HS Code |
855946 |
| Chemical Name | 4,4-Difluorocyclohexanol |
| Molecular Formula | C6H10F2O |
| Molecular Weight | 136.14 g/mol |
| Cas Number | 17623-94-4 |
| Appearance | White to off-white solid |
| Melting Point | 62-66 °C |
| Density | 1.25 g/cm³ (estimated) |
| Solubility In Water | Slightly soluble |
| Smiles | C1CC(CC(C1)O)(F)F |
| Inchi | InChI=1S/C6H10F2O/c7-6(8)3-1-2-5(9)4-6/h5,9H,1-4H2 |
| Storage Conditions | Store at room temperature, in a tightly closed container |
As an accredited 4,4-Difluorocyclohexanol factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 4,4-Difluorocyclohexanol, 25g, supplied in a sealed amber glass bottle with tamper-evident cap, labeled by manufacturer. |
| Shipping | 4,4-Difluorocyclohexanol is shipped in tightly sealed containers, compliant with hazardous material regulations. Packaging ensures protection from moisture and physical damage. The product is labeled with appropriate chemical hazard warnings and handled by certified carriers. Shipping typically complies with IATA, DOT, and IMDG guidelines, ensuring safe, regulated transport to the destination. |
| Storage | 4,4-Difluorocyclohexanol should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area away from direct sunlight and sources of ignition. Keep it separated from incompatible substances such as strong oxidizers and acids. Store at room temperature and ensure proper chemical labeling. Follow local safety regulations and refer to the manufacturer’s Material Safety Data Sheet (MSDS) for detailed guidance. |
Competitive 4,4-Difluorocyclohexanol prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Stepping into the production line for 4,4-Difluorocyclohexanol offers a look at the blend of craftsmanship and control required to create specialty fluorinated alcohols for modern industry. This compound, with the CAS number 1512-40-7, stands out for a reason: fluorine atoms change the dynamics within a cyclohexanol ring, resulting in properties that lend themselves to applications most chemists rarely see from non-fluorinated analogs.
We source raw materials with high purity, paying strict attention to the water content and the chain of custody for each lot. Unlike more commonly handled mono-fluorinated cyclohexanols, a double fluorine substitution at the 4-position changes everything—from boiling point to reactivity. Our reactors handle this transformation under carefully controlled temperature and pressure, using catalysts that maintain efficiency while limiting side reactions. This approach keeps by-products low, and the distillation step makes a clear difference in the quality of the final lot.
Production always begins with a commitment to quality over quantity. Our standard batch of 4,4-Difluorocyclohexanol, under model designation DFCX-44H, consistently achieves a purity of over 98% by gas chromatography. Visual clarity and minimal water are essential, since these parameters directly affect downstream synthesis performance. Molecular formula C6H10F2O, molecular weight 136.14 g/mol, with melting point typically near 46°C and boiling point around 188°C. What matters on our end are not just numbers, but how those values translate to predictability in customers’ labs.
As we see across a range of customer applications, swapping in 4,4-Difluorocyclohexanol instead of non-fluorinated or differently-fluorinated cyclohexanols changes reaction rates, stability, and final product performance. The specific positioning of both fluorine atoms at the 4-position gives this molecule a unique hydrogen bonding pattern and alters its interaction with nucleophiles. It’s not just a subtle tweak—fluorination at these locations resists metabolic breakdown, which polymer chemists and pharmaceutical developers exploit. While some users come to us after trial runs with other cyclohexanols, they notice that impurities from certain suppliers can scuttle weeks of research. That’s why we stress traceability and batch-specific analytical data.
Walking through the facility, one meets researchers looking for that perfect cyclohexanol backbone to test in new fluorinated polymers, liquid crystals, and advanced materials. The alcohol group on the ring brings reactivity, and the double fluorine twist introduces both hydrophobic and electron-withdrawing effects. In our experience, no substitute behaves quite the same in applications where precise hydrogen bonding and altered solubility profiles matter. Whether for agricultural intermediates, medicinal chemistry, or performance materials, the small difference in structure means large effects in the final application.
One memorable collaboration involved a customer working on new polycarbonate blends. Standard cyclohexanol-based additives gave inconsistent physical properties in the polymer matrix. With 4,4-Difluorocyclohexanol, they finally tuned both flexibility and hardness—achieving batch-to-batch consistency. The subtle dipole adjustment from the twin fluorine atoms pushed their results from theoretical curiosity to marketable product.
