West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Fluorescein Diacetate

    • Product Name Fluorescein Diacetate
    • Alias FDA
    • Einecs 246-410-1
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    738603

    Product Name Fluorescein Diacetate
    Chemical Formula C24H16O7
    Molecular Weight 416.38 g/mol
    Cas Number 596-09-8
    Appearance Yellow-green crystalline powder
    Solubility Soluble in acetone, DMSO, ethanol
    Storage Temperature 2-8°C
    Purity ≥97%
    Excitation Maximum 494 nm
    Emission Maximum 518 nm
    Usage Cell viability assays
    Melting Point 176-178°C

    As an accredited Fluorescein Diacetate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Fluorescein Diacetate (Sigma Aldrich, 1g) is supplied in a sealed amber glass vial with screw cap, labeled for chemical use.
    Shipping **Shipping Description for Fluorescein Diacetate (Sigma Aldrich/Merck/TCI Chemical Grade):** Fluorescein Diacetate is shipped in tightly sealed containers, protected from light and moisture. It is typically transported at ambient temperature unless otherwise specified, following standard chemical safety regulations. Ensure labeling with hazard information and handling instructions as per SDS. Handle with care to avoid spills or exposure.
    Storage Fluorescein Diacetate should be stored in a tightly closed container, protected from light and moisture. Keep at 2-8°C (refrigerated) to maintain stability. Avoid exposure to air for prolonged periods to prevent hydrolysis. Store in a cool, dry, and well-ventilated area, away from incompatible substances and strong oxidizers. Always follow the manufacturer's and safety data sheet (SDS) recommendations.
    Free Quote

    Competitive Fluorescein Diacetate prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Fluorescein Diacetate: Consistent Performance for Reliable Fluorescence Testing

    The Value of Quality-Controlled Manufacturing

    Fluorescein Diacetate (FDA) offers labs and researchers an important option for cell viability and enzyme activity assays. This small, pale yellow compound unlocks its fluorescent potential only after entering the cell and interacting with esterases, providing a reliable and clear test for those probing cellular function. When companies look for a source of FDA, the consistency in purity and handling shapes every assay result. Over the years, our direct oversight at the manufacturing stage—never relying on outside resellers or contract blenders—means we can address every detail, from batch reproducibility to handling protocols that protect this moisture-sensitive molecule.

    Our Model, Specs, and Control Points

    Every batch starts with pharmaceutical-grade raw materials tracked through a Manufacturing Execution System, ensuring tracability that aligns with demands from academic researchers and regulated biotech. We crystallize and purify the compound under nitrogen to keep out contaminants and moisture, which especially matters for FDA’s integrity. HPLC purity for our product regularly runs at or above 98.5%, and we monitor acetyl group retention with in-process checks. Our powder ships as a stable, free-flowing material for fine weighting and solution preparation.

    Moisture and atmospheric handling get extra attention in our facility. FDA’s acetyl groups react readily with water, which can deactivate the molecule before it even gets to the user’s bench. After purification, quick transfer into foil-sealed vials under dry nitrogen prevents activity loss. Our storage area runs below 2% humidity, monitored round-the-clock. Many years of direct feedback from cell culture labs showed that batches exposed to moisture, even for brief periods, lose their esterase-reactive properties and generate weak fluorescent signals. We prevent that loss with a robust sealed packaging process.

    Why Labs Choose Direct-Manufactured FDA

    Labs working with cell viability—especially those relying on flow cytometry, fluorescence microscopy, or rapid field tests—depend on reagents that work every time, not just on the day of opening. FDA by its nature requires this trust. Our approach as a direct manufacturer—no intermediaries, no warehouse time on distributor shelves—removes weeks where temperature, humidity, or accidental light exposure could take their toll on product activity. This detail matters most for high-throughput experiments, time-sensitive viability studies, and for quality control labs that retain reference vials for long-term archival.

    Several times each year, customers bring us failed or inconsistent results from product batches sourced from traders and blend houses. These often show up as powders that clump, discolor, or fail sterility checks. When we analyze these, the causes are usually simple: moisture ingress or improper storage en route. Our own tracked delivery and batch-dated fulfillment protocols cut out such risks. In our experience, having a direct line to customer feedback helps us constantly adjust and improve—from fine-tuning mesh size for easier solubilization, to adding double packaging on bulk shipments when customers in tropical climates raised a concern.

    Real-World Usage: From Microbiology to Plant Physiology

    Researchers usually approach us with questions about FDA for either animal cell viability testing or esterase activity assays, but over the years we’ve supplied custom lots for a surprising array of studies. In wastewater assessment, scientists use FDA to rapidly distinguish between living and dead bacteria. The same is true in plant biology, where chlorophyll’s strong green fluorescence often masks weaker stains—here, FDA’s clear blue-green emission provides a contrast even in plant root cells. Our direct communication with end users let us track common troubleshooting concerns and share optimization advice drawn from hundreds of case studies, not hearsay or secondhand product info.

