|
HS Code |
894064 |
| Chemical Name | 2',7'-Dichlorodihydrofluorescein Diacetate |
| Synonyms | DCFH-DA |
| Molecular Formula | C24H16Cl2O7 |
| Molecular Weight | 487.29 g/mol |
| Appearance | Off-white to pale yellow powder |
| Cas Number | 4091-99-0 |
| Solubility | DMSO, ethanol, slightly soluble in water |
| Storage Temperature | -20°C (protected from light) |
| Purity | ≥98% |
| λmax Absorption | 504 nm (after oxidation) |
| Application | Fluorescent probe for detection of reactive oxygen species (ROS) |
| Stability | Light-sensitive, air-sensitive |
| Melting Point | 173-175°C |
| Ph Sensitivity | pH-sensitive after oxidation |
As an accredited 2',7'-Dichlorodihydrofluorescein Diacetate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 2',7'-Dichlorodihydrofluorescein Diacetate (Sigma Aldrich, 100 mg) is packaged in a sealed amber glass vial for light protection. |
| Shipping | 2',7'-Dichlorodihydrofluorescein Diacetate (Sigma Aldrich/Merck/TCI Chemical Grade) ships in a tightly sealed, light-protective container under ambient or refrigerated conditions. The package includes proper hazard labeling and documentation. Transport follows chemical safety regulations to prevent exposure to moisture, heat, or light, ensuring product integrity and compliance during transit. |
| Storage | **2',7'-Dichlorodihydrofluorescein Diacetate** should be stored in a tightly sealed container, protected from light and moisture, at 2–8°C (refrigerated conditions). Avoid exposure to air and high temperatures to prevent degradation. Store in a cool, dry place, and segregate from incompatible substances such as strong oxidizing agents. Ensure proper labeling and access only to trained personnel. |
Competitive 2',7'-Dichlorodihydrofluorescein Diacetate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Many research labs rely on 2',7'-Dichlorodihydrofluorescein Diacetate (DCFH-DA) as a cornerstone indicator for detecting reactive oxygen species (ROS) inside cells. From our perspective in chemical production, this compound represents the fusion of careful synthesis and close attention to the requirements of biological research. Over years of hands-on manufacturing, direct feedback from end users has consistently driven our processes toward finer control and reproducibility. Here, I want to shed light on exactly what researchers look for in DCFH-DA, how these needs have shaped our approach, and what actually separates our DCFH-DA from other general ROS probes.
DCFH-DA manufacturing calls for more than just pure raw materials and tight reaction controls. We built our process around consistency, confirmed at every step with rigorous analytical techniques. High-performance liquid chromatography (HPLC) tracks the purity batch after batch. The goal isn’t just purity numbers; it’s protecting researchers from ambiguous background signals and giving confidence in the assay results. We’ve also found that minimizing trace impurities translates to lower background fluorescence, which matters immensely in experiments seeking to quantify subtle oxidative changes inside a live cell.
Researchers have shared stories about inconsistencies with off-brand sources, where crystals look fine but hidden contaminants sneak into experiments. Such problems might seem small at scale, but at the single-well level in microplates, they can derail an entire week’s work. Regular direct feedback loops keep us tuned into the needs of users who know exactly how compromised data wastes both money and intellectual effort. That's why our batches emphasize documented traceability, so every vial arrives with confidence behind it.
The main points of emphasis for DCFH-DA involve purity, stability, and solubility. We regularly see academic and industrial partners inquire about purity levels above 98%, and our own data has pushed us to confirm HPLC purity within 0.3% batch-to-batch. In practical terms, this minimizes artefactual readings that can occur due to decomposition byproducts. The melting point and storage stability both reflect the effectiveness of our final crystallization and the conditions that preserve the acetate groups from unwanted hydrolysis. Every lot moves from synthesis straight through multiple checks for moisture content and probe stability under various shipping and storage conditions.
