|
HS Code |
371714 |
| Product Name | Trifluoroacetic Acid (ca. 0.5mol/L in Water) [Ion-Pair Reagent for LC-MS] |
| Chemical Formula | CF3COOH |
| Concentration | 0.5 mol/L |
| Solvent | Water |
| Molecular Weight | 114.02 g/mol |
| Appearance | Clear, colorless liquid |
| Boiling Point | 72.4 °C (pure TFA) |
| Density | 1.489 g/mL (pure TFA, 25°C) |
| Cas Number | 76-05-1 |
| Ph | 1-2 (for 0.5 mol/L solution) |
| Storage Temperature | 2-8°C |
| Grade | LC-MS |
| Application | Ion-pair reagent for liquid chromatography-mass spectrometry (LC-MS) |
| Hazard Statements | Corrosive, causes severe skin burns and eye damage |
| Expiration | Refer to manufacturer label |
As an accredited Trifluoroacetic Acid (ca. 0.5mol/L in Water) [Ion-Pair Reagent for LC-MS] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Trifluoroacetic Acid (0.5 mol/L in Water) is supplied in 500 mL amber glass bottles, featuring secure screw caps and safety labeling. |
| Shipping | Trifluoroacetic Acid (ca. 0.5mol/L in Water) is shipped in a secure, leak-proof container suitable for corrosive liquids. The package complies with international hazardous materials regulations, ensuring safe transport by air or ground. Proper labeling, Material Safety Data Sheet (MSDS), and temperature control are included as per chemical and LC-MS reagent standards. |
| Storage | Trifluoroacetic Acid (ca. 0.5 mol/L in Water) should be stored in a tightly sealed, corrosion-resistant container, clearly labeled, in a well-ventilated, cool, and dry area away from incompatible substances such as bases or reactive metals. Protect from direct sunlight and moisture. Store at room temperature, following laboratory and safety protocols, and keep separate from food and drinking water areas. |
Competitive Trifluoroacetic Acid (ca. 0.5mol/L in Water) [Ion-Pair Reagent for LC-MS] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
In years of manufacturing and supplying chemicals to both academic and industrial labs, certain products come through as true workhorses in everyday separations. Trifluoroacetic acid, or TFA, especially at a concentration of about 0.5mol/L in water, plays a key role for anyone working with liquid chromatography-mass spectrometry. Some products gain a reputation for reliability, and TFA of this grade sits in that group, not because of marketing, but because users see the results firsthand, every week, in real samples and method development.
Analytical chemists using LC-MS often face challenges with peak shapes, signal suppression, and consistency. From experience on the manufacturing floor, we understand that the key factors affecting TFA performance are concentration accuracy, purity, stability, and compatibility with high-sensitivity detectors. Making TFA solution at 0.5mol/L in water takes more than dissolving and bottling. Every batch runs through stringent controls, not only to meet the declared concentration, but also to minimize trace metal and particulate contamination, since impurities can mean trouble during an LC-MS run — sometimes showing up as ghost peaks, signal drift, or inconsistent quantification.
Repeated customer feedback points to one central requirement: every bottle should perform the same way as the last. Even a subtle fluctuation in the acid concentration disrupts reproducibility, especially in regulated or routine environments. Many years ago, we noticed that some generic TFA solutions on the market lacked this batch-to-batch reliability, so we focused on controlling every step — from sourcing high-purity feedstock to refining filtration processes, and tracking lot-specific analytical results for every shipment.
A fresh bottle opens, and no one wants to worry about guessing at true molarity. Addressing this, our production employs precision gravimetric approaches, advanced titration, and cross-checks with conductivity. It’s these quality controls that make the TFA solution suitable even for labs requiring trace-level detection, where outliers are not just an annoyance but a serious threat to data integrity. Such attention to specification also helps reduce downtime and troubleshooting. People know exactly what to expect from each bottle because repeatability is built in from the start.
TFA’s popularity runs decades deep in both analytical and preparative liquid chromatography. Mass spectrometrists, peptide chemists, and biochemists alike favor TFA for its ability to help sharpen peak shapes, resolve co-eluting components, and suppress undesirable secondary interactions between analytes and silica-based stationary phases. Unlike many other acids, TFA demonstrates strong ion-pairing properties without provoking excessive baseline noise or rapid ionization suppression at moderate usage levels. In the context of peptide mapping or pharmaceutical impurity profiling, these properties yield data that passes scrutiny — a must in regulated environments.
