HS Code |
234710 |
| Product Name | 2',7'-Dichlorofluorescein [for Fluorescent indicator] |
| Cas Number | 76-54-0 |
| Molecular Formula | C20H10Cl2O5 |
| Molecular Weight | 401.20 g/mol |
| Appearance | Light yellow powder or crystals |
| Purity | Typically ≥98% |
| Solubility | Slightly soluble in water; soluble in ethanol and acetone |
| Excitation Wavelength | Approximately 502 nm |
| Emission Wavelength | Approximately 524 nm |
| Melting Point | 308-310°C |
| Storage Conditions | Store at 2-8°C, protected from light |
| Hazard Class | Irritant |
| Synonyms | DCF; 2',7'-Dichlorofluorescein sodium salt (as sodium salt form) |
| Application | Fluorescent indicator; tracer for reactive oxygen species |
| Ph Sensitivity | Fluorescence increases in basic pH |
As an accredited 2',7'-Dichlorofluorescein [for Fluorescent indicator] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging is a 5g amber glass bottle with a secure screw cap, labeled with product details and safety information by Sigma Aldrich. |
| Shipping | 2',7'-Dichlorofluorescein [for Fluorescent Indicator] (Sigma Aldrich/Merck/TCI Chemical Grade) is shipped in tightly sealed, labeled containers to prevent contamination and light exposure. Packaging complies with safety regulations, including hazard labeling if necessary. Temperature conditions are monitored; typically, standard ambient temperature shipping is used unless otherwise specified by the manufacturer. |
| Storage | Store **2',7'-Dichlorofluorescein [for Fluorescent indicator]** in a tightly sealed container, protected from light and moisture. Keep at room temperature (15–25°C), away from incompatible substances and sources of ignition. Use only in a well-ventilated area and handle with appropriate personal protective equipment. Follow applicable local, state, and federal regulations for chemical storage and disposal. |
Competitive 2',7'-Dichlorofluorescein [for Fluorescent indicator] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
For years, our plant has manufactured 2',7'-Dichlorofluorescein at scale, working in the frontline of production rather than behind a desk or at a reseller’s warehouse. I see the raw materials go in, the color changes in the reactors, the careful drying, and the routine batch checks that show how real-world production can differ from lab notes. Product batches don’t just reflect numbers on a COA — they capture nuanced changes in material grade, batch-to-batch consistency, and controllable levels of trace impurities.
Our commercial-grade 2',7'-Dichlorofluorescein comes primarily as a fine, vibrant orange solid. Chemical formula C20H10Cl2O5, with a molar mass of 401.21 g/mol. We maintain moisture below 1%, residual solvents below 100 ppm, and heavy metal traces below accepted research levels. The powder has a characteristic orange tint, and products leave the factory sealed against light to trap its stability during transport. Each batch includes a crystalline microscopy check alongside the HPLC assay, which keeps down batch deviation.
Most customers ask about indicator grade purity and spectral response. Back in the lab, after producing the raw material, we test batches in indicator-grade conditions. Under excitation between 485–500 nm, with emission typically peaking around 525 nm, our 2',7'-Dichlorofluorescein keeps up with analytical standards needed for pH measurement or trace peroxide testing in environmental analytics. With a high quantum yield and low background fluorescence, the lot-to-lot consistency tightens up titration endpoints and brings more confidence to colorimetric or fluorometric assays.
Other fluorescent dyes can look similar on paper. In everyday laboratory use, trace byproducts such as mono-substituted fluoresceins can bleach signals or dampen contrast. During our own in-house trials, I’ve seen some off-spec commercial 2',7'-Dichlorofluorescein cause faded green hues or poor photostability. Our facility focuses on controlled synthesis and selective crystallization, providing a dye with robust photostability during standard illumination cycles. The addition of an extra chlorine atom compared to standard fluorescein increases acid dissociation and shifts color response toward sharper transitions — highly relevant in pH-sensitive experiments or as an endpoint indicator in blood serum analysis.
