HS Code |
865255 |
| Product Name | Undecafluorohexanoic Acid High Grade [Ion-Pair Reagent for LC-MS] |
| Chemical Formula | C6HF11O2 |
| Molecular Weight | 314.05 g/mol |
| Cas Number | 307-24-4 |
| Purity | ≥99% |
| Appearance | Colorless to pale yellow liquid |
| Boiling Point | 110-112°C (at 20 mmHg) |
| Melting Point | -1°C |
| Solubility | Soluble in methanol, water, and acetonitrile |
| Storage Temperature | 2-8°C |
| Application | Ion-pair reagent for LC-MS |
| Synonyms | Perfluorohexanoic acid, PFHxA |
| Density | 1.67 g/cm³ (25°C) |
| Pka | 1.8 |
| Hazard Class | Irritant |
As an accredited Undecafluorohexanoic Acid High Grade [Ion-Pair Reagent for LC-MS] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging is a 25g amber glass bottle, sealed, labeled with product and safety information for Undecafluorohexanoic Acid (High Grade). |
| Shipping | Undecafluorohexanoic Acid High Grade (Ion-Pair Reagent for LC-MS) is shipped in tightly sealed, chemical-resistant containers, compliant with hazardous material regulations. Packaging ensures stability and prevents leakage. Shipping is expedited, often under temperature-controlled conditions, and includes safety documentation (MSDS), in accordance with Sigma Aldrich, Merck, or TCI Chemical standards. |
| Storage | Undecafluorohexanoic Acid High Grade [Ion-Pair Reagent for LC-MS] should be stored in a tightly sealed container, in a cool, dry, well-ventilated area, and protected from light and moisture. Store at room temperature (15–25°C), away from incompatible substances such as strong bases and oxidizers. Always follow the manufacturer’s recommendations and local regulations for safe chemical storage. |
Competitive Undecafluorohexanoic Acid High Grade [Ion-Pair Reagent for LC-MS] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Undecafluorohexanoic acid high grade, tailored for advanced LC-MS workflows, stands as a key refinement delivered by chemists who not only produce but also rely on the material in rigorous day-to-day separations. Typically referenced by the abbreviation UFHA, this fluorous acid, with the molecular formula C6HF11O2, brings a clean profile and consistent volatility, attributes we know matter greatly in analytical work. Our production team, rooted in fluorine chemistry for decades, understands the scrutiny these details receive in every credible mass spectrometry lab. As manufacturers, we handle every synthesis and subsequent purification step with a focus on removing trace ionic or metallic impurities, which directly impact the sensitivity and repeatability analysts pursue.
With LC-MS, especially in pharmaceutical or environmental testing environments, the specification of the ion-pair reagent shapes baseline separation and ion suppression. Our high grade undecafluorohexanoic acid arrives with a purity exceeding 99.5% by GC, and we maintain recorded moisture levels below 0.05%. These figures did not stem from market reports—they’re the outcome of exhaustive runs through our fluorinated acid stills, followed with Karl Fischer testing and trace metal monitoring using ICP-MS. Chemists in our process lines push every refinement cycle to not only achieve but also verify these numbers. Colorimetric and NMR checks reinforce batch-to-batch reproducibility, marking the difference between manufactured product and bulk resold material.
A technical facility conducting trace-level pharmaceutical residue detection will understand the impact of LC-MS system cleanliness and reliable adduct formation. UFHA brings optimal ion-pairing performance in reversed-phase separations, providing a reliable acidic modifier that outperforms legacy fluorinated alkanoic acids in reducing peak tailing for amine-containing analytes. In our labs—mirroring those of major quality control and research facilities—the prepared 0.1–1 mM aqueous solution routinely delivers higher signal-to-noise ratios in positive and negative ion mode. Our procedural notes and feedback from end users reinforce this outcome, as lower background and sharper peaks cut down both runtime and costly instrument maintenance. We have seen system pressure remain stable and column performance extend over repeated injections thanks to the volatility profile of high-purity UFHA.
Direct involvement in both custom LC method development and high-throughput analyses has shown the value of reducing cross-contamination from ion-pair reagents. Many efforts in our manufacturing process address the headache that non-volatile residues and buffer precipitates cause in modern HPLC hardware; hence, we invested in zone-refined purification setups that keep residue formation at bay. This work saves end-users from baseline instability, signal drifting, or repeated column washing—a real cost, considering both solvent waste and downtime.
As chemists and process managers, we find that many ion-pair HPLC acids marketed globally carry organic, inorganic, or even polymeric contaminants. Over the years, different suppliers have sourced secondary reagents from resellers or impure fluorination streams, introducing interfering peaks and matrix effects in LC-MS. Our approach relies on vertical integration—selecting fluoroalkyl precursors ourselves and controlling each distillation cutoff. We never blend lots or over-dilute for volume. Instead, the focus remains: no unidentified peaks, no color-forming impurities, and control over isotopic consistency, since even a trace isotopic shift can muddy a mass spectrum. We see competitors patch these issues with additional downstream filters or polishes, but in our experience, starting with a pure, well-characterized stream returns better, more consistent product.