    Our direct manufacturing means we can make quick adjustments: adjusting particle size for labs using microinjectors, issuing certificates that pinpoint the batch’s actual ester hydrolysis potential, or running accelerated stability studies for users in field-deployed mobile labs. One customer, interested in amphibian embryo viability, requested a run with higher-than-normal purity and we obliged by tweaking the crystallization protocol for a tighter retention of acetyl groups. Another research group conducting environmental stress studies in arid regions secured extra desiccant packs in every shipment after direct discussions with staff. These interventions come straight from firsthand experience, not distributor checklists.

    Purity, Stability, and Storage for Demanding Researchers

    For enzyme activity and live/dead cell assays, the very acetyl groups that tag FDA as “diacetate” are the same groups that must stay untouched until they meet the target esterase. This action spotlights the difference between stable, high-purity material and product that’s lost integrity during long, multi-step trading. Our track-and-trace system proves its worth every year as university and private labs audit us for source data—confidence in raw material, batch release analytics, and proof of controlled humidity from day one.

    Too many labs underestimate the damage done by even a brief exposure to water vapor or high temps. A dedicated packaging line—handling only FDA and related esterase substrates—keeps out cross-contamination and accidental oxidation. Our freezers are validated to control temperature swings; every item ships with documentation on last-opened, last-packed dates, along with electronic tracking if customers need proof of cold-chain custody.

    Quality Differences Compared to Generic or Trader Stock

    We have visited many facilities overseas and in domestic markets where FDA comes in from bulk intermediaries. At these plants, the material often sits for weeks, sometimes in heat, sometimes in high humidity. Sometimes powders are repackaged under ordinary air, the clumping and odd coloring are chalked up to “normal variation.” But our tests find low esterase-reactivity, off-odors from breakdown products, or, in the worst cases, low-level contamination with solvents from intermediate processing steps. None of these issues crop up in FDA manufactured start-to-finish under direct environmental control using food/pharma grade vessels. This is the backbone difference between something made to stock and something made to perform.

    Every batch carries a production log, kept on file for a minimum of six years, allowing forensic trace-back in case any user queries a performance issue. This transparency gives lab managers and quality supervisors peace of mind, especially as regulatory expectations rise for traceability and reliability in test reagents. We do not rely on generic certificate language; exact test methods and batch-specific purity are open for scrutiny anytime. That “nothing to hide” approach cannot be retrofitted to a product that passed through multiple untracked hands.

    Why Handling and Transport Shape Assay Results

    Even the best-manufactured FDA degrades fast if left in high humidity or under light. We learned the hard way, years ago, as customers moving to mid-summer climates reported sudden drops in fluorescence. So, we overhauled our packaging with double-wrapped foil vials, research-grade desiccant packs, and rigid-handled, tamper-evident shippers. Courier partners now have explicit instructions on transit conditions. This entire protocol exists because poorly handled FDA almost guarantees disappointing test results—streaky fluorescence, increased background, or outright assay failure.

    Product sample testing doesn’t end on shipping day. We run retain sampling: pulling vials from each batch into storage for 24, 48, and 72-hour stability tests under “worst-case” field deployment scenarios. Customers interested in environmental monitoring can request homogeneity data on vials from different sides of the batch—confirming no hot/cold spots in purity or reactivity. We don’t treat this as optional. Every failure teaches us something about what to improve in the next run, and open feedback from labs keeps us pursuing better protocols, not just paperwork compliance.

    Why Specifications Matter Beyond the Data Sheet

    Labs often compare FDA using published specs—purity by HPLC, absence of known solvents, moisture below a certain percent. Direct manufacturing gives a unique edge when someone requests something specific: a larger pack size for automated liquid handlers, a smaller or larger grain size for customized sample prep, or extra documentation for grant reporting. Generic manufacturers and resellers often keep only a single spec sheet on file, which rarely matches the subtle needs of sensitive cell culture or live imaging. Our QC staff answer technical questions about every metric, from solubility in buffer to recommended solvent pre-treatments. These answers derive from years of hands-on batch development, not just summaries lifted from chemical handbooks.

    FDA doesn’t only distinguish between live and dead cells. In recent years, contract research organizations have requested more data on “background noise”—the subtle differences in fluorescence that crop up if a batch contains trace hydrolysis products, or if the diacetate isn’t uniform. Such background can mask low-level esterase activity, leading to false negatives in critical toxicology or environmental screening studies. Our regular review of QC records often reveals patterns missed by bulk trading: fine temperature spikes, microcontaminant drifts, or batch-to-batch variance in crystal morphology.

