|
HS Code |
551426 |
| Productname | Streptavidin FITC Conjugate |
| Conjugate | Fluorescein isothiocyanate (FITC) |
| Host | Recombinant Streptavidin (commonly bacterial expression) |
| Form | Liquid |
| Concentration | Varies by supplier; typically 1 mg/mL |
| Buffer | Phosphate-buffered saline (PBS) |
| Storageconditions | 2-8°C, protect from light |
| Molecularweight | Approximately 60 kDa (tetrameric form) |
| Excitationwavelength | 495 nm |
| Emissionwavelength | 519 nm |
| Application | Detection of biotinylated molecules in flow cytometry, microscopy, and ELISA |
| Purity | ≥95% by SDS-PAGE |
| Preservative | May contain sodium azide |
As an accredited Streptavidin FITC Conjugate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The Streptavidin FITC Conjugate (Sigma Aldrich) is supplied in a 1 mg amber glass vial, sealed, with tamper-evident cap and label. |
| Shipping | Streptavidin FITC Conjugate (Sigma Aldrich/Merck/TCI Chemical Grade) ships in light-protective packaging, typically on ice packs or dry ice to maintain stability. It is classified as a non-hazardous reagent and requires temperature-controlled, expedited delivery. Handling instructions emphasize avoiding direct sunlight, temperature fluctuations, and prolonged ambient exposure during transit. |
| Storage | **Streptavidin FITC Conjugate (Sigma Aldrich/Merck/TCI Chemical Grade)** should be stored at 2–8°C, protected from light to prevent degradation of the fluorescent label. Avoid repeated freeze-thaw cycles and ensure the container is tightly closed to prevent contamination and moisture exposure. For long-term storage, aliquot and keep at -20°C. Always consult the manufacturer's datasheet for specific handling instructions. |
Competitive Streptavidin FITC Conjugate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
In the course of developing antibodies and diagnostics at scale, we’ve recognized how much hinges on reliable labeling. The Streptavidin FITC Conjugate stands out for its consistency and fluorescence performance. As a manufacturer with years of batch validation for immunoassay reagents, we test for more than the advertised properties. Our priorities extend past reading a spec sheet: We observe signal-to-noise ratios, spot issues in spectral separation, and run stability checks under real lab conditions. It’s one thing for a conjugate to perform in a pristine demonstration. It takes a different level of precision for it to withstand shipping, storage, and the unpredictable workload of a busy life science lab.
This conjugate combines high-affinity streptavidin with fluorescein isothiocyanate—the standard FITC fluorophore—for quick, robust biotin detection. The streptavidin-biotin interaction remains the benchmark for non-covalent molecular binding: tight and almost irreversible under most experimental setups. We conjugate at ratios that deliver bright, consistent signal while avoiding over-labeling, which can wreck both stability and specificity. Every lot gets evaluated for fluorescence intensity and biotin binding capacity—backed by application-driven validation, not just chemical analysis.
Through direct feedback from our project teams and clients, we have refined the formulation to retain activity after freeze-thaws. Many commercial FITC conjugates lose punch after exposure to ambient conditions, leading to inconsistent results or the need to use excessive quantities. By optimizing storage buffer and using gentle purification, we get a product that resists aggregation and photo-bleaching much longer.
We pay close attention to lot-to-lot consistency, as even minor variations in labeling can play havoc when running quantitative assays. In live cell and fixed tissue protocols, the signal persists through imaging workflows, with low background thanks to careful removal of unconjugated dye. On our in-house immunoassay validation runs, the conjugate provides clear separation of positive and negative signals even at low biotinylated target concentrations.
While internal model numbers serve for traceability, the practical focus stays on what users actually experience: performance in ELISA, Western blot, flow cytometry, and IHC. Each vial contains purified streptavidin labeled to an optimal F/P (fluorophore:protein) ratio, which we determined after extensive comparison tests. Too little dye, and signals drop. Too much, and streptavidin loses biotin binding power. Through trial and error, plus steady dialogue with users, we arrived at a formulation targeting bright fluorescence with strong binding.
