West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Phenylfluorone

    • Product Name Phenylfluorone
    • Alias 4,5-Dibromo-2-(3-hydroxyphenylazo)phenol
    • Einecs 249-096-6
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    181071

    Name Phenylfluorone
    Cas Number 17794-74-0
    Molecular Formula C20H12O3
    Molar Mass 300.31 g/mol
    Appearance Yellow powder
    Solubility Slightly soluble in water, soluble in organic solvents
    Melting Point Approx. 240-242°C
    Absorption Maximum 410 nm (in ethanol)
    Applications Colorimetric reagent for metal ions
    Synonyms 4-(2-Phenyl)-3H-xanthen-3-one
    Storage Conditions Store at room temperature, protect from light

    As an accredited Phenylfluorone factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Phenylfluorone (Sigma-Aldrich, 1 gram) is supplied in an amber glass bottle with a tightly sealed cap, labeled with product information.
    Shipping Phenylfluorone is shipped in secure, chemical-resistant packaging, compliant with relevant regulations. It is classified as a laboratory reagent and may require a Materials Safety Data Sheet (MSDS). Shipping is typically via ground or air transport, following restrictions for hazardous materials, with temperature and handling precautions as specified by suppliers like Sigma Aldrich, Merck, or TCI.
    Storage Phenylfluorone should be stored in a tightly sealed container, protected from light and moisture. Keep it at room temperature (15-25°C) in a well-ventilated, dry area away from incompatible substances such as strong oxidizers. Use appropriate chemical storage cabinets, and label containers clearly. Ensure it is only accessible to trained personnel following standard laboratory safety protocols.
    Free Quote

    Competitive Phenylfluorone prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Phenylfluorone: Our Experience with a Unique Analytical Reagent

    In our production environment, phenylfluorone keeps making its mark as a key chemical for laboratories dealing with ultra-sensitive detection needs. We manufacture it under strict conditions, drawing on years of handling dye-based indicators. The structure of phenylfluorone, C20H12O3, with its characteristic conjugated aromatic system, gives it a vivid color-shifting profile that sets it apart from generic indicators. Most people recognize it as a colorimetric reagent for trace metal determination, particularly for bismuth, but behind the scenes, our attention to process details plays a bigger role in getting consistent results for analytical specialists.

    Physical and Chemical Profile — What Sets Our Phenylfluorone Apart

    Each lot of our phenylfluorone presents as a deep red crystalline solid, free-flowing and moisture-protected straight from the drum. On the bench, it dissolves cleanly in standard solvents like ethanol or acetone with little residue, supporting its use in routine and high-sensitivity spectrophotometric assays. The solid resists caking and compaction thanks to close control over crystal growth stages—a practical point that cuts down prep time for analysts. Many in Q.C. labs value this handling difference when turnaround and precision matter together.

    Our batches fall within the expected melting range of 257 to 260°C, and purity routinely logs above 98% by HPLC. This high level of chemical clarity ensures tight, stable responses in metal ion assays. Alternative dyes often show more baseline drift and need more blank runs. Phenylfluorone handled right will show sharp chromogenic transitions, especially in bismuth, lead, and thallium detection, giving confidence on both daily checks and method development projects.

    Key Application: Trace Metal Analysis That Demands Accuracy

    Teams relying on phenylfluorone usually specialize in detecting ultra-low concentrations of metals. In these jobs, everything depends on the reagent’s batch-to-batch consistency. Spectrophotometric methods with phenylfluorone can pick out bismuth down to a few parts per billion. The color reaction forms a stable, intense complex, yielding clear signals even against noisy backgrounds. Our manufacturing focus aims to give researchers tools that respond identically every time, eliminating second-guessing variable purity or hidden contaminants.

    In environmental labs, water quality experts look for minute traces of heavy metals. They demand reagents that won’t add extraneous signal or mask subtle changes. Our phenylfluorone, when dissolved fresh, avoids false positives from metal impurities—an issue more common with uncontrolled or vendor-blended alternatives. For pharmaceutical checks or certified reference work, even small deviation in spectral profile can cause headaches during audits or round-robin studies. We test each batch for interfering ion content and lock down storage conditions to block hydrolytic breakdown or dye oxidation on the shelf.

