|
HS Code |
529770 |
| Chemicalname | 5-Bromoquinazolin-4-ol |
| Molecularformula | C8H5BrN2O |
| Molecularweight | 225.05 g/mol |
| Casnumber | 28340-93-8 |
| Iupacname | 5-bromoquinazolin-4-ol |
| Appearance | White to off-white solid |
| Meltingpoint | 283-287 °C |
| Solubility | Slightly soluble in water, soluble in organic solvents |
| Pubchemcid | 25194082 |
As an accredited 5-Bromoquinazolin-4-ol factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 5-Bromoquinazolin-4-ol, 1g, is supplied in a sealed amber glass vial with tamper-evident cap, labeled for chemical research. |
| Shipping | **5-Bromoquinazolin-4-ol** is shipped in tightly sealed, chemical-resistant containers. It is packed according to international regulations for hazardous substances, with clear hazard labeling. Shipping is via ground or air freight, complying with safety requirements to prevent exposure. Refrigeration or special temperature control is generally not required unless specified by the supplier. |
| Storage | Store 5-Bromoquinazolin-4-ol (Sigma Aldrich/Merck/TCI Chemical Grade) in a tightly sealed container, protected from light, moisture, and incompatible materials. Keep in a cool, dry, and well-ventilated area, preferably at 2–8°C (refrigerator temperature) unless otherwise specified on the label or SDS. Avoid sources of ignition, and always follow institutional safety guidelines for hazardous chemicals. |
Competitive 5-Bromoquinazolin-4-ol prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Working daily in chemical synthesis, the details of every molecule start to matter. 5-Bromoquinazolin-4-ol, known by the CAS number 2922-57-6, shows up with a pale, almost chalky powder-like appearance. In our hands, what stands out right away is its robust crystalline structure and its consistent white to off-white color. We always look for tight melt points in such specialty chemicals, and with this compound, we see a reliable melting range, usually between 232°C and 236°C. Chemists focus on these ranges because subtle shifts speak to purity or even trace contamination.
Testing in our QC lab confirms a purity above 98 percent in the batches coming off the reactor. This matters, not only on regulatory grounds, but for downstream performance. Slight impurities in a building block like this ripple forward, showing up in yields and side products in the eventual API or electronic material. Analytical runs, mainly by HPLC and NMR, back up every certificate we release. Quality here isn’t a sticker on a drum—it's the result of steady, hands-on craftsmanship and rigorous batch sampling guided by years of process experience.
This compound doesn’t belong in the set of commodity chemicals or routine solvent drums. In the research world, you'll see 5-Bromoquinazolin-4-ol regularly show up as a key intermediate for various high-value quinazoline derivatives. Small changes at the 5-position, like the presence of bromine, open synthetic pathways for more custom molecules. Such structures form the backbone for several classes of kinase inhibitors and antitumor agents. Process chemists favor this scaffold since it tolerates diverse functionalizations in subsequent steps, without decomposing or adding unnecessary complication.
In the work at bench scale, where compound libraries grow from small batches, the reactive bromo group at the 5-position turns this molecule into a versatile starting material. Our customers often develop custom heterocyclic frameworks. The hydroxyl moiety at the 4-position adds another axis for modification. In particular, the compound draws interest for Suzuki, Buchwald-Hartwig, and related cross-coupling reactions. The positioning of functional groups means a more direct, efficient build of final molecules—compared to fully unsubstituted quinazolinols, which usually require extra steps.
We noticed this compound drawing more attention from groups shifting away from some older, less selective halogenations. Direct routes to the 5-bromo variant 'clean up' reaction planning and line up perfectly for medicinal chemistry. For an R&D scientist, this means putting more effort into novel functionality instead of wasting time on derivatization pre-steps. It is rewarding to see teams from global pharma and contract research organizations keep circling back, asking about larger batch sizes and custom lot handling. None of this would be happening without tight reaction control and GMP-aligned standards behind every shipment.
Let’s talk numbers and hands-on experience. 5-Bromoquinazolin-4-ol presents as a durable crystalline solid, resisting uptake of atmospheric moisture. This stability saves headaches on storage and handling. Bulk packaging in heavy-walled HDPE or glass keeps it dry, and the low odor profile makes daily handling easier. People in the lab get sensitive to trace smells over time, especially with aromatic bromides, so this absence of pungency is a subtle bonus.
On scales from grams to kilograms, the chemistry remains friendly. Dissolution in standard polar aprotic solvents, like DMF or DMSO, works smoothly. Solubility in less polar solvents drops off, which means care is needed in scale-up reaction planning. In the reaction flask, the bromine offers ready access for Pd-catalyzed coupling, and the hydroxyl group brings flexibility for etherification or acylation directly on-structure. Over years of working with halogenated quinazolinols, we learned that careful monitoring of temperature is key: overheating can brown the sample and start minor decomposition. Good process design with moderate heating preserves yield and keeps downstream purification tight.
