|
HS Code |
661413 |
| Chemical Name | Diethyl 2,2-dipropylmalonate |
| Molecular Formula | C13H24O4 |
| Molar Mass | 244.33 g/mol |
| Cas Number | 3288-19-1 |
| Appearance | Colorless to pale yellow liquid |
| Boiling Point | 285-287 °C (at 760 mmHg) |
| Density | 0.963 g/cm3 |
| Refractive Index | 1.430 |
| Flash Point | 111 °C |
| Solubility | Insoluble in water; soluble in organic solvents |
| Smiles | CCOCC(CCCC)2(C(CC)CC)C(=O)OCC |
| Purity | Typically ≥98% |
| Storage Conditions | Store in a cool, dry place, tightly closed container |
| Odor | Characteristic ester-like |
As an accredited Diethyl 2,2-dipropylmalonate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Diethyl 2,2-dipropylmalonate (100 mL) is supplied in an amber glass bottle with a tamper-evident cap and chemical labeling. |
| Shipping | Diethyl 2,2-dipropylmalonate is shipped in tightly sealed containers to prevent leakage and contamination. It is typically transported at ambient temperature, away from heat and ignition sources. Shipping complies with regulatory standards (DOT/IATA/IMDG) for safe handling of chemicals. Appropriate documentation and hazard labeling are included by Sigma Aldrich, Merck, or TCI. |
| Storage | Diethyl 2,2-dipropylmalonate should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area away from sources of ignition and direct sunlight. Keep it away from incompatible substances, such as strong oxidizers and acids. Store at room temperature (15–25°C) and ensure proper labeling. Follow the supplier’s safety data sheet (SDS) for specific storage instructions. |
Competitive Diethyl 2,2-dipropylmalonate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
From the production floor, my colleagues and I see the real value behind every drop of Diethyl 2,2-dipropylmalonate. Years of technical refining shape the consistency that chemists and research engineers depend on for synthesis projects. Choosing the right malonate ester often sets the pace and purity of entire batches. DDM-222 stands out because we control the feedstocks, monitor temperatures, and hone distillation steps ourselves—direct hands-on work impacts its character. We’ve learned over repeated cycles how to drive down byproducts and keep trace impurities at bay, something generic esters never quite achieve. Our process leans on fractionation with real-time monitoring, so each drum shares the same reliability you’d expect from pharmaceutical-targeted ingredients.
Plenty of esters line catalogues today, yet few offer the tight control over isomeric form and purity ratio that we provide. Dropping in compounds like dimethyl or diethyl malonate seems simple — but the difference comes up fast in medicinal chemistry, specialty polymers, and high-value fragrances. Our DDM-222 provides solid backbone chemistry when synthesizing functionalized products or building blocks where minor variations can disrupt entire research programs. Granularity starts at procurement: each raw material ships with a full analytical profile. In our plant, the team runs small validation batches before switching over to full production, keeping off-target side reactions in check.
Throughout the process, hands-on checks matter. Each reactor cycle gets TLC, from nitrogen blanket adjustment to careful catalyst introduction—steps automated facilities usually gloss over for bulk throughput. Years running small- and large-scale reactors taught us that malonate esters don’t forgive careless heating or fast quenching. Too much variability and side reactions multiply. That’s why DDM-222 reaches the final drum after distillation under vacuum, sampled every hour, with chromatographic verification carried out in-real time. The end results have earned clients’ trust across Europe, North America, and Asia.
DDM-222’s formula gives research organizations three vital benefits: repeatable purity, narrow impurity profile, and robust supply. Our batches settle at a purity that routinely exceeds 99%. This tight range isn’t a marketing number—it’s the product of layered quality checks from in-process samples, not just a lucky spot check on one batch. Water content, acid value, and refractive index stay inside defined limits, year after year. Chromatograms from our QC lab display a sharp, isolated peak. When clients request more detail, we share full trace impurity panels, not just a generic COA.
For our team, using fresh raw materials and tightly maintained glass-lined reactors prevents overlapping chemical profiles that less-controlled facilities face. The workforce’s daily monitoring of temperature ramps, pressure curves, and solvent ratios keeps batch-to-batch reproducibility sharp. Our approach goes beyond statistics—operators fine-tune process controls, adjusting heating curves and reflux rates based on trends, not just recipe documents. When a run delivers unplanned sidecuts, the entire batch stands aside for further analysis before moving ahead. That’s discipline you only develop after losing time and raw material from preventable excursions.