    Our Experience with Production and User Feedback

    Through years of production, we’ve seen just how sensitive this product is to changes in synthesis protocol. Variables like catalyst loading, solvent selection, and temperature ramp can make or break the batch. A poorly cleaned reactor or slip in vacuum drying will trigger color impurities that shift analytical baselines—issues that downstream users spot fast. We keep a tight grip from raw material sourcing to post-packing handling, using controlled humidity rooms to avoid moisture pickup that might lead to slow degradation. End users frequently cite the clean dissolution and absence of fine dust as reasons for sticking with our batches. They mention fewer outliers on their calibration curves and more predictable standard recoveries on validation runs, which ultimately means less rework and more credible data.

    One user, a water analysis specialist, pointed out that competitive products often carry enough trace copper or iron to throw off blank readings. By testing our raw phenylfluorone for transition metal traces, we give these labs an extra level of trust in their results. We publish impurity profiles for most lots so labs know precisely what’s in their reagents. As a result, researchers spend less time troubleshooting and more time developing data-driven solutions to real world issues—like early-warning systems in municipal water supply monitoring.

    Comparison with Other Indicators

    Many labs view phenylfluorone as a go-to for bismuth due to its sharp complexation and color response. Compared to dyes like dithizone or PAN, phenylfluorone’s primary strength lies in its selectivity and sensitivity at low concentration. Some competitors substitute with universal or broad-spectrum dyes that may react with a wide set of cations, but they can’t achieve the signal/noise clarity needed for tight-range detections. Phenylfluorone impresses with its linear response and steep calibration curve, which is critical when distinguishing small differences between samples. The complex with bismuth appears at a distinct wavelength, reducing overlap with other background signals, which is less true for other dyes weighing down multi-metal scans with overlapping spectra.

    On the laboratory bench, phenylfluorone solutions retain stability longer than conventional dyes under ambient conditions, limiting reagent prep waste and allowing longer continuous runs. We see fewer complaints about precipitation or slow color fade compared to PAN or xylenol orange. This longer shelf- and working-life means labs run more samples per bottle, keeping both waste and cost in check. For critical method validation, this makes a practical difference, particularly in regulatory environments where standards are tight and repeat analysis is both expensive and time-consuming.

    Specifications from Experience, Not Just the Literature

    After years in production, the difference between phenylfluorone and off-the-shelf indicators starts with how trace metal content is monitored. We use high-purity solvents and close filters during isolation, capturing fine particulates before drying. Each batch logs a trace analysis panel that covers relevant metallic species, phosphorus, and water content. Typical moisture content falls below 0.05% due to controlled atmosphere handling. The crystal form remains largely consistent, thanks to tuning the last solvent system and keeping the recrystallization temperature in check. This attention to form matters for rapid dissolution and long-term batch homogeneity, two points that regulars in QC appreciate after years of frustration with sticky or hard-packed alternatives.

    We watch for subtle changes in hue or odor during bulk packing, which signal the possible onset of polymorphic shift or trace decomposition. Experience has shown that ignoring these minor cues leads to early complaints from customers, so ongoing batch-by-batch visual checks supplement instrumental analysis. Our workforce knows that test tube performance hinges on these routine observations. This hands-on approach yields more reliable performance than what we see from more automated or remote-controlled operations on the market.

    Real-World Usage and Measurement Practice

    In the field, phenylfluorone gets most use in spectrophotometric determination of bismuth and similar metals at very low detection limits. The usual protocol involves forming a colored complex in slightly acidic or neutral solution, then measuring absorbance at a specific visible wavelength. Copper interference, a known headache, drops sharply due to the specific structure of the dye-metal complex. Users working in municipal water labs or geological mineral assays come back for repeat orders, pointing to low noise on sample runs and short clean-up times for glassware and cuvettes. This translates practically into easier record-keeping, less time re-running questionable results, and less solvent usage during apparatus washing.