All steps safeguard activity: from the initial selection of ultrapure streptavidin, through the coupling reaction, to careful buffer exchange and filtration. Absorbance and emission readings fall within the typical FITC range: absorbance maximum near 495 nm, peak emission near 519 nm. But what matters in practice is batch transparency—being able to trace why one lot performs as expected, should any rare issues arise. Real fluorescence units per microgram, determined lot by lot, anchor our certificates of analysis. We provide reference data for our internal controls with every release, rather than hiding behind generic catalog entries.
We have seen this conjugate support a wide range of fluorescent-based biotin detection. In sandwich ELISAs, it tags secondary biotin-labeled probes for fast, clear readouts. Researchers preparing bead arrays lean on the conjugate’s low background for multiplexed detection, capitalizing on FITC’s established position in fluorescence readers and flow cytometers. Immunohistochemistry protocols use the conjugate to visualize target proteins, leveraging bright green fluorescence for unambiguous cell and tissue mapping.
Good protocols demand more than high starting fluorescence. So, we look at photostability and the effect of mounting media on fluorescence output. Using our conjugate, we’ve recorded strong signal retention after multiple wash steps and up to several hours of continuous imaging. In flow cytometry, peak heights match or surpass many imported products, while keeping background—autofluorescence and bleed-through—lower due to the clean labeling profile.
Colleagues in lateral flow development have shown that the conjugate maintains visibility even in dry phase settings. We have repeatedly observed that lateral flow strips developed with our conjugate retain their signal without running or patchiness, after months of shelf-life testing at various climates. If protocols require avidin inhibition experiments, the conjugate responds reliably to both free and conjugated biotin, without cross-reactivity that sometimes plagues conjugates made with impure dye stocks.
It’s easy to find fluorescent conjugates, but the gap widens in side-by-side application runs. Some imports show uneven labeling, making standardization tough. Poor purification can mean high free FITC, increasing non-specific signals. Our approach removes unconjugated dye by thorough post-conjugation filtration, with each batch checked for residual unbound fluorophore. This keeps background low and signal crisp on slides or in suspension.
We choose gentle methods at every stage. In the coupling step, strictly controlled pH and temperature keep the protein backbone intact. This means less denaturation and longer shelf life. Every shipping batch runs through on-site stress testing—exposure to light, ambient temperatures, and freeze-thaw cycles. Subtle shifts here can wreck a project’s controls, so we never skip this step.
Other manufacturers may boost apparent signal by overdosing with FITC. This causes photobleaching and, worse, compromises biotin binding by blocking active sites. Through iterative formulation and actual usage evaluations, we hit a balance: high brightness with true biotin affinity. Labs switching to our product from others often report the same experience, noting less experimental drift and more repeatable results over time.
Trust grows with openness. For every lot, we include batch reports that disclose absorbance, emission, F/P ratios, and direct biotin-binding measurements side by side with control benchmarks. Should issues appear during user protocols, detailed batch records help us rapidly diagnose root cause, going well beyond generic troubleshooting guides.
Designing this conjugate, we anticipated what goes wrong in actual field use: photobleaching under fluorescence microscopy, declining signal in stored slides, baffling background in flow panels. By bringing feedback from real-life diagnostics and assay builders into our formulation cycles, we keep improving robustness. If trends show that a certain buffer formulation improves signal stability for a partner’s unusual cold chain, we adapt. Application support staff are familiar with the entire production lifecycle and regularly communicate with our R&D to incorporate hard-won improvements.
The field keeps moving: higher throughput assays, broader multiplexing, and demand for lower detection limits put pressure on reagents to deliver more consistency. Our team invests in both the upstream manufacturing—refining purification steps, quality controls, and raw material sourcing—and the downstream, tracking how products perform in real customer hands. Every batch brings new insights.
