HS Code |
983369 |
| Product Name | Triethylammonium Acetate (2.0 mol/L in Water) [for HPLC] |
| Chemical Formula | C8H19NO2 |
| Concentration | 2.0 mol/L |
| Solvent | Water |
| Appearance | Clear, colorless to slightly yellow solution |
| Molecular Weight | 161.25 g/mol |
| Ph | Approximately 7.0-8.0 |
| Density | Approximately 0.99-1.05 g/mL |
| Storage Temperature | Room temperature (15-25°C) |
| Application | HPLC (High Performance Liquid Chromatography) buffer |
| Odor | Slight amine odor |
As an accredited Triethylammonium Acetate (2.0mol/L in Water) [for HPLC] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 500 mL clear glass bottle with secure screw cap, labeled with product details, Sigma-Aldrich branding, and safety information for laboratory use. |
| Shipping | Triethylammonium Acetate (2.0mol/L in Water) [for HPLC] is shipped in securely sealed, chemical-resistant containers to prevent leakage or contamination. Packaging meets regulatory standards for laboratory reagents. Delivery is typically via ground or air, with temperature control if required. Accompanied by a safety data sheet (SDS), it complies with chemical transport regulations. |
| Storage | Triethylammonium Acetate (2.0 mol/L in water) [for HPLC], supplied by Sigma Aldrich, Merck, or TCI, should be stored in a tightly sealed container at room temperature (15-25°C), away from direct sunlight and incompatible substances. Store in a well-ventilated, dry area designated for chemicals. Prevent contamination; avoid freezing. Always follow the manufacturer's specific storage recommendations and keep out of reach of unauthorized personnel. |
Competitive Triethylammonium Acetate (2.0mol/L in Water) [for HPLC] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Triethylammonium Acetate, at a concentration of 2.0 mol/L in water, stands out as a reliable buffer solution for high-performance liquid chromatography. Our daily work in buffer manufacturing puts us face-to-face with a sweeping spectrum of analytical chemists, every one of them striving to pull reproducible results from complex sample matrices. Through years of filling bottles and running our own QC, we’ve learned the needs that come from the bench itself—how even minor fluctuations in pH control or background purity can derail a sequence. This product responds directly to those everyday realities.
We manufacture this buffer with HPLC practitioners in mind, aiming for stability and predictability in preparative and analytical separations. Over years, we’ve learned that commercial phosphate and acetate buffers can differ considerably. Triethylammonium Acetate (TEAA) rises to the challenge especially in ion-pair chromatography and peptide mapping. By adjusting the pH with triethylamine, the solution maintains a pH near neutrality, buffering against the changes that typically show up with conventional acetic acid-sodium acetate systems. Chemists often prefer TEAA for its volatility; unlike inorganic buffers, TEAA doesn’t persist in columns or mass spectrometers. Instead, it acts as a friend to the instrument, leaving behind almost no stubborn residue.
A 2.0 mol/L concentration offers a robust buffer capacity. Across labs we supply, customers tell us that trimming the time spent mixing—plus lowering the risk of pipetting or weighing errors—ranks high on their wish list. By delivering a solution that’s ready to use, we let technicians focus on injection sequences and data review, not beakers and weigh boats. Several chromatographers at large pharmaceutical houses shared that scale-up from microgram analytical runs to semi-preparative loading is less stressful when buffers show reliable lot-to-lot composition.
Our team closely monitors ionic strength and free amine content because inconsistent purity causes more column-to-column variation than many chemists realize. In lower-grade buffers, residual aldehydes or metal ions can prompt unexpected peak tailing or background drift. We have seen that even a ppm or two of residual organics, which show up when suppliers cut corners or use industrial-grade starting materials, can destroy sensitivity for some protein or nucleic acid assays. Our process employs high-purity water and high-resistivity stock triethylamine and glacial acetic acid. We rely on hydrogen peroxide-scavenging and submicron filtration at each filling step, because even invisible contamination builds up over a manufacturer’s lots.
