HS Code |
492652 |
| Name | 1-Fluoro-4-iodo-2-methoxybenzene |
| Cas Number | 213150-21-9 |
| Molecular Formula | C7H6FIO |
| Molecular Weight | 252.03 g/mol |
| Appearance | Pale yellow to light brown solid |
| Melting Point | 34-37 °C |
| Boiling Point | 268-270 °C |
| Density | 1.87 g/cm³ (estimated) |
| Smiles | COC1=CC=C(I)C=C1F |
| Inchi | InChI=1S/C7H6FIO/c1-10-7-3-2-5(9)4-6(7)8 |
| Purity | Typically >97% |
| Synonyms | 2-Methoxy-1-fluoro-4-iodobenzene |
| Solubility | Soluble in organic solvents such as DMSO and chloroform |
| Refractive Index | 1.621 (estimated) |
| Storage Conditions | Store at 2-8°C |
As an accredited 1-Fluoro-4-iodo-2-methoxybenzene factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 1-Fluoro-4-iodo-2-methoxybenzene is typically supplied in a 1g amber glass bottle with a secure screw cap and hazard labeling. |
| Shipping | 1-Fluoro-4-iodo-2-methoxybenzene (chemical grade, Sigma Aldrich/Merck/TCI) is shipped in tightly sealed containers, protected from light and moisture, and packaged according to hazardous material regulations. Shipping complies with international transport guidelines and may require labeling for flammable or toxic substances. Expedite delivery ensures product integrity and safety during transit. |
| Storage | 1-Fluoro-4-iodo-2-methoxybenzene should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area, away from heat, ignition sources, and incompatible substances such as strong oxidizers. Protect the chemical from moisture and direct sunlight. Store in an appropriate chemical storage cabinet and clearly label the container. Follow all relevant safety guidelines and local regulations. |
Competitive 1-Fluoro-4-iodo-2-methoxybenzene prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
At our plant, we synthesize 1-Fluoro-4-iodo-2-methoxybenzene with an eye for consistent quality and traceable origins. This compound – known by many chemists for its CAS number 57392-11-7 – brings together a benzene ring where methoxy, fluoro, and iodo groups play off one another. From our own hands-on work with the molecule, the combination is not just about adding three groups, but about unlocking a set of reactivity patterns that many simpler halobenzenes lack. Customers looking for high-purity material should know our process was tuned after hundreds of kettle runs, with each batch checked for low moisture, minimal byproducts, and tightly managed impurities. Gone are side-reactions that plagued early syntheses – years ago, we learned how to steer clear of hydro-dehalogenation and nonselective O-demethylations through precise temperatures, atmosphere control, and the right molar ratios.
It’s not just the chemistry that draws attention – it’s also how this material moves from reactor to your shelf. Across multiple scaling campaigns, we’ve tracked how 1-Fluoro-4-iodo-2-methoxybenzene behaves under storage and shipping. Cardboard leaches moisture if left unchecked, so we always pack under nitrogen, then seal in amber glass within foil-lined drums. We once tested untreated PE drums and found the fluorinated ring kept stable, but traces of iodo fragmentation showed in samples exposed to UV. Our packaging crew switched to light-sensible storage for good reason.
On the bench, the pale crystalline powder pours with minimal static. At plant scale, we tune particle size through filtration and recrystallization. Customers working in pharma research mentioned how a fine, free-flowing powder quickens internal processing, reduces prep time, and cooperates better with automation in high-throughput settings. For kilogram runs, we send sieved material with careful particle size checks – no dome-like cakes that slow reactor charging, no fines that gum valves. Sometimes, chemical supply is about labor too.
In our years supplying this molecule, its reputation as a useful intermediate in the synthesis of pharmaceuticals, agrochemicals, and functional organic compounds is well-earned. The electron-withdrawing fluoro and iodo positions tune the benzene ring reactivity for cross-coupling, making it a regular in Suzuki-Miyaura, Stille, and Sonogashira reactions. We see medicinal chemists asking for it by name for late-stage diversification on drug candidates. The ortho-methoxy adds another layer, changing how catalysts and nucleophiles access the ring. Some ask why not use 4-iodo-2-methoxyaniline or related analogues – from our runs, those lack the specific balance of activation and selectivity in arylations and metal-catalyzed substitutions that comes with a fluorine in the para-location.
