|
HS Code |
379997 |
| Chemical Name | 4-Fluorohippuric Acid |
| Cas Number | 70256-08-1 |
| Molecular Formula | C9H8FNO3 |
| Molecular Weight | 197.16 g/mol |
| Appearance | White to off-white solid |
| Melting Point | 174-176 °C |
| Solubility | Soluble in water, ethanol |
| Purity | Typically ≥98% |
| Storage Conditions | Store at room temperature, away from moisture and light |
| Synonyms | N-(4-Fluorobenzoyl)glycine |
| Inchi | InChI=1S/C9H8FNO3/c10-7-3-1-6(2-4-7)9(13)11-5-8(12)14/h1-4H,5H2,(H,11,13)(H,12,14) |
| Smiles | C1=CC(=CC=C1C(=O)NCC(=O)O)F |
As an accredited 4-Fluorohippuric Acid factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 4-Fluorohippuric Acid, 5g, supplied in a sealed amber glass bottle with Sigma-Aldrich labeling, chemical grade, safety instructions included. |
| Shipping | 4-Fluorohippuric Acid (chemical grade; Sigma Aldrich/Merck/TCI) is shipped in tightly sealed containers, protected from moisture and light. It is transported under ambient conditions as a non-hazardous laboratory chemical, complying with relevant safety and regulatory guidelines. Shipping documentation includes material safety data sheets (MSDS) for safe handling upon receipt. |
| Storage | 4-Fluorohippuric Acid should be stored in a tightly closed container, in a cool, dry, well-ventilated area, away from sources of ignition and incompatible substances. Protect from moisture and direct sunlight. Recommended storage temperature is 2–8°C (refrigerated). Ensure proper labeling, and keep away from food and drink. Follow all relevant safety guidelines and consult the Safety Data Sheet (SDS) for details. |
Competitive 4-Fluorohippuric Acid prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Manufacturing 4-Fluorohippuric Acid has taught us the nuances of working with fluoroaromatic compounds and their interplay in research and industry. This chemical, often found by its model number FHPA-99, continues to capture interest due to its specific chemical properties, reliability in synthesis, and adaptability in various laboratory and production settings. The finished product shows a clean, white to off-white solid, with purity levels that reach greater than 99%, supported by HPLC analysis. The melting point consistently falls between 199°C and 202°C, and each production batch passes stringent controls to keep impurities at the lowest levels possible. We stick to these high standards because research requires accuracy—the smallest deviation can throw off experimental data or downstream processes.
One of the regular uses for 4-Fluorohippuric Acid comes from metabolic and toxicological studies, often as a metabolite of fluorinated aromatic compounds or as a bio-marker in biological matrices. Its structure allows chemists and researchers to trace fluorinated compounds inside biological systems, providing a reliable signal for HPLC, LC-MS, and GC-MS analysis. We first saw growing demand from pharmaceutical development teams who value the stability and detectability of the fluorinated benzene ring. Unlike non-fluorinated hippuric acid, the presence of fluorine introduces a distinct fingerprint, improving sensitivity and selectivity in assays. Researchers can differentiate it from naturally occurring metabolites, reducing background noise and increasing confidence in their reports.
Beyond tracking and detection, 4-Fluorohippuric Acid often appears as an intermediate or reference standard. The NH-CO-CH2-Ph-F linkage remains robust under a range of reaction conditions, so formulators look at it when building or breaking down complex molecules. It dissolves well in polar organic solvents like DMSO and methanol at room temperature, making sample preparation straightforward, though attention to pH and temperature is necessary to prevent hydrolysis. Stability during storage and handling ranks high on our list, and that's why we anchor our batches with moisture content below 0.5% and package exclusively under dry, inert atmospheres. We learned early on that neglecting these details leads to partial hydrolysis, batch inconsistency, and rejections from quality teams on the customer side.
Customers ask about purity almost every week. Our reality in production is a constant push to keep impurity levels very low—below 0.2% for fluorinated aromatic by-products and trace metal residues near detection limits. Analytical chemists can spot even small peaks from residual starting materials, and every rejected batch becomes both a financial loss and a blow to our team’s pride. Early process optimization involved improving crystallization protocols and filtration steps. The scale-up from pilot reactor to full-sized glass-lined reactors brought new hurdles. Particle aggregation became a challenge because batch cooling rate and solvent choice impact the crystalline form. Consistent particle size ensures every batch behaves the same: no clumps, no uneven dissolution, and clean, quick filtration in user labs. Years of experience taught us to never overlook sieving and blending after drying—one stray oversized particle will show up on a competitor’s QA report.