Day-to-day, batches are prepared in controlled environments with careful monitoring. We invest in high-grade glassware and maintain strict batch logs, because we know that traceability turns one-off successes into repeatable wins. Routine analyses—NMR, Karl Fischer titration, and ICP-MS for trace metals—are performed internally before any solution leaves our filling line. Laboratory feedback tells us that some resellers cut costs on their blending, so final product pH can drift outside the target range. We tightly control the final pH (generally between 6.7 and 7.0), and we retest every lot before shipment.
Some customers come to us after seeing ghost peaks on their baseline, often reacting to poorly controlled buffer backgrounds from bulk suppliers. With TEAA, the buffer relies on the volatility and mass-spec compatibility of triethylammonium salts, keeping salt build-up in detectors and transfer lines at bay. We’ve noticed a demand for buffers that don’t demand hours of requalification after batch changes. The HPLC team in our factory runs verification assays—on peptide standards and polar small molecules alike—to spot both the obvious and subtle differences between lots, so users don’t have to recalibrate or adjust gradients each time.
Every manufacturer feels the weight of a routine, and in chromatography, routine shapes workflow. Triethylammonium Acetate finds its primary role as a mobile phase additive or buffer for reversed-phase HPLC, especially when separating peptides, oligonucleotides, or biomolecules where ion-pairing is critical. Laboratories working on protein digests or antisense oligonucleotides find TEAA particularly adaptable. Its volatility makes it well-suited for mass spectrometry, and in our own lab, we have used TEAA because it does not foul source inlets or create ion suppression as harshly as phosphate or non-volatile amine buffers. For researchers following protocols set by ICH or USP, the ready-to-use solution helps bridge method transfers between QC, R&D, and contract labs.
Our own process experience confirmed the importance of consistency, especially for method development. During validation studies for major pharmaceutical clients, we observed how small differences in ammonia or acetate residuals could lead to changes in retention time or baseline drift, particularly with peptides or hydrophobic small molecules. We confronted the common frustration with gradient elution, where a column’s background can change depending on the carryover from prior injections. TEAA mitigates this, presenting a buffer profile that washes out cleanly and allows sharper peak shape compared to standard sodium or potassium buffers.
Experienced analysts have often used sodium acetate, ammonium acetate, or phosphate buffers. Those options suit many organic and small-molecule separations but falter during mass spectrometry coupling, where non-volatile salts can block sources and decrease performance. We recognize the frustration from customers who have spent hours cleaning LC-MS sources. TEAA’s volatility delivers an edge by evaporating quickly under typical running conditions. In our hands, the difference shows most during high-sensitivity protein fingerprinting, where the mass spectrum’s background reveals far less adducting and fewer salt-related noise peaks.
In contrast to sodium-based buffers, TEAA does not precipitate or produce insoluble complexes with metal ions. Chromatographers who run hundreds of samples per day see this advantage as columns last longer and system pressure remains steady. Fielding service calls for collaborative partners’ instruments, our technical team tracks wear and fouling related to buffer composition—less downtime shows up where TEAA is standard practice. We’ve tracked service logs and observed how switching from sodium phosphate to TEAA stretches column usage by several weeks in peptide labs running complex biological matrices.
We’ve handled customer inquiries about inconsistent peak shapes, unexplained drift, or chronic source fouling—often, the root cause traced back to subpar buffer composition. Sodium acetate crystals can stubbornly cling to the tubing or coat pumps, especially as temperatures rise; even tiny crystal formation exacerbates baseline instability and pumps wear. Ammonium acetate, commonly touted for MS-compatibility, doesn’t always provide the same pH stability as TEAA at higher loads or in the presence of complex peptide mixtures. In our own stability tests, we found that TEAA remained clear and colorless at elevated temperatures and high pressures, even after multiple injections in an autosampler sequence. This resilience holds particularly true in 24/7 runs typical in analytical service labs and pharma production environments.