In application, laboratories switching to our high grade find fewer ghost peaks and a sharper response in mass accuracy calibration. The difference shows up in baseline clarity—even at single-digit ppb. Analysts often struggle with slow carryover and background shifts when using imported lots with unreported stabilizers or storage solvents. Our internal protocols ban such additions; while this may increase storage and transport demands on our part, we see long-term reliability trumping transient shelf-stability every time. The difference emerges in real-world data: API manufacturers shifting to our high grade have reported not only improved quantitation linearity across dynamic ranges, but also a reduction in ion suppression variability between matrices.
One persistent challenge in the supply of perfluorinated acid reagents involves trace-level leaching of cations, especially sodium and calcium, that disrupt electrospray performance. Monitoring and controlling these at microgram-per-kilogram levels requires more than off-the-shelf purification columns. We oversee cleaned glassware, PTFE-lined containers, and regular audits of packaging materials for the very reason that even an invisible contaminant causes trouble downstream. Our internal reference standards and comparison with NIST-certified materials confirm that our product consistently outpaces those processed with more generic equipment or less rigorous upstream QA practices.
Researchers, quality controllers, and application specialists seeking to extend detection limits often overlook the effect of their ion-pair reagent. In reality, signal-to-noise, baseline flatness, and even injection reproducibility have roots in the purities achieved by the primary manufacturer. Our team has partnered with academic labs and pharmaceutical QA groups to co-develop challenging separation protocols, often encountering roadblocks caused not by columns or equipment, but by the additive. Ongoing trials with method developers show that by simply switching from commercial to high grade UFHA, background begins to clear and peak shape improves—without extensive revalidation.
The picture in regulated environments, such as therapeutic drug monitoring or pesticide residue analysis, grows even sharper: every reagent lot passes not only our own QC but also routine third-party validation, a practice we welcome after seeing how deviations in purity explain otherwise inexplicable shifts in system suitability. Our feedback loop is short; customer observations about drift, split peaks, or batch-to-batch variation travel directly to our production process. As a result, we adopt process modifications swiftly, whether by breaking down feedstock material for extra purification cycles or upgrading trace analysis instrumentation.
Across years of scale-up projects, our staff has fielded calls about buffer cloudiness, column seizing, and trace spectrometric anomalies. These issues, often traced to a reagent’s background load, solvent compatibility, or breakdown during pump idle time, have pushed us to design our high grade UFHA for rapid mobile phase solubility and full volatility, cutting down instrument downtime. Reagent composition aligns seamlessly with both methanol and acetonitrile phases, with minimal outgassing or precipitation—a quality benefiting both direct-injection and gradient elution protocols.
Some LC-MS users working with biological matrices, such as plasma or urine, dread matrix suppression from surfactant-like impurities in lesser reagents. In extensive inter-lab validation studies involving protein-rich samples, our acid’s high fluorination and limited surfactancy ensure minimal interference, preserving system pressure and chromatography even during extended runs. We understand the pain of mid-assay signal drop-off or abrupt mobile phase contamination, which is why every drum, bottle, and ampoule is tested and sealed in cleanrooms, using oxygen- and moisture-free headspaces. No random lot-blending, no stopgap stabilizers.
The widespread focus on per- and polyfluoroalkyl substances (PFAS) forces manufacturers to not only deliver purity, but also demonstrate traceability for every reagent batch. Within our facilities, cradle-to-gate documentation anchors the origin of both carbon source and fluorinating agents. Regulatory teams require full disclosure nowadays, and our compliance records include both batch synthesis logs and all process audits, available for inspection. Our products comply with both current RoHS and REACH standards where mandated, and we provide customer-facing declarations unlocking smooth regulatory submissions. We constantly review analytical traces for environmental carryover and confirm product shelf stability without tacky storage solvents or colored stabilizers that might interfere with downstream analysis or raise compliance flags. As a direct producer, feedback from regulated industry consortia and working groups continues to shape how we approach both product development and quality assurance.
Having a direct hand in manufacturing means seeing the full circle, from raw precursor design to after-sales user feedback. Each time a shipment yields a particularly successful user report—fewer instrument alarms, a longer-lived column, or more reliable automated sample injection—we evaluate the possibility for system-wide process upgrades. Our scale-up chemists and technical support teams collaborate continuously, looking for any signal of subtle impurity introduction or handling drift that might impact next-generation mass spectrometric methods.