From our perspective, handling any fluorinated cyclohexanol starts with good ventilation, dedicated glassware, and avoiding exposure to reactive bases and acids. This molecule exhibits greater stability compared to some mono-fluorinated analogs, but we find that moisture control during transfer and weighing makes all the difference. Poly-sealed containers with desiccants keep the product stable for months in ambient storage. For customers unfamiliar with this compound, we caution that typical handling protocols for cyclohexanol do not suffice: gloves resistant to fluorochemicals, secondary containment, and regular checks of storage temperature maintain both purity and safety.
In larger projects, drum transfer always requires closed-system procedures. We emphasize this not only to meet compliance but also because the cost of spoiling a batch through minor exposure outweighs any savings from expediting transfers.
Even a reliable chemical takes on a new profile when produced at industrial scale. Our approach centers around controlling impurity profiles, especially fluoroacetates and low-boiling cyclic ethers that sometimes arise in sub-optimal synthesis runs. On analytical equipment, the difference between trace contaminant and undetectable can mean success or failure for an end-user’s catalysis run. Our documentation includes batch-specific NMR and GC-MS charts because our customers—especially those scaling up pharmaceuticals—have told us a thousand times that they trust only data they can see for themselves.
Batches retain sub-1% moisture content and maintain optical clarity. These aren’t arbitrary numbers—fluorinated alcohols absorb water from the air rapidly, and unchecked, the material’s performance suffers. We’ve developed closed-loop drying and packing procedures that grew out of lessons learned from years ago, after customer feedback traced a yield drop to atmospheric uptake at our transfer station.
Chemists often ask why use 4,4-Difluorocyclohexanol over 4-fluorocyclohexanol or standard cyclohexanol. The answer rests in the physical and electronic differences. Mono-fluorinated versions lack the same degree of biological persistence and electron-withdrawing capability. In reactivity, 4,4-difluoro- settings produce different selectivity and stronger resistance to oxidation, proving invaluable in certain synthetic paths. Unmodified cyclohexanol offers higher nucleophilicity but at the cost of stability and lower resistance to hydrolysis in harsh conditions. These changes translate to variables in product shelf-life, compatibility with bases, or metabolic fate.
A good example arises in agrochemical synthesis. Control over metabolic degradation paths often sets the difference between an environmental concern and a breakthrough product. Our 4,4-Difluorocyclohexanol supplies the needed backbone for side chains that resist breakdown, enabling new classes of persistent active ingredients. Similar stories echo in advanced material R&D, where differences in melting point and phase behavior influence performance in flexible OLEDs or liquid crystals.
One recurring challenge involves the strict removal of hydrofluoric acid traces and downstream by-products. On the production floor, we’ve invested in modern filtration and column packing materials that withstand aggressive cleaning without leaching into the product. Our teams regularly retrain in analytical techniques—NMR, titration, Karl Fischer titration for water—to cement a hands-on understanding of what goes into quality assurance. Our approach to problem-solving is iterative: examine feedback from small-scale customers using the product in medicinal chemistry, then compare those findings with bulk buyers synthesizing new monomers. The pattern of recurring requests for lower moisture, or less volatile by-product, pushes us to refine batch procedures each quarter.
Early on, inconsistent color and faint foul odors pointed us toward tiny impurities. We traced these to recycling lines in our solvent reclamation unit. Upgrading those lines cut the impurity rate by 60% within the year. Joint troubleshooting sessions with our analytical chemists and production engineers form the backbone of these improvements. Cultivating transparency with end-users forms the final check.
Fluorinated cyclohexanols used to be niche products with limited customers. Now, with the uptick in fine chemical and specialty polymer research, more users enter the arena looking to exploit the characteristics that fluorine substitutions provide. The compliance burden grows as well. REACH in Europe, TSCA in the United States, and local environmental regulations worldwide shape day-to-day operations. Maintaining high purity, clear hazard labeling, and batch tracking for regulatory audits keeps our compliance team busy. Years ago, a lax view might have passed, but oversight has tightened. Regular customer audits challenge us to document improvements and justify each process step.
Shared industry forums allow us to exchange ideas about sustainable synthesis methods. For 4,4-Difluorocyclohexanol, researchers continue to develop fluorination steps with greener solvents and recyclable catalysts, with ongoing trials on our pilot lines. Finding a balance between minimizing hazardous waste and maintaining yield informs each run.
