|
HS Code |
410461 |
| Product Name | 3-Bromo-5-fluoro-4-methoxyaniline |
| Cas Number | 886372-35-0 |
| Molecular Formula | C7H7BrFNO |
| Molecular Weight | 220.04 |
| Appearance | Light brown solid |
| Purity | Typically ≥98% |
| Solubility | Soluble in organic solvents (e.g., DMSO, methanol) |
| Smiles | COC1=C(C=C(C=C1F)Br)N |
| Inchi | InChI=1S/C7H7BrFNO/c1-11-7-4(10)2-5(8)3-6(7)9/h2-3H,10H2,1H3 |
| Synonyms | 3-Bromo-5-fluoro-4-methoxybenzenamine |
| Iupac Name | 3-bromo-5-fluoro-4-methoxyaniline |
As an accredited 3-Bromo-5-fluoro-4-methoxyaniline factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Sigma Aldrich’s 3-Bromo-5-fluoro-4-methoxyaniline is supplied in a 1g amber glass bottle with a secure screw cap. |
| Shipping | 3-Bromo-5-fluoro-4-methoxyaniline is shipped in tightly sealed containers from suppliers such as Sigma Aldrich, Merck, or TCI, ensuring protection from moisture and light. Packaging complies with safety regulations for hazardous chemicals, often including secondary containment and relevant documentation for safe, secure transit via ground or air, depending on destination. |
| Storage | 3-Bromo-5-fluoro-4-methoxyaniline should be stored in a tightly sealed container, kept in a cool, dry, and well-ventilated place away from incompatible substances such as strong oxidizers. Protect from light and moisture. Follow standard lab chemical storage procedures and local regulations. Store at ambient temperature unless otherwise specified by the manufacturer (Sigma-Aldrich, Merck, TCI). Use appropriate personal protective equipment during handling. |
Competitive 3-Bromo-5-fluoro-4-methoxyaniline prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
On the shop floor, every batch of 3-Bromo-5-fluoro-4-methoxyaniline reflects attention to detail that starts long before the raw materials reach the reactor. Order volume for this molecule has steadily increased as its relevance in advanced pharmaceutical intermediates and active ingredient synthesis grows. Colleagues in research labs value this compound for both scaffolding and late-stage functionalization steps, especially where bromo and fluoro substituents deliver superior selectivity.
We’ve standardized our model as CAS 1019906-60-1. Specifications came out of years of hands-on process development rather than just referencing paper values — our chemists asked for GC purity typically over 98%, water content checked down with Karl Fischer titration, and a consistent pale beige crystalline solid as the benchmark for visual quality control. Each run puts us face-to-face with the idiosyncrasies of brominated and fluorinated aromatics. Inconsistent raw materials can sneak in unwanted halide byproducts, so sourcing and incoming inspection hold more importance than most realize.
Safety enters every discussion at production scale. The methoxyaniline backbone offers some stability, but the adjacent electronegative bromine and fluorine atoms add their own quirks. Overheating leads to charring and color changes, with exotherms during coupling. We’ve tuned our process to control temperature ramps tightly and use modern condenser systems to capture and scrub off gases, not simply to meet compliance, but because we rely on operators to run the floor daily, and their health is never a traded variable.
The differences between 3-Bromo-5-fluoro-4-methoxyaniline and close relatives, such as non-substituted methoxyanilines or bromofluoroanilines with different aromatic ring substitution, play out in both lab and industry. The position of each substituent on the ring changes not only the electron density but also the compound’s reactivity in coupling and condensation reactions. Chemists in both custom synthesis and process development know these differences can mean fewer side products, less column time, or a smoother scale-up. While 3-bromo-5-fluoro-4-methoxyaniline balances reactivity with stability better than some positional isomers, a clear route for purification keeps it commercially viable.
Our team goes hands-on with analytical methods at every step. NMR, HPLC, GC-MS, and melting point – these become part of the background rhythm. There’s a legend in the industry that everything starts to look the same on paper, but subtle impurities can shift the melting point or spike the baseline unexpectedly. After years of first-hand troubleshooting, we value instrument calibration and detailed logging as much as the actual reaction yields.
Why do people come back for this compound instead of trying to substitute with other arylamines? It’s not simply about the presence of bromo, fluoro, and methoxy groups but how they interact. The methoxy group tweaks solubility, important both in process tanks and in downstream product formulations. Bromine at the 3-position makes it a preferred partner in Suzuki or Buchwald-Hartwig couplings, giving downstream synthetic chemists flexibility for alkylation or further substitution. The 5-fluoro atom nudges things just enough to change electron density, often producing higher selectivity for follow-on reactions leading to pharmacologically interesting motifs. From first-hand project debriefs, we rarely see this combination behave exactly as a sum of its parts; it brings an advantage for specific blocks in agrochemical or oncology research.