Chemists often ask how this compound measures up to other quinazolinols or brominated aromatics on the shelf. Our experience tells us the difference lies in both performance and simplicity. With a clean bromo group directly at the 5-position, reactions proceed with fewer competing side-products than with random halogenations on similar scaffolds. This brings direct benefits for those working under tight purity requirements, where extra purification steps eat up time and lower material yields.
If you look at 4-hydroxyquinazoline by itself, you need multiple reaction steps and risk lower stability when adding halogen atoms later in the synthesis. Many labs notice inconsistent conversions and color changes when handling directly brominated substrates made by uncontrolled methods. We see this in samples sent to us for analysis—off-color, odd melting points, or worse, trace residual halides not picked up by less sensitive testing. Our controlled batch chemistry, honed over hundreds of runs, largely eliminates these risks. Cleaner material in means cleaner results downstream.
Older brominated derivatives for similar applications often come as impure mixtures or are challenging to crystallize directly from reaction mixtures. In contrast, our 5-Bromoquinazolin-4-ol forms distinct and easily handled crystals. This crystallinity also allows for straightforward drying and packaging, minimizing caking or compaction, problems that show up in some other aromatic heterocycles. Feedback from repeat customers highlights that our material remains free-flowing, yet one more sign of purity and batch consistency.
Over the years, we built up a routine for transferring, measuring, and reacting quinazolin-4-ols. Gloves and solid local ventilation always come first. While this compound does not vaporize or outgas aggressively, trace dust—common with fine powders—calls for careful weighing in closed containers. Batch records show nearly zero issues with caking or bridging in drums, so operators spend less time manually breaking up lumps. Long-term storage stability, confirmed by periodic retesting, has proven out to at least 24 months with no drop in HPLC-purity or yield impact in subsequent reactions.
From a reaction design viewpoint, we recommend dissolving it in DMF under gentle stirring for best performance in coupling reactions. Bulk process safety improves thanks to its high thermal stability; the compound resists breakdown at routine pharmaceutical reaction temperatures. During large-scale production, the lack of exothermic byproduct evolution means operators do not run into unpredictable pressure swings—this is a real concern with some less stable bromoaromatics.
Years in this business taught us that clean chemistry must extend all the way to waste management. Our facilities treat all mother liquors and tank rinsate with care, capturing and neutralizing dilute bromides before anything heads to waste. Internal EHS audits always watch for emerging regulatory trends, especially as new halogenated chemicals come under tighter scrutiny. None of our 5-Bromoquinazolin-4-ol batches leave the plant unless every batch matches documentation for both purity and trace metals—customers working in human therapeutics require clean certificates, and our export partners count on full compliance.
Our technical staff keeps a close eye on local, national, and global listings for restricted substances. For users in regulated industries, we provide clear reporting on synthesis route, batch traceability, and raw material origin. Experience shows this transparency saves troubleshooting time down the line and supports faster regulatory acceptance in new drug filings and related applications.
Scaling up from gram experiments to kilogram runs uncovers new challenges each time. For 5-Bromoquinazolin-4-ol, particle size distribution often comes up as a point of concern. Overly fine powders can make material handling frustrating, leading to airborne loss and sticky residues on glassware. Through steady process refinement, we dialed in filtration and drying steps that consistently yield mid-sized crystals, favoring both rapid filtration and safe transfer.
Customers sometimes report batch-to-batch color shifts when sourcing from less controlled suppliers. We addressed this by running detailed color index and ultraviolet absorbance tests on all finished material. Every change in hue prompted a review—tracking back to new lots of raw materials, or small temperature drifts in bromination. Our aim with process adjustments is to lock in color and material flow year-round, so downstream processes do not face unexpected unknowns.
Shipping bulk material poses another challenge, especially for international orders. Customs authorities and end-users require precise, non-generic answers to questions about synthesis, trace metals, and even plant water sources. We keep detailed production records and can match fingerprint spectra batch by batch. Through years of regulatory inspections, we have seen the benefit of direct communication and rapid retrieval of technical data when something, even outside our control, triggers a snag in customs or blocks a project’s schedule.
5-Bromoquinazolin-4-ol serves as a puzzle piece for modern medicinal chemistry and advanced material synthesis. Direct feedback from project teams tells us that using clean, well-characterized starting material saves both time and budget in drug development. With every new delivery, the research teams count on the ability to move directly into cross-coupling or condensation procedures, skipping unnecessary purification cycles. The result is a shorter path from idea to assay, or from synthetic proof to functional device.