A well-behaved substrate means easy downstream purification – our colleagues in scale-up chemistry point out how the specific substitution removes tedium from column chromatography or crystallization. In our analytics lab, we’ve compared impurity profiles of various halogenated anisoles. The 1-fluoro, 4-iodo, 2-methoxy arrangement allows more predictable side product formation. For those churning out combinatorial libraries, this means speed and less waste.
Compared to other halogenated anisoles, this compound distinguishes itself by practical reactivity, not just theory. During one campaign, an agrochemical group contacted us after running into low yields and excessive dehalogenation with a 4-chloro-2-methoxyanisole in their coupling sequence. With 1-fluoro-4-iodo-2-methoxybenzene, the fluorine offers strong ring activation while the iodine offers reactivity in palladium-mediated reactions. Our QC team has documented repeatedly: less decomposition, fewer off-path reactions, and higher crude yield in side-by-side tests.
In the past, resins reacted unpredictably with more conventional iodoanisoles, sometimes leaving color bodies in the mother liquor. Here, the fluorine’s effect can reduce tar formation, making purification less arduous. Many customers say this product cuts hours off their work-up time, which our plant’s technical staff can confirm from our own process cleanouts. Lower tar equals faster cleaning, more uptime, fewer solvent cycles.
We’ve run our synthesis route for over a decade. Some competitors cut corners with insufficiently pure starting materials or rely too heavily on harsh reagents that raise the impurity profile of the finished compound. By using high-grade fluoroanisole precursors and iodine sources, and dialing in reaction times based on kinetic profiling, we maintain a standard others struggle to match. Longevity in this business comes from listening to feedback. Graduate students and production chemists both care about problems like haze formation, handling ease, and batch-to-batch reproducibility – the nitty-gritty that separates a working supply from just a label on a drum.
Passionate as we are about chemical synthesis, we know from hard experience that a little extra attention during production and purification pays dividends downstream. We keep impurities low on repetitive halogenation by scrubbing all glassware, using dry solvents, and flushing systems to avoid cross-contamination – not theory, but lessons learned the long way. Each batch faces scrutiny through NMR, GC-MS, and HPLC before passing on. Minor differences slip through when process controls fail, so we calibrate our instruments frequently and run regular proficiency tests.
Years ago, we encountered a critical feedback after a client’s cross-coupling failed due to a trace of unidentified impurity. Our team traced the issue back to an inadequately dried sodium iodide. Since then, our QA practices include frequent lot checks and in-process monitoring, slashing lot-to-lot deviations. It’s not just about ticking off regulatory boxes – it means less frustration in the lab and more reliable reaction outcomes for every unit that leaves our site.
Labs and plants working on small molecules for clinical applications often look for chemical building blocks with unique substitution patterns to explore structure-activity relationships, or to fine-tune physical properties in their compounds. We’ve partnered with innovation teams who need scalable access to halogenated anisoles. Scale rarely unfolds as expected – as reactions climb from grams to kilograms, new hurdles pop up. We support process development chemists who want guidance on the quirks of 1-fluoro-4-iodo-2-methoxybenzene: moisture tolerance, sensitivity to strong nucleophiles, residue management after couplings, or optimum solvent choices.
Some groups use this compound as an intermediate in the preparation of complex biphenyl ethers through palladium-catalyzed coupling. We’ve seen firsthand their need for reproducibility and clarity in each lot; minor differences in color, moisture, or impurity type can derail weeks of effort. On a number of occasions, we’ve hosted visits from production teams to evaluate our plant and quality systems. These walk-throughs build trust – the chemists see who makes the compound, the controls we place, the reasons we reject batches showing even minor off-spec bands. We invite technical dialogue with our customers rather than relying just on a COA.
Our day-to-day includes more than batch chemistry. We troubleshoot real process issues: frothing during addition steps, needle-like crystals that plug filters, sensitivity to trace acid or base. These are obstacles you don’t read about in the literature, but any production chemist recognizes instantly. Over time, we’ve refined approaches – changing agitation speeds, switching out anti-static liners, adopting glovebox charging for sensitive operations.