For solubility, we focus on rapid dissolution in DMSO and common biological buffers. Some users work in high-throughput screening settings, while others handle only a handful of wells at a time. We’ve tailored our standard particle size to flow freely in automated dispensers but not form dust or static problems in daily pipetting. After years working closely with pharmaceutical partners, we found that smaller lots, sealed in low-binding vials, preserve both convenience and cleanliness for most hands-on experiments.
Not all DCFH-DA on the market is created with the same application in mind. From early days, our process focused on producing material well suited for live cell and in vitro tissue work, where contamination from aromatic trace solvents or heavy metals can disrupt cellular health even before ROS detection starts. The current main model we offer, derived from over ten years of feedback and adjustment, achieves above 99% purity by HPLC and remains stable after repeated freeze-thaw cycles, which fits workflows in both industrial and academic environments.
Pack sizes range from 10 mg up to several grams. We’ve refined everything from bottle material to labeling specifications after hearing from lab managers about solvent compatibility and tracking needs. Our research partnerships showed that a lot of waste comes from over-large vials and unclear tracking codes, inspiring us to streamline batch numbering and include more robust product information on each label. This direct focus on usability came straight from our experience — the person opening the vial is rarely the one who ordered it, so clarity prevents mistakes.
DCFH-DA enters the cell membrane due to its diacetate groups. Intracellular esterases then cleave off the acetate, trapping the non-fluorescent DCFH inside. ROS presence oxidizes DCFH to DCF, which emits a strong green fluorescence measurable by both flow cytometry and fluorescence microscopy. Over the years, we’ve verified our batches side-by-side with recognized standards across multiple platforms. ROS detection remains a notoriously finicky application — false positives, photobleaching, and cellular toxicity can mislead even diligent scientists. Consistent batches translate to lower experimental drift, and supporting data from partner labs continues to confirm minimal background signal and high conversion efficiency in cell-based models.
Researchers in neurobiology, immunology, and even plant sciences have reported that our DCFH-DA behaves reliably across cell types from mammalian neurons to human cancer lines and Arabidopsis seedlings. The shared requirement here: minimal byproducts that would artificially shift fluorescent readings, especially under light and oxygen-rich conditions. We developed post-synthesis air exclusion protocols, which have held up well under both internal tests and external scrutiny. Many competitors may skip this step; our experience shows that such shortcuts often become apparent only months later in sensitive, longitudinal cell studies.
Commercially, people sometimes ask why not just use other common ROS probes, like DHE (dihydroethidium) or CM-H2DCFDA. Over the years, we’ve seen firsthand how DCFH-DA’s cell permeability and robust fluorescence output stand apart in standard cell culture work. DHE stays more specific for superoxide, but DCFH-DA detects a broader range of peroxides, fitting users who need a global ROS measure instead of a narrow focus.
CM-H2DCFDA introduces added stability with its chloromethyl group, slightly reducing leakage from cells but at a cost: more expensive chemistry and trickier handling due to higher membrane binding. Our own comparative data highlight that while CM-H2DCFDA can give cleaner retention in some scenarios, many users stick with traditional DCFH-DA for routine screening because the signal remains strong, handling is straightforward, and costs stay lower at scale. For most labs, DCFH-DA offers the broadest compatibility with standard plate readers and imaging platforms. We’ve also responded to requests for low-dust, minimally hygroscopic forms after reports of batch issues with generic brands, which helps stop clumping and preserves usability as the probe warms to room temperature before opening.
One key difference between our DCFH-DA and lower-cost bulk imports lies in both packaging hygiene and real-time QC documentation. Labs have run into problems when third-party vials lack moisture-proof liners or are packed in generic plastic. Early batches from some suppliers produced crystalline cakes after several weeks, especially in humid climates. We shifted to using polypropylene vials with triple-layer protection, preventing moisture ingress and extending shelf life. Our ongoing shipping trials involve running vials through simulated temperature and humidity extremes, especially for international partners dealing with unpredictable transport timelines.
