West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

trans-Cinnamic Acid [Matrix for MALDI-TOF/MS]

    • Product Name trans-Cinnamic Acid [Matrix for MALDI-TOF/MS]
    • Alias trans-CA
    • Einecs 208-909-9
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    621942

    Product Name trans-Cinnamic Acid
    Chemical Formula C9H8O2
    Cas Number 140-10-3
    Purity ≥99%
    Appearance White to off-white crystalline powder
    Melting Point 132-135°C
    Solubility Soluble in ethanol, acetone, and DMSO
    Application Matrix for MALDI-TOF/MS
    Storage Temperature 2-8°C
    Boiling Point 300°C
    Synonyms trans-3-Phenylacrylic acid
    Smiles C1=CC=C(C=C1)C=CC(=O)O
    Ec Number 205-398-1
    Pka 4.44

    As an accredited trans-Cinnamic Acid [Matrix for MALDI-TOF/MS] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Trans-Cinnamic Acid (Matrix for MALDI-TOF/MS), 99+%, 25g, supplied in a sealed amber glass bottle with safety labeling.
    Shipping The chemical trans-Cinnamic Acid [Matrix for MALDI-TOF/MS] is shipped in secure, sealed containers to prevent contamination. Packaging complies with standard regulations for chemical transport. It is typically shipped at ambient temperature and labeled according to GHS safety requirements. Shipping is via accredited carriers to ensure safe and timely delivery.
    Storage trans-Cinnamic Acid [Matrix for MALDI-TOF/MS] should be stored in a tightly sealed container, protected from moisture and light, at room temperature (15–25°C). Store in a cool, dry, and well-ventilated area, away from incompatible substances such as strong oxidizers. Ensure the container is labeled appropriately and handled under suitable laboratory safety conditions, including using personal protective equipment.
    Free Quote

    Competitive trans-Cinnamic Acid [Matrix for MALDI-TOF/MS] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    trans-Cinnamic Acid for MALDI-TOF/MS: Direct from the Manufacturer’s Perspective

    A Legacy of Purity Born from Hands-On Experience

    Working with flavors, fragrances, and pharmaceutical intermediates for decades, our journey with trans-Cinnamic Acid runs deep — not just as a supplier, but as the team fine-tuning each batch from raw feed to final product. The lab benches, reactors, and columns in our facility have processed countless tons of this compound. With every order, we are reminded that trans-Cinnamic Acid isn’t just a catalog item. It’s a key that unlocks sharper spectra, trusted by both veteran mass spectrometry professionals and up-and-coming researchers stepping into the world of MALDI-TOF/MS.

    Pure trans-Cinnamic Acid, CAS number 140-10-3, has built a reputation as a matrix compound in MALDI (Matrix-Assisted Laser Desorption/Ionization) time-of-flight mass spectrometry. Laboratories recognize its white to off-white crystalline form, a result of purification steps practiced and perfected over many years, but what keeps scientists coming back isn’t just its appearance — it’s how consistently it performs.

    Why trans-Cinnamic Acid Matters for MALDI-TOF/MS

    Seasoned technicians know that a matrix isn’t just filler for a sample plate. In MALDI-TOF/MS, it’s the launchpad for your analytes. Matrix selection shapes ionization. Select a subpar matrix, and analyte signal suffers: too much background noise, inconsistent crystallization, or poor transfer of energy from laser to sample. Picking trans-Cinnamic Acid means choosing one of the earliest and still most reliable organic matrices for small molecule and biopolymer analysis.

    From our production floor, quality assurance is never a checkbox. Each batch undergoes not only routine purity checks (HPLC, melting point, IR) but performance benchmarking in real analytical runs. Years in business taught us that purity alone does not always translate to sharp peaks on an analyzer; trace contaminants invisible to standard screening may ruin a result. That lesson came hard a decade ago when a customer’s imported matrix failed disastrously in a key protein analysis—since then, we’ve developed customized post-synthesis cleanup for every order destined for MALDI-TOF/MS customers.

    Lab teams working with synthetic peptides, pharmaceuticals, oligosaccharides, or even simple organic acids want confidence that the sample result comes from their molecule, not a dirty matrix. That trust can only be built on rigorous controls at the source.

    Performance Under the Microscope

    With each batch of our trans-Cinnamic Acid, homogeneity and particle size come out at the front line. The best crystals dissolve cleanly in common co-matrix solvents—acetone, acetonitrile, methanol, or water with minimal organic content. Consistent particle size matters: if the matrix doesn’t dissolve evenly, hot spots on your sample plate ruin repeatability. Citrinated hot plates, vacuum ovens, and shelf dryers are all part of our daily grind—these aren’t luxury equipment, but essentials honed to reduce moisture and fines in every yield.

    The word “purity” means little without measurable numbers, so here’s what we check: melting point (132–135°C), HPLC area normalization (usually >99.5%), UV absorption (260 nm, 280 nm), and trace metal analysis by ICP-MS. Each metric has deep roots in feedback we’ve collected from researchers. Some synthetic routes introduce unexpected side products, which piggyback into your results if testing falls short—something seen years ago in imported matrices from traders who cut corners on post-synthesis washing.

