West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

5-Carboxyfluorescein Diacetate

    • Product Name 5-Carboxyfluorescein Diacetate
    • Alias 5-CFDA
    • Einecs NA
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    603627

    Product Name 5-Carboxyfluorescein Diacetate
    Cas Number 216295-12-0
    Molecular Formula C25H17NO9
    Molecular Weight 475.4 g/mol
    Appearance Yellow to orange powder
    Solubility Soluble in DMSO, DMF, and partially in water
    Excitation Wavelength Max 494 nm
    Emission Wavelength Max 518 nm
    Storage Temperature -20°C, protected from light
    Purity ≥95% (HPLC)
    Synonyms 5-FAM diacetate, 5-Carboxyfluorescein diacetoxymethyl ester
    Application Cell viability and cytotoxicity assay
    Stability Stable under recommended storage conditions
    Handling Avoid exposure to light and moisture
    Hazard Irritant; handle with appropriate safety precautions

    As an accredited 5-Carboxyfluorescein Diacetate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing 5-Carboxyfluorescein Diacetate, 100 mg, is packaged in a small amber glass vial with a secure screw cap, labeled by Sigma-Aldrich.
    Shipping 5-Carboxyfluorescein Diacetate is shipped in tightly sealed, light-protective containers to preserve stability. During transit, it is kept at controlled room temperature, avoiding excessive heat, moisture, and direct sunlight. For large quantities or sensitive use, cold-pack shipping may be employed. Complies with applicable chemical transportation and safety regulations.
    Storage 5-Carboxyfluorescein Diacetate should be stored at -20°C, protected from light and moisture. Keep the chemical tightly sealed in its original container, preferably in a desiccator or moisture-proof environment. Avoid repeated freeze-thaw cycles. Store separately from incompatible substances and ensure appropriate labelling. Follow Sigma Aldrich, Merck, or TCI guidelines for safe handling and storage as specified in the product's safety documentation.
    Free Quote

    Competitive 5-Carboxyfluorescein Diacetate prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    5-Carboxyfluorescein Diacetate: A Practical Tool for Modern Cell Studies

    Experience-Driven Innovation in Fluorescent Labeling

    Every time our technical staff prepares a batch of 5-Carboxyfluorescein Diacetate, we recall years of careful experimentation, process development, and raw material screening. Not every dye behaves the same under a microscope, and our teams discovered early on that even the smallest inconsistency in purity changes the results in cellular assays. This product, called 5-CFDA in the lab, has built a reputation among life scientists for delivering reliable and distinct signals, especially when compared with more generic fluorescein-based dyes.

    Model and Specifications: Reflecting Real Science Needs

    We synthesize 5-Carboxyfluorescein Diacetate (CAS 125241-12-3) in controlled, ventilated environments using select solvents and reagents. Typical product is supplied as an off-yellow to orange powder. The molecular formula is C25H14O9, and each batch undergoes strict HPLC and NMR controls; purity specs always exceed 98 percent due to the demands of sensitive biological applications. Researchers in flow cytometry, confocal microscopy, and qPCR assays make clear requests: low residual moisture, consistent stability, and minimal hydrolysis prior to use. We keep these requirements in mind, using desiccated glass packaging or custom aliquots when requested for specific projects.

    Reliable Performance in Cell-Tracing Applications

    Graduate students and postdocs running cell viability assays know the headache of background noise, photobleaching, and false positives. Through regular feedback, we learned that researchers working with 5-CFDA appreciate the sharp, bright green fluorescence after intracellular esterase cleavage, which distinguishes live cells from debris without bleed-through from autofluorescence. Every year, hundreds of novel applications for cell tracking and proliferation studies rely on this property.

    During routine in-house validation, staff scientists compare 5-CFDA alongside derivatives such as 6-FAM or regular fluorescein diacetate. Our experience matches user reports: substitutions often lead to uneven dye loading or loss of signal strength after fixation. With 5-carboxy modifications, cellular retention improves because the additional carboxyl group increases hydrophilicity—an easy-to-overlook improvement unless you spend your afternoons watching dye wash out of live cultures during imaging.

    A Product Built for Flexibility in Modern Cell Biology

    Tenured faculty in immunology or stem cell labs, with tight schedules and demanding timelines, press us about consistency and reproducibility. Under their scrutiny, 5-CFDA continues to demonstrate high photostability, resisting rapid fading when exposed to laser excitation. Over a decade of manufacturing adjustments has resulted in a product that withstands reconstitution in both DMSO and methanol. The stability in solution lets larger labs prepare working stocks a week ahead of major experiments, reducing daily workload and minimizing error from repeated aliquoting.