Labs keen on specialty syntheses call for malonate esters that keep performance dependable even under stress. DDM-222’s blend of length and branching in the propyl groups gives it a lower tendency to form unwanted side products—this suits alkylation, condensation, and coupling protocols where regular malonic esters tend to introduce random fragments. The clean reactivity profile helps synthetic chemists trace exactly which fragment comes from which part of the molecule. Where standard diethyl or dimethyl malonates can muddy spectral data, DDM-222 avoids tacked-on signals from isomeric drift.
Regulated APIs, agricultural actives, and advanced polymer monomers often pivot on a single, subtle structural difference. Our work backing up clients’ method development teams has shown that reliable DDM-222 shortens the time between pilot and production. Synthetic routes stay reproducible because the ester margin matches the lab sample every cycle. Research partners have cut down on off-cuts and recrystallization cycles, citing cleaner analytical tracks from our product. That adds up to saved time, less waste, and lower cost per run.
Manufacturing DDM-222 in our facility, rather than outsourcing, gives us a close-up feedback loop. Early on, researchers noted that general-use diethyl malonates would drift batch by batch: yields fluctuated, and NMR results introduced uncertainty. Our DDM-222 doesn’t float with broader ranges, as we maintain a tight spread on impurity levels and final boiling points. The dipropyl side chains create a bulkier, less reactive intermediate, supporting longer reaction windows in condensation and nucleophilic routes. This opens doors for late-stage functionalization steps that can’t survive quick hydrolysis or volatile intermediates.
Unlike alternatives made through blended reprocessing, our stream runs discrete start-to-finish lots. The benefit? No cross-contamination between runs, no hidden mixed alkyl chains, and no concern about carryover from unrelated esters previously produced in the same reactor. Our product’s identity stands on lot records, chain of custody, and operator logs aligned to international practices. Clients working on patent-bound syntheses, particularly in agrochemical and pharma processes, avoid working with multi-purpose esters that threaten IP with unseen overlap or residuals.
We’ve held to a simple rule: make every batch as though we’ll use it ourselves. This took us down a path of investing in automated temperature ramping, programmable vacuum systems, and on-stream monitoring for GC-MS. Spending on instrumentation paid off; now, checks come not just at the end, but throughout the process. Issues are caught before the batch has left the reactor, leaving no surprises for the client. Sometimes old habits—manual titration, visual endpoint checks—come into play when newer methods flag something odd. It’s not about old versus new, but about what brings the best outcome for purity and reliability.
Our operators run hands-on takes at every stage. Seasoned staff recall years where a shift in solvent handling could set off significant downtimes. Now, tighter controls mean even stepwise additions and agitation cycles contribute to the bigger picture. During scale-up, we found agitation speed set the crystallinity of the final intermediate—a detail overlooked by newcomers. The lessons matter in bulk malonate work, because even volumetric differences between lab and pilot scale can swing particle size, filtration rate, and drying time. Our investments have meant that headaches from small deviations don’t reach the product, keeping downstream users free of run-to-run guesswork.
Our R&D collaborations regularly surface ways in which better malonate control drives faster discoveries. One international pharma partner sought analogues of an existing API. With generic diethyl malonate, their intermediates gave broad, unassigned peaks. We supplied DDM-222, worked with their analytical chemists, and saw their teams get sharper separation in their chromatograms. The resulting compounds matched targeted activity—and, crucially, cleared synthetic ambiguity. In this sense, having a stable supplier that also understands development project constraints takes on more weight than just delivering a chemical.
We also back up clients who need customized protocols. Sometimes, an extra purification step on our side, tailored solvent ratios, or temperature cycles extended at precise ranges, keeps their reactors clear and analytical methods straightforward. Our open-door policy means that method deviations or scale-up questions get resolved by talking directly to our technical team—no filters, no passing through third-party handlers. For companies building new routes, these conversations accelerate troubleshooting and ward off production bottlenecks that come with generic supply.