Our primary users span academic labs, preclinical contract research organizations, and pharmaceutical development groups. Most aim to quantify ROS changes under drug treatment, hypoxia, toxin exposure, or during basic signaling investigations. One collaboration with a leading cardiovascular team revealed how proper DCFH-DA quality delineated subtle differences between oxidant treatments that lower-grade probes masked with background noise. In another plant biology study, batch consistency meant toxicology studies repeated over months produced figures with genuine reproducibility, increasing confidence that observed changes reflected biological rather than chemical variation.
Discussions with core facility directors emphasized the value of robust shelf stability; turnover rates rarely keep pace with high-usage environments, making long-term probe reliability crucial. Traditional DCFH-DA decomposes over time, losing its acetate groups and raising the baseline fluorescence even before experiments begin. A big focus of our R&D effort involved fine-tuning the final crystallization and drying step, so that ongoing water absorption stays near negligible for more than 18 months in storage when unopened. After opening, we advise those storing vials under nitrogen or argon to limit water uptake. Our first-hand trials confirm that such care preserves reactivity for multi-month usage in routine settings.
It’s important to acknowledge that no ROS probe is perfect. Overoxidation, photobleaching, and interference from metal ions have each cropped up in the literature. Our staff chemists work alongside users to optimize probe concentration, timing, and light exposure, especially for sensitive live cell imaging. We found that supplying detailed handling guides, along with batch-specific data, reduces repeated troubleshooting and helps partners get to interpretable data faster.
Some power users have requested custom isotopic labeling for specialized mass spectrometry or advanced imaging methods. Meeting these advanced requests takes coordination and upfront transparency; customers need to know what’s feasible in weeks, not months. Experience in scale-up synthesis and a willingness to share our process details (to the extent not proprietary) underpins the trust many clients place in us, particularly when tackling novel applications in environmental monitoring or diagnostics. Recently, rising demand for greener synthesis and solvent minimization has also prompted us to evolve some of our steps, swapping out legacy solvents for more benign alternatives while retaining assay performance. This keeps us in step with the larger push for sustainable laboratory consumables, a trend we believe will continue to expand over the next several years.
Trust comes not from flashy claims but from years of consistent lot performance and transparent process refinement. We’ve developed our DCFH-DA to better serve researchers asking difficult questions about cellular health, oxidative signaling, and environmental stress response. Our staff includes several scientists who have run their own cell-based assays, so our improvements often spring from firsthand frustration with unreliable materials. Each shipment reflects a cycle of feedback, adjustment, and continuous validation. We dedicate as much effort to protecting stability in the supply chain as we do to perfecting the synthetic process itself. From package handling all the way to investigative troubleshooting for tough experiments, our staff stands behind the material — not just its technical specifications, but its clear track record in the hands of skilled users.
In the end, 2',7'-Dichlorodihydrofluorescein Diacetate represents more than a molecular probe; it’s a tool enabling real discovery, where robust manufacturing adds hidden value to every result. Our focus on real-world feedback, meticulous synthesis, and continual support reflects a commitment not just to selling chemicals, but to building practical solutions for the people driving biological innovation. The lessons learned through long-term partnerships help us keep pace with research trends while remaining grounded in the day-to-day needs of scientists, technicians, and product developers across the world.
Manufacturing DCFH-DA offers a unique window into the challenges and rewards of supplying critical reagents for diverse fields. Every batch we produce teaches us something new about user needs, supply chain intricacies, or application demands. In our shoes, every improvement — from humidity-resistant packaging to batch tracking — carries a ripple effect downstream, nowhere more crucial than in the hands of the experimentalist. With research on ROS and oxidative signaling gaining even greater prominence in medical, agricultural, and environmental studies, we stay committed to providing a probe that scientists can trust, not just for its nominal performance but for real, reproducible data. Open dialogue, a willingness to learn from end users, and constant process refinement keep our DCFH-DA not only relevant, but reliable in a world where the details truly matter.