We’re constantly reminded by colleagues and competitors alike that supply chain robustness comes from flexibility. Sourcing local precursors whenever possible, qualifying backup suppliers through repeated QA checks, and keeping safety stock—not just for ourselves but for key clients—delivers consistency in an unpredictable world.
As direct manufacturers, our conversations with users often drift beyond orders to the long-term plans for research programs. More universities, startups, and established firms bring us questions on how to scale up a synthesis reliably, or surmount batch-to-batch variations in competing suppliers’ products. We disclose all detectable impurity levels, even for those under regulatory thresholds, because hearing from our clients about what works—rather than what should work—guides us better than any one-size-fits-all approach.
Some customers ask about using 4,4-Difluorocyclohexanol to block unwanted biotransformations. Others need selectivity in cyclization, or improved physical properties in new polymer films. Our technical support team, mostly staffed by chemists who trained in production roles, offers advice grounded in actual runs, not catalogue predictions. Feedback cycles run both ways: trial failures in their hands prompt us to look for bottlenecks or false negatives in our QC steps.
Reflecting on our experience, supporting innovation has meant going beyond documents and spec sheets. Direct manufacturer input often helps customers avoid costly missteps, like choosing incompatible solvents, or misunderstanding reactivity trends between difluoro- and monofluoro- derivatives. This collaborative approach means we regularly update our application notes and technical guidance, linking observations from our reactors to field results.
Down-to-earth accountability sits at the heart of our manufacturing ethos. Our process logs, chain of custody records, and product-specific certificates fill boxes in the QA office, waiting for the next audit or review. Customers in Europe, North America, and Japan each expect transparent disclosure about starting materials, any auxiliary agents, and impurity carry-through. We receive regular requests to supply third-party analysis or additional declarations matching regulatory frameworks.
Our team meets regularly to revisit standard operating procedures, often updating them after a technical issue appears in a shipment or an audit reveals gaps. No matter how tight the production run, a single missed cleaning step or a fluctuating temperature profile crops up as a defect or complaint. Addressing these discoveries shapes not just production batches but also broader ethical practice in chemical manufacturing.
Doing things right doesn’t stop with the reactor or the drying tower. We select container type, size, and closure based on chemical compatibility with 4,4-Difluorocyclohexanol, after decades observing how tiny changes in packing protocol affect long-term stability. For most batches, we use glass vessels with fluoropolymer-lined caps, plus secondary packaging and desiccant packs. Customers with specialized storage needs discuss options with our logistics team before shipment. We avoid cost-cutting steps that compromise shelf life or invite contamination. End-users in pharmaceuticals and materials research reinforce the value of these precautions every time they return for fresh batches.
We share recommended storage conditions with every shipment—room temperature for short-term, refrigerated for long hold times, always dry and sealed. These instructions reflect the reality of tracking product quality from our floor to a customer five thousand kilometers away.
The supply chain for fluorinated inputs faces periodic volatility. We develop contingency plans for tight windows, often pre-qualifying alternate grades or tracking potential disruptions months in advance. If feedstock purity slips, or if a global event disrupts supply, we reach out to customers early. We keep them apprised of constraints, aiming for as much advance notice as possible so they can modify R&D or production plans.
Running a chemical manufacturing operation means embracing unpredictability. Reactors fail, suppliers let us down, or regulations shift. Our team’s experience means we typically spot trouble before it upends a key batch. Quick pivots—redistributing production to alternate lines or running smaller campaigns to preserve priority orders—keep products like 4,4-Difluorocyclohexanol available to customers pushing new boundaries. Ultimately, knowledge and adaptability outweigh automation or process alone.
Making 4,4-Difluorocyclohexanol at scale means blending technical skill, real-world knowledge, and continuous improvement. We find success not only in mastering the synthesis itself but also in building strong feedback loops with customers, scientific partners, and quality control teams. There are no shortcuts to consistent high purity, reproducible performance in user applications, or safe, compliant shipments. The differences between this and related cyclohexanols are sometimes subtle on paper and stark in practice, affecting everything from reactivity to stability to regulatory track record.
Looking forward, we remain dedicated to refining every batch, updating analytical protocols, and sharing hard-won insights that let our customers put 4,4-Difluorocyclohexanol to the best use across new industries. Each drum and bottle represents not just a chemical, but the combined work of a team intent on delivering trust alongside product.