Lab chemists who have switched from broad-market fluorescein variants to our 2',7'-Dichlorofluorescein frequently send feedback on lower background noise in colorimetric quantification, smoother endpoint changes, and improved signal detection in automated titrators. In direct side-by-side use with unsubstituted fluorescein, our product requires less dye loading for equal fluorescence, demonstrating stronger molar absorptivity.
Routine experience in the plant shows that product color reaches a deeper orange hue, with finer crystalline texture than generic competitors. Those minor physical clues mean better dispersibility in both water and organic solvents. In practice, lab techs using our indicators see visibly sharper color transitions at endpoint, especially under moderate lighting conditions — a reflection of careful impurity control during purification. Even a small uptick in purity can shave off minutes from titration experiments, remove the ambiguity on color changes, and help laboratories keep to tight schedules and compliance deadlines for critical reporting.
Not all producers treat light protection or residual solvent elimination as seriously as we do—not because standards are impossible to meet, but because these control steps slow down batch output and increase per-kilo costs. By prioritizing batch stability and robust containerization, our process delivers a dye fit for critical clinical chemistry and water quality control tasks, not just everyday research usage.
In practice, 2',7'-Dichlorofluorescein finds its main use as a fluorescent indicator in analytical titrations, trace peroxide quantification, and environmental pH monitoring. Over the years, clients have adapted the product to additional uses such as micellar electrokinetic chromatography, tracer studies in flow experiments, and as a visible marker for system leak testing. The dye exhibits strong response in alkaline and slightly acidic range, serving as a clear visual cue in lab and field environments alike.
One industrial water testing company shared that reliable 2',7'-Dichlorofluorescein signal response allowed them to automate endpoints in dye-based chlorine and peroxide detection. Inconsistent dye quality previously set off false alarms or flat-lined signals; since switching over, their results track much more closely with instrumental reference checks, helping them save both time and consumables. Both large environmental labs and university teaching facilities have mentioned improved reproducibility in group assays, shortening time spent re-running stopped reactions for calibration.
Building genuine trust with seasoned laboratory users means not only hitting analytical numbers but delivering a product that responds well to lighting, varying temperature, and solvent quality found in non-ideal lab settings. Our in-house QC team has had to flag batches for reprocessing whenever even minor TLC spots deviate or background absorbance bumps go above 0.15 at 480 nm in blank buffer. Each time a customer notifies us about a tough result, production reviews shift to root cause checks on crystal size and dye oxidation history.
Holding purity at 98% or above, and keeping isomer byproducts below 2%, doesn’t happen just by following textbook synthesis. Our plant operators adjust temperature ramps and solvent ratios depending on humidity and live sensor data. This hands-on approach minimizes batch recalls and saves customers extensive trouble in recalibrating their indicator stock solutions. When environmental monitoring teams run hundreds of pH or peroxide tests per day, even a single percent drift in dye baseline can create regulatory headaches. From manufacturing to purification and QC, our plant teams know every detail piles onto end-user confidence.
2',7'-Dichlorofluorescein’s stability hinges on protection from heat and light. Over the years, our packaging lines have shifted to UV-blocking amber glass and multi-laminate barriers, based on accelerated aging studies and direct feedback from field storage locations. Unprotected, open-bench samples fade visibly in just a few days.
Typical shelf life at controlled temperature (below 25°C) runs at least 24 months, with photostability holding for 18 months under closed container conditions. Labs facing long distribution chains or field operations in high-heat areas have benefitted from our shift to smaller aliquot packaging, cutting down on partial-unit spoilage. Regular batch re-testing, including Open Vial Challenge protocols in bright conditions, helps our QC keep shelf life claims realistic and traceable.
