|
HS Code |
613527 |
| Name | Gallein |
| Chemical Formula | C19H12O7 |
| Molecular Weight | 352.3 g/mol |
| Cas Number | 2107-16-4 |
| Appearance | Red to dark purple powder |
| Melting Point | 360 °C (decomposes) |
| Solubility In Water | Slightly soluble |
| Storage Conditions | Store at room temperature, keep container tightly closed |
| 用途 | pH indicator, analytical reagent |
| Synonyms | 3,3-Bis(4-hydroxy-2-carboxyphenyl)phthalide |
| Ec Number | 218-304-7 |
| Pubchem Cid | 6813 |
As an accredited Gallein factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Gallein (Sigma Aldrich) is packaged in a 25g amber glass bottle with a white screw cap and clear product labeling. |
| Shipping | Gallein (chemical grade) from Sigma Aldrich, Merck, or TCI is shipped in tightly sealed containers to prevent moisture and light exposure. The product is typically packed in amber bottles or appropriate packaging and dispatched as non-hazardous material under standard shipping conditions. Always follow manufacturer and regulatory guidelines for safe handling and storage. |
| Storage | Gallein (Sigma Aldrich/Merck/TCI Chemical Grade) should be stored in a tightly closed container, in a cool, dry, and well-ventilated area away from incompatible substances such as strong oxidizers. Protect from light and moisture. Store at room temperature (15–25°C) unless otherwise specified by the manufacturer. Always follow the specific storage recommendations provided on the product's Safety Data Sheet (SDS). |
Competitive Gallein prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Over decades spent in chemical production, certain specialty reagents pass the test of time by earning loyal users in academia, industrial laboratories, and manufacturing lines. Gallein (C19H12O7), a synthetic organic compound developed in the 19th century, anchors itself in this group. From the factory floor to the end user’s bench, Gallein’s value does not rest on tradition alone. Its unique structure, distinctive color properties, and reliable performance have made it the preferred indicator and reagent for generations of chemists and technologists who prize reliability above marketing spin.
Gallein carries the chemical designation 3,4,5,6-tetrahydroxyxanthen-9-one-2-carboxylic acid diphenyl ether. Our production yields Gallein as a fine, dark brown to reddish powder. Purity always presents a challenge with organic indicators, so our focus prefers minimizing impurities such as dibrominated by-products and unreacted precursors, since even minor contamination can alter its coloration performance in trace analysis. The batch process involves careful temperature control and a hands-on approach at this size scale, where filtration stages and repeated crystallizations help maintain consistency.
Moisture content, solubility in water, alcohol, and alkaline solutions all matter to users, especially those developing or troubleshooting analytical methods. Gallein remains barely soluble in cold water, but dissolves better in hot water and ethanol. This matters in sample preparation and gradient solutions. In its solid state, it remains stable for extended storage when sealed from moisture and light — a direct result of careful drying and packaging steps on our end. Our packaging team thoroughly inspects lots for caking or discoloration, so customers work with fresh material.
Unlike many synthetic dyes, Gallein owes its practical appeal to a clear and sharp color change, especially in alkaline conditions. In neutral solutions, it appears pale yellow or brownish, while the addition of alkali brings about a violet-red hue, making endpoint detection unmistakable. The color persists and resists fading during routine titrations, saving both time and uncertainty for technicians. The depth and brightness of this color result from the particular arrangement of its phenolic groups—an arrangement demanding precision in synthesis and purification. During manufacture, strict process monitoring determines the final product, as incomplete reactions or side products can dull the color or shift it out of range, leading to inconsistent readings in titrations or indicator papers.
Our clients use Gallein most frequently as a colorimetric indicator in complexometric titrations, especially for understanding magnesium and calcium concentrations. That specificity often makes it the reagent of choice during magnesium analysis over more generic indicators. The clear endpoint—marked by a vibrant magenta or red color—shows up reliably and unmistakably compared to fainter results with other indicators. In the context of water quality testing and boiler feed management, technicians often combine Gallein with other indicators to tune their test’s sensitivity for magnesium, as calcium frequently dominates the samples.