    Direct Dialogue Improves Future Batches

    Trading firms and bulk repositories rarely pass along root-cause feedback to their upstream sources. As a direct manufacturer, we have benefited from hundreds of technical interactions describing unexpected results—what worked, what failed, which storage conditions correlated with rapid decline, what solvent blends improved dissolution rates. These reports fuel changes to our SOPs faster than any audit could force. For example, a biotech client reported that plasticizers from generic polystyrene vials tainted weak FDA batches during field transport. We replaced our own secondary vial lining with inert, lab-certified PTFE liners, cutting background autofluorescence by over 60% in internal validation runs.

    Direct orders allow us to manage cold-chain logistics precisely. We coordinate shipment directly to users—even those in distant time zones—allowing reliable project scheduling and minimal handoff risk. Many academic labs rely on temporary postdocs and ever-shifting storage environments; we provide post-shipment QA support, troubleshooting common user errors in reconstitution and storage. Over time, these direct partnerships create a feedback loop that no third-party can emulate, translating field experience back into better, more robust procedures for new production runs.

    Addressing Common Issues in FDA Assays

    Customers most often ask about powder sticking, solution clarity, and sudden loss of fluorescence intensity. Problems nearly always originate from moisture ingress or repeated thaw cycles. Our solution is twofold: providing improved moisture-proof packaging, and educating users with clear, practical reconstitution protocols. For critical-use vials, we offer double-sealed pouches. For customers with unreliable cold storage, guidance on short-term stabilization buffers and workaround protocols is just a phone call away.

    Some labs face difficulties in getting clear readings in dense cell suspensions. Instead of generic advice, we draw from peer laboratories that found optimal concentrations, improved their wash steps, or modified incubation times. This curated, experience-based troubleshooting can mean the difference between a failed pilot and a validated workflow. Over time, we have seen that robust, consistent FDA assays lead to greater research confidence and more reproducible published results.

    Supporting Specialist Applications

    Bulk packing and standardization will serve many diagnostic developers, but niche users—researchers studying rare aquatic species, field ecologists working far from reliable storage, food safety scientists validating rapid pathogen tests—bring unique needs. Our experience manufacturing FDA in both research and field-grade forms means we can adapt to these demands: from microbatched production for small teams to temperature and humidity sensors in outbound shipments. These steps rarely appear in generic product specs but make a decisive difference in tight-margin workflows.

    In one case, a client developing FDA-based soil microbial viability tests needed custom blended buffer salts compatible with their automatic sampler. Our team formulated a lyophilized FDA-cocktail that could be reconstituted on-site, cutting prep time and minimizing error. Input from the user’s environmental techs indicated potential for batch-to-batch loss of activity—field-lab coordination helped us redesign both shipping and storage protocols, resulting in consistently readable data over extended field runs. We repeat this process for any user with site-specific issues, grounding every tweak in hands-on trials rather than blanket assumptions.

    Differences vs. Other Dyes and Viability Assays

    Compared to propidium iodide, trypan blue, or resazurin, FDA stands apart for its clean excitation/emission profile and rapid, direct cell penetration. Its esterase-dependency makes it a prime indicator of not just membrane integrity but active metabolism. Many alternative dyes either require longer incubation or produce ambiguous signals in dense samples due to overlap with endogenous cellular fluorescence. Over decades of production, we have seen FDA preferred in ecology, biotechnology, and medical research for its straightforward readouts and minimal interference with subsequent analyses.

    Overblending with non-compatible solvents (like DMSO in high concentrations) has led some labs to undercut FDA’s unique advantages, often due to advice from catalog merchants with no stake in actual product performance. Our production chemists routinely consult with clients to optimize solvent choices, incubation windows, and photodetection configurations based on actual use cases—not generic product blurbs. This responsive, experience-anchored support has kept FDA a preferred option in rapid-meter, field-deployable tests where speed and clarity matter.

    Continuous Improvement through Persistent Experience

    Years at the core of chemical manufacturing have taught us that a product like FDA serves as more than a simple commodity—every failure to deliver consistent, high-performance material becomes a direct lesson in what to fix next. Feedback about storage faults, blending incompatibilities, or emerging instrument trends triggers updates in our own procedures, with every stakeholder from synthesis staff to packagers involved in downtime analysis and corrective action. Our goal never rests on minimum viability; instead, it sits with the researchers whose results—and funding—depend on transparent, reproducible materials.

    By remaining closely aligned with end users, we keep FDA supply as robust as possible—never “good enough,” always seeking out the next recurring pain points and responding before they turn into barriers to publication or regulatory approval. This philosophy drives not only our day-to-day work, but also our ongoing investment in people and plant upgrades: better chromatographic monitoring, smarter batch tracking, faster response to new compliance needs. If you need a reagent built not by committee but by direct experience, the difference shows itself in every batch.