|
HS Code |
912523 |
| Product Name | Tris(1,10-phenanthroline)cobalt(II) Bis(hexafluorophosphate) |
| Chemical Formula | [Co(phen)3](PF6)2 |
| Molar Mass | 1003.59 g/mol |
| Appearance | Dark purple crystalline solid |
| Solubility In Water | Slightly soluble |
| Melting Point | Decomposes above 200°C |
| Coordination Geometry | Octahedral |
| Oxidation State Of Cobalt | +2 |
| Cas Number | 14604-07-2 |
| Magnetic Property | Paramagnetic |
| Main Application | Analytical chemistry, coordination chemistry research |
As an accredited Tris(1,10-phenanthroline)cobalt(II) Bis(hexafluorophosphate) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | A 1-gram amber glass bottle with a screw cap, labeled with Sigma Aldrich branding, chemical name, grade, and safety information. |
| Shipping | Tris(1,10-phenanthroline)cobalt(II) bis(hexafluorophosphate) is shipped in tightly sealed, chemical-resistant containers. Packaging complies with international regulations for hazardous materials (Class 9: Miscellaneous). Shipping includes appropriate labeling for chemical safety, often with accompanying Safety Data Sheet (SDS). Temperature and light protection may be required; carrier selection follows guidelines for laboratory-grade chemicals. |
| Storage | **Tris(1,10-phenanthroline)cobalt(II) Bis(hexafluorophosphate)** should be stored in a tightly sealed container, protected from moisture and light, in a cool, dry, and well-ventilated area. Avoid exposure to sources of ignition, strong acids, and bases. Store at ambient temperature unless otherwise noted by the supplier, and keep away from incompatible materials. Always follow the manufacturer's recommendations. |
Competitive Tris(1,10-phenanthroline)cobalt(II) Bis(hexafluorophosphate) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
As a producer with years behind the reactor and a commitment to stringent quality standards, I want to spotlight our tris(1,10-phenanthroline)cobalt(II) bis(hexafluorophosphate), well known in the chemistry world as [Co(phen)3](PF6)2. Every batch that leaves our doors comes direct from our own synthesis and purification lines. We do every step ourselves, starting from raw chemicals all the way to the final air-tight packaging. We know how vital it is for customers—whether in a university lab or an advanced materials facility—to receive exactly the product they asked for, in the purity and lot size they count on.
This compound stands out for specialists working in molecular electronics, photochemistry, and analytical chemistry. What makes it so sought-after? Our experience says it’s all about its consistent redox properties and the robustness it brings to research setups. With its iconic deep red color, [Co(phen)3](PF6)2 serves as a benchmark in electrochemical analysis, a sensitizer in photon-driven systems, and a vital complex in catalysis studies. People put their equipment and reputation on the line running sensitive tests, and we've learned over decades that even trace levels of impurities can derail an experiment. That's why our facility has leaned into analytical tools like HPLC and ion chromatography that catch every signal of contamination or unwanted byproducts.
Our tris(1,10-phenanthroline)cobalt(II) bis(hexafluorophosphate) offers a purity of at least 98 percent, with moisture content held below 0.2 percent, as confirmed by independent labs as well as our own QC department. Crystalline batches show a characteristic intense magenta or deep red hue, a reliable indicator of correct stoichiometry and ligand environment. We provide standard packaging in 1-gram, 5-gram, and 25-gram amber glass bottles to protect against both light and air. Bulk requests are filled using nitrogen-flushed bags sealed inside multilayer aluminum to prevent oxidation or hydrolysis between leaving our site and docking at yours.
Cobalt-phenanthroline complexes like ours differ in several key ways from the more common iron, copper, or ruthenium analogues. For one, the cobalt(II) center sits in a pseudo-octahedral geometry, but the PF6– counterions deliver much greater lattice stability than halides or perchlorates. We have tested their impact directly: hexafluorophosphate reduces unwanted ionic exchanges, so your solutions stay cleaner across a wider pH and longer storage windows. In high-voltage electrochemical setups, this complex handles charge cycling better than iron-based equivalents, because the coordination shell holds together through far more cycles before signs of ligand dissociation appear.