The demands of modern LC-MS push for both high sensitivity and selectivity, so the choice of ion-pairing reagent narrows quickly. TFA balances strong volatility, efficient desolvation, and persistent ion-pair effect. Some alternative acids struggle in one or more of these aspects. For example, formic acid and acetic acid often deliver weaker ion-pairing, resulting in broader peaks or lower retentivity for polar analytes, while more exotic reagents may interfere with ESI source cleanliness or require complicated waste handling.
Production experience has shown that concentrations near 0.5mol/L offer ideal handling and shelf stability, while still retaining effectiveness as a concentrated stock solution. This strength dilutes cleanly to the working concentrations typically used for HPLC or LC-MS mobile phases, which usually range from 0.01% to 0.1% v/v final TFA. Lower concentration stocks lead to greater dilution errors and risk of contamination through repeated bottle opening. Meanwhile, higher concentrations push safety and storage challenges, especially when using plasticware or when shipping outside temperature-controlled routes.
At approximately 0.5mol/L, the solution is manageable, poses fewer evaporation losses during brief openings, and enables direct, volumetric measurements that fit existing SOPs in most labs. It also meets the need for a ready-to-use intermediate, whether for automated liquid handlers or for quick bench-scale method adjustments. The synergy of handling safety and performance has come from hearing directly from customers about their workflows and what slows them down. These conversations encouraged us to maintain rigorous control over every parameter affecting the reagent from production through distribution.
Some users new to LC-MS believe any strong acid might substitute for TFA, but the downstream impact of purity and formulation quickly becomes evident. In our facility, technicians screen for organic and inorganic contaminants that might appear harmless in initial chromatography, yet can alter retention or ion generation as ion sources grow ‘dirty’ over time. Filtration must go beyond visible particles. High-resolution analysis picks up background ions, surfactants, or unexpected leachables. Every production run includes spectral and titrimetric confirmation, and the filtration regimen addresses both submicron particulates and any absorption-derived leachate from transfer gear.
Consistent LC-MS signals rely on more than molecular concentration. We’ve learned that critical impurities, even at sub-ppm levels, can shift the baseline or mute signals for certain classes of molecules, especially in negative ion mode or with delicate detection settings. That’s why every instrument-facing product we release undergoes additional runs in real-world test methods, not only in sterile bench-top environments, but also as mobile phase supplements in actual peptide separations or metabolite detection scenarios.
Some labs historically handled neat, pure TFA, preparing aqueous solutions as needed. Over the years, requests for ready-to-use solutions have replaced raw acid orders. There are several practical reasons for this shift: safety, time, and reproducibility. Neat TFA is strongly fuming, corrosive, and evaporates readily, causing inhalation and splash hazards, especially in high-volume environments or automated settings. Preparing dilute stock solutions under a hood is feasible, but repetitive preparation increases the potential for operator error and environmental exposure.
By supplying TFA pre-diluted at 0.5mol/L, the risks are minimized. Most users appreciate not only the lower vapor hazard, but also that each lot comes from carefully blended production, ensuring minimal variability and less exposure to volatile emissions. Technicians, researchers, and QA staff benefit from the predictability, especially for qualifying LC-MS methods in support of regulated submissions or long-term stability studies.
Analytical teams sometimes debate whether to use TFA, formic acid, or acetic acid for ion-pair enhancement in LC-MS. Each brings different profiles. Formic acid works well for sensitivity in positive-mode ESI, but it can lack the strong ion-pairing needed to sharpen peaks for certain peptides and hydrophilic compounds. Acetic acid suits some acidic mobile phases, but tends to deliver weak retention for strongly polar analytes.
TFA offers a unique edge because its trifluoro group creates a more hydrophobic and bulkier counterion, strengthening interaction with positive charges on analyte amines. This property levels out peak symmetry and narrows broad elution envelopes. While TFA sometimes reduces MS sensitivity compared to formic acid due to partial suppression of ionization, many labs continue using it because the improved chromatography outweighs the signal trade-off, especially in discovery-phase and characterization runs.
Furthermore, TFA’s volatility ensures no non-volatile background accumulates in mass spectrometer sources, a risk associated with the use of some alkyl sulfonates or phosphate-containing reagents. From production-side monitoring, our TFA blends achieve low UV baseline noise, so LC with UV detection also benefits.
LC-MS applications run across many fields, but routine users include pharmaceutical quality control teams checking for process impurities, biotech labs developing new biologics, and academic centers profiling peptides or metabolites. TFA in 0.5mol/L aqueous solution fits seamlessly into validated methods and development projects. It dissolves quickly into commonly used solvents. Whether the mobile phase needs low-pH conditioning, sharper peak shapes for small and large molecules, or regular system cleaning, this format matches typical workflows.
