West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

1,1,1,2,2,4,5,5,5-Nonafluoro-4-(trifluoromethyl)-3-pentanone

    • Product Name 1,1,1,2,2,4,5,5,5-Nonafluoro-4-(trifluoromethyl)-3-pentanone
    • Alias Novec 1230
    • Einecs 253-981-2
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    785989

    Iupac Name 1,1,1,2,2,4,5,5,5-Nonafluoro-4-(trifluoromethyl)-3-pentanone
    Cas Number 756-13-8
    Molecular Formula C6F12O
    Molar Mass 316.04 g/mol
    Appearance Colorless liquid
    Boiling Point 49°C (120°F)
    Melting Point -108°C (-162°F)
    Density 1.60 g/cm³ at 25°C
    Solubility In Water Insoluble
    Vapor Pressure 27.61 kPa at 25°C

    As an accredited 1,1,1,2,2,4,5,5,5-Nonafluoro-4-(trifluoromethyl)-3-pentanone factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing 250 mL amber glass bottle, with secure screw cap, labeled by Sigma Aldrich, displaying hazard warnings and product information for laboratory use.
    Shipping **Shipping Description:** 1,1,1,2,2,4,5,5,5-Nonafluoro-4-(trifluoromethyl)-3-pentanone (Sigma Aldrich/Merck/TCI Chemical Grade) is typically shipped in sealed, chemically-resistant containers, protected from moisture and heat. It is transported following local regulations, often as a non-flammable, environmentally hazardous substance. Proper labeling and safety documentation accompany each shipment.
    Storage **Storage Description:** Store 1,1,1,2,2,4,5,5,5-Nonafluoro-4-(trifluoromethyl)-3-pentanone in a tightly sealed container in a cool, dry, and well-ventilated area, away from heat, ignition sources, and incompatible substances such as strong oxidizers. Protect from moisture and direct sunlight. Use chemical-resistant containers and ensure proper labelling. Follow all local, state, and federal storage regulations for perfluorinated compounds.
    Free Quote

    Competitive 1,1,1,2,2,4,5,5,5-Nonafluoro-4-(trifluoromethyl)-3-pentanone prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    1,1,1,2,2,4,5,5,5-Nonafluoro-4-(trifluoromethyl)-3-pentanone: A Practical Perspective from the Production Floor

    Practical Chemistry in Industry: An Introduction to Modern Fire Suppression Needs

    As a chemical manufacturer deeply invested in specialty fluorinated compounds, we've seen 1,1,1,2,2,4,5,5,5-Nonafluoro-4-(trifluoromethyl)-3-pentanone, also known as FK-5-1-12 or Novec 1230, grow in reputation. The development and steady improvement of this chemical reflect real-world shifts in industrial needs—especially for companies searching for fire suppression solutions that actually meet modern regulatory and environmental standards. Gone are the days when companies could freely use halon-based systems or other ozone-depleting agents without consideration for ecology and compliance. Over the years, customers often ask about our first-hand experience with the manufacture, batch quality, and field performance of this material, so let's take a direct look at what sets our product apart and where it fits in present industry demands.

    Physical Qualities Shaped by Experience and Demand

    FK-5-1-12 leaves our facility with a purity higher than 99.5%. Rigorous distillation controls, in-line real-time monitoring, and final QC by gas chromatography ensure that the finished product meets the tightest tolerance windows in the market. The clear, colorless liquid transitions easily to vapor at room temperature, a trait that supports its appeal in total flooding systems, though we’ve observed our customers using it in smaller portable units as well. With a boiling point near 49℃, the compound evaporates rapidly, leaving minimal residue and making it an ideal candidate for sites with sensitive electronics, historical archives, or clean rooms. During routine discussions with system integrators, their teams often commend its low residue compared to earlier-generation agents. Over many years of real-world feedback, we've confirmed this characteristic plays a big role in minimizing downtime after discharge events. The low odor and high dielectric strength matter for enclosed settings, which is why global electronics manufacturers and data centers frequently partner with direct-source producers.

    Applications Built into the Manufacturing Process

    Fire suppression sits at the center of FK-5-1-12's industrial value. Back in the early 2000s, manufacturers faced mounting pressure to replace halon agents due to tightening environmental regulation, most notably the Montreal Protocol. FK-5-1-12 became the answer, and not by accident. Over years of refining synthesis, we've fine-tuned production to achieve batch-to-batch consistency that customers depend on for mission-critical fire protection in their assets. Unlike conventional agents, our product shows negligible ozone depletion potential—well established by published studies—and a Global Warming Potential below 1, meeting EU F-gas requirements and the US SNAP program criteria. System installers tell us regulatory approval processes have grown simpler specifically because of these traits. Equipment OEMs integrate our compound into both new installations and retrofits due to the compound’s compatibility with existing hardware, reducing transition pains for end users.

