|
HS Code |
442073 |
| Cas Number | 38734-90-4 |
| Molecular Formula | C4H4N2O2 |
| Molecular Weight | 112.09 g/mol |
| Iupac Name | 2-nitro-1H-pyrrole |
| Appearance | Yellow to orange solid |
| Melting Point | 85-89 °C |
| Solubility In Water | Slightly soluble |
| Smiles | C1=CN=C(C1)[N+](=O)[O-] |
| Inchi | InChI=1S/C4H4N2O2/c7-6(8)4-2-1-3-5-4/h1-3,5H |
| Pubchem Cid | 11238345 |
As an accredited 2-Nitro-1H-pyrrole factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Sigma Aldrich's 2-Nitro-1H-pyrrole (5g) is supplied in an amber glass bottle with a secure screw cap and detailed labeling. |
| Shipping | 2-Nitro-1H-pyrrole is shipped in tightly sealed containers, protected from light, heat, and moisture. The package is labeled according to hazardous material regulations (flammable, irritant). Shipment complies with DOT, IATA, and IMDG guidelines, using specialized packaging to prevent leaks or contamination. Documentation includes Safety Data Sheets and relevant hazard information. |
| Storage | Store 2-Nitro-1H-pyrrole in a tightly sealed container, in a cool, dry, and well-ventilated area, away from sources of ignition and incompatible materials such as strong oxidizers and reducing agents. Protect from light and moisture. Follow all safety protocols, including the use of appropriate personal protective equipment (PPE), and consult the Safety Data Sheet (SDS) for detailed handling and storage guidelines. |
Competitive 2-Nitro-1H-pyrrole prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
2-Nitro-1H-pyrrole has earned a distinct reputation in various chemical sectors, and as a manufacturer with hands-on experience synthesizing this compound, a few things stand out immediately. Every batch that leaves our facility carries the hallmarks of precise reaction control and careful raw material selection. Our technical teams spend a great deal of time fine-tuning each stage to prevent unwanted byproducts, and those who have ever run a pyrrole nitration themselves will recognize just how easy it is for process drift to compromise purity. We chose an integrated production route not because it’s the cheapest path, but because it gives us the lever to respond to small variations in input quality and reaction conditions. This level of control never feels optional when the end applications demand reliability.
We draw our understanding from the shop floor, not out of stock phrases. 2-Nitro-1H-pyrrole, molecular formula C4H4N2O2, finds use where trace-level impurities jeopardize reactivity or downstream safety. Some customers buy it as an intermediate in heterocyclic synthesis. Others turn to it for use in agrochemical development or pharmaceutical research pathways where side reactions matter. It’s a market familiar with compromises, and one that values batch-to-batch reproducibility over impressive-sounding theoretical yields. This has shaped every improvement we’ve made inside our reactors, and kept our production teams focused on outcomes over short-term savings.
We make our 2-Nitro-1H-pyrrole available in various grades, not as an empty marketing gesture but because the demands from R&D labs and applied syntheses are fundamentally different. The highest-grade material comes with extremely low levels of related nitro-pyrrole isomers and nearly zero residual moisture. Chemists who’ve worked with off-spec nitroheterocycles understand the headaches—reactivity loss, color shifts during storage, new impurity profiles in spectra. There’s always a trade-off between cost and unnecessary purity, but working with real customers, we learned that cutting corners on this front leads to more out-of-spec end product than ever reaches final application. So we keep a tight rein on water and secondary contaminants, especially for groups using our material as a pharmaceutical intermediate or where downstream reactions are unforgiving.
Our standard model targets a purity level above 98 percent by HPLC. Whenever a custom cutoff is needed—for example, higher purity requirements for catalyst-sensitive reactions—we refine the product accordingly. For customers blending at scale, such as producers of advanced materials, we maintain clear lab-to-floor traceability to ensure each lot matches stated values. Bulk packaging is an afterthought for many, but our equipment team spent more time than most would guess on designing vessels that avoid caking and help with clean decanting. This small engineering tweak cut rejection rates and simplified customer handling steps, lessons learned through years of troubleshooting.