We monitor reaction endpoints through online analytics where possible. One memorable campaign, rising viscosity nearly shut down transfer lines – fine-tuning solvent ratios kept product moving. Years of experience teach that no synthesis stays “by the book” for long. By logging everything from failed runs to process parameter shifts, we’ve kept our customers supplied through ups and downs. That knowledge doesn’t come from abstract SOPs, but from technicians and chemists meeting around the kettle at the start of every shift.
Working with halogenated aromatics means keeping safety and environmental goals at the forefront. Our facility captures waste streams and recycles solvents where possible. Air-handling keeps dust and fumes contained, and regular emissions testing confirms compliance. We’ve shifted many steps to closed systems, minimizing operator exposure. Production workers receive regular training, and the plant runs safety and near-miss reporting. The difference is in the follow-through. Routine may not make headlines, but process safety feedback and close-out reports protect everyone on site and downstream.
From our side, we respond to evolving regulatory conditions by maintaining documentation and trace evidence for every lot. Customers rely on knowing the supply and waste chain behind their starting materials, especially those submitting IND applications or regulatory dossiers. Our team keeps batch records auditable for many years – direct conversations with regulatory colleagues helped us design our recordkeeping and reporting to their satisfaction.
Feedback from chemists, engineers, and safety personnel shapes our next batch and our next investment. For one, adjustments to purification protocols followed detailed feedback on downstream interactions with coupling partners. In other cases, requests for more granular moisture testing improved our analytical workflow. Process tweaks often arise from production floor conversations or an urgent call from a research lab running into trouble at scale-up. As a manufacturer, the way forward runs through direct dialogue, transparency, and a willingness to refine old methods.
Our collaboration with labs and production sites helps us design better packages and logistics. Special requests for anti-static drums, extra sieving, or solvent-wetted product (to prevent dusting) get routed into our upcoming runs. Regular inventory and supply assessments allow us to meet deadlines and avoid disruption. Each season brings new challenges: macroeconomic swings, raw material shortages, shifts in regulatory focus. By staying close to both suppliers and end-users, we adjust faster and deliver with fewer surprises.
Several factors set 1-fluoro-4-iodo-2-methoxybenzene apart from alternative halogenated aromatics. The electronically tuned substitution pattern impacts both the selectivity and yield of critical reactions. We have tested similar molecules in Suzuki couplings and consistently observed more stable reaction courses, less side product formation, and simpler purification schemes when using our compound. Process engineers in major pharmaceutical plants told us how switching to this material reduced batch rejects caused by incomplete coupling or excessive color bodies.
Some other halogenated anisoles work well on paper, but fall down at the bench due to unpredictable behavior in real-world process conditions. We’ve tracked batch data from numerous campaigns and have found reduced system downtime, easier workup, and fewer filter clogs with our process controls dialed in for this compound. Routine feedback from customer sites flags this as a standout benefit – not from marketing data, but from direct conversations after successful scale-ups.
Experience also shows how minor tweaks in substitution have an outsize effect on end product chemical and physical properties. In fields like OLEDs or specialty dyes, this compound lends itself to applications requiring consistent electron density and steric effects. The dual halogenation allows for selective functionalization, supporting a broader palette of downstream syntheses than simpler mono-halogenated aromatics. Having supplied materials for over a decade, we track not just lab-scale stories, but multi-ton campaigns that anchor advanced material development.
As the manufacturer for 1-fluoro-4-iodo-2-methoxybenzene, our perspective is shaped by thousands of batches, close work with our technical staff, and honest conversations with researchers around the world. We continuously adapt to the evolving landscape of synthetic organic chemistry, and we know each drum or bottle of our material carries not just chemical content, but the hard-won experience of everyone who contributed to its creation. This is not a commodity to us; it is a synthesis, a process, and a commitment to quality recognized by chemists and engineers alike. By keeping fit-for-purpose synthesis at the center, and responding directly to real-world needs, we support innovations that start small but grow large – just like every process in the chemical world.