|
HS Code |
549881 |
| Chemical Name | SU 5416 |
| Synonyms | Semaxanib |
| Cas Number | 192441-08-0 |
| Molecular Formula | C22H16N4OS |
| Molecular Weight | 384.46 |
| Appearance | Yellow crystalline powder |
| Solubility | Soluble in DMSO, poorly soluble in water |
| Mechanism Of Action | VEGFR-2 (KDR) tyrosine kinase inhibitor |
| Storage Temperature | -20°C |
| Purity | Typically ≥98% |
| Usage | Research and experimental purposes only |
| Target | Vascular endothelial growth factor receptors |
| Iupac Name | 3-[(2,4-dimethylpyrrol-5-yl)methylene]-1,3-dihydroindol-2-one thiosemicarbazone |
| Melting Point | 243-245°C |
| Stability | Stable under recommended storage conditions |
As an accredited SU 5416 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SU 5416 from Sigma Aldrich arrives in a 25 mg amber glass vial with tamper-evident seal, labeled for research use. |
| Shipping | SU 5416 is shipped as a hazardous chemical via air or ground with appropriate packaging in accordance with international regulations. The compound is typically packed in sealed containers, protected from light and moisture, and shipped at ambient or controlled temperatures, depending on supplier guidelines (Sigma Aldrich, Merck, TCI). Shipping documentation is included. |
| Storage | SU 5416 should be stored at -20°C, protected from light and moisture. Keep the container tightly closed in a dry, well-ventilated area. This chemical is light-sensitive and should be handled under subdued light. Ensure proper labelling and segregation from incompatible substances. It is recommended to follow the supplier-specific guidelines (Sigma Aldrich, Merck, TCI) for optimal storage conditions. |
Competitive SU 5416 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Our team has spent years working directly with SU 5416, also known by researchers by its synonym semaxanib. We know this compound from the ground up: we designed its steps, controlled every run, refined every lot. SU 5416 is a synthetic small molecule, formally described as an inhibitor targeting vascular endothelial growth factor receptor-2 (VEGFR-2), also called KDR/Flk-1. Its molecular formula is C22H16N4O3, and it weighs in at 384.39 g/mol. Our experience lets us see SU 5416 for what it is—a blend of precision chemistry and applied biomedical science, rolled into the fine yellow-beige powder you find in the bottles we ship around the world.
Chemists who have handled dozens of kinase inhibitors can tell SU 5416 apart immediately by its structure, marked by the presence of a semicarbazone moiety and a quinoline scaffold. During synthesis, this scaffold demands careful handling, especially under controlled temperature and humidity, to avoid unwanted side products. The molecule’s functional groups grant reactivity—but also force attention to detail, stability assessment, and regular batch testing. We sample every batch through HPLC and NMR to confirm over 98% purity before release. Our analytical chemists sign off on the certificate, not a distant reseller. That’s how we guarantee the right material for your bench work.
Drug discovery efforts aimed at antiangiogenic therapies rely on consistent, reproducible inhibitors of VEGFR-2. SU 5416 plays a starring role here. Researchers reaching for this molecule are usually studying angiogenesis in cancer, ocular disease, pulmonary hypertension, and models of neurovascular disorders. Its well-characterized mechanism—a direct block of the ATP-binding site of VEGFR-2—lets research teams create clear, comparative studies. From animal models of tumor growth to targeted tissue studies, SU 5416 gives a definitive tool. Our own process, beginning at raw material sourcing, means reproducibility never wavers between batches—critical for robust, reviewable data. We have heard more than one story from customers who traced inconclusive animal data to inconsistencies between alternate lots from resellers. Our aim remains simplicity: every bottle behaves like the last.
Because SU 5416 interacts with pathways controlling new blood vessel growth, it finds its way into a wide variety of test systems. Its applications reach from bench studies in primary endothelial cells, to in vivo rodent and zebrafish models, to larger preclinical and toxicology investigations. The molecule modulates a defined pathway, so off-target activity is minimal compared to broader kinase inhibitors. From a manufacturer’s view, we have a responsibility to prepare the molecule using reagents free from tin, mercury, or halogen residue, which could confound biological experiments.
Working directly in this field, we see a sea of kinase inhibitors sold as “broad-spectrum.” Many blur the line between specific pathway research and general cytostatic effects. SU 5416 stands apart through years of peer-reviewed data showing specificity for VEGFR-2/KDR, with less spillover to unrelated kinases, such as PDGFR or FGFR families. We have worked with researchers attempting to switch from other classes, especially those using sunitinib or sorafenib, looking for clean differentiation in pathway analysis. They report that side-pathway effects often obscure signals. With SU 5416, downstream readouts—phosphorylation markers, tube formation, angiogenic gene expression—respond in line with published standards. We have learned that a well-made batch, when dissolved in DMSO or ethanol, bears no trace of interfering UV peaks, a concern with lower-purity or poorly crystallized material from non-manufacturing sources.