Unlike generic halogenated aromatics, this compound’s structure allows for site-specific elaboration without extensive protection-deprotection steps. Some customers highlight the direct formation of ureas, amides, and even spirocyclic quinazoline frameworks as key advances enabled by our product’s chemical profile. In fields like oncology drug discovery, this means researchers work closer to the 'design-make-test' cycle at every iteration.
Moving from lab scale to full-scale manufacturing calls for more than just bigger equipment. We invested in process intensification, reducing solvent volumes and minimizing waste wherever practical. Cleaner reactions mean less to scrub from the equipment, more uptime, and fewer gallons in the waste stream. Mature reaction monitoring—using GC and real-time IR—lets us catch problems before they snowball into lost batches.
Batch reproducibility stands as our main selling point. After repeated runs, our technical teams noticed tight clustering of melt points and NMR signals, confirming that scale-up did not introduce impurity drift. Downstream purification in client plants moves faster because we deliver fewer byproducts and a more consistent melting range batch after batch. Teams handling API syntheses, for instance, find they hit their reaction endpoints reliably because the starting material arrives with known, stable properties.
Operators at multiple sites have reported that our material stands up well under process conditions, with no degradation seen even in demanding oxidative or reductive environments. This robustness flows from careful raw material inspection and continuous operator training, reducing downtime and unplanned maintenance at client facilities. With many partners now seeking green chemistry certification, our reduction in unnecessary halogenated solvents during synthesis marks out a path to compliance with evolving sustainability benchmarks.
Our technical service team handles a regular stream of requests for advice on maximizing yields with 5-Bromoquinazolin-4-ol. Common issues include diminished yields due to over-drying the material—resulting in minor thickening or agglomeration—and unexpected solubility barriers during coupling reactions. We recommend controlled vacuum drying at mild temperature settings. Overly aggressive conditions can lead to subtle color and property shifts, which, even if not immediately obvious, impact long-term material performance.
Solubility can vary in user hands, sometimes linked to slight batch-to-batch moisture content or variations in solvent quality. For consistent results, we guide customers to pre-wet with a minimum amount of DMF or DMSO for initial dissolution, gradually diluting to target concentration instead of dumping solid directly into a large solvent flask. This technique, often overlooked in high-throughput labs, improves full dissolution and overall reaction completeness, especially for complex cross-coupling sequences.
Handling dust generation during weighing is another concern raised by process users. Practical experience shows that slow, deliberate pouring and use of anti-static scoops helps avoid airborne loss, which in turn keeps batch tracking straightforward for QC accounting. Packaging in narrow-neck bottles or bags further lowers risk, especially compared to broad open drums with older designs.
Experiments and scale-ups carried out over many years built confidence that high-purity 5-Bromoquinazolin-4-ol sets up customers for both reliable lab work and streamlined scale-up. Batch documentation, retention samples, and full spectral data stay on hand for every lot. This means faster troubleshooting, should unusual results arise or if a regulatory agency requests a deep dive on origin and trace contaminants. The analytical data from our end—from melting points and HPLC purity to full 1H/13C NMR and trace metals—has supported filings in both the pharmaceutical and electronics sectors.
In pharmaceutical research, consistent access to well-defined intermediates has sped up SAR analysis and allowed clinical candidates to move through development phases with fewer interruptions. We follow regulatory changes carefully so our documentation and lot records remain audit-ready. For advanced materials work, like organic semiconductors and specialty pigments, uniformity in starting batches directly translates to fewer defects in finished devices.
The need for reliable, well-characterized specialty chemicals continues to grow. Our direct role in manufacturing gives us insight into changing project needs—whether that means supplying a gram-scale for early-stage research or scaling up quickly for a new drug or device platform entering trials. Core capabilities like rapid analytical turnaround, steady process improvement, and full supply chain traceability enable us to act as a steady partner as demands shift.
Requests for new derivatives based on the 5-bromoquinazolinol skeleton continue to expand. By controlling core chemistry tightly, we find we can branch out into custom functionalization for specific industrial and therapeutic requirements. Each step from raw material through final drum or flask is tracked, optimized, and reviewed, not only to meet regulatory needs, but to beat customer expectations for reliability and support in a fast-moving global marketplace.
Working in the trenches as a manufacturer, attention to detail at every stage—reaction design, production, quality testing, and shipment—makes all the difference. 5-Bromoquinazolin-4-ol stands as a testament to how thorough manufacturing practices, driven by years of practical experience, deliver benefits flowing far beyond our factory walls. The next advance in medicinal chemistry or electronic materials may well start with a single, carefully prepared small jar of this distinctive compound, and we're proud to enable that next step forward.