    Direct feedback from those overseeing fire suppression system maintenance reports straightforward refilling, thanks to the product’s liquid stability and packaging options. Facilities in semiconductor, aviation, museums, and high-density computing infrastructures switch to our material to avoid the regulatory headaches tied to legacy agents. Our close relationships with maintenance contractors, who supervise continuous protection of high-value assets, have provided clear evidence that FK-5-1-12's low toxicity and rapid dispersion help businesses return to operation without linger threats to sensitive machinery or records. Real-world case studies further support environmental safety, with measured atmospheric lifetimes in days, compared to centuries for legacy greenhouse gases.

    Specifications Shaped by Practice, Not Theory

    Unlike purely theoretical data sheets, our plant operators monitor each finished batch for practical parameters. Density measures about 1.6 g/cm³ at 25°C—a feature that makes the product easy to handle in automated filling equipment or hand-operated packaging lines. Viscosity remains stable at a broad range of temperatures, eliminating operational surprises when refilling onsite tanks across a variety of climates. Flash point is not observed under standard conditions, which significantly reduces handling risk within industrial and commercial sites. We package FK-5-1-12 in containers ranging from small drums for pilot plants up to ISO tanks for global transportation, monitoring valve integrity and umbrella inert gas blanketing throughout storage and transit.

    For manufacturers, the purity standard minimizes risk of secondary reactions inside complex suppression networks—a concern too often glossed over by bulk resellers less attuned to downstream reliability. We know from hard-won experience that end-product performance isn’t just about headline specifications. Our in-house engineers regularly conduct full-system discharge tests using product from actual commercial batches, rather than small laboratory lots. This guarantees the same product we ship on pallets also performs under real discharge conditions, echoing what end customers rely on for insurance compliance and critical asset safety.

    How FK-5-1-12 Differs: On the Line and in the Field

    Many in industry ask about the key differences between FK-5-1-12 and legacy fire suppression chemicals like HFC-227ea, HFC-125, or classic halons. Direct manufacturing experience draws out the real contrasts. For one, FK-5-1-12 delivers vastly improved environmental credentials. Published global warming potential figures for HFCs routinely exceed 3,000, with atmospheric lifetimes reaching up to 50 years or more. In contrast, FK-5-1-12 degrades in the lower atmosphere in roughly five days, so its ecological impact drops by orders of magnitude. Regulatory documents worldwide, from the US Environmental Protection Agency to the European Chemicals Agency, recognize this difference, and so do the customers who pass regular inspections.

    We've fielded concerns about toxicity, especially from users in aviation or data centers worried about personnel safety during system discharge. Acute toxicity studies classify FK-5-1-12 as having very low mammalian toxicity compared to hydrofluorocarbons or traditional halon gases. Product adoption among leading aerospace technicians, who often work in confined fuselage environments, highlights a key feature: exposure to our agent during system testing or emergencies does not result in reportable adverse effects, unlike some halogenated alternatives. These reports reach us directly from hangar staff and safety officers, not via reseller intermediaries.

    Heat absorption rates drive performance for suppressing incipient fires in high-density electronics or archival spaces. FK-5-1-12 exhibits a high heat of vaporization, allowing rapid cooling of flame fronts and hot surfaces before larger structure ignition. Company fire marshals who review discharge reports regularly cite fast knockdown and minimal re-flash risks, particularly in high-value server rooms and telecom facilities. End users seeking replacement options for halon or HFC systems find similar and often improved extinguishing performance: our lab data aligns tightly with field incident reports and customer satisfaction surveys.

    Why Industry Professionals Are Shifting Their Preferences

    Insurance underwriters and compliance teams increasingly demand robust environmental and occupational safety framing in their chosen agents. FK-5-1-12 stands out not on the basis of marketing but from the concrete compliance documentation that comes directly from hands-on chemical producers. Technical certification bodies routinely request batch-level Certificates of Analysis to accompany delivered product; our documentation systems satisfy these requirements without lengthy delays because all testing is done on-site, at the time of production. Regular audits help customers maintain ISO 14001 or similar sustainability certifications, with direct data derived from production and emissions logs.

    Retrofit cases surface repeatedly in the global market, especially when older HFC- or halon-based systems phase out. Our in-house engineering staff work alongside installation partners to guide integration—highlighting pipe compatibility, nozzle selection, and storage requirements tailored to local conditions, rather than simply replicating a generic setup. In nearly every retrofit scenario, FK-5-1-12 cycles through existing piping, tankage, and pump assemblies without corrosion or swelling issues. Field feedback reveals that, over multiple refill and discharge cycles, system integrity remains uncompromised, and supervisor reports rarely indicate any material failures or long-term degradation.

    Operator-Focused Handling: What Matters in Daily Use

    Shop floor teams and maintenance staff need materials that handle predictably. We have worked with plant superintendents and system refill technicians around the world who report that FK-5-1-12 fills evenly and runs through common pumping and metering hardware with no sticking, coking, or gumming—a challenge noted with some older suppression agents when humidity or temperature stray out of specification. In shipping, its classification as a non-hazardous liquid under many international standards allows for simpler logistics and fewer headaches at customs points, which directly benefits large-scale users with distributed sites.

    Product stability under variable temperature and pressure, demonstrated in independent and in-house aging studies, means longer shelf life in store rooms and easier management of backup contingency stock. Our own manufacturing team has compared real-storage outcomes with simulated stress regimens to validate that degradation remains insignificant well beyond standard inventory turns. Customers with cold climate installations—like satellite ground stations in Scandinavia—value its low pour point and lack of phase separation during extended storage, which sidesteps delays or failures at critical deployment moments.