The 1,10-phenanthroline ligand itself brings rigidity and planarity, which we have found crucial for researchers exploring surface attachment, polymer hybrid systems, or luminescent probes. Unlike bipyridine or terpyridine, phenanthroline chelates control the microenvironment in thin film applications, and their stacking behavior lends itself to ordered materials. If the application calls for visible-light absorption or photoinduced electron transfer, this cobalt complex earns its place over ruthenium and copper complexes for its resilience under high-intensity lamps or pulsed laser exposure.
We learned early that not all customers want precisely the same product. One organic electronics group requested a higher-density crystalline form to avoid caking in automated weighing feeders, so we optimized our drying cycle over several months and now offer both standard and high-density crystal cuts. In academic settings, hydrogen bonding and solubility control come up constantly. That’s why, after prolonged feedback from working chemists, we now routinely publish expanded solubility tables for several organic solvents—not just water or acetonitrile, but DMF, DMSO, and even nonpolar mixers. Every time someone called with a failed attempt to dissolve another vendor’s product, we asked for their protocol, then checked ours against it. Process tuning worked: those complaints dropped by over half in a year.
Sourcing high-purity raw phenanthroline posed its own challenges. Early on, third-party suppliers provided inconsistent lots, which threw off yields and purity. So we built up our own intermediate synthesis lines, so every molecule of ligand matches precise criteria before touching cobalt. From this, we cut scrap by twelve percent and drove the overall cost per gram down for our regular customers. While cobalt costs do fluctuate globally, our purchasing contracts allow us to lock in prices several months in advance, shielding clients from surprise price jumps.
Labs and pilot plants running critical processes cannot afford batch-to-batch variation. We understand this risk firsthand. In specialty organometallic chemistry and advanced materials research, slight shifts in side-product profile or trace ion content can derail an entire project. This is where our in-house analytics deliver real value. Every time a customer, especially electrochemical teams, flagged instability or signal noise from other suppliers’ complexes, we asked for spent electrolyte samples, ran our own comparisons, and traced the issue back to inconsistent purification or low-quality counterion sources. With our vertical integration, we check every lot of PF6– for metal and organic contaminants before complexation—even after regulatory changes forced many upstream providers to shift methods.
These process refinements mean calibration curves come out sharper, spectra shift less with time, and surface-anchored films show reproducible color and conductivity. For those using cobalt(II)-phenanthroline in photonics or biosensor arrays, these qualities spare days of rework and the cost of wasted substrates.
We always listen closely to end users, and feedback loops have led to concrete changes in our methodology. Catalysis researchers often tell us that trace ferromagnetic impurities lead to edge-case reactivity or loss of selectivity, especially in sensitive hydrogenation or cross-coupling assays. To address this, we doubled the number of purification cycles using both column chromatography and successive recrystallizations. As a result, trace iron content now routinely falls below 5 ppm, well below limits recorded in most literature syntheses. This directly translates into cleaner NMR, sharper CV signals, and reliability in kinetic runs that depend on clean baseline measurements.
Solubility profiles in organic media became a frequent pain point for teams running high-throughput screening. Chemists working with microscale arrays need every well to dissolve rapidly without ultrasonication or extensive agitation. Utilizing improved drying procedures coupled with controlled humidity storage, our batches avoid the slow-caking and partial hydration seen with imported or loosely packed material. This solved many old headaches for screening operations.
We offer two primary models from our factory lines: standard-coordination tris(1,10-phenanthroline)cobalt(II) bis(hexafluorophosphate) and a functionalized variant bearing methyl groups at the 2,9-positions of each phenanthroline ring. The functionalized version caters to chemists seeking altered electronic structure or those wishing to explore substituted ligand environments. It shifts the absorption maxima, delivers new redox features, and suits applications from dye-sensitized solar to molecular wires. Feedback from solar cell researchers led us to perfect the scale-up of the methylated ligand, keeping costs within reason, so pilot lines could analyze multiple batches side-by-side without budget overrun.