Experienced operators in plating and metal finishing rely on Gallein to monitor bath chemistry. Small margin errors during the maintenance of magnesium levels can lead to rejected parts and wasted material. Because Gallein holds up under harsh bath conditions and continues to give a clear visual cue, metal finishers use it to ensure both product quality and process efficiency. In this context, shelf life and reagent stability rise to the forefront, since labs want a product that always performs, unopened or used over several months.
The compound’s adoption in advanced analytical chemistry extends far beyond routine titrations. Researchers exploit its sensitivity to magnesium for developing sensitive detection kits for trace analysis in biological samples and semiconductor effluents. Our manufacturing team supports several custom requests for higher-purity or pre-dosed Gallein—responding to research groups investigating trace metals in sensitive materials, where reagent consistency and lack of background interference matter as much as reagent cost. As detection methods push into the sub-ppm range, every variable counts, and researchers often come to us to discuss further purification or precise packaging, shaping our production standards.
In the last several years, the growing need to control heavy metal contaminants in wastewater has driven more water treatment facilities to adopt Gallein-based tests. Many regulatory bodies or industrial buyers see non-toxic indicator chemistry as essential, and the industry’s move away from certain heavy-metal-based dyes has cemented Gallein’s appeal. Traditional indicators might interfere with downstream analysis, especially in environmentally sensitive applications, and facilities face penalties for off-spec effluent. Our customer support works directly with quality-control managers on optimizing methods that leverage Gallein’s strengths, reducing process downtimes linked to ambiguous test results.
Unlike Eriochrome Black T or Calmagite, Gallein stands out through both its selectivity and color intensity in magnesium determination. In practical experience, operators using Eriochrome Black T report less vivid endpoint colors and occasional interference from other cations. Gallein’s sharper red-violet shift at the magnesium endpoint reduces subjective error in manual titration—something that matters in industrial labs where speed and accuracy both count. In environments with complex water chemistry, Gallein’s greater chemical resistance prevents indicator breakdown, where others might fade or change color even before addition of analyte.
Selecting an indicator boils down to trade-offs between price, availability, performance, and environmental footprint. On the factory line, many customers switch from multi-use indicators to Gallein for dedicated magnesium monitoring, sometimes offsetting the marginally higher material cost with the savings produced from fewer failed batches and less rework. Our feedback from long-term partners shows that staff training becomes easier, too—the unmistakable endpoint color eliminates the need for additional cross-checks or verification steps, helping streamline high-volume workflows.
Chemical manufacturing often juggles between volume economies and small-batch specialty production. Gallein lands in the latter category—even as a century-old material, its users keep a close eye on batch-to-batch quality. We maintain a nimble production line, with all raw material lots certified for purity by in-house gas and liquid chromatography before synthesis. Each lot receives its own colorimetric profile using standard magnesium solutions. Seasonal humidity and temperature swings get accounted for during drying and filtration, minimizing the risk of clumping or off-color lots that could cause headaches for end users. Chemical process control is not automated to the last step—experienced technicians inspect both the intermediate and finished product, a practice validated over decades of complaints-free supply to universities and industry.
Large-scale producers might outsource QA or batch certifications. We keep this in-house to address customer questions before lots ship out. Our technical staff, who interact with users in the lab or on plant visits, provide valuable feedback straight to production. We adapt or fine-tune synthesis based on recurring requirements, such as extended shelf-life and dust-free flow properties. In an industry where “good enough” often gets by, our business depends on never resting at “good enough.”
Ensuring that Gallein reaches customers in optimal condition calls for robust packaging and controlled logistics. Every lot gets packed in moisture-barrier containers, with tamper-evident seals and clear labeling. We advise storing Gallein away from bright light and high humidity, as these accelerate degradation over months. Small flakes or a fine powder form allow for precise dosing and speedy solution preparation, serving both bench chemists and production-scale users. Our process includes random sampling of each finished lot for accelerated aging, confirming stability under real-world shipping and handling routines.