Many resellers offer TEAA but often fall short in the final cleaning stages or fail to filter solutions below 0.22 µm, which we’ve seen result in chromatography system clogs or unexpected background spikes. Our filtration and filling protocols have evolved based on both customer feedback and our own instrument logbooks. On more than one occasion, teams from research hospitals thanked us for the simple fact that their instrument flow paths cleared easier and detectors fouled less often after switching to our solution. This translates to less lost instrument time and more confidence in the downstream analysis of critical samples.
We’ve always believed that robust chemistry doesn’t just start with pure reagents or clever formulations; consistency across production and honest feedback loops with users make all the difference. Our lot-traceability, strict in-process checks, and dialogue with actual chromatographers drive each factory improvement. Instruments perform more reliably and lab personnel report fewer troubleshooting headaches. As analytical chemistry demands higher throughput and absolute data fidelity, buffers like Triethylammonium Acetate, properly prepared, matter more than ever.
High-purity TEAA supports not only the high-end, research-intensive applications but also routine QC testing environments. Facilities running release assays for regulated drugs, food safety, and environmental contaminants have relied on our buffer to reduce surprises between production cycles, test batches, and regulatory filings. The learning curve for new analysts shrinks, and cross-site method transfers move with fewer setbacks.
Some labs have switched from “make-your-own” recipes to our ready-to-use solution. They tell us they gain two things: time freed from prepping stock solutions and a track record of fewer failed runs. We know firsthand the hours lost to remanufacturing fresh buffer solutions due to doubts about accuracy or contamination. Our on-demand solution reduces that uncertainty, building trust batch after batch.
As the chromatographic landscape grows more complex, the push toward higher sensitivity and rapid sample turnaround only strengthens. Research organizations, pharmaceutical producers, and environmental testing centers have all shifted toward workflows that press instruments to full capacity and require buffer solutions they can count on. Triethylammonium Acetate’s particular appeal lies in its volatility, its compatibility with mass spectrometry, and the ability to eliminate tedious wash cycles or column cleaning downtime. These practical benefits appear every day on the production floor in higher useful instrument time and more streamlined maintenance schedules.
It has become clear in our internal studies and from direct customer reports that one of the greatest challenges in large-scale HPLC operations comes from inconsistency in mobile phase preparation. Technicians, even with precise balances and top-line glassware, face subtle but impactful errors when preparing multicomponent buffers. We’ve minimized those headaches by taking the variable out of the process and standardizing all input materials. What shows up in every one of our bottles is the result of genuine feedback from those who rely on chromatography, not marketing flare or cost-based cutbacks. Detailed monitoring of conductivity, residue, and baseline noise helps us ensure that users see only what’s in their sample, not unintended artifacts or ghosting.
Pharma and biotech companies have documented significant improvements in row-to-row equivalency and carryover when switching to our solution for peptide mapping. A large-scale oligonucleotide synthesis facility confirmed reduced baseline artifacts, lowering the need for reanalysis or instrument intervention. Academic research labs have appreciated the simplified method transfer and confidence in reproducible LC-MS conditions. We’ve kept up with published literature and internal client testimonials alike, learning that attention to micro-contaminant profiles distinguishes acceptable results from the industry’s most insightful explorations.
We listen when partners tell us that every time a method changes or every fresh analytical sequence begins, staff members spend less time debugging, backflushing, or chasing random noise when TEAA is at the core of their analytical workflow. Small gains per run, multiplied over hundreds or thousands of sequences, turn into meaningful cost savings and faster project turnover. Our technicians often work hand-in-hand with client labs to analyze trace residuals and help resolve unexplained analytical phenomena—such collaborations continue to refine our process and raise the bar for what a trusted manufacturing partner actually delivers.
Triethylammonium Acetate (2.0 mol/L in Water) has become a trusted mainstay in our own analytical development and in the workflows of countless laboratories at the cutting edge of biomedical research and industrial testing. The practical lessons we’ve learned as manufacturers—surrounding purity, reproducibility, and fitness-for-purpose—feed back into every new batch we produce. It’s a story told in instrument uptime, sharper chromatograms, and more productive lab days. By sharing these lessons and continuing to raise the technical bar, we support both the daily routines and the ambitious breakthroughs of analytical scientists worldwide.