In peptide mapping, TFA keeps hydrophilic fragments eluting more tightly, supporting sequence analysis in complex digests. In impurity profiling of small-molecule drugs, it stabilizes retention without leaving stubborn background in detectors. Even in food safety and environmental analysis, trace-level detection of contaminants depends on mobile phases remaining clear of noise and interferences—an outcome closely tied to the quality of the ion-pairing agent.
Over time, challenges arise in maintaining supply consistency across regions and regulatory boundaries. We often hear about difficulties from labs that switched sources and saw minor but significant chromatographic shifts or unexplained dropouts in their spectra. To address this, we maintain rigorous controls on input materials, invest in staff training, and implement layered quality verification. Each production cycle includes stability checks, long-term storage tests, and comparison with reference standards.
Feedback from researchers also drives continuous process improvement. Sometimes, a newly acquired instrument or revised protocol exposes trace background that a legacy product never produced. These lessons shape stricter lot-release criteria: not just purity, but solvent residue, UV absorbance, and baseline clarity under the most sensitive LC-MS settings.
As use of LC-MS grows, so too does awareness of laboratory waste handling. TFA, even at lower concentrations, needs careful handling before disposal, as regulated by local authorities. Our production includes detailed documentation supporting downstream users in meeting their compliance obligations. We encourage operating procedures that minimize waste and encourage batchwise preparation of working mobile phases to reduce overage and expired solution.
We back efforts to improve closed-loop recycling in large labs, sharing best practices on safe collection and neutralization of acidified mobile phases. Our manufacturing processes aim to reduce direct waste by optimizing batch sizes and refill packaging, so less product sits unused on laboratory shelves. This approach supports both economic and environmental goals.
In the dynamic world of analytical chemistry, trust in reagents comes from more than a label — it’s the result of day-in, day-out experience. We see the careful choice of mobile phase additives as a core part of method reliability. By focusing on well-controlled 0.5mol/L TFA solutions, we offer laboratories a balance of safety, convenience, and insight-driven quality. Our direct production allows close feedback loops and faster response to both emerging needs and occasional issues.
Every bottle begins with raw materials sourced from trusted suppliers, passes through multiple stages of purification and blending, and finishes with both in-house and third-party validation. This process is visible to end-users through transparent batch certificates and responsive technical support. Years of partnership with demanding analytical labs shaped our company ethos: consistency, open feedback, and an ongoing drive to refine products as technologies and regulations evolve.
Working directly with the end-user, without mediators or relabelers, gives us a unique view into real challenges. We hear from analysts troubleshooting anomalous background, from technicians developing new mobile phase blends, and from compliance teams preparing regulatory dossiers. This flow of information drives continuous improvements — not just in the bottle, but in the practical reality of integrating TFA solutions into everyday lab practice. Every technical inquiry is an opportunity to refine production or documentation for the next batch.
When failures or anomalies happen in chromatography, the cause can be elusive. At the manufacturing level, we keep detailed records of raw material lots and process steps. This traceability aids in troubleshooting, and means issues can be addressed before they reach critical levels in customer labs. Over the years, this system has prevented countless hours of wasted analysis, sample reruns, and the hard-to-quantify frustration born from unstable or inconsistent reagents.
Liquid chromatography and mass spectrometry advance constantly. As detection limits drop and instrument sensitivity rises, the pressure grows to develop ever purer, more stable reagents that don’t add their own signal to the mix. We invest in process updates, new contaminant analytical capabilities, and downstream testing as these benchmarks change. Instead of simply keeping pace, the goal is to anticipate the needs of next-generation users — those who will ask for even lower background, easier automation integration, and more robust regulatory documentation.
Requests for custom packaging, ready-to-use blends, and more environmentally sustainable alternatives are rising year over year. We share knowledge with our partners about the safe handling, storage, and eventual disposal of TFA solutions — not just as part of compliance, but out of a responsibility for the larger ecosystem of laboratory practice. The lessons taken from decades in the industry ensure our TFA solutions evolve alongside analytical technology, not behind it.
Consistency and reliability save time, money, and stress across the life cycle of an analytical project. Each 0.5mol/L TFA solution reflects a commitment to supporting results that analysts can trust, whether in the search for new drugs, the monitoring of critical process steps, or the daily challenge of keeping instruments running cleanly. The demand for clear, reproducible data sets the bar high for every ingredient in an LC-MS workflow, and as a manufacturer deeply engaged with our customers, we accept and embrace that challenge.
Placing chemical manufacturing expertise at the service of the analytical community means more than providing high-purity reagents. It means listening, learning, and adapting, every time new requirements or difficulties arise. We continue refining our Trifluoroacetic acid solution — not just as a reagent, but as a tool honed to the real-world needs of working chemists, and a reliable partner to those for whom method reliability is not a luxury, but a necessity.