We only release new product variants after direct stress testing in collaborative research runs. This means we ship test lots for direct performance feedback by users—the only way to guarantee our process delivers not just by the book but by real-world criteria. Scale is not an afterthought, either: kilo-scale runs move from bench through pilot synthesis using mirrored conditions, so the product behaves the same at any order size.
Our approach to manufacturing stems from the experience that every gram counts and every analysis tells a story. Our team documents the full chain of custody for each lot, from incoming metal salts to packed and labeled product. We maintain traceability by keeping matched documentation, recorded instrument logs, and reference samples archived for at least five years. Purchasers and auditors are welcome to review matched lot data, and several long-term university partners request digital spectra with each shipment. Even for urgent or bespoke runs, traceability stays locked at each stage, never skipped.
We run a full complement of analytical checks for each outgoing lot, including IR, NMR (where applicable), mass spectrometry, microanalysis for C/H/N content, and x-ray diffraction for crystal phase confirmation. Our in-house analysts remain accessible to researchers with technical questions who want to compare our reference data with their own measurements. This open line bolsters confidence in cross-lab reproducibility, especially in collaborative or multi-center studies. We know chasing down inconsistencies wastes invaluable lab time; our consistent feedback from clients tells us those calls have dropped sharply in recent years as our QC processes improved.
Over the years, many new manufacturers and resellers have entered the market for organometallic complexes. We regularly benchmark our products directly against competitor materials, both imported and domestic. Several common pain points consistently stand out: high water content in cheaper material from offshore plants; batch-to-batch color shifts hinting at variable ligand-to-metal ratios; and uncontrolled byproducts hinting at cut corners in drying or filtration.
Our own output avoids these missteps by running purification deeper and controlling product drying right after crystallization and filtration. Each finished lot starts off still-warm from our dryers, then gets transferred into sealed, nitrogen-purged containers designed for long shelf-life. Real-world evidence backs this up: our regular customers report stable batches after a year or more in storage, with minimal change in analytical signals or solubility. Labs running duplicate experiments with several vendors' products have confirmed our material brings sharper and more reproducible results.
The cost per gram may look higher at first, but when evaluating total project cost—that is, rework, remakes, lost samples, and method validation headaches—the balance tips quickly in favor of reliable sourcing. Large institutional buyers and consortia tell us our products help hit their reproducibility and reporting targets.
Our cobalt complexes use responsible sourcing for raw metal salts. Strict handling prevents waste and accidental exposure. We manage all cleaning and wash water using advanced filtration before discharge, and ligand preparation avoids persistent organic contaminants. Staff train yearly on hazardous material handling and emergency protocols. We hold regular audits for safety and environmental compliance, welcoming regulatory checks without hesitation.
Safe packaging isn’t limited to regulatory checklists. We designed our jars and boxes specifically for users wearing gloves, or working in gloveboxes, so seals open smoothly and minimize static build-up. This way, less risk of dropping expensive or hazardous material, and less risk of spills or loss for users with tight inventories. All shipping materials meet international standards for chemical transport.
Most of our shipments go to university labs, specialty manufacturers in electronic inks and dyes, and emerging clean energy research centers. Others make their way to contract research organizations running client-driven synthesis and method development. In luminescent probe development, our material serves as a backbone for new analytical reagents and sensor films. Electrochemistry groups use it to calibrate and develop new batteries, proton exchange membranes, and redox flow cells.
The difference, according to research partners, comes through when comparing kinetic traces, reproducibility of half-cell voltages, or longer stability of thin film properties. Many of these advances trace directly to the care taken on the manufacturer’s bench, blending the best of classical wet chemistry with laser-focused modern analytics.
Our drive continues to keep tris(1,10-phenanthroline)cobalt(II) bis(hexafluorophosphate) at the cutting-edge of research and specialty manufacturing. Experience shows that only a steadfast, evidence-driven approach keeps both cost and quality on target over the long haul. The more closely we collaborate with chemists at the bench, the more we learn—and adapt. If a challenge comes up, or new applications arise, we welcome direct input, because this is how our product—and your science—moves forward.