    Real-World Application and User Stories

    One university proteomics core approached us about difficulty with peptide mapping in student-run MALDI experiments. They had trialed several matrices, including α-cyano-4-hydroxycinnamic acid (CHCA) and sinapinic acid, but struggled with signal-to-noise and reproducibility. Their biochemists noted that trans-Cinnamic Acid, at the right concentration, brought out previously invisible signals without the background interference plaguing other matrices. Our team worked with them to fine-tune the co-crystallization ratio, adjust solvent gradients, and test wash cycles from different grades of methanol. Over the course of that collaboration, we refined both the product and our technical support to address nitty-gritty issues like sample drop formation, erratic matrix-analyte ratios, and unwanted salt interferences.

    Not every application needs or benefits from trans-Cinnamic Acid; each matrix carries its own strengths. Yet, for small molecule drugs, metabolic intermediates, certain peptides, and plant secondary metabolites, it holds unique advantages. The aromatic, conjugated structure absorbs laser light at 337 nm efficiently, a feature that increases ionization of less polar molecules without excessive fragmentation. Peptide masses commonly jump out with clarity; for researchers working in fields ranging from food safety to environmental metabolomics, this equates to better limits of detection.

    How trans-Cinnamic Acid Stands Apart

    As the team running production, we know every step from benchtop to bulk lot. Unlike distributors who shuffle barrels and hope for the best, we oversee all aspects: starting material sourcing, esterification and hydrolysis, solvent selection, fractional distillation, and phase separation. These are not abstract terms — they are the day-to-day details we track on spreadsheets, batch logs, and sticky notes. If a batch fails our 0.2% impurity cutoff, it gets recycled into non-analytical grade sales, not passed on to core facilities or pharmaceutical clients. This level of care means no unexplained baseline spikes or colored residues in crystals.

    Comparing trans-Cinnamic Acid to other common matrices like CHCA, sinapinic acid, or 2,5-dihydroxybenzoic acid (DHB), reliability and clarity consistently win praise. Several commercial matrices are formulated for broad use, which sometimes means compromise. CHCA, for example, works exceptionally for peptides but can introduce higher background for very small organics. DHB suits large biomolecules but may generate interfering peaks under certain conditions. Our trans-Cinnamic Acid, refined across hundreds of feedback cycles, offers clean spectra in targeted cases, particularly for analytes that resist more polar matrices.

    Early batches years ago didn’t always meet these standards. A batch from 2007, made for an agrochemical client, returned inconsistent melting temperature and sluggish solubility in methanol. That story resulted in a thorough review and overhaul of our purification process, an example of how customer usage directly influences later improvements. Now, every raw material lot comes paired with reference samples for future comparison, and our shelf life testing samples are regularly sent to collaborating academic labs.

    The Realities of Scaling for Quality

    Commercial synthesizers often face the pressure to chase larger volumes — a common pitfall is the temptation to relax controls when increasing scale. We learned the hard way that unchecked side reactions or incomplete crystallization during scale-up risk introducing impurities undetectable in small-scale lots but obvious under mass spec or UV. That’s why process control stays rigorous at every scale; from kilo-lab to full 500 kg production, technicians swap notes and log critical variables, not leaving process drift unexamined. Monitoring starts from starting material (usually cinnamaldehyde, itself sourced from rigorously-vetted botanical processors) right up to final grind. This human touch, the experience of chemists who can spot a batch gone “off” by color, odor, or even sound in the rotary evaporator, can’t be replaced by automated QC.

    Transport and packaging influence performance as well. Some labs still recall the batch that clumped during a humid monsoon run through a port — crystals that traveled warm didn’t perform. Now, each shipment comes vacuum-sealed and packed with desiccants, with batch numbers traceable back to full quality documentation and batch-specific performance certificates.

    Meeting Researcher Needs: Technical Support and Application Guidance

    Beyond the product, supporting researchers and analytical teams is where real partnerships happen. Our technical team is often on the phone with biochemists troubleshooting formic acid compatibility or setting up sample drying protocols that minimize analyte decomposition. Open communication means we regularly refine the product to match the tools in each customer’s lab. When a team in Singapore reported minor UV baseline drift in their acquired spectrum, our chemists traced the issue to trace solvent residues left during crystallization—leading to cleaner vacuum drying and documentation added to all future shipments. Years in business taught us that responsiveness and direct accountability go much further than glossy marketing in building loyal users.

    Researchers tackling new analytes or shifting to novel ionization techniques often approach us for input. Instead of blanket recommendations, we draw on years of small failures — misjudged solvent ratios, unnoticed plate imperfections, and laboratory surprises. Our support emphasizes shared learning: troubleshooting failed runs by walking through their sample prep, re-examining laboratory water sources, or recommending alternative pipetting techniques. Hundreds of customers and collaborators have improved their results by implementing solutions based on shared experience, not just technical claims.