One trajectory we’re seeing more of is the focus on impurity profiles. Thanks to more demanding regulatory trends, every batch now includes targeted screening for heavy metals and residual solvents as standard, not just as a one-time validation. Meeting these standards means tighter process control, with a trickle-down effect driving even suppliers to improve their own quality routines. We’ve adopted inline spectrometry and LC-MS for spot checks, letting floor leaders detect deviations earlier. Experience teaches brutal lessons: even a trace residual solvent can derail downstream hydrogenation or lead to sticky residues in post-reaction work-up. Day to day, these inspections take time, but the finish-line is worth it — fewer customer returns, stable supply chains, and reliability for formulators further down the chain.
Within the supply chain, scale makes more difference than any spec sheet will say. Multi-kilo synthesis means working with reactor fouling, heat transfer, and waste abatement as a living reality. The presence of both bromine and fluorine increases handling complexity. Operators report that these jobs are never as “clean” as benchtop demo runs; you only appreciate the behavior of 3-bromo-5-fluoro-4-methoxyaniline after draining a glass-lined reactor and seeing which residues flush without clogging filters or heat exchangers.
From the research feedback loop, those buying from us mention high batch-to-batch consistency, especially in critical steps involving cross-coupling or downstream diazotization. We learned not to chase superficial color uniformity but to correlate every physical change with analytical data. Some commodity lines focus on throughput and margin, but we keep a robust sample retention bank, pulling random vials months after shipping. Running new analytics on retained samples gives clues for process drift, so we can trace issues to their source rather than guessing.
Taking upstream changes into account, our continuous improvement team investigates new sources of 4-methoxyaniline and halogenating reagents. Sourcing impacts footprint. Years back, overly aggressive bromination led to regulatory flags due to excess bromide waste; these lessons prompted a switch to greener reagents and solvent recovery loops. Regular cycle audits even look at utilities and steam demand, since energy efficiency directly relates to factory output and sustainability targets.
It’s not unusual for project managers to call with questions ranging from batch documentation to shelf-life under humid conditions. We often run stability studies for repeat pharmaceutical partners, storing samples under different humidity and temperature settings. In hot, damp conditions, 3-bromo-5-fluoro-4-methoxyaniline has shown resilience, with only slight yellowing at extremes but little change in HPLC purity. Proper packaging — double PE liners, nitrogen flashes, and secure drums — make the most difference during sea transit.
On the applications side, our best conversations occur with in-house medicinal chemists who treat these halogenated methoxyanilines as toolkits for unlocking tough bond formations. They frequently take our product through etherification, acylation, or protected amination, targeting core units in kinase inhibitor scaffolds or fluorinated benzazoles. For their work, minor variances in the methoxy or fluorine content translate into large swings in bioactivity. We aim for tight control in every lot, saving everyone downstream from iterative trouble-shooting or unnecessary retesting. Years in the field revealed that reliable, well-characterized intermediates advance projects past the synthesis bottleneck.
Formulation teams further down the value chain sometimes ask what drives product selection over similar “off the shelf” arylamines. Very often, it’s about how the substituents help build out advanced molecules. The 3-bromo group is especially reactive toward palladium-catalyzed couplings, not as sluggish as a 2-bromo isomer and less likely to trigger unwanted side reactions than 4-bromo, where steric drag dulls reactivity. A methoxy at the 4-position participates in both hydrogen bonding and electron donation, making downstream functionalization more predictable and boosting compatibility in polar organic solvents. 5-fluoro resists deactivation and has proven invaluable for selectivity in many transformations where older aniline derivatives could not deliver clean outcomes.
We’ve seen an uptick in inquiries from biotech researchers starting with this intermediate for early-phase development of new enzyme inhibitors or diagnostics. Several collaborative projects used this scaffold for further elaboration into PET imaging agents, benefiting from the fluorine label and the compound’s amenability to late-stage modifications. With longer shelf stability and consistent reactivity, teams push screening programs or scale-up synthesis with lower risk of batch rework.
Production veterans point to process robustness as their key performance measure. With the added complexity of handling both bromine and fluorine species, we reinforced exhaust hoods and worker protection, updating standard procedures for transfer, cleaning, and waste handling. Serial work-ups with activated carbon and secondary washes cut colored byproduct traces, ensuring a cleaner crystalline product out the door. New process controls carve out a safety buffer—any process drift, such as sluggish agitation or unusual exotherms, triggers batch hold pending supervisor review.
