|
HS Code |
861196 |
| Chemical Name | 4-Chloro-8-fluoroquinazoline |
| Molecular Formula | C8H4ClFN2 |
| Cas Number | 321-82-0 |
| Appearance | White to light yellow solid |
| Melting Point | 116-118°C |
| Solubility | Slightly soluble in water; soluble in organic solvents |
| Smiles | C1=CC2=NC=NC(Cl)=C2C(=C1)F |
| Inchi | InChI=1S/C8H4ClFN2/c9-8-5-2-1-3-6(10)7(5)11-4-12-8/h1-4H |
| Purity | Typically >97% (may vary by supplier) |
| Storage Conditions | Store at 2-8°C, protected from light and moisture |
| Synonyms | 4-Chloro-8-fluoro-quinazoline |
As an accredited 4-Chloro-8-fluoroquinazoline factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 4-Chloro-8-fluoroquinazoline is supplied in a 5-gram amber glass bottle with a tamper-evident seal, labeled with safety information. |
| Shipping | 4-Chloro-8-fluoroquinazoline is shipped in sealed, chemical-resistant containers under ambient conditions. Packaging complies with standard laboratory safety regulations. The compound is classified as non-hazardous for air and ground transport, but it should be handled with care upon receipt. Documentation and safety data sheets are provided by Sigma-Aldrich, Merck, or TCI Chemical. |
| Storage | 4-Chloro-8-fluoroquinazoline should be stored in a tightly closed container, in a cool, dry, and well-ventilated area away from incompatible substances such as strong oxidizers and moisture. Protect from light and sources of ignition. Store at room temperature as specified by Sigma Aldrich, Merck, or TCI. Follow standard laboratory chemical storage protocols and label appropriately. |
Competitive 4-Chloro-8-fluoroquinazoline prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
At our facility, we do not view 4-Chloro-8-fluoroquinazoline as just another reagent; we see it as a product grounded in a chain of tightly controlled chemical transformations. From early synthesis steps through final purification, our workflows draw on decades of practical process chemistry and insight into electronic and steric effects. We’ve worked out where reaction bottlenecks lie, how to mitigate in-process contamination, and the best approaches to both isolate and dry this compound without altering its crystalline integrity. Under the hood, each lot we deliver reflects thousands of hours spent narrowing down conditions that yield consistent granularity, purity, and trace profile. We have long since stopped relying on guesswork or legacy protocols from textbooks or open literature. Experience with inter-batch variation and scale-up has taught us the difference between convenient process claims and operational reality.
Each batch leaves our plant with a certificate that bases its numbers only on observed lab data, not marketing promises. We routinely achieve high-purity lots, with typical assay values above 98% as determined by validated HPLC methods. Moisture and volatile residue measurements come from direct Karl Fischer titrations and TGA, not extrapolation. Our environmental controls—down to air handling, temperature regulation, and solvent recovery—aren’t performed as afterthoughts or “nice to have” features, but fundamentals. Particle size distribution for 4-Chloro-8-fluoroquinazoline, which can influence solubility and handling, is something we monitor and adjust for each run. By tracking impurity thresholds using high-resolution mass spectrometry and NMR analysis, we avoid any downstream headaches, especially those that come up when the product serves as a building block for more sensitive applications in pharmaceuticals or electronics.
From the earliest days of scaling this compound, we found that end users need more than purity printouts. Researchers and formulators in our customer base focus on reactivity patterns and compatibility with a series of ring closure, substitution, or condensation steps. Our technical liaisons stay in contact with developers and engineers hoping to drive more robust processes, rather than simply optimizing for short-term yield. For those in drug discovery, the introduction of both chloro and fluoro substitutions on the quinazoline core opens up a landscape of selectivity and metabolic stability different from the classical unsubstituted quinazoline. We see this compound commonly used in early lead scouting or for generating intermediates for kinase inhibitors, antiviral scaffolds, and other aromatic heterocyclic targets.