Chemical suppliers often stop at catalog listings, but manufacturing brings responsibilities that extend into implementation. We provide formulation support for customers eager to switch away from batch-to-batch uncertain malonates. During shipping and transit, our team monitors packaging specs—a lesson learned after one humidity spike highlighted the weakness of standard drums during long ocean voyages. Now, our drums are nitrogen-purged, lined inside and capped double, staving off hydrolysis and water pickup even in extreme climates. That insight traveled straight from a raw experience into our packaging policy, saving subsequent clients the pain of out-of-spec arrivals.
Clients using DDM-222 don’t face the frequent revalidation cycles required with loosely sourced chemicals. Our documentation keeps in step with cGMP guidances. Shipment records link directly with batch QC, a practice designed during our early years working with drug-intermediate customers. Clients pursuing credentialing or site audits find our chain of records ready to open up—as we see transparency as an ally, not a burden. That’s a stance fine-tuned by years balancing regulatory obligations with the real-world pace of R&D.
Scaling up DDM-222 demands steady raw material flows, vendor reliability, and a trained, on-site workforce. Molasses-like logistics, customs holdups, and global resin shortages have all had their days. Real improvement comes not from chasing the cheapest inputs, but from building up buffer stocks and fallback supplier lists. We devote energy to upholding full traceability, so no matter the global supply hiccup, clients get continuity on spec sheets and performance. Our long-standing operator teams anticipate seasonal impacts—like humidity swings, which can impact the physical state and stability in bulk containers.
Lessons learned during industry downturns and surges inform each year’s production plan. We stagger batch operations to match lead times, allocate extra lab cycles for new clients, and allow for short-notice reprocessing if analytical deviations show up. This agility is earned, not bought. Every run and shipment informs our future process tweaks, from valve upgrades to software for early-detection analytics. Our clients recognize that their scale problems receive attention not just as a sales opportunity, but as an operational mandate.
Within our facility, every operator logs steps. From raw input unloading, reactor charge timing, distillation pressure points, and even wash cycles, records follow each lot from start to finish. Our QA/QC teams operate independently, crossing off specifications before any dispatch leaves the warehouse. Samples from each batch go back into the lab for long-term retention—in case any field issue arises, side-by-side comparisons can be run under identical conditions. Such practices aren’t seen in distributor modes or trading company stockrooms.
Traceability isn’t a catchword for us. Each vial’s journey, from input through purification to loading dock, gets documented in both electronic and physical ledgers. Many customers, especially in tightly regulated fields, call for such rigorous tracking. Our focus is not only to comply with protocol, but to build a reputation as a manufacturer others lean on for accountability. Product recall is unheard of in our experience, but redundancies stand by in the documentation systems so that, should anything arise, full chain-of-custody visibility returns answers in real time.
Our workforce doesn’t treat specifications like a formality—they work with a tangible sense of pride in each handled canister. Long stretches on night shift or careful hands during equipment turnover foster a culture that knows cutting corners leads to problems later on. During plant walks, I see operators double-checking reactor seals and sampling lines, pausing to recalibrate meters and note tiny tweaks in process parameters. These habits emerge from faced challenges and collective problem-solving, not from top-down mandates.
Training isn’t just about ticking the compliance boxes. Each newcomer goes through a dual mentorship, shadowing seasoned hands over several campaign cycles. Staff explain the why behind each step—whether it’s slow heating, gradual pH adjustment, or repeated filter washing. When a process shift shows up in analytics, team discussions sort root causes before corrective action rolls out. This hands-on apprenticeship ensures that practical knowledge passes forward, forming a workforce that tackles quality as an everyday undertaking, not just a quarterly audit.
Years of supplying diverse markets guided our present protocols. Exporting to climatic extremes, from humid monsoon zones to dry, cold storage facilities, forced us to stress test both product and packaging. One customer in a desert-adjacent facility reported strange changes to viscosity—analysis traced the cause to slow moisture leaching through packaging, something never obvious in temperate climates. Our response did not stop with a replacement shipment. We changed internal packaging protocols for all exports, marking a clear move from reactive to proactive quality.
A chemical is never just a bottle to us. Each shipment is an extension of our credibility as a manufacturer. Labs trust DDM-222 because we stand by each label. The formulas don’t waver, documentation is open, and expertise stands one call away. We aim to give users the security to tackle ambitious projects while knowing the base chemicals won’t introduce unknowns. DDM-222 shows what happens when a manufacturer brings field experience, operational rigor, and a commitment to industry-best practices together. That’s how we continue to back client innovation, project after project, batch after batch.