Seasoned buyers in Asia, Europe, and North America each report different climate challenges, impacting end-user experience. We ship in insulated containers during peak summer to avoid caking or melting. End users notice the difference, as freshly delivered Gallein performs consistently—clear bright endpoints, minimal clumping, and expected flow properties. Feedback from recurring customers confirms this attention pays off in everyday operation, keeping test results accurate and predictable.
Recent disruptions in global shipping and raw material costs highlight the fragility of specialty chemical supply chains. We’ve faced periods where precursor shortages threatened production, especially with transport bottlenecks or new customs inspections. Maintaining multiple sources for precursor chemicals and keeping a safety stock reserves help us keep supplies regular in a world fond of supply shocks. Direct communication with our clients prevents confusion if a delay is unavoidable, but our on-hand stock often carries orders through hurdles that knock out less-prepared suppliers.
Regulatory and compliance trends shape the future of chemical indicators. The shift away from substances with suspected environmental or health hazards, especially in Europe and North America, favors Gallein’s continued acceptance. We actively review our process for by-product minimization, as emerging trace contaminant standards could disqualify otherwise proven indicators. Customers increasingly ask for documentation on heavy-metal content, and our laboratory provides verified certificates for critical applications. This open-book approach reduces client and auditor friction—a simple way we translate compliance into customer satisfaction.
Gallein may be a classic indicator, but each year brings new demands as research and industry develop fresh applications. The rising need for rapid, field-portable assays, especially in resource-limited environments, prompts adaptation. Clients developing single-use test strips or microfluidic devices rely on our willingness to modify standard particle size, packaging form, or purity grades. We’ve scaled up pilot batches of Gallein impregnated on fibrous carriers, as well as custom blanks for color calibration. Our willingness to experiment in packaging and quality control methods aims to reduce customer development time, where off-the-shelf grades might fall short.
Technicians and researchers often approach us with results from non-standard systems—pH gradients, mixed-metal matrices, or polymeric test strips. Our in-house expertise allows us to suggest adjustments that sharpen response times or increase shelf-life under harsh storage. Unlike in mass-market commodity chemicals, our relationships tend to last years as projects evolve. This constant feedback loop keeps manufacturing standards dynamic and linked to market trends, not just past reputation.
Safety has always underpinned responsible chemical production, and Gallein’s relatively low toxicity compared to some organic dyes bolsters its acceptance in academic and industrial settings. Decomposing Gallein in waste streams avoids creating hazardous by-products, so both lab disposal and large-scale wastewater treatment integrate smoothly into standard protocols. Our technical support encourages best practices in handling, such as working in well-ventilated spaces and using suitable personal protective equipment, particularly during weighing and dissolution steps where fine powders may carry inhalation risk over repeated exposures.
Packaging design reflects our commitment to minimizing environmental impact. Container sizes suit end-user needs, preventing waste from expired or leftover material, and we review all packaging for recyclability. As zero-waste laboratory initiatives gain traction worldwide, customers increasingly require environmental impact statements and waste minimization support, which our team provides with clear, actionable guidance. Few customers want surprises linked to disposal, and our transparent documentation aims to provide confidence in using and discarding Gallein responsibly.
Working as a chemical manufacturer, we recognize Gallein’s place extends well beyond a line on a catalog. Generations of researchers and technicians have built confidence in its performance through thousands of successful tests, process runs, and research breakthroughs. Our ongoing responsibility lies in not only maintaining quality and supply, but also adapting to new requirements and challenges presented by users working at the boundaries of detection or process control.
Direct feedback from end users fuels our improvements—whether in the subtle refinement of synthesis steps, packaging design, or end-use support for novel applications. The stable foundation Gallein offers in sensitive measurement workflows allows our clients to meet tighter regulatory requirements, achieve greater operational efficiency, and deliver results that stand up to close scrutiny. We value the trust built through every shipment and conversation, knowing the difference between an average indicator and a reliable one can ripple through the supply chain, from process technician to final product end-user. This attention to every production detail, rooted in practical experience, defines our long-term commitment to quality and service in the evolving landscape of specialty chemicals.