Traditional fluorescein, even at upper purity, can have trouble maintaining signal intensity in highly buffered or slightly oxidized solution. In multi-use settings, residual background fluorescence can undermine low-concentration assays and complicate result interpretation. Adding two chlorine atoms on the aromatic ring, as in 2',7'-Dichlorofluorescein, boosts performance under variable ionic strength, provides sharper visual transitions, and improves acid-base sensitivity. Field data and customer side-by-side tests show reduced need for blank corrections and tighter endpoint clustering in titrations.
The increased hydrophobicity imparts higher stability in organic solvents compared to standard fluorescein, expanding compatibility with advanced analytical platforms. Some clients in pharmaceuticals have successfully used the dye in complex organic extractions without significant degradation or dye carryover, saving them cleanup steps and post-assay work.
For grad students or contract chemists moving between generic dyes and dedicated indicator products, our batches of 2',7'-Dichlorofluorescein stand out on both solubility and fluorescence lifetime. A fraction of our repeat demand comes from users who started with off-label dyes and found poor transition sharpness during endpoint color changes.
Each week, our plant schedules multiple 2',7'-Dichlorofluorescein reactions, each batch needing close attention from the first addition of phthalic anhydride to the final drying steps. Operators track not just color shifting in the mix, but changes in filter resistance and crystal growth rates, correlating live batch data with historical trend records. On-the-job experience shows that small tweaks—a one-degree shift in the crystallization bath, or a one-hour difference in drying—can push the batch towards higher purity or easier filtration. Our crew sees direct results reflected in the color, particle size, and even in how the product pours.
Repeating customer orders bring in real-world feedback from scientists and technicians. Common themes include shortened experiment times, more vivid endpoint color changes, and more stable stock solutions. Several high-volume water monitoring sites mentioned that moving from “lab grade” to our production-focused grade reduced data variance in regular site audits. A few university instructors shared that teaching groups had better results in side-by-side titration labs, with students confirming endpoint changes more quickly.
Our own team has caught and addressed contamination issues—such as trace iron-from vessel gaskets—that briefly altered dye response years back. These lessons pushed us to upgrade gasket materials, reinforce cleaning procedures, and increase in-process QA sampling points. Occasionally, we trial alternate purification flows to coax up yield or remove trace colored byproducts left by over-processed batches from other sources. Rarely does a competitor’s generic lot pass our side-by-side tests for color intensity and endpoint clarity.
Producing 2',7'-Dichlorofluorescein represents more than achieving a technical synthesis—it demands real vigilance against batch slips and micro-contaminants. With each lot, we take sample aliquots from sub-batches and run them both through HPLC and functional fluorescence assays. Several years ago, incomplete solvent sweeps left a handful of lots with background peaks in UV-Vis scans, which we only discovered after a downstream client ran into unexplained titration noise. This incident reminded us to keep a strict solvent flush on final crystals.
Continuous improvement in manufacturing comes not just from tighter specs, but from experience tracking outcomes in real-world analytics. We revisit protocols after any unusual complaint, even if it’s just a marginal endpoint fade. Regular engagement with customer labs drives upgrades in both plant controls and after-sales support, keeping operational feedback flowing from bench to reactor floor.
Meeting demand for high-grade 2',7'-Dichlorofluorescein goes beyond the raw product. Solutions like same-lot reserve supply, custom packaging sizes, and after-sales guidance for indicator use have emerged directly from customer requests. Several reference labs have pointed out that supply chain stability matters as much as technical grade or purity. We’ve adapted batch reservation programs and improved fulfillment scheduling so clients can count on uninterrupted usage for critical experiments and contract analyses.
As a manufacturer, standing beside users through troubleshooting and calibration gives us deeper insight into how chemical quality links to real outcomes—whether in municipal water labs, university teaching courses, or industrial process audits.
As someone working daily with this product, I see the tangible results of months of process optimization, operator training, and customer feedback loops. We treat every batch of 2',7'-Dichlorofluorescein as a proof point for our reputation—not only in analytical benchmarks but in reliability from the factory up to the point of use. This day-to-day dedication ensures researchers and field users receive a fluorescent indicator that consistently meets high expectations in clarity, stability, and performance.