Unlike compounds such as axitinib or vandetanib, SU 5416 lacks iodine or heavy halogens in its structure. This simplifies analytical controls and disposal, making it a trusted tool for environmental safety in the lab. Investigators focused on early-phase translational work appreciate knowing their secondary metabolites remain straightforward under LC-MS conditions.
Over the last decade, storage recommendations have changed from theory to observation. We began recommending -20°C freezer storage before shipping every pack with desiccant and clear labeling. Repeated cycles at ambient temperature impact quinoline-containing molecules, so we set up batch testing protocols at multiple time points—over a year, at both controlled room and cold storage. Our longest batch, synthesized in 2018, retained full potency after three years at -20°C. After two days at room temperature, no hydrolysis or breakdown appeared in HPLC chromatograms. We put every batch through stress tests, using both short and long-chain alcohols for solubilization. Some earlier methods left residue; our current process delivers highly soluble product, leaving no sticky mass in the vial after DMSO or ethanol addition. This change grew from direct feedback: a postdoc in southern Europe struggled with partial solubilization, prompting us to improve crystallization steps.
Researchers usually require small amounts of SU 5416 for pilot studies, then larger volumes for extended dosing regimens. Pack sizes from milligrams to grams support this, with no compromises in purity. University groups often need sub-gram lots, while industry-scale partners running months-long studies request bulk. We prepare all orders from a single, traceable lot, so larger programs never hit a wall from batch-to-batch inconsistencies.
Studying pulmonary hypertension in small animals requires more than a theoretical understanding—timing, dosing, and route of administration all influence outcomes. Our collaborations with labs worldwide have shown us how intravenous or subcutaneous dosages of SU 5416 modulate pulmonary vascular remodeling. We have worked with teams refining protocols for the Sugen/Hypoxia rat model, instrumental in replicating features of human pulmonary hypertension. Success here lies in molecule consistency: unreproducible results link straight back to variability in product purity, moisture content, or unintended byproduct inclusion.
Cancer groups often use SU 5416 to dissect tumor angiogenesis. As an upstream VEGF pathway blocker, it gives clean separation from broader cytostatic agents. Investigators find SU 5416 an effective baseline for comparing newer drugs—they can control study variables, using our lot-specific certificates to validate their starting material. Our direct discussions with academic and pharmaceutical groups reveal one persistent theme: unambiguous, repeatable results are only possible with well-characterized batches. The molecule’s short half-life in vivo (usually 2-7 hours in rodent models) means dosing intervals need tight control; we publish our analytical and stability data to help design these studies.
Some programs aim beyond cancer and pulmonary conditions. Damage to the retina, post-stroke blood-brain barrier dynamics, and wound healing models draw on SU 5416’s proven activity. Groups working with transgenic animals benefit from confidence: the molecule performs as predicted across backgrounds, without odd side-pathway effects.
Supplying SU 5416 brings responsibility. As manufacturers, mistakes in process ripple directly into experimental outcomes. We redesign each lot for traceability, right from sourcing of quinoline precursors to the crystallization stage. Moisture handling receives special attention—our packaging features double-layer barriers against humidity incursion, plus integrated tamper indicators. Lab customers tell us that assurance of dryness beats paper specs. We respond with individual moisture readings per lot, never relying on supplier claims for solvents or starting materials.
We have refined the route to minimize waste and retain high optical purity. Our internal teams hold deep knowledge about the scalability challenges of multi-step small molecule synthesis, especially for molecules where batch crystallization kinetics dictate downstream yields. Training programs keep new operators aligned with long-tested protocols, ensuring no step gets skipped on a busy day. Every gram that leaves our site represents months of iterative development, troubleshooting, and hands-on effort. We build direct relationships with users in both academia and pharma, learning where their challenges lie. This feedback loop helped us eliminate byproducts flagged as trace kinase inhibitors years ago, using advanced flash chromatography and vacuum-assisted drying setups.
Kinase inhibitor research covers a crowded field. Pan-kinase blockers often leave too much background noise. SU 5416, structured for specific VEGFR-2 recognition, consistently generates selective effects. Our own side-by-side runs with sunitinib, pazopanib, and regorafenib show clear separation in kinase panel assays. Downstream, phosphorylation signatures demonstrate exclusive suppression in the VEGF pathway. For teams aiming for pathway isolation, SU 5416 minimizes compensatory signaling shifts, a finding repeated in both our own cell-based work and customer reports.