Industrial users—particularly those seeking to build up more complex fused ring systems—often comment on the reactivity of the 4-chloro position, which acts as a versatile handle for substitution. Lab-scale chemists devote their attention to nuances in nucleophilic aromatic substitution reactions; our plant staff have learned, often the hard way, what it takes to ensure residues of starting materials or side products don’t persist to cause chromatographic challenges downstream. The fluorine at the 8-position brings another layer of stability and alters π-electron density, which can significantly change downstream reaction routes. Many customers benefit not simply from the raw material, but from our guidance on solvent choice, workup, and quenching, which draws on observed behavior over thousands of liters of processed material.
We often get inquiries about the differences between 4-Chloro-8-fluoroquinazoline and familiar compounds like 4-chloroquinazoline, 8-fluoroquinazoline, or other dihalogenated quinazolines. After grinding through hundreds of kilo-scale synthesis cycles, we can say with confidence that these molecules are not interchangeable, and subtle adjustments in electrophilicity or aromaticity matter. The introduction of two electronegative groups at precise sites changes reactivity patterns—some routes become possible only with the dual halogenation, others shift markedly in yield or selectivity.
From a manufacturing lens, the presence of both chloro and fluoro substituents means we have to use careful stoichiometry and select conditions to avoid over-chlorination, ring opening, or decomposition. Our early batch trials exposed issues with side-chain scrambling and incomplete halogenation—issues missed in small-scale literature recipes. Solvent effects, temperature ramps, and order of reagent addition are all major factors we adjust not in isolation, but as part of an iterative feedback loop running between R&D and plant operators. We have observed that some downstream chemists try to cut corners with lower-purity feedstocks. That approach often ends up costing far more—in troubleshooting, rework, and failed assays—than a focus on initial batch consistency.
We document trends in how impurity profiles shift when both halogen groups are present. The presence of over-halogenation, unwanted isomers, or persistent starting materials becomes more likely if synthesis conditions are not tightly maintained. Our feedback from users in medicinal chemistry, particularly those with strict pharmacopoeia requirements or regulatory oversight, reinforces the value of a clean, well-documented source. We have refined upstream monitoring and purification not only to improve optical clarity or powder flow, but, more importantly, to reduce batch-scale variability that laboratories and production lines cannot afford.
Each customer application presents its own headaches, but years of real-world troubleshooting have led us to rethink assumptions. For instance, shipping delays or unexpected storage conditions are realities we have encountered more than once. Based on this, we have optimized packaging specifically to limit moisture uptake and chemical instability—a step that laboratory users sometimes overlook until a problematic analysis occurs. Our batches are routinely retested after mock storage periods and simulated long transports, so customers can rely on performance even after weeks in varying climates. This is not just marketing—it’s the result of real shipment reviews and site visits, not third-party claims.
Having direct conversations with downstream process chemists and procurement managers, we’ve learned how important traceability is when a process depends on supply predictability. Some of our customers run campaigns for months, so we maintain lot continuity, sample archiving, and detailed batch histories—practices born out of regulatory requirements and industry audits. Our technical support extends beyond standard paperwork and includes process optimization help and ongoing feedback, reflecting our long-term perspective.
One key lesson is that users need flexibility—whether in pack sizes or delivery lead times. Instead of dictating scheduling from a desk, we coordinate closely with inventory planning on both ends, taking into account swings in production or R&D priorities. This responsiveness emerges from direct partnerships—we listen to actual feedback, unmatched by third-party trading platforms or intermediaries, and adjust schedules in real time.