    Long-term tracking applications such as CFSE-like fluorescence cell tracing, in vitro migration assays, and cytotoxicity screens depend on uniform intracellular cleavage. Since the acetoxymethyl ester bonds in 5-CFDA mask the carboxylic acid groups, the compound remains non-fluorescent and membrane-permeable until it meets endogenous esterases within live cells. After cleavage, the fluorescent form accumulates, making signal intensity an accurate readout for intact, metabolically active cells—a routine need in immunophenotyping and transplantation research.

    Every year, international customers working with primary cells, spheroids, or co-culture systems share their results—sometimes directly, sometimes through published papers. Batch-to-batch consistency becomes critical where statistical data or comparative imaging forms the backbone of the study. Our process engineers monitor each production run, tracking yield, fluorogenic potential, and shelf-life at multiple storage temperatures. Our solution—high purity, moisture control, and robust packaging—comes straight from years of troubleshooting real-world issues, not just theoretical compliance to pharmacopeial standards.

    Beyond Commodity Dyes: What Sets 5-CFDA Apart

    The global market overflows with labeling reagents, many boasting high substitution numbers, enhanced water solubility, or special buffering salts. What matters to users, from our daily dialogues with core facility staff, is predictable excitation/emission—here, excitation at 492 nm and emission at roughly 517 nm. Many competing products show broad, overlapping spectra, rendering them less suitable for multiplexing applications. Standard fluorescein diacetate stains paint everything with the same wide brush, often failing in systems where the difference between live and compromised cells hinges on fine shifts in fluorescence.

    Companies that simply repack or relabel generic dyes rarely see the failed tests or wasted sample hours that come from heightened background signals or inconsistent loading. Manufacturing at source gives us immediate feedback—if a reaction batch produces minor side-products, we adjust purification or halt synthesis, protecting quality. When supply problems emerge from hazardous waste, solvent source, or packaging instability, it’s our responsibility to diagnose and correct for the next batch, drawing on direct experience, not procurement policy.

    Academic projects chasing long-term cell-tracing or real-time imaging find most generic acetate dyes quick to leak or degrade when left at room temperature. Many of our returning customers come to us specifically after being disappointed by rapid photobleaching or uneven cell labeling from other brands. The chemical stability we achieve—measured in standard photobleaching curves and extended real-sample imaging—comes not from paperwork, but repeated bench testing under real cell line conditions, using standard incubators, media, and buffer compositions.

    Applications: Real-World Examples From Cell Science Labs

    Bioassays rarely play out the same way from week to week. Some teams need to label hundreds of samples for multi-color flow experiments; others work in dimly lit rooms, mapping single-cell migratory tracks over hours or days. In immunology, 5-CFDA forms part of cell vitality panels alongside propidium iodide or 7-AAD, ensuring sharp contrasts between living, dying, and dead populations.

    Researchers focused on stem cell expansion rely on persistent, non-toxic labeling to follow cell lineage decisions over multiple passages. Here, rapid esterase hydrolysis and low cytotoxicity make a difference: toxic residuals halt differentiation or stress cells, introducing error. Through comparative toxicology, we set stringent thresholds, removing any lot that falls outside our narrow guidelines—even when it complicates inventory flow.

    Environmental labs apply 5-CFDA to quantify viable microbial populations among environmental isolates or biofilms, exchanging monthly emails about troubleshooting sample prep or imaging delays. The dye’s clear separation from natural autofluorescence simplifies interpretation in environmental matrices, even when water quality or matrix effects change day to day. In infection diagnostics, 5-CFDA makes short work of separating live pathogen load from debris, supporting rapid decision-making in clinical settings.

    During months with shipping delays, some customers report extended storage times. Our team documents shelf-life at -20°C and room temperature, maintaining photosensitivity by using dark amber silica-packed vials, sometimes at our own expense to prevent inadvertent loss of signal. The difference is measurable: hydrated or compromised dye gives uneven signals, a lesson learned from hard-won user advocacy years ago.

    Product Handling: Lessons From the Bench

    Every cell biologist has a story about uneven dye uptake, clumped cells, or unreadable signals just when grant deadlines loom. Our years synthesizing and testing 5-CFDA reinforce certain best practices. Dissolve powder using fresh anhydrous DMSO, create single-use aliquots to avoid freeze-thaw, and store in the dark at low temperatures. Exposure to air humidity leads to early hydrolysis—crucial details that don’t always make it into protocols. We brief every returning customer on these points, updating documentation after direct feedback.

    Switching to 5-CFDA from dyes with poor membrane penetration usually increases labeling reliability on hard-to-transfect or slow-growing cell types. The parent molecule’s acetoxymethyl diester structure, unlike standard hexanoate or succinimidyl labels, gives optimal balance between hydrophobic transport and rapid unmasking inside viable cells. This structure means less dye is wasted on dead cells or extracellular matrix, sharpening resulting data.

