HS Code |
601840 |
| Product Name | 3-(4-Bromo-2-fluorophenyl)propanoic acid |
| Cas Number | 328230-48-0 |
| Molecular Formula | C9H8BrFO2 |
| Molecular Weight | 247.06 |
| Appearance | White to off-white solid |
| Purity | Typically >98% |
| Solubility | Slightly soluble in water; soluble in organic solvents (e.g., DMSO, methanol) |
| Smiles | C1=CC(=C(C=C1Br)CC(=O)O)F |
| Inchi | InChI=1S/C9H8BrFO2/c10-8-3-1-7(11)6(4-8)2-5-9(12)13/h1,3-4H,2,5H2,(H,12,13) |
| Storage Conditions | Store at 2-8°C, tightly sealed, protected from light |
| Synonyms | 4-Bromo-2-fluoro-3-phenylpropanoic acid |
As an accredited 3-(4-Bromo-2-fluorophenyl)propanoic acid factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 3-(4-Bromo-2-fluorophenyl)propanoic acid, 5g, supplied in a sealed amber glass bottle with tamper-evident cap, labelled Sigma-Aldrich. |
| Shipping | 3-(4-Bromo-2-fluorophenyl)propanoic acid is shipped in tightly sealed, chemical-resistant containers, following hazardous material regulations. Transport is via certified carriers with appropriate documentation and labeling. Packaging complies with safety standards to prevent leaks or contamination. Shipping temperature and handling instructions are provided per Sigma Aldrich, Merck, or TCI requirements. |
| Storage | Store **3-(4-Bromo-2-fluorophenyl)propanoic acid** in a tightly sealed container, in a cool, dry, and well-ventilated area away from incompatible substances (such as strong oxidizers). Protect from light and moisture. Recommended storage temperature is 2–8°C (refrigerated). Always follow the manufacturer’s safety data sheet (SDS) instructions and use proper personal protective equipment when handling the chemical. |
Competitive 3-(4-Bromo-2-fluorophenyl)propanoic acid prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every batch of 3-(4-Bromo-2-fluorophenyl)propanoic acid starts with fully qualified raw materials and tracked synthetic steps governed by rugged in-house controls. Having operated from bench to pilot scale with this intermediate for over a decade, our approach reflects more than routine manufacturing—we see firsthand the positive impact when consistency matters in a synthesis route or during ongoing optimization.
We monitor the whole process ourselves, paying attention to details that change outcomes: accurate molar ratios, reaction temperatures held steady, organic phase clear of residual impurities, and no shortcuts at workup. Each specification in the product sheet traces to practical hurdles we faced and solved. For example, we have invested heavily in modern purification columns and analytical equipment just for this fluorobromoarene line, after experiencing product drift and color variation ourselves when relying on open-vessel extractions.
Current lots consistently show a solid, white to off-white powder, with assay values commonly exceeding 98% by HPLC, a reflection of careful adherence to reaction timing and post-process drying under controlled humidity. The melting point ranges cited in our batch records offer a quick screen for purity and form identification, but our real focus is minimizing contaminants that actually hurt downstream chemistry—aromatic isomers, residual halides, and hydrolyzed byproducts are all kept far below actionable thresholds.
From the beginning, we challenged early batch protocols, refining crystallization solvents and drying times after screening over a dozen trial runs. Some competitors cut corners on solvent recovery or permit marginal tolerance for colored impurities, and in certain synthesis routes, users reported inconsistent yields, especially in scale-up experiments. We revisited every step, from bromination selectivity to fluorination sequence, enforcing standards that cut across all operational roles—research chemists and batch operators are trained in the same troubleshooting patterns, cross-check product at intermediate stages, and share feedback on isolated yield, not just paperwork specifications.
Our quality assurance draws on repetition and chronic evaluation. Every drum labeled for dispatch has been tracked from incoming raw material to finished powder, and we maintain precise internal logs linking every stage of production to sample retention. Spectral data, whether proton NMR, LC-MS, or FT-IR, is not just scanned for compliance, but reviewed for subtle hints—a shifted doublet in NMR, a hidden minor component in HPLC traces, anything that might complicate a medicinal chemist’s story or throw off chiral separation further downstream. Since some requests arise for very high purity material, we designed auxiliary purification steps that avoid silica-based contaminants, knowing a few micrograms of extraneous silica can add weeks of troubleshooting for discovery chemists.
