|
HS Code |
836211 |
| Product Name | 6-Carboxyfluorescein |
| Synonyms | 6-FAM, 6-Carboxyfluorescein free acid |
| Cas Number | 3301-79-9 |
| Molecular Formula | C21H12O7 |
| Molecular Weight | 376.32 g/mol |
| Appearance | Yellow powder |
| Purity | ≥98% |
| Solubility | Soluble in DMSO, DMF, slightly soluble in water |
| Excitation Maximum | 492 nm |
| Emission Maximum | 517 nm |
| Storage Conditions | Store at -20°C, protect from light |
| Lambda Max | 494 nm |
| Pka | 6.4 |
| Usage | Fluorescent dye, labeling biomolecules |
| Melting Point | 272-273°C |
As an accredited 6-Carboxyfluorescein factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 6-Carboxyfluorescein (1g) is supplied in an amber glass vial, securely sealed with a screw cap, and clearly labeled. |
| Shipping | 6-Carboxyfluorescein (Sigma Aldrich/Merck/TCI Chemical Grade) is shipped in tightly sealed, light-protective containers under ambient conditions. Packaging ensures chemical stability and minimizes contamination risk. Standard shipping complies with relevant safety and transport regulations. No refrigeration is required, but avoid extreme temperatures and exposure to moisture during transit. |
| Storage | 6-Carboxyfluorescein should be stored at 2-8°C in a tightly sealed container, protected from light and moisture. Ensure storage in a dry, well-ventilated area, away from incompatible substances such as strong oxidizing agents. Open and handle under low light conditions to prevent degradation. Follow manufacturer's safety guidelines and keep container clearly labeled and out of reach of unauthorized personnel. |
Competitive 6-Carboxyfluorescein prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Nearly every lab technician or research chemist recognizes the lively yellow-green glow of 6-Carboxyfluorescein. Since the first day our team handled the raw material, we realized how distinctive this compound behaves at different phases in its lifecycle. Our batches move through synthesis, purification, and rigorous analysis before they ever reach a scientist’s bench. Season after season, we notice even subtle changes in temperature or input purity will show up during the final crystallization. Mistimed solvent control can lead to clumping or, worse, contamination visible under UV. These hands-on lessons shape how we structure production runs, and they shape the reliability scientists expect from a batch bearing our internal model number FAC-6001.
We manufacture 6-Carboxyfluorescein as a fine, yellow-green crystalline powder. Every gram that leaves the cleanroom comes with a confirmatory spectrum and purity analysis clipped to its lot file, not out of habit, but because a missed peak or a shifted fluorescence maximum means troubleshooting wasted experiments. In real-world laboratory applications, it cannot underperform. People count on this material to give reproducible, bright emission when studying everything from DNA hybridization to real-time PCR. We have learned that even experienced customers prefer knowing lot-to-lot spectral integrity matters as much to us as it does to them.
We keep the assay of our 6-Carboxyfluorescein at or above 98% as determined by HPLC. It took long hours in the QC lab to realize that ultrapure material resists fading under laser loading and minimizes background interference in imaging applications. Every single batch goes through spectral comparison to internal reference samples. Our staff cross-checks peak absorption at 492 nm and emission at 517 nm, using standard buffers and controlled pH to highlight any deviations. While certain applications occasionally allow looser spec materials, we stick to this range to avoid introducing troubleshooting variables researchers don’t have time to chase.
Physical properties turn out especially important for automated dispensing and conjugation projects. Our particle size control narrows the error margin in workflows where slight static or clumping can damage pipetting robots. It’s the difference that separates material that pours easily from material that trickles out unevenly and ruins calibration. Each batch’s free flowing character and low moisture content comes from carefully timed vacuum drying—not simply from luck or a theoretical value. Experienced formulators who use our 6-Carboxyfluorescein for oligo labeling or microarray spotting send us their feedback. They appreciate not having to run extra samples or recalibrate equipment due to unexpected changes in performance.
In the development stage of synthetic oligonucleotides, researchers routinely grab 6-Carboxyfluorescein for its amine-reactive carboxyl group. The simplicity of its conjugation chemistry, coupled with the brightness of its fluorescence, have set a standard for labeling DNA and RNA. We see our batches go into genetics laboratories, environmental monitoring, and even some types of optical sensors due to the strength and fidelity of the signal they provide. Fluorescein, in its plain form, performs for general visualization. The carboxyl derivative steps up the game for researchers needing to couple the dye efficiently to proteins or oligonucleotides with strong covalent bonds.