From the regulatory standpoint, traceability underpins our operations. Each lot ships with a full Certificate of Analysis, now accompanied by more granular impurity and origin data. Doing so doesn’t just tick a compliance box; it answers customer questions arising from increasing scrutiny over supply chain transparency and data integrity. We found early on that generic, “meets spec” answers seldom satisfy audits; sharing deeper origin and analytical logs provides a better foundation for mutual trust.
On the shop floor, operators adapt quickly to any process tweaks, often suggesting improvements overlooked in the engineering files. For 3-bromo-5-fluoro-4-methoxyaniline, efficient power washing and solvent recovery after batch draining can cut downtime between runs. Continuous reinforcement on glove and mask use, particularly during product charging and packaging, maintains safety outcomes and meets outside audit requirements. Leaning into these routines lessens long-term exposure and becomes a quiet source of pride among the crew.
We see the practical advantages of this product extend to custom synthesis firms as well, where downstream transformations into elaborate heterocyclic cores, dye precursors, or functionalized monomers remain high-volume routes. Because few alternatives offer a similar blend of halogen and methoxy functionality at these precise ring positions, we keep a technical dialog open with formulators tackling specific cross-coupling or electrophilic aromatic substitution steps. Sharing real plant data on solubility, melting behavior, and filtration rates gives these partners a leg up when scaling from lab to pilot plant.
Logistics plays a silent but critical role in ensuring product integrity. Humidity and shipping temperature watchlists grow every year. We moved from basic fiber drums to layered liners, vacuum-packed or nitrogen backfilled, after seeing surface discoloration develop on samples exposed during long customs holds. Loading teams check drum seals using in-house leak tests before every international consignment. The results: lower claims and fewer re-tests on arrival.
Every synthesis brings in stories that process documentation alone can’t capture. Teams have clocked everything from temperature-induced color shifts to rogue solvent flashes and stubborn cake formation. Regular “post-mortem” reviews with all shift leaders let us spot recurring weak points and share fixes across production and QA. Small-scale tweaks—longer agitation, alternate solvents for crystallization—get tested in the pilot plant before any full-scale adaptation. This tight operational feedback keeps us evolving faster than clipboard audits.
From a business continuity angle, more buyers factor in our real-world problem solving as part of the purchasing equation. Persistent QA follow-ups, direct communication during storm- or pandemic-related delays, and live analyst support in times of batch deviation matter just as much as price or turnaround. Somewhere between the data and the delivered drum, relationships are built on pragmatic knowledge and troubleshooting, not hands-off fulfillment.
Trace impurity reduction remains a recurring theme. A move from older halogenation agents to lower-residue, eco-friendlier alternatives not only brought down environmental impact, but cut out organohalide “ghosts” that used to confound QA checks. Downstream, buyers gain reactant flexibility, cleaner workup experiences, and safer endpoints. As audit standards tighten each year, visible improvement in purity outcomes and analytical reporting boosts credibility even with new-to-us buyers.
Projects change, but tight analytical rigor sticks around. We back every batch with a log of critical process parameters. Real analytical spectra accompany every lot, with customer feedback loops helping us fine-tune for persistent noise or impurity signals. Early and consistent feedback from users keeps our specs practical, not academic. Dashboard-driven process monitoring, originally an experiment, now lives as a fixture on our plant room wall, where everyone from operators to line managers tracks in real time.
Shelf-life and storage come up most frequently from formulation and procurement teams. By running real-time and accelerated aging studies, we built a track record for long-term integrity, even under high-heat or tropical shipping. Operationally, this translates into peace of mind for teams buying drums months in advance for multi-stage programs. Robust packaging, plus real chemistry behind the product’s limited hygroscopicity and low volatility, save customers headache during storage and withdrawal.
On-site teams constantly search for incremental improvements. One team modified agitation speeds and tank baffle geometries to cut precipitate formation, while another introduced portable IR for drum inspection to catch potential moisture ingress before QC analysis. These changes string together across the value chain, reducing both factory rework and external delays.
True product value emerges from years invested in production discipline and hands-on partnership with users. 3-Bromo-5-fluoro-4-methoxyaniline, as we make and ship it, embodies these lessons—a high-purity compound with nuanced handling, sharpened controls at every step, and open feedback lines to customers who demand reliability over hype.
From scale-up to shipping, our approach reflects practical adaptation and respect for experience on the ground. With the ongoing pace of innovation, especially in pharmaceutical and specialty chemical sectors, demand for well-characterized, consistently manufactured materials pushes us to keep learning from every batch, every feedback call, and every process hiccup. These shared lessons transform 3-bromo-5-fluoro-4-methoxyaniline from a line on a catalog to a trusted tool for real-life breakthroughs.