Unlike traders or brokers, manufacturers face the factory floor: re-crystallization at the wrong temperature brings morphological changes, and the wrong solvent blend can cause occluded impurities. We deal with the engineering realities; filtration under vacuum, careful control of solvent volumes, and full documentation of each mother liquor disposal. We avoid solvents suspected of leaving extractable residues, and batch release only happens after a three-point check with our internal reference standards. We have invested in automated HPLC detectors and cleanroom weighing stations for good reason. Specifications published online come alive only through strict daily routines, hourly log sheets, and relentless re-training.
Comparing 4-Fluorohippuric Acid to other common derivatives—such as 2- and 3-fluorohippuric acid, or even parent hippuric acid—raises some vital distinctions known best to those who handle these materials in quantity. Positioning of the fluorine atom in the para position affects polarity, reactivity, and even odor during the drying step, something not always flagged in literature. Para-fluorinated compounds like ours demonstrate more predictable retention and separation profiles on reverse-phase columns than ortho or meta analogs, making them favorites for high-throughput screening or calibration curve generation. Synthetically, para-substitution often means less steric hindrance, translating to higher yields and fewer by-products during the acylation step. In contrast, ortho- and meta- versions sometimes generate side-products due to increased ring activation, with difficult-to-remove impurities that complicate purification. Anyone sourcing these reagents for sensitive endpoints will notice fewer column re-packs and less downtime when working with the para version.
4-Fluorohippuric Acid’s fluorinated aryl structure impacts not just the analytical detectability, but also biological fate and clearance rates. In pharmacokinetic modeling, para-fluorinated hippuric acid traces behave differently in renal clearance compared to their non-fluorinated or isomeric relatives. Customers in bioanalytical labs often send feedback on how smoothly our FHPA-99 performs in urinalysis panels without the erratic peaks or tailing seen with some commercial alternatives.
Producing high-purity 4-Fluorohippuric Acid in bulk takes constant attention to safety. Our operators deal with mixed solvent systems, anhydrous conditions, and periodic batch exposure to HCl gas during some syntheses. We learned quickly to double-check all glovebox overpressure valves and to maintain rigorous colorimetric monitoring for acid vapors during filtration. Exposure to fluorinated aromatic dust raises unique respiratory risks, which prompted installation of point-source aspiration and continuous real-time dust monitoring. Our team’s health and safety records depend on clear communication—every vessel cleaning regime and every PPE check gets signed off, no shortcuts taken. Small lapses can cause skin or respiratory irritation and cross-contamination, which only persistent training routines and clear process signage can prevent.
Storage conditions also factor into long-term stability. Beyond basic dry, cool storage, we recommend sealed containers with desiccant packs and opaque outer packaging. UV light and humidity lead to slow degradation, and we have documented the changes in HPLC profiles after accidental light exposure during storage. By adapting packaging line practices—moving filling and sealing to reduced-light rooms—we avoid quality dips caused by exposure during final packaging steps. These small manufacturing nuances make a difference when end-users report consistent results over multiple orders or flag new product inconsistencies.
Manufacturers see the compound from a different angle than traders or resellers. We invest in process development, handle kilo and multi-kilo lots, and scrutinize every batch for compliance—all with the end-user’s application in mind. For 4-Fluorohippuric Acid, we know exactly which parameters matter: solvent system residue, crystallinity under specific drying regimens, and how minor shifts in reaction temperature translate to batch yields. By sourcing our own raw materials and validating each process tweak, we can back every certificate of analysis with real data and lived experience. This perspective helps us anticipate regulatory questions or custom documentation needs that resellers can’t address on short notice.
End-users sometimes request alternative particle sizes for automated dispensing or wish to trial higher-concentration stock solutions for specific assay protocols. We take these requests as the starting point for continuous process improvements. Only by running extended stability studies and collaborating with user labs have we optimized our drying and grinding steps. That’s a distinct advantage of manufacturing expertise—reacting fast to feedback without awaiting direction from a supply chain middleman. Another ongoing area of feedback involves the total organic content and extractable non-polar residues, both easily missed unless processes run under predictive analytics and regular validation checks.