Physicochemical properties also set SU 5416 apart. Lack of halogenated or nitroaromatic groups means reduced risk of hazardous byproducts under photolytic or combustion conditions. Many newer inhibitors now entering the market show tendency toward off-target CYP450 effects or require elaborate handling protocols. SU 5416 remains stable under standard research lab environments, so extra precautions usually reserved for volatile, halogenated inhibitors do not apply. Our process validates flash points, vapor pressure, and decomposition temperatures, supplying real-world data for point-of-use risk assessment.
Our direct involvement with global research means adjusting to varying demands. European clients highlighted packaging needs for intact transport across borders, so we fortify every international shipment with cold packs and custom foam inserts. US and Canadian customers required tamper-evidence and easy-lot recall, prompting us to serialize every vial. Asian partners appreciate detailed batch logs and immediate online access to our certificates. These stories, collected over years, shape our operation as much as any synthesis guideline.
Facilities working at GLP (Good Laboratory Practice) or GMP (Good Manufacturing Practice) levels need full chain of custody records. We provide this. Our web portal supports downloads of batch-specific reports, updated stability data, and technical notes—drawn from our own laboratories, not sales teams. Long-term users draw confidence from knowing the synthetic route has not changed, and that any process innovation passes rigorous equivalency testing before implementation.
We approach SU 5416 production with an eye toward environmental stewardship and continual process improvement. Early protocols created more solvent waste than we were comfortable with. Now, solvent recovery systems reuse and distill significant fractions at every stage, shrinking footprint and waste. Solid phase cleanups cut down on wash water and lower overall extraction time. We designed our process to avoid regents flagged for environmental persistence. Our sustainability audits measure real outcomes—reduced energy input, less packaging, routes that prioritize greener alternatives. Feedback from environmental health and safety partners steers ongoing redesign.
Long-term partnerships with universities and pharmaceutical companies demonstrate the viability of well-made SU 5416. Their teams value not just the molecule but the transparency, communication, and shared learning. We know that reliability outpaces lowest price. If repairs or modifications are necessary, our chemists confer directly with researchers—lessons drawn from these conversations cycle back into manufacturing improvements. The sum of these efforts: every batch supports not just current programs but a future of smarter, safer, more reliable research.
Even as we focus relentlessly on product quality, we actively support labs in integrating SU 5416 safely. Our documentation goes well beyond standard-issue sheets: technical teams run monthly webinars highlighting safe weighing, solution preparation, PPE practices, and waste disposal. Customers take part in sample walkthroughs—they tell us the hands-on approach removes ambiguity. Our internal health and safety staff field technical concerns around SU 5416’s reactivity, endocrine-disrupting potential at high doses, and best practices for disposal. Feedback is integrated into our ongoing training modules and packaging guidelines.
We also recognize that SU 5416, like any VEGF pathway inhibitor, brings intrinsic risks to those handling concentrated solutions. Synthesis and purification teams receive periodic refresher courses. Our knowledge base—built through years, not months—directly benefits those new to the compound, letting them sidestep common pitfalls. Every new manufacturing operator passes hands-on exams. These precautions extend out to the research community: we publish technical notes on safe solvent selection, and offer updated guides based on questions from working scientists.
Our commitment to SU 5416 stretches over fifteen years. Each gram reflects technical mastery, continuous learning, and respect for the researcher’s end goal. The journey from raw material to crystalline product is marked by thousands of small refinements—each solving challenges uncaught by textbook synthesis. We see the molecule not as commodity, but as a bridge between chemical expertise and scientific discovery. The feedback loop, running from the bench to our plant floor, keeps us responsive in a rapidly evolving research world.
Over its history, SU 5416 continues to serve as both a definitive research tool and a benchmark for new compounds. Labs building on oncology, vascular biology, neuroscience, and translational medicine find in SU 5416 a partner for clarity and reliability. Our efforts—traceable supply chains, transparent data, strict control of synthesis steps—bring confidence to the bench scientist, whether they are running their first experiment or charting new territory in drug development. We see the impact firsthand through published studies, conference collaborations, and direct success stories shared by our partners.
SU 5416 means more than a product in a catalogue. Through chemical precision, years of iterative development, and open collaboration, it embodies the intersection of manufacturing skill and scientific aspiration. We remain ready to address emerging needs, refining our work not just for the molecule, but for every person who sets out to use it in the pursuit of discovery.