The vast majority of 3-(4-Bromo-2-fluorophenyl)propanoic acid made here goes into pharmaceutical research or advanced materials design. Our clients synthesize alkylated aryl derivatives, linkers for peptide conjugates, or explore new active scaffolds. Having tested this intermediate against dozens of possible halogenated analogs, the pattern is clear: the unique substitution pattern on this ring positions it for building block compatibility missing in closely related compounds. The para-bromo and ortho-fluoro arrangement increases the scope for selective cross-coupling reactions, often enabling precise Suzuki or Buchwald-Hartwig reactions that would stall with meta arrangements or dual halogenation elsewhere.
Medicinal chemists often want to compare this acid with variants like 3-(2-fluorophenyl)propanoic acid or 3-(4-bromophenyl)propanoic acid. Based on our ongoing feedback from early-phase project teams, the dual halogen motif is especially attractive for modulating electronic properties or engaging in structure-activity searches. The ortho-fluorine atom tweaks acidity and reactivity without bringing in unwanted steric loading. Para-bromination, on the other hand, opens a robust point of attachment via well-established cross-couplings. While meta- or ortho-bromo versions sometimes cause steric problems or introduce extra handling risks, this substitution pattern keeps things manageable for tightly controlled upstream libraries.
Some research groups choose our 3-(4-Bromo-2-fluorophenyl)propanoic acid for its long shelf life under properly sealed conditions. Packed in sealed foil or inert containers with carefully logged humidity monitoring, current stability data extends past 24 months, with no visible color change or degradation in HPLC profiles. Our technical support receives few queries about stability, but our team investigates any off-notes in odor or unexpected melting point fluctuations with a direct line to production and analytics.
Every halogenated propanoic acid has its role, but lab experience teaches the value of careful substitution. The presence of a para-bromo and ortho-fluoro increases the range of downstream transformations. Cross-couplings are more predictable, and less risk of side reaction emerges compared to difluoro or dibromo species. Many users attempt to make do with related acids, but then confront challenges: unwanted isomers, uncooperative solubility, or sticky byproducts in chromatographic work-up.
Since we employ only halide sources approved for pharmaceutical intermediates, each step favors low levels of trace mineral or transition metal contamination. We independently verify all transition metal content by ICP-MS, supporting teams bound to ultra-trace metal limitations in GMP environments. Not all suppliers do this as a matter of course; we started because pilot-stage projects often ran into final API release problems traced back to overlooked upstream impurities. Our plant layout keeps halogenated waste and reaction venting separated from clean storage, and we provide full documentation to repeat every step taken if clients seek audit or regulatory inspection.
The synthesis route we use has evolved through customer conversations and careful failure analysis. We found that careful pH control during work-up cuts the risk of residual halide, improving compatibility with basic and neutral downstream transformations. Grain size and morphology can also impact dosing in automated synthesis devices, so we mill to a consistent particle profile for production batches above 1 kilogram, avoiding wide size dispersity. These choices grew out of feedback loops—one major pharmaceutical partner flagged inconsistent slurry sedimentation during automated dispensing, pushing us to redesign our final drying and sieving steps.
Not every synthesis runs as anticipated. We see the pain points up close: a failed coupling after a week’s investment, a color streak in a purified sample, a workflow delayed because an intermediate refuses to dissolve at target loading. Early on, we watched several projects lose time to minor ring isomer contamination introduced during upstream halogenation. Low-level aromatic impurities, hard to detect by GC alone, surfaced as troublesome in later steps, especially with grant timelines ticking down. We countered this by adding full HPLC profiles for aromatic byproducts as internal release criteria, rather than relying on single-point spot tests.
Water content emerges as another operational detail—a slightly over-dried powder can prove challenging to dissolve, just as traces of moisture can trigger unwanted hydrolysis. Years of data show that targeting a slightly higher, but narrow, moisture specification balances stability with practical handling. Our specification sets a maximum allowed water content, with checks at multiple points. When a customer encountered trouble with a clumpy lot, we introduced low-vacuum post-packing drying routines and added more aggressive molecular sieve cycles.
We do not simply post specification sheets with confidence. Every off-normal performance report triggers escalation: the technical team checks physical appearance, re-runs fresh NMR and HPLC, and reaches out directly to downstream users. The average user may not see this process, but it stands behind the number printed on every certificate and is the base for long-term relationships with research clients who work with hundreds of analogs and intermediates.
Peer-to-peer feedback loops across industry and academia keep us sharpening what goes out the door. One synthetic group showed us how our early lots left tiny colored streaks in silica during chromatography. They sent comparative TLC plates, and we dissected the results together. It turned out a minor impurity, invisible to routine UV detection, was responsible. A review of upstream raw ingredients revealed the problem—a supplier had delivered bromobenzene containing unreported trace levels of dibrominated material. We updated every incoming inspection for halide content and now run additional chromatographic screens at the intake dock, instead of relying on batch paperwork.
