HS Code |
974878 |
| Chemical Name | (1R)-(-)-Camphorquinone |
| Cas Number | 68454-82-2 |
| Molecular Formula | C10H12O2 |
| Molecular Weight | 164.20 g/mol |
| Appearance | Yellow crystalline solid |
| Melting Point | 197-203 °C |
| Solubility | Slightly soluble in water, soluble in organic solvents |
| Optical Rotation | [α]D20 = -187° (c=1, ethanol) |
| Purity | Typically ≥98% |
| Iupac Name | (1R)-1,7,7-Trimethylbicyclo[2.2.1]heptane-2,3-dione |
| Density | 1.23 g/cm³ |
| Refractive Index | n20/D 1.538 |
| Flash Point | Over 110°C (closed cup) |
| Shelf Life | Stable under recommended storage conditions |
As an accredited (1R)-(-)-Camphorquinone factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging features a 25g amber glass bottle with a secure cap, labeled with chemical details and hazard warnings from Sigma-Aldrich. |
| Shipping | (1R)-(-)-Camphorquinone is shipped in tightly sealed, chemically compatible containers to prevent contamination and degradation. Packaging follows international hazardous material guidelines (UN/IMDG/IATA). Shipments are handled at controlled ambient temperatures, protected from light and moisture. All containers are clearly labeled and accompanied by safety data sheets, ensuring safe and compliant transportation. |
| Storage | (1R)-(-)-Camphorquinone should be stored in a cool, dry, and well-ventilated area, tightly sealed in its original container, and protected from light, heat, and moisture. Avoid strong oxidizing agents. Store at room temperature, away from sources of ignition and incompatible substances. Ensure compliance with Sigma Aldrich, Merck, or TCI chemical storage safety guidelines and applicable local regulations. |
Competitive (1R)-(-)-Camphorquinone prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Manufacturing (1R)-(-)-Camphorquinone has taught us the real value of hands-on chemistry. Over the years, this compound has shifted from a specialist’s curiosity to a daily mainstay for many applications, especially in visible-light photopolymerization. Customers often ask what sets this compound apart, not only from a chemical standpoint but also in practical use. Our factory’s years of experience supplying directly to dental material manufacturers as well as optical coating producers, put us in a unique position to talk plainly about this compound’s role, its quirks, and its difference from more generic alternatives.
Our (1R)-(-)-Camphorquinone always turns out as a yellow, crystalline powder—something easy to spot if you handle enough of it. Consistency in color and texture means more than just looks. When the solid appears off-color or clumpy, it signals trouble with purity or residual solvents. We found even small contaminants impede the photoinitiating action, sometimes sabotaging the entire production run of dental materials or adhesives. By focusing relentlessly on purification, repeated recrystallization, and strictly controlling solvents during synthesis, our batches avoid the traps of off-spec lots sometimes seen in the distribution chain.
Experienced technicians will back me up here: subtle changes in quality have a domino effect in end-use settings. In dental composites, for instance, even minor impurities present in camphorquinone can trigger discoloration or compromise curing depth. Across countless customer audits, the most discerning clients bring out their colorimeters and UV-Vis spectrophotometers to check the absorbance maximum near 468 nm. Our process ensures repeated, reliable results for this peak, giving clients confidence batch after batch.
You can find camphorquinone at varying degrees of purity and optical activity, but we insist on producing the (1R)-enantiomer with >99% enantiomeric excess. Other camphorquinones in the market sometimes blend both enantiomers. Why does this matter? The photoinitiation rates depend not just on the overall purity, but also on the optical configuration. Most literature concurs that materials containing the (1R)-(-)-isomer display more reliable curing rates in photoinitiation, especially when exposed to LED or halogen curing lights.
We control optical purity from the chiral starting materials all the way through the oxidation step. Sloppy synthesis, especially uncontrolled oxidation conditions, introduces significant isomeric impurities, reducing efficiency and potentially releasing unreacted starting material. There’s no substitute for careful monitoring through chiral HPLC and frequent quality checks throughout each batch’s journey.