    Supply Reliability and Technical Backbone

    Supply interruptions cost money and, more importantly, jeopardize site safety. In our operations, robust upstream sourcing, dedicated synthesis reactors, and continuous technical training build reliability throughout the product chain. We maintain close, open communications with customers who forecast seasonal or cyclical demand spikes, so we scale production ahead of time rather than reactively scrambling. Years of mission-critical deployments in data centers and energy infrastructure projects established long-standing relationships with procurement offices that count on next-day order fulfillment, often built around blanket orders secured months in advance.

    Our onsite laboratories cross-reference each lot with global regulatory requirements. We routinely provide technical support to OEMs, system integrators, and end users looking to interpret third-party test standards or build new designs around FK-5-1-12. Understanding the details of application—where, for example, a manufacturer in Tokyo uses the agent in a museum precinct versus a Houston data center—lets us offer hands-on advice, from recommended fill ratios to refill procedures and safe disposal.

    Environmental Stewardship Rooted in Process, Not Only Product

    Modern production practices now demand environmental stewardship that extends beyond the product itself. Our emissions monitoring not only satisfies legal thresholds but produces a footprint profile visible to buyers at any stage. Most customers require attestation about waste stream management and atmospheric releases. Tracking solvents, raw materials, off-spec output, and reclaim processes allows us to close the loop on environmental liabilities without shifting burdens downstream.

    Regulatory teams in our plant work in sync with product engineers to upgrade containment on process lines and storage tanks as requirements change, investing directly in advanced scrubbers and spill countermeasures. Over time, this means customers not only gain environmental advantage by using FK-5-1-12, but also minimize risk of future regulatory exposure through credible records of origin and manufacturing history. Our approach prioritizes transparent communication on the environmental journey, as we regularly share emissions data and improvement goals with customers and the wider industrial community.

    Collaborative Solutions for Ongoing Industry Challenges

    Despite its many benefits, FK-5-1-12 is not a universal fix for every fire suppression scenario. Our direct experience points out a number of operational and logistical hurdles. Cost can run higher per unit volume compared to incumbent HFC materials, especially for large system installations. Early adopters often saw material price volatility due to scaling supply chains and periodic raw material constraints. That said, costs have stabilized in recent years as process yields improved and global demand grew. For high-value facilities where the cost of downtime or asset loss dwarfs agent expenditures, managers judge the proposition as worthwhile. We address customer concerns over pricing with transparent quotations tied to prevailing market rates, free from hidden fees or hedge surcharges found in some spot markets.

    System compatibility also stirs questions. Although design drop-in is possible for some legacy systems, others require new discharge calculations or nozzle fitting. To speed adoption, we provide detailed flow calculations and retrofit guidelines based on actual discharge tests. Site surveys, both virtual and in-person, help maintenance teams calibrate systems properly. That way, fill density, room sealing, and venting are set up correctly from the outset—reducing risk of regulatory non-compliance or insurability issues post-installation.

    Climate and site-specific standards sometimes push manufacturers to consider blended or hybrid suppression strategies. We regularly consult on applications demanding tailored suppression for mixed hazards, such as combining FK-5-1-12 with inert gases or water mist systems to satisfy code or mitigate re-ignition risk. Collaboration with facilities engineers delivers solutions rooted in the specifics of site geometry and risk profile, not just broad product marketing claims.

    Commitment to Future-Ready Chemical Manufacturing

    The shift in focus toward sustainability, operational safety, and regulatory alignment will only intensify. As a manufacturer, our ongoing investment in process optimization, emissions control, recycling of off-spec streams, and responsive customer support is driven by long-term partnerships, not single transactions. We stake our reputation on the reliability and performance of each batch shipped.

    Empirical feedback loops, spanning plant-floor operators, safety engineers, maintenance technicians, and end-users, continue to shape how we develop, refine, and deliver FK-5-1-12. Real-incident reports, installation audits, and hands-on training initiatives help close the knowledge gap between production and application. Through this constant exchange, we identify areas for further improvement—whether it involves container innovation, on-site refill kits, or digital product tracking to support supply chain transparency.

    Our long-term vision sees FK-5-1-12 as more than a replacement chemical: it stands as a product of what responsible manufacturing achieves when built on credible science, practical collaboration, and transparent operations. Consultations, technical site support, and proactive product stewardship are not side offerings—they form the backbone of our service, designed for every sector and risk profile.

    Conclusion: Learning, Adapting, and Shaping the Future Together

    As manufacturing professionals with years on the line, we see FK-5-1-12 as the product of steady experience, honest dialogue with users, and the drive to outpace shifting regulatory and technical benchmarks. By staying rooted in practical experience—on the batch floor, in technical meetings, and during system commissioning—we build a future where specialty chemicals safely protect life and assets without leaving an outsized environmental footprint. Working together with plant engineers, architects, and safety managers, we continue to shape both best-practice and the evolving definition of what “good chemistry” means in the modern world.