Customers who reach out to us expect clarity about material origins, full batch documentation, and technical transparency. Our plant logs connect synthesis right down to the tank level. Any out-of-spec results are documented and explained—not buried or brushed aside. With a compound like 4-Chloro-8-fluoroquinazoline, where small shifts in impurity or form can derail a project, we do our best to provide certificates based on what actually comes off our line, not what sounds best to marketing directors. We compare our practices to regulatory checklists and often go beyond them, precisely because we’ve seen audits catch things that paperwork alone cannot. Our R&D staff regularly attend industry briefings and share learning with production crews directly, making sure lab insights translate to plant scale realities.
Our process development team faces consistent pressure—not from external regulation alone, but from our own desire to minimize impact and operational risk. Volatile organic solvent management, chlorine capture, and energy recovery come from direct investments, many initiated before they became common practice. We keep waste streams as predictable and closed as possible, and maintain records that stay open to outside review. By recycling solvent and analyzing waste for residual product, we cut down on both environmental load and uncontrolled losses. Lessons from early campaigns, where material loss and untracked exhaust led to both economic and safety risks, have shaped our drive to run cleaner and leaner operations.
Staff training programs focus on both safe handling and real-world accident scenarios drawn from industry case histories, not just in-house simulations. We share safety learning and process improvements not only with our internal team, but also with long-term partners through joint working groups and site visits. Constant inspection and process review are not relegated to annual checklists or outside auditors; they are concrete parts of our daily management.
Feedback informs everything—from batch scheduling to packaging updates. Recently, updated reports from production scientists in the field flagged clumping during high humidity exposure. We traced the cause to packaging micro-defects invisible during routine plant checks, revised sealing specs, and implemented double-fail verification. This outcome was not prompted by a recall or regulator’s nudge, but by our open-door policy and willingness to take all user concerns seriously.
By keeping our technical and quality teams in direct contact with application chemists, we spot problems early. Some of the most important improvements in our 4-Chloro-8-fluoroquinazoline process have come from these interactions—changes in crystallization, packaging, and analytical follow-up weren’t planned on PowerPoints, but evolved from dialog and technical support exchanges. Our experience shows that silos between production, R&D, and real-world users block solutions before they begin to take shape.
In pharmaceutical and fine chemical environments, change comes not just from innovation, but also from shifting regulatory landscapes and detailed safety reviews. We stay on top of evolving guidance documents and impurity regulations, updating our methods and documentation in response to real regulatory feedback. Our QA and compliance officers take part in working groups and keep production smooth during rollouts of new standard operating procedures. Our customers know we adapt quickly, transparently, and with as little process disruption as possible.
Sometimes, technical or legislative shifts force new directions in chemical manufacturing. We invest heavily in system redundancy and process documentation, not just to box-check but so that we can keep customers supplied, even in changing environments. Our technical archives and records go back years, giving us the data we need to demonstrate both product consistency and clear root cause analysis in the event of a process upset.
As applications for halogenated quinazolines diversify and expand into new markets—such as advanced materials and targeted therapeutics—we continue to strengthen our analytical systems and traceability models. We see increased demand not only from pharmaceutical synthesis but also from innovators in electronics, where tight controls over trace impurities have become critical. Collaborating directly with partners in new application spaces helps us forecast changes and build the capacity and documentation they require.
Through regular investment in equipment, ongoing skills development for our staff, and direct feedback loops to customers, we maintain the flexibility and technical insight to keep supply lines running. We anticipate that new routes and innovations—especially in green chemistry, downstream modification, and rapid prototyping—will push future specifications. Our commitment remains: no shipment leaves our doors unless it reflects both the practical realities of daily production and the technical demands of high-precision synthesis.
4-Chloro-8-fluoroquinazoline stands as both a reflection of practical manufacturing experience and a critical enabler of next-generation chemical research. Each decision we make traces back to real events, measured results, and honest conversations—not marketing catchphrases or abstract promises. For customers who value supply consistency and technical partnership, our commitment is simple: deliver reliable product, backed by people who know what goes into every batch, and who stand ready to troubleshoot, adapt, and improve with every cycle. As demand grows and standards rise, we promise our best—every shipment, every time.