Our technical support fields questions regularly about the distinct performance differences between 6-Carboxyfluorescein and its close relatives, such as FAM and fluorescein isothiocyanate (FITC). The carboxyl group distinguishes this product for robust coupling reactions in aqueous buffers, maintaining fluorescence intensity without the batch-to-batch labeling inefficiencies seen in some traditional isothiocyanate labeling chemistries. Synthetic biologists and diagnostic developers repeatedly mention how our controlled quality translates to reliable labeling density and uniform fluorescence across multiple runs—something not always achieved with generic reagent sources.
Diagnostics companies developing qPCR and isothermal amplification kits require high-sensitivity probes. Our product serves as the core reporting dye for TaqMan and other hydrolysis probe systems. Every month we run feedback studies with kit developers; even a slight variance in emission intensity leads to flagged batches—delaying product releases and wasting time for project leads. Over the years, our process improvements have targeted those weak spots, which makes a difference for clients whose research timelines often mean the difference between grant approval and missed opportunities.
In environmental applications, researchers track the movement of water and contaminants using 6-Carboxyfluorescein’s stability and clean fluorescence signature. We maintain low background contamination to prevent detection problems—even when working with highly sensitive fluorimeters. Field scientists send us water samples back from field trials, and our QC unit uses them to fine-tune purification strategies, preventing the leaching of fluorescent impurities. This form of continual improvement only comes from long-term product stewardship.
Flow cytometry, multiplex biomarker studies, and high-throughput screening platforms increasingly rely on robust fluorescent standards. We see firsthand how the consistent emission and stability of our 6-Carboxyfluorescein matter in these platforms. Irregularities in dye behavior during multiplexing disrupt gating controls and skew population analyses. As assays have increased in complexity—sometimes requiring dozens of labeling channels in a single run—the importance of predictable fluorescence signature grows. This pressure pushes us to constantly refine our processes and maintain the tightest possible tolerances in the final product.
We keep direct lines of communication open with our customers, not as an “added value service,” but as a crucial part of quality control. Whether batching material for a regional research hub or a multinational diagnostics lab, questions inevitably surface about optimal storage, dissolution, or long-term stability. We’ve gained practical knowledge about the shelf stability and photoresistance of our 6-Carboxyfluorescein under typical transport and benchtop conditions. On rare occasions, a lab working under especially harsh lighting conditions reports minor photo-bleaching. Our R&D unit collaborated with those partners to advise on shielding and to explore stabilizer blends, feeding this experience back into product literature and future production.
Conjugation methods present another learning opportunity. Over the years, we received calls from protein chemists getting lower-than-expected conjugation yields. Direct troubleshooting led us to tweak particle size and surface drying parameters, boosting labeling efficiency with standard EDC coupling reactions. Some biochemists needed a slightly slower rate of dye release for calibration; the solution in their case involved batch-screening and time-based reactivity trials. Each round of feedback creates tighter QC standards and practical datasheets, reflecting our understanding of everyday needs, not just the theory of synthesis.
We maintain full traceability from raw materials to final packaging. Each batch of 6-Carboxyfluorescein comes with spectral data, lot records, and manufacturing dates accessible to end users who request them. This transparency came as a direct response to customer experiences with poor record-keeping from offshore vendors, which rendered earlier projects impossible to validate or repeat. Our chemists archive reference samples for every lot, so that in the rare event of downstream assay variation, we can pull archived material, repeat the analysis, and pinpoint root causes. No one on our team calls this a marketing differentiator—it’s seen as an essential part of being a responsible supplier.
Lab audits and third-party cGMP compliance checks have shaped how we approach documentation. Line operators, supervisors, and managers take ownership of their stages, keeping every worksheet and calibration log up to date. This commitment extends beyond regulatory box-checking—the goal is to build trust, batch after batch. Close collaboration with some of the world’s most demanding research labs sharpened our attention to detail. We recognize how a single batch’s failure impacts not just one customer, but entire project timelines and funding cycles.
Popular alternatives to 6-Carboxyfluorescein include FAM, FITC, Alexa Fluor dyes, and several sulfonated derivatives. Each dye fills its own niche, but years of head-to-head customer testing have spelled out the primary differences. FAM shares the same core fluorophore but tends to be available only as a phosphoramidite or labeled on oligonucleotides, not as a free acid for custom coupling. FITC’s isothiocyanate group makes it popular for labeling, yet it often needs careful pH control and longer conjugation times, which lead to inconsistent labeling densities.
Alexa Fluor dyes and sulfonated analogs frequently offer higher photostability but cost considerably more and sometimes require proprietary conjugation protocols. Researchers who value an affordable, widely-applicable dye with strong coupling chemistry often circle back to 6-Carboxyfluorescein. Our internal trials demonstrated that the carboxylic acid’s straightforward reactivity ensures efficiency and a high correlation between input dye and labeling outcome, an asset in high-throughput workflows and core facilities operating across multiple labeling platforms.