Across each production cycle, (1R)-(-)-Camphorquinone leaves our plant with specifications shaped by countless industry conversations rather than template-driven paperwork. Chemists working on dental resins, 3D printers, and photoresponsive coatings often ask about melting point accuracy and trace metal content because off-target values sometimes translate directly to failed QA at the customer’s line. We routinely hit melting ranges between 198–200 °C. This may sound trivial, but the difference between an uncontrolled melt and a sharp transition reflects the discipline of dried intermediates and tight crystallization protocols.
Each batch undergoes quantification through HPLC with diode array detection, checking for purity levels above 99%. Chiral purity, sometimes dismissed by resellers, consistently rises to the top of inquiries from those who’ve been burned before with color-unstable or slow-initiating products. Our assay panel also screens for heavy metals and byproducts—less obvious risks that meet the harshest regulatory standards for dental and medical device intermediates.
Much of the dialogue with our longstanding partners revolves around stability under warehouse conditions. Warehouse operators often push back against high humidity, but repeated in-house trials have shown our (1R)-(-)-Camphorquinone maintains shelf stability for years when stored below 25°C in tightly sealed, light-protected packaging. Loss of photoinitiating power has never plagued batches handled with these measures.
If you visit our factory, you’ll see (1R)-(-)-Camphorquinone cases destined for more than just dental filling producers. The world now leans heavily on visible light-cure technologies, from compact LED-cured polymers to specialty ink-jet resins and even hydrogels for medical sensors. Young startups often come with fresh ideas, sometimes running photoresponsive coatings in R&D or medical diagnostics. Few realize how much the initiator impacts their overall blend. We maintain direct communication lines not only with multinationals but also with smaller labs, because the same technical hitches crop up no matter the scale.
Dental resin customers focus heavily on polymerization depth under practical clinical lighting. Their lived experience is that lower-purity photoinitiators set teeth with inconsistent surfaces, which push patients back for costly rework. Cosmetic manufacturers often chase the balance of rapid curing and yellowing resistance, critiquing the shade shifts that even trace byproducts introduce over time. Our understanding of these problems doesn’t come from testing alone but from troubleshooting customer complaints alongside their production chemists. There’s pride in spending weekends helping customers tune their resin blends, solving problems well upstream of any commercial fallout.
The greater visibility of 3D printing has placed renewed pressure on initiator reliability. Many rapid-prototyping teams came our way after finding off-shore product suffering from batch inconsistency or showing unpredictable reactivity. High-purity (1R)-(-)-Camphorquinone moves the needle on resolution, especially in the creation of micro-scale patterns and fast-cure geometries. Customers consistently tell us the initiator is one of the largest sources of variability in their results, often outweighing tweaks in formulation or hardware setup.
Over the years, plenty of discussions about switching from camphorquinone to other photoinitiators have reached our doors. Some point to cheaper alternatives like benzoin ethers, aromatic ketones, or even acylphosphine oxides. Real-world performance, though, keeps (1R)-(-)-Camphorquinone at the center for visible light systems. Other initiators often fall short in matching the absorption profile, especially in standard blue LED ranges.
Switching initiators sometimes feels tempting for price reasons, but any reported savings on raw materials often vanish once projects realize the new initiator’s absorption doesn’t line up with in-market dental lamps. LED manufacturers now fine-tune emission wavelengths to match the 468 nm absorption band—something with which (1R)-(-)-Camphorquinone aligns perfectly. This synergy delivers faster cure rates and deeper polymerization, without leaving large amounts of uncured monomer. Unreacted residues bring their own cascade of regulatory headaches, particularly in devices and fillings where patient health sits on the line.
Another common question involves optical transparency. Some projects struggle with initiator-induced yellowing. Lower purity initiators or poorly controlled analogues can significantly impact the final appearance, while (1R)-(-)-Camphorquinone maintains low color impact through minimized impurity content. Long-term stability against photo-degradation ensures end-products won’t darken over time, a concern especially relevant in high-value restorative or display applications. We never take shortcuts to keep the impurity load tiny—something that only happens if you control every synthetic and post-processing step.
Environmental requirements have grown sharper each year. Dental product makers come with high expectations and little tolerance for heavy metals, residual solvents, or unvalidated manufacturing routes. Our operation keeps auditor visits open, documentation transparent, and traceability tight all the way back to the raw inputs. We work directly with our bulk substrate providers and test regularly for contaminants like mercury, lead, and other restricted elements. This diligence reflects real-world lessons most chemical producers learn only after years of close regulatory oversight.