We take stability seriously. Lyophilization protocols underwent repeated cycles of simulated shipping and long-term storage. Our vials protect fluorescence even after repeated freeze-thaw or month-long bench sitting. This reliability matters for university core labs as much as for industrial proteomics facilities handling thousands of samples.
Protocols have grown more sophisticated, requiring conjugates to persist through harsher washes, longer incubations, or exposure to mounting media with diverse compositions. We adjusted our protocols based on real feedback, swapping out preservatives that interfered with signal and optimizing buffer compatibility with immunodetection kits from various suppliers. Sometimes, the real test comes not at the quality control bench but at 3 AM, when someone runs a panel for the fourth time and needs the signal to behave just as expected.
From day one, we’ve kept short feedback loops between our users and the production line. If a large clinical lab or academic group reports a shift—in performance, background, or photostability—we don’t just log it as support. Our teams troubleshoot together, sometimes re-analyzing retained vials from the same batch under the same temperature and storage stress as the field. This tight approach closes the distance between manufacturing decisions and field performance, building a body of know-how that keeps standards rising.
We do not market FITC conjugates with vague promises about “universal compatibility.” Our records show which platforms and workflows have proven their reliability with our product and where small tweaks improved consistency. By tracking which commercial biotinylated antibodies and antigens have shown strongest signal responses, we maintain a base of knowledge you won’t find in off-the-shelf catalog products.
The streptavidin-biotin pairing ranks with the most reliable molecular interactions—the extremely tight binding isn’t mere marketing lore, but a fact reinforced by decades of kinetic studies. The FITC fluorophore, with its well-characterized excitation and emission spectrum, slips into the majority of fluorescent microscopes and plate readers. Our pairing of these two, subjected to a rigorous series of in-house validations, pushes consistency to the forefront.
Having produced thousands of grams over multiple years, we’ve seen how a minor quirk in one input can cascade through to unexpected fluorescence drift or loss of binding. Every run is tracked back to original streptavidin lots and dye stocks, noting supplier and handling conditions meticulously. Our last several years of field data show lots deliver a detection limit consistent within a 10% range for the majority of ELISA and flow cytometry assays, even after prolonged storage and shipment across temperature swings.
For users developing diagnostic kits, the value of this traceability cannot be overstated. The cost of lost time or inconclusive controls outweighs any savings from lower-cost alternatives. Having both short-term application data and multi-year field stability reports lets users calibrate their expectations and protocols without constant retraining or last-minute tweaks.
Every year brings incremental changes in biotin detection systems, newer fluorophores, and updated imaging systems. But FITC remains a benchmark dye, thanks to broad compatibility and ease of detection. Our manufacturing workflow focuses on integrating emerging feedback, updated raw material sourcing, and improvements from peer-reviewed developments into every step.
For users, this means a source of streptavidin FITC where batch performance remains predictable, documentation never leaves unanswered questions, and technical support gets straight to the critical details. With the crucial processes—from conjugation chemistry to vial sealing and long-term shipment testing—happening under one roof, our teams spot and fix issues early. This direct line accelerates not just problem solving, but genuine process improvement—aligned with the needs of scientists depending on a stable fluorescence signal in every experiment.
Every bottle of Streptavidin FITC Conjugate that leaves our facility carries the results of persistent iteration, expertise, and real-world stress testing. From optimizing the F/P ratio to extensive batch tracking and open defect logging, we take the responsibility seriously—because a conjugate’s shortcomings show themselves outside of perfect conditions. Our commitment is simple: offer a product that consistently delivers clear, bright signals backed by real data, with full transparency for every lot. Those building tomorrow’s diagnostics, publishing today’s discovery research, or handling high-throughput routine testing will continue to recognize the value of a product shaped by hands-on manufacturing experience—where results matter more than abstract claims.