We receive questions about product solubility and buffer compatibility. Over hundreds of customer deployments, we've confirmed that 6-Carboxyfluorescein dissolves quickly in aqueous solutions at neutral and slightly basic pH, supporting efficient coupling without detergent or organic cosolvents. Analytical results confirm that this behavior persists regardless of batch size. Our product’s visible fluorescence offers a straightforward readout that matches or exceeds higher-priced fluorophores under standard excitation sources, reinforcing its broad appeal.
From early on, we adopted greener solvents and minimized hazardous waste in 6-Carboxyfluorescein synthesis. Our process chemists swapped out chlorinated intermediates for less persistent alternatives years before regulations demanded change. On the shop floor, we keep airtight seals to minimize solvent vapor, and any cleaning cycle waste receives treatment before disposal. By switching to renewable energy in certain steps and finding local suppliers for key raw materials, we trimmed both our environmental footprint and overall lead times. Customers who share these sustainability values express appreciation for these efforts—not just in principle, but in their own reporting and procurement choices.
We treat product lifecycle as a continuous process. Shelf-life evaluations in real-time stability studies feed directly back into R&D and customer support. Whether it concerns long-term sample storage or optimal shipment routes, we work with logistics partners to make sure sensitivity to heat and light does not compromise quality. Each case where product degradation surfaced—often in high-humidity climates—triggered another update to our packaging protocols, from double-bagging to desiccant addition and light-blocking material upgrades.
Scaling up laboratory production for industrial biotech and diagnostic projects presents constant challenges. Over the past five years, requests for kilogram-scale product rose sharply as genomics and diagnostics expanded their scope. It took rotating production teams, extended work shifts, and custom batch reactors to support these larger orders. Quality monitoring for larger runs required extra checkpoints. Larger batch sizes raise issues that may not show up during small-scale synthesis, like temperature gradients affecting crystal quality or extended drying times prompting caking.
We experienced setbacks during the early phases of scale-up, including isolated days where uneven mixing led to classically “off-color” product. These brief process deviations taught us more than any standard operating procedure revision could. Manufacturing staff learned to spot inconsistencies by eye, long before instruments flagged them as out-of-spec. Now, scaling batches up or down keeps output both flexible and tightly controlled, balancing ongoing industrial contracts against rush research orders without letting either group down.
The evolving needs of life science, environmental, and diagnostic sectors force continual adaptation. Each customer base, from core genomics labs to industrial fluorescence kit manufacturers, operates with its own protocols, batch size preferences, and performance expectations. Technical support gathers regular feedback to guide process improvements. Some customers asked for larger lot sizes, prompting investment in new reactors. Others sought small-quantity vials for rapid pilot runs. Every tweak to the process or form factor stemmed from a real user need, not from arbitrary product management meetings.
Academic laboratories sometimes buy material in gram quantities, while large diagnostics firms need kilogram-scale shipments for kit assembly lines. Both user groups count on the same purity, fluorescence, and handling predictability, but their risk tolerance and documentation requirements often differ. This split taught us that batch flexibility, transparent recordkeeping, and quick-response logistics anchor long-term relationships more reliably than reliance on cookie-cutter “value propositions.”
Data is now an essential part of every batch’s legacy. Analytical records prove more valuable than glossy product specifications. As newer high-sensitivity instruments enter the market, the pressure to keep spectral and purity standards tight increases. Our chemists share regular data snapshots and absorb feedback into new analytical protocols. For example, researchers running next-generation sequencing report even small variations in reference dye performance have downstream impacts. We respond by tightening acceptance ranges, ensuring today’s 6-Carboxyfluorescein matches the requirements of tomorrow’s workflows.
Recognizing errors or drift in a product line means taking action, from extra staff training to equipment upgrades. Occasionally, instrument recalibrations flagged minute wavelength shifts; after tracing the cause back to lamp aging, the team overhauled the entire schedule, ensuring future results stay reliable. As one of the few vertically-integrated manufacturers focused on 6-Carboxyfluorescein, we treat these challenges not as isolated issues, but as moments that reinforce the culture of factual accuracy and laboratory confidence.
Every decision around 6-Carboxyfluorescein production reflects feedback from researchers, diagnostic developers, and core facility managers. Insights from day-to-day manufacturing, hands-on troubleshooting, and direct communications have shaped everything from process optimization to material handling. Consistent spectral quality, predictable coupling chemistry, and reliable supply became possible only through an ongoing cycle of feedback, technical upgrading, and investment in staff expertise. Each batch leaving our floors speaks to this shared commitment—a commitment grounded in real experience, not marketing speak.