stability, shaping not just our own production line but the standard practices of those who trust us with their hardest projects.