    Beyond Simple Supply: Our Continuing Drive for Improvement

    Manufacturing chemicals for life sciences is a never-ending process of feedback and small technical advances. Every batch of trans-Cinnamic Acid embodies improvements won through customer feedback and practical fixes to real-world problems. Early on, we identified the sources of colored impurities, adapting our crystallization techniques. We responded to user demand for thinner crystal distributions with a change in grinding and sieving protocols, making the matrix dissolve faster for high-throughput laboratories. A distributor once asked for a “greener” process, and the search for suitable solvent alternatives led us to a less hazardous workup method, now standard in our plant.

    Analytical chemistry changes at a rapid pace, and so must the products that serve it. As researchers push for higher throughput, lower detection limits, and automated analysis, the pressure on matrix quality grows. Robotic spotting and automated sample loaders challenge us to maintain batch-to-batch consistency with even finer tolerances. We’ve introduced computer vision systems to flag out-of-spec particle sizes and machine-readable certificates of analysis for rapid onboarding into digital lab systems, but human oversight — experienced chemists cross-checking pixelated images with old-fashioned glass slides — keeps the process real and responsive.

    Regulatory Compliance, Traceability, and Ethics

    Running a chemical plant brings responsibility for compliance and traceability. Every batch leaving our facility for analytical use is produced under protocols that meet international standards and full documentation to retrieve batch records for any given order. Our plant operates under occupational safety and environmental compliance as standard, with waste minimization and solvent recycling not just marketing phrases but line items in our operating budget and daily logs. We value transparency because our customers, especially those in regulated spaces such as pharmaceuticals, demand it. They want full traceability of every reagent and confidence in batch reproducibility — a promise earned through practice, not marketing.

    Customer ethics drive our actions as well. We reject any requests for “off the book” substitutions or acceptance of second-choice lots for end-uses in critical human or animal diagnostics. We would rather forgo a sale than risk a clinical lab’s result due to questionable analytical reagents. If a research group or diagnostic lab finds even the smallest deviation, our protocol is to recall, investigate, and replace, not pass blame or dodge the issue. This approach, shaped by hard-won trust over years, is why many research teams consider our products integral to their analytical pipelines.

    Reflections from Inside the Plant

    Looking back at decades in production, our pride isn’t in glossy packaging but in the quiet confidence that comes from solving real problems for real users. No amount of distribution channels or trading platforms can substitute for firsthand knowledge — the insights you gain only from breaking down and improving a process yourself. Each order for our trans-Cinnamic Acid matrix passes through the same hands that have optimized hundreds of batches. Every kilo contains the history of failures, lessons, and collaboration with scientists who push the boundaries of detection and identification.

    Matrix compounds rarely receive headlines in the world of analytical chemistry, yet they’re pivotal in every lab’s daily successes and challenges. Our reputation stands on following through — not just filling an order, but listening, adapting, and committing to better tools, cleaner results, and honest service. We believe that’s what every research lab deserves, whether they are exploring new drug candidates or developing the next breakthrough in metabolomics.

    Practical Tips for Achieving the Best Results

    Over the years, direct feedback has shaped how we recommend using trans-Cinnamic Acid in real labs. Experienced MALDI-TOF/MS users often suggest dissolving the matrix in HPLC-grade solvents, filtering through a 0.2-micron PTFE membrane, and avoiding plasticware contamination. Co-crystallization with analytes works best with gentle air drying rather than oven drying, which sometimes promotes uneven distribution. For high-throughput applications, automated pipetting systems achieve better reproducibility than manual spotting, provided the matrix solution remains fresh and well-stirred.

    Our team keeps a library of user-tested protocols that include tips for solubility, matrix-to-analyte ratios, and laser intensity adjustment. Researchers have improved their results by switching to our recommendations on storage (dried, sealed, room temperature out of direct light) rather than relying on refrigeration or humidity-prone environments, especially in tropical climates. If a sample yields cloudy or tinted crystals, troubleshooting usually starts with solvent checking and ends with an evaluation of glassware cleaning and matrix lot history—issues spotted and documented through close work with dozens of advanced users.

    Sample variability has many causes, and every MALDI plate runs into quirks. Overly thick spots, matrix burns, and unexplained low signal plague even experienced labs, but process corrections — changing solvent, tweaking co-crystallization, or switching to glass spotting plates — rapidly resolve most issues. Distributed feedback, annotated protocols, and lab visits from our own staff have all contributed to the shared pool of best practices available to users of our trans-Cinnamic Acid matrix.

    Onward: The Path Forward for Analytical Matrices

    As innovators in analytical chemistry keep stretching their instruments’ performance, the benchmarks for reagents only rise. Matrix products like trans-Cinnamic Acid look simple to an outsider, but the competitive edge lies in continual process improvement, real human accountability, and a willingness to learn from every customer. Reliable supply, honest technical support, and the dogged pursuit of meticulous production standards define our approach — an approach tested every day in research labs, pharma facilities, and quality control centers worldwide.

    Listening closely, communicating transparently, and improving processes based on daily feedback are not optional in the world of high-stakes analytical chemistry. Our commitment is to respond, to adjust, and to stand behind the science — not just as a supplier, but as your partner in advancing discovery.