    Academic researchers often use phenylfluorone for method development or to validate new processes in trace analytical chemistry coursework. Some run it for teaching classic colorimetric analysis, while others set up calibration standards for proficiency testing. In these schools and research centers, the pure, bright solution forms serve as good visual demonstrations of the classical coordination chemistry that underpins its performance. Because of our strict cleaning and production conditions, teachers and students report fewer problems with solution haze, which otherwise leads to poor example runs and lost lesson efficiency.

    Storage, Handling, and Stability from the Factory Floor

    From a manufacturing standpoint, phenylfluorone needs cool, dry storage with a tight seal on containers to block humidity and airborne contaminants. Once exposed to unfiltered lab air, ambient moisture can lead to clumping, slight color shift, or slower dissolution—effects that downstream labs recognize and associate with inconsistent quality. We package product in lined drums or amber bottles, based on user volume, and run random stability sample pulls from our finished goods warehouse to check for slow loss of activity over time. Each stability check focuses on color, moisture, and trace impurity buildup, not just nominal shelf life. These in-house controls enable us to answer user questions with facts, not generalized advice. If users ever need tips to extend open-bottle life, our support team can share details from the same checks we run in daily production, giving honest recommendations rooted in our process history.

    Why Purity and Traceability Matter to End Users

    Today’s analyte detection demands precision above all else. Metal ion trace analysis challenges standard operating windows, where every source of variability—moisture, contamination, oxidation—erodes trust in the result. We have seen how seemingly minor lapses in traceability turn into major issues for users testing drinking water or pharmaceutical grades. By keeping clear records from synthesis through QC testing, we back up every lot of phenylfluorone with transparent purity profiles and retention samples. Our customers regularly praise the detailed documentation accompanying each shipment. Auditors and regulatory agencies ask for it more frequently now, and labs need fast answers about possible cross-contamination or batch history. Our experience shows that open books and strict tracking support science-driven, reliable decisions—instead of relying on catalog specifications or hope that product “should be good enough.”

    Supporting Consistency: A Feedback-Driven Manufacturing Approach

    Feedback from front-line users—and the problems they face—shapes our day-to-day operations. For example, years ago, recurring feedback from spectroscopic labs pointed to tiny but consistent drift in absorbance baselines between lots. We responded by tightening speed and endpoint controls during synthesis and ramping up raw material screening, trimming contaminant profiles to well below typical supplier grades. By building these end-user insights into our standard practices, we save everyone cycles of troubleshooting and foster real collaboration between manufacturing and analytical communities. Users who rely on tight reporting standards value this ongoing improvement, because it means fewer disruptions and more predictable performance, week after week.

    We don’t see phenylfluorone only as a commodity chemical—its significance lies in the role it plays as a foundation for high-trust analytical work. Teams that handle compliance-driven QC, or who must validate every minor sample deviation, recognize that the quality of this one reagent can affect an entire reporting season. For this reason, we track not only analytical metrics, but also practical feedback: shelf-life, glassware cleaning times, and mix stability under everyday laboratory conditions. Our philosophy stays rooted in listening first, then adjusting process parameters with the same care that users apply to their method validation and equipment calibration.

    Looking Toward the Future in Analytical Chemistry

    Demand keeps shifting for more selective, targeted, and stable reagents in trace analysis. Whether the driver is emerging contaminants, increasingly strict regulation, or just higher throughput targets, labs will face new limits in the years ahead. We see this reflected in the requests for tighter impurity controls and lot-level certificates that not only confirm purity, but explain what steps we’ve taken to remove possible interfering substances. Phenylfluorone’s value in this space depends on a close partnership between chemical makers and analytical users, tightening both production specs and record-keeping in step with laboratory progress.

    We prepare for these challenges with ongoing upgrades to filtration, drying, and packaging—choosing practical improvements that reduce downtime, boost throughput, and simplify downstream handling for labs of all sizes. At the same time, staff development in our plant centers on building experience around the unique needs of indicator-grade products, so quality does not slip into complacency. The expectation for faster, more reproducible results grows every year, and tools like phenylfluorone are core to meeting these rising standards. As manufacturers, our role is to stay ahead by combining technical rigor with plain communication and by supporting customers not only with products, but also with the shared experience that gets results in the real world.