The ongoing dialogue with reference labs offers sharp insight; many users recount scenarios where unexpected peak drift or heightened limits of detection pointed squarely at reagent inconsistencies from other suppliers. By prepping our own application notes and supporting custom gradient development, our technical team fosters trust with users. We treat every inquiry as direct feedback, sometimes retracing our reactions as far back as individual purification columns or solvent sources, to guarantee consistent experience from lot to lot.
Our background in fluorous chemistry predates many recent adopters entering the ion-pairing landscape. This depth brought us lessons in handling ultra-low-impurity perfluorinated acids, including the necessity of gas-tight transfer systems and nonmetallic reaction vessels to prevent contamination. We don’t take shortcuts; all distillation endpoints are hand-verified and tested against internal release specs using our own calibrants. This approach counters problems typical in the market, where undifferentiated blending or overextending purification columns leads to weaker product lots, as confirmed by side-by-side third-party analyses.
Batch control stretches from raw material input to the point each bottle leaves the warehouse. If a run flags above our target specs—not simply a documentary violation but real-world, measurable signal interference—material faces rework, not shipment. Customer audits, both in-person and by remote witness, have commended this approach, and several recurring clients base their vendor choice on firsthand observation of our retention sampling and quality logging. Direct manufacturing means no trading-off between profit margin and reliability, and our team, from synthetic chemists to batch packers, takes full ownership of the result.
A European certified reference lab, shifting from a major U.S. ion-pair supplier, flagged ongoing background interference near the lower mass range in both targeted and untargeted workflows. A trial of our high grade UFHA closed out the interference and measurably tightened peak width across analytes, saving both instrument hours and re-test cycles. In another case, a pharmaceutical client validated high-throughput impurity profiling of drug substances, seeing improved mass response upon adopting our lot over a comparable competitor batch. Instead of chasing after instrument service or method redesign, the underlying reagent quality traced as the root fix.
A food safety laboratory working with an earlier-generation ion-pairing reagent failed periodic system suitability due to shifting retention times, traced by their team to changes in a bulk supplier’s product. A direct switch to our higher grade, after initial parallel testing, restored not only baseline shape but also day-to-day reproducibility across seasonal raw material changes. In these and other cases, the conversation revolved not around abstract quality metrics but in quantifiable method stability and confidence in analytical data.
The evolution of LC-MS, especially as modes transition toward lower and lower detection thresholds or more complex sample matrices, raises the bar for every piece of the workflow stack—including the ion-pairing acid. Our ongoing R&D program draws on collaborations with instrument manufacturers and method labs to support the push for shorter, sharper runs and greener solvent systems. Adaptations in reagent packaging—smaller volume units, inert-lined closures, and single-use ampoules—grew from direct feedback and hands-on observation of issues users face in high-throughput environments.
Instrument specialists routinely ask us about compatibility with high-pressure or microflow LC systems. We design our product to remain inert and measurable through all current and emerging hardware formats, with support for both direct ESI and APCI source configurations. Internal stress-testing covers repeated vial punctures, extended auto-sampler stints, and freeze-thaw cycles, pinpointing how real-world handling impacts downstream results. Greater complexity in sample prep, such as post-column derivatization or automation, only reinforces why consistent and robust manufacture at the reagent stage can’t be substituted for by after-the-fact filtration.
Being a manufacturer, not a trader, stands as the difference-maker in how we approach both product and customer. Challenges stemming from handling, storage, or method validation come directly to our door. As a result, improvements in production cycle, staff training, or QA all feed into the next lot, rather than lagging downstream by years or buried in contractual back-and-forth. If an improvement in impurity removal, new packaging standard, or upgraded process control appears justified by field data, we adopt fast, bypassing layers of middlemen.
We continually refine our processes based on results, not just specifications. The acid’s high grade means more than just a higher purity figure—a measured impact hits every chromatography lab that works at the limits of detection. Fewer disruptions, clearer peaks, and more uptime for instruments represent outcomes we directly track. As manufacturers directly invested in this chemistry, we offer not only a product but also a commitment: the lot you buy next year will reflect the hard-won lessons and tight control delivered by chemists who know LC-MS not just from a catalog, but from daily reality.
Delivering high grade undecafluorohexanoic acid isn’t simply about riding market trends or chasing purity digits. It’s a daily exercise in attention to detail, handling risk, and incorporating user feedback from people at the bench, not just buyers or procurement. Method developers, QA analysts, and process integrators who choose direct-from-manufacturer reagents like this one participate in a loop of continuous product improvement—a cycle missing in much of the fast-moving, commodity-driven reagent business.
Our facility’s reputation and UFHA’s impact are only as strong as the chromatography runs and data sets produced by the chemists and technicians relying on that bottle. Every bottle carries the assurance that it has been produced, tested, and shipped by a team owning the outcome. Trace-free, batch-pure, and built on verified process steps, our undecafluorohexanoic acid high grade serves as a foundation for modern LC-MS ion-pairing, with reliability and confidence that only an accountable, hands-on manufacturer can guarantee.