Experience shows that attention to purity isn’t academic. Take a typical synthetic sequence—unreacted starting materials or unremoved acids can throw off the next coupling or cyclization. In our own test lab, small batches of 2-Nitro-1H-pyrrole contaminated with even 1 percent alternative nitro isomers led to unexpected polymerization in condensation reactions. Over time, rework expenses and scrapped runs easily dwarf any savings from cutting corners. This became especially clear during feedback sessions with returning customers: researchers from both universities and industry cited unexpected color formers, instability in storage, or unexplained exotherms as headache sources. Internal audits pointed these issues straight back to minor impurities.
Our quality control proceeds stepwise. Every incoming lot of pyrrole feedstock undergoes GC and moisture screening, helping us catch splitter drift before it creates downstream rework. During nitration and workup, in-line infrared and spot HPLC checks flag any excursions fast, letting technicians intervene directly, rather than waiting until the final assay. One upside to doing everything under one roof is catching lessons early; a single observation from the plant floor often translates quickly into procedural tweaks upstream.
Customers sometimes compare 2-Nitro-1H-pyrrole to more common nitroheterocycles, and the differences are real. Large-volume suppliers of generic nitro compounds usually chase throughput, not trace control. This pushes them to minimize residence time and invest little in byproduct removal. With 2-Nitro-1H-pyrrole, even tiny amounts of unwanted isomers like 3-nitropyrrole or 4-nitropyrrole change downstream reactivity, color, or volatility, especially under basic conditions. We’ve spent years adjusting our reaction sequence—selecting the right temperature, solvent ratios, and even the order in which reactants are added. Technicians on the floor know specific temperature ranges that encourage the cleanest cut. Each batch coming off our lines gets an individual HPLC scan, leaving no room for “average” product quality.
Handling characteristics differ as well. Our years of running larger lots revealed that small process tweaks—such as pre-chilling the pyrrole, dosing acid in a particular sequence, and controlling agitation—led to better product flow, less clumping, and improved shelf stability over weeks or months. These may sound like esoteric technicalities, but customers working at pilot scale value the difference between easy transfer and clogged hoppers. So, direct production experience reshaped our approach, and customer feedback continues to close the loop.
We don’t speculate about possible uses; we listen to application feedback. In pharmaceuticals, 2-Nitro-1H-pyrrole shows value as a building block for more complex heterocyclic pharmacophores. Not every batch is destined for a blockbuster, but the research teams behind screening campaigns appreciate materials that react predictably, produce cleaner side-streams, and store without surprise degradation. Some academic researchers shared tales of unpredictable background coloration from inferior nitro sources—problems solved the moment they switched to higher control lots.
In crop protection chemistry, the compound acts as an intermediate in nitro-heterocycle scaffolds. Limitations on impurity profiles here aren’t just about lab neatness—regulatory filings require traceability, and unexplained process drift quickly complicates registration. Practitioners who’ve worked through agricultural registration cycles will tell you that an uncontrolled impurity profile creates paperwork headaches and adds months to launch timelines.
For specialty material firms, small volume batches of 2-Nitro-1H-pyrrole serve as starting points in innovative electronic and photonic structures. Stability in storage under ambient conditions remains a top concern for these groups, and recurring supply line interruptions highlight the risks of buying from traders or casual repackagers. Our direct manufacturing background helps us speak technically about batch variations, not just cite certificates.
Having produced every kilogram in-house, we learned a few hard lessons about storage and shipment that few upstream vendors will share. The compound’s sensitivity to moisture translates into caking and even partial decomposition if stored in substandard environments. We responded by moving away from open-drum and basic poly bags years ago. All high-purity lots now go into lined, hermetic steel drums, optionally under inert gas—at customers’ request. Any batch slated for extended shipment is tested again before release, not just to check for label compliance but to confirm stability. This practical feedback came from a European customer with a months-long transit window, whose team flagged critical drift after prior suboptimal handling elsewhere.
Product labeling can seem unimportant until customs or port authorities detain a shipment. We invested time designing clear, tamper-evident label systems, based on those rare mishaps, so destination chemists can verify batch identity without guesswork. Our logistics crew has learned to batch shipments with specialized carriers and appropriate hazardous paperwork, easing clearance and arriving ready for benchwork.