Academic partners reminded us of subtle stereochemistry hazards. When working up racemates where no official specification existed, several groups alerted us to small but significant enantiomeric drift occurring after prolonged storage under suboptimal temperature. Through direct dialogue, we modified packing to use heat-sealed foil under cool storage, stopping the drift while keeping the workup manageable. These feedback sessions trickle down to internal SOPs and ensure our lab teams learn the “why” behind specification details, not just the “what.”
Instrument downtime posed a less obvious but equally real problem in scale-up campaigns. During a three-month period of heavier than usual throughput, our HPLC autosampler started showing delayed calibration drift, and a customer flagged a broader than expected retention peak. We traced the issue quickly, recalibrated, and replaced worn tubing. The production timeline remained on schedule, but the episode spurred a preventive maintenance review schedule. Every instrument now receives routine pre-run checks, and instrument logbooks record calibration standards as much as output. This eliminates hidden risk and safeguards the repeatability demanded by drug discovery groups who depend on our timelines.
Manufacturing any aryl acid with halogenation at scale forces a careful approach to hazardous materials. We source all starting reagents with full documentation and audit suppliers regularly for trace contaminants. This vigilance flows from instances where minor lapses—a single subpar drum of raw fluorobenzene—cost substantial rework and lost time. We negotiate directly with logistics partners, coordinate the timed arrival of temperature-sensitive precursors, and maintain full backup stocks.
Our policy holds finished goods in ready-to-ship intermediate storage under nitrogen, not just dry rooms, to minimize oxidative changes, even though regular shelf data shows strong resistance to degradation. By retaining samples from every lot shipped, and storing these in matched conditions, our quality group can immediately investigate if a complaint or deviation ever arises. This practice allows direct side-by-side testing for color, purity, and dissolution characteristics, and has helped us resolve issues quickly, earning a level of trust with project managers who rely on timely, documented resolutions.
Transport and delivery protocols match our in-house controls. Temperature excursions, real-time transit data, and tamper-evident seals provide assurance that intermediate quality never slips during shipping. Our customers cite confidence in opening a drum and seeing exactly what the analytical paperwork promises—a consistency that reflects care at each transfer point rather than luck or blind trust.
Feedback from regulatory and environmental auditors has guided our expansion strategies and operational investments. The adoption of closed-system halogenation cut our handling exposure and minimized environmental waste loads. Effluent streams are treated on site, measured for halide and organic contamination, and released only after matched with discharge permits—there’s no incentive to cut corners here, because missed compliance can risk more than just reputation; it endangers staff, neighbors, and downstream customers.
GMP-driven projects push us to maintain clear documentary trails—batch records from the weighing of the first gram to final lot sign-off—and our team participates in annual refresher training on GMP standards. Procurement avoids conflict minerals and verifies certificates from any upstream partner handling fluorinated intermediates to ensure that every batch of product conforms to both legal and ethical expectations. We invest in solvent recycling systems to curb impact and bring running costs down, passing on a degree of savings directly as stable, predictable pricing.
Customers pursuing sustainability in their own operations regularly inquire about waste minimization and byproduct treatment. Open discussion about our recycling metrics, waste stream analytics, and operational improvements demonstrates accountability and builds trust for long-term projects.
Designing, producing, and supporting a compound like 3-(4-Bromo-2-fluorophenyl)propanoic acid isn’t a matter of scaling recipes or pushing out paperwork. It’s a craft developed by engaging with real-world problems at the bench, learning from setbacks, and collaborating openly with the scientific teams using these building blocks in demanding environments. We have seen both the errors and breakthroughs: cascading project delays from a minor impurity, then leaps in yield from a small tweak in synthesis or packing. These lessons become the backbone of both routine production and support, ensuring that each lot delivers the best possible outcome for research or process-scale use, embedded with the reliability that only first-hand experience provides.
Ongoing investment in both people and process lays the foundation. Employees with direct experience in separating stubborn aromatic impurities, running overnight moisture assays, or picking up on odd melting ranges, contribute more than any checklist or automated analyzer. They spot trouble early, innovate solutions with practical know-how, and train the next generation with stories not found in a manual. As regulatory scrutiny rises and new research needs stretch the envelope of halogenated intermediates, this experience keeps us agile, responsive, and confident in what we ship.
3-(4-Bromo-2-fluorophenyl)propanoic acid stands out because of the choices made throughout its pathway—from synthesis planning, purification, and QC, through logistics and customer support. It may share a backbone with others in its chemical family, but performance and reliability spring from the details: hard-won lessons, customer conversations, and a commitment to working alongside scientific partners. Every lot rolling off our line reflects these principles, setting a standard for research-driven manufacturing that supports confident discovery and development.