Stringent QC protocols define our approach. Each lot of 4-Fluorohippuric Acid undergoes multi-point examination: HPLC for purity and related substance content, NMR for structural validation, and low-level water content by Karl Fischer titration. We calibrate each instrument weekly, use traceable reference standards, and run parallel blanks to eliminate ghost peaks or false positives from our glassware and columns. We track the full genealogy of each batch, from raw acid chloride procurement to final labeling and sealing. Analytical run sheets accompany every batch, and customers with advanced detection setups rely on these detailed profiles for internal audits or regulatory submissions.
Traceability also extends beyond analytical results. Our scale-up found repeatable yields and impurity profiles only after methodically recording and analyzing hundreds of batch records. Relating back deviations in purity or yield to changes in supplier lots, reaction temperatures, or staff shift changes led us to rework early training routines. The correlation between operator technique and end-product consistency never fails to surprise new hires. By keeping full audit trails and retaining split samples, we support any post-market queries or root-cause investigations with real evidence. The investment in record-keeping pays dividends during customer audits and bolsters trust with long-term R&D partners.
Environmental responsibility has become a bigger factor in the fine chemical sector. 4-Fluorohippuric Acid production brings its own share of waste challenges—mixed halogenated solvent waste and acidic aqueous streams, both needing responsible management. Over several years, we have replaced some legacy solvents with lower-toxicity or recyclable alternatives and installed solvent recovery units to handle large-scale reprocessing. Process teams run periodic reviews aimed at waste minimization, water recapture, and reduction of unnecessary energy use during extended heating or drying steps. Some of these changes mean greater up-front costs, but our long-term partnerships recognize the value of continuous sustainability improvement. Customers have begun to request environmental impact disclosures, and our transparent reporting style has opened up several collaborative projects with multinational research consortia.
We also field more requests for documentation on residual solvent levels, heavy metal content, and compliance with European REACH protocols. Our experience with in-house testing has helped us respond quickly, providing not just summary certificates but detailed chromatography and method validation results. We conduct regular audits of our own supply chain, and we support customer-led site visits for ongoing qualification. The role of process chemistry teams in meeting new regulatory frameworks can’t be overstated—the data and best practices developed in our plant feed directly into global safety and sustainability targets.
Direct manufacturing experience grants us a better understanding of the everyday challenges faced by researchers. Some customers need gram-scale pure standards, others manage bioreactor scale and require custom packaging or specific solvents systems to speed up downstream processing. Each request highlights different priorities: stability during shipment, minimization of shipping residues, and compliance with advanced analytical requirements. We adapt by offering customized solution concentrations, packaging suited to cold-chain logistics, and technical support that reflects years of firsthand troubleshooting.
Feedback from the field often brings up the realities of method transfer between institutions. What runs smoothly in one analytical lab might return inconsistent results after a change in column brand or mobile phase purity. We support method troubleshooting and cross-validation by keeping reference samples from every batch and providing spectral fingerprints tailored to actual user protocols. By engaging with scientists at every level, from undergrads to senior lab managers, we learn what truly matters in practice: sample availability, documented performance, and consistent delivery, not just a line on an invoice. Our production insight lets us address technical questions without deferring to remote technical staff, a tangible benefit for time-critical projects or regulatory filing deadlines.
Years producing 4-Fluorohippuric Acid taught us that quality comes from accumulated process wisdom, daily attention to detail, and willingness to rethink established protocols. Market needs evolve—today’s niche metabolite can turn into tomorrow’s diagnostic standard, bringing with it requests for new purity thresholds, faster delivery, or alternate packaging. Only by embedding continuous improvement into production and testing steps do we stay ahead. Documented SOPs mean little unless they match daily practice and prompt honest feedback from every shift and every operator. Our experience producing this compound means we can recognize minor process drifts before they snowball into off-spec product or lost client trust—something that comes only from hands-on experience, not generic training or trading office know-how.
Looking ahead, we plan to keep evolving our synthesis and quality systems, investing further in automation and green chemistry approaches. Matching the real needs of researchers with the realities of industrial manufacturing keeps us focused, responsive, and ready to support not just the current uses of 4-Fluorohippuric Acid, but the new applications we expect innovation to uncover. Every lot released represents a practical measure of our commitment to reliability, safety, and open collaboration with the worldwide scientific community.