From a technical stance, process chemists often ask about storage life or reactivity after partial drum withdrawals. Our in-house studies suggest that, when sealed again after withdrawal and kept inside a dry, shaded environment, both performance and color remain within spec for up to six months. Teams looking for best results remove material using clean tools and never leave a drum exposed longer than necessary. These simple habits extend the value of every delivered drum and prevent avoidable stress on downstream operations.
Industry-wide surveys highlight the cascade of costs triggered by rework and poor reproducibility. A client survey we conducted last year found that one out of four inquiries originated from end-users grappling with an unreliable laboratory-scale batch that scaled up poorly. Delays originated from small contaminant build-ups and inconsistent reactivity, often traceable to one-off or secondary-source supplies. Building our own feedback database helped us learn from these struggles, shaping production and documentation at every stage.
Our technical support team answers direct process questions and gets regular updates from the manufacturing side. We document not only final assay results but also traceable inputs, ensuring that any feedback from the user feeds directly back to operators and line supervisors. We adapted our tracking systems to quickly identify trends—such as seasonal variations in feedstock purity or process drift during temperature spikes—helping control more variables before packing and dispatch. This level of transparency stems from operating our own reactors, not from trying to optimize margin per order through outsourcing.
We see ourselves not only as a supplier but as a participant in the application’s value chain. Years of real-world production experience highlight that process chemists care little for buzzwords and demand straightforward access to reliability data. They ask for root-cause analysis when an outlier lot emerges, and they share insight on new synthetic targets that stretch conventional impurity cutoffs. This gave us unique insight into balancing production speed with analytical depth, keeping our focus on what matters to actual users.
After a public supply chain disruption five years ago, we changed suppliers for our primary nitration agent rather than risk continuity. Each substitution involved small-scale pilot runs, GC-MS confirmation, and feedback from core partners who could assess downstream variability. Lessons like this explain our stance on direct manufacturing—secondary sourcing may work for bulk commodity chemicals, but compounds like 2-Nitro-1H-pyrrole require more oversight to meet evolving needs. The investment in vertical integration allowed us to keep our finger on every process lever, even if it meant smaller batches or slower line speeds when quality dictated caution.
Handling suggestions and documentation were updated after new storage studies revealed sensitivity to UV and certain plastics. We redesigned packaging and sent technical bulletins to repeat customers, receiving confirmation in the form of fewer incident reports and greater stability on arrival. Years later, these improvements seem obvious, but the learning curve involved enough day-to-day troubleshooting to shortcut surprises for any new client.
Hearing regularly from customers who struggle with reproducibility shaped our view. They remind us, with every inquiry and repeat order, that upstream diligence translates into less drama at the bench. A batch arriving out-of-spec isn’t just a logistics hassle—it often halts critical project steps, delays entire campaign schedules, and adds costs everyone could use elsewhere. After witnessing the downstream effect of even tiny impurity shifts, our entire team doubled down on both batch-level documentation and root-cause investigation, closing the feedback loop between production and application use.
Clients pursuing scale-up or regulatory clearance know firsthand how a single contaminant escapes easy removal in final APIs or formulated materials. We addressed this by building a feedback culture, where production, QA, and technical support teams meet regularly to share the latest customer observations. Real-world problems, not just academic standards, fuel our improvements and process modifications.
If you want a sense of whether a 2-Nitro-1H-pyrrole source understands more than re-packaging and brokerage, listen to what they say about process drift, impurity control, and real-world application feedback. Years of manufacturing have shown us the practical and sometimes invisible differences between a sample that “looks pure” on a piece of paper, and batches that pull their weight in the lab. There’s no way to shortcut hands-on quality assurance, and no substitute for experienced troubleshooting when plans change or shipments get delayed.
We don’t claim perfection, but our focus remains on proven reliability. Our production teams, QA crews, and technical support staff work together, fueled by real feedback, not guesswork. Our 2-Nitro-1H-pyrrole meets tough standards—because our customers asked for it, and because we see first-hand what happens when others don’t.