    Routine technical support from our chemists covers more than pH adjustment or dilution questions—troubleshooting focuses on preventing precipitation in aqueous buffers, confirming esterase activity, and eliminating background bleed-through during downstream imaging. Our records show that wasting even a few batches of precious primary cells due to clumpy or inactive dye costs researchers weeks of lost time. Sharing these practical stories, we aim to prevent similar frustration among new users.

    Differences From Other Products Illustrated by Hands-On Testing

    Comparison runs with other carboxyfluoresceins or FITC derivatives quickly highlight differences in cell retention and signal strength under real microscopy conditions. Products lacking the additional carboxyl group clear from the cell faster, especially during protracted washing or prolonged imaging. Teams working with adherent cell lines or migratory cultures note sharper, more persistent boundaries with 5-CFDA, compared to generic fluorescein acetate or even some expensive “advanced formula” labels.

    Some users switch to water-soluble dyes expecting improved uniformity, only to complain of rapid photobleaching or hard-to-dissolve precipitates at higher concentrations. Through repeated process control and raw material audits, our batches deliver consistent solution clarity and reliable usability every time, traits essential to busy high-throughput labs.

    Shortcuts during storage or careless reconstitution lead to rapid hydrolysis, reducing available functional dye. Our manufacturing logs show why strict packaging and handling rules extend product lifespan and supply real reproducibility, especially for teams running comparison studies or multi-lab collaborations. Direct feedback loops with users help us tweak drying times, packing density, and storage recommendations, ensuring our real-world practice matches laboratory needs.

    Solutions: Satisfying the Challenging Demands of Cell Science

    Preparing usable aliquots in customized quantities emerged from our first orders with large screening labs. Not every team runs full plates at once, so broken-down batch shipping limits wastage and cost overrun. Miniaturizing delivery, scaling up purity targets, and using improved grade silica for moisture protection developed thanks to conversations with core facility managers forced to stretch budgets.

    Where some cell dyes fail in live/dead separation or rapid tracking, our technical teams work directly with users to refine protocols and provide troubleshooting. Real-world testing—with actual cell lines, patient-derived samples, and engineered tissues—exceeds the reliability seen in published protocols or datasheets. Every revised instruction slips back into our packets, shrinking the gap between theoretical product use and day-to-day success in high-volume facilities.

    Seeing a published experiment use our dye accurately for three, six, or even ten days of imaging underlines why small differences in hydrolytic stability, photostability, or solubility matter. The real test of any labeling reagent comes not from paperwork or specs but from clear, replicable signal in tough, variable systems. Our approach—rooted in feedback, manufacturing refinement, and years of user interaction—shows that even in a saturated market, direct manufacturing responsibility drives quality and innovation.

    Continuous Improvement Built From Real Feedback

    Each year, direct scientist feedback leads to new tweaks—spray-dried versus lyophilized forms, ultra-dry packaging, or custom blended stocks to fit automated plate handlers. Experience shows that subtle process changes, whether in crystallization or packaging, develop not out of marketing goals but from actual user troubleshooting.

    Large pharmaceutical research labs demand detailed certificate of analysis with clear chromatograms, structure confirmations, and impurity profiles. Smaller startups, working with a handful of plates at a time, look for manageable aliquots and streamlined technical support. No two customers run studies the same way, so lessons learned from hundreds of fielded technical support calls, failed assays, and corrected shipments drive updated specifications and production adjustments.

    In the rare event that an unexpected impurity or inconsistency arises, we immediately share findings with users, revising storage or reconstitution advice rather than relying on static paperwork. This approach—integrating manufacturing experience, bench-level problem solving, and open dialogue—forms our real contribution to the use of 5-Carboxyfluorescein Diacetate in cell biology.

    Conclusion: 5-Carboxyfluorescein Diacetate Born From the Needs of Working Scientists

    From raw chemical selection to final shipping label, practical experience guides every production decision for our 5-CFDA. User stories don’t just fill testimonials—they guide weekly process meetings and manufacturing refinements. Each adjustment, whether for a packaging tweak or synthetic optimization, reflects a real challenge faced in the field, never just an abstract market trend.

    This down-to-earth perspective helps us deliver a dye that meets stringent requirements—intense, photostable fluorescence, clear discrimination of live cells, low cytotoxicity, and robust performance over multiple days. As the end users—technicians, graduate students, principal investigators—continue to stretch the boundaries of cellular imaging, our commitment holds: we produce chemicals that solve real laboratory problems, building both trust and results with every batch.