Our system for data collection means every batch’s test report can be matched to in-service performance. Deviations get traced back and diagnostics begin on the ground, not in a distant QA lab with generic feedback. Customers often open their plants to us, making us part of their internal audit circle. This trust isn’t built overnight, but by continually passing real third-party inspections, providing up-to-date Certificates of Analysis, and tackling action points directly with the end-user.
Running large-scale (1R)-(-)-Camphorquinone synthesis brings plenty of practical challenges you won’t learn from academic papers. Oxidations are sensitive, both to air and overheating. Overdoing the oxidant or losing temperature control introduces unwanted isomers or burns the product, creating impurities that no amount of later filtration can erase. We’ve invested in process automation systems for fine control, logging every anomaly to flag batches for early intervention instead of waiting for a downstream fail.
Operator skill sets make a difference, especially when it comes to handling hazardous intermediates or conducting final purifications. Competent chemists trained over years in our facility know what a perfect fraction looks like and when something smells wrong. We encourage staff to call a halt on batches when the output doesn’t meet tactile and visual cues. Empowering team members this way heads off issues far earlier, saving both time and costly raw input.
Even packaging demands strict attention. The difference between well-sealed kegs and those exposed to air matters; camphorquinone absorbs moisture and light-nicked material simply doesn’t perform to spec. Our QA teams hand-inspect seals and use heavy-gauge, light-resistant barrels that block visible and UV light right at the shipping dock.
Direct contact with end users shapes our process improvements more than any industry standard ever has. Most of our new initiatives come straight from detailed feedback: resin blenders switching to automated lines, medical innovators requesting finer particle sizing or more transparent products, or even a request for specific documentation to meet a rare local standard. As a direct producer, we flex quickly to these requirements, a responsiveness third-party distributors often can’t match.
Some years ago, a rush order during a supply chain crunch meant reworking our production timeline and sparing trained staff to come in off-hours just to ensure uninterrupted supply to a major dental consumable producer. Working directly, we discuss their QA problems openly and adapt our process rather than hiding behind contractual terms. That level of partnership only happens through consistent quality, transparency, and openness to scrutiny.
Research clients increasingly want technical explanations for minor variances. We embrace their questions, sharing representative chromatograms, data tables, and even syntheses when it helps improve collaboration. Wherever possible, we test our batches in similar conditions or with equivalent equipment so feedback is more than theoretical—it reflects real use scenarios, whether it’s the mechanical properties of a set dental composite or the optical clarity in an advanced hydrogel.
Our company has spent decades perfecting the production of (1R)-(-)-Camphorquinone, but standing still isn’t a viable strategy. With new lighting technologies, such as advanced blue LEDs and emerging UV-visible hybrid sources, our R&D is exploring further fine-tuning of purity and scaling pilot lines for improved sustainability. The laser focus remains on having each batch perform out of the drum—no need for customer rework or extensive pre-screening. Consistency means less downtime and simpler operation at the customer’s end, ultimately saving more than any theoretical cost cut could.
We also continue to invest in cleaner synthetic routes, minimizing waste and capturing solvents for upcycling or controlled disposal. Stringent monitoring for environmental performance matches our focus on upstream purity, making our operation compliant with local environmental standards and internationally accepted supply chain protocols.
Ongoing dialogue with universities and technical partners keeps us plugged into the future. New chemical analysis techniques, automation upgrades, and scalable chiral separation all inform our process roadmap. Rather than waiting for regulation to force a change, we aim to anticipate needs, delivering low-risk, high-value (1R)-(-)-Camphorquinone that works from day one on any validated line.
Producers sometimes talk up new technology, but the methods that produce true (1R)-(-)-Camphorquinone remain rooted in fundamental chemistry, careful scale-up, and institutional know-how. Shortcuts or switching to off-shore intermediates inevitably show up in lower, less reliable product quality. Sticking to our fully in-house production, from synthesis to packaging, we deliver not just a powder but a track record proven over years of real-world testing, audit, and feedback. Customers trust us because we keep the focus on chemistry that works under true conditions, not just on paper. The benefits show up in better performance, less downtime, and a smoother path to regulatory approval—results only the manufacturer can guarantee through transparency, detail, and genuine partnership.