HS Code |
813475 |
| Product Name | Silica Gel (Spherical, 100µm) [for Column Chromatography] |
| Appearance | White spherical beads |
| Particle Size | 100 µm |
| Shape | Spherical |
| Ph Range | 6.5 - 7.5 (in 5% suspension) |
| Surface Area | 600 - 800 m²/g |
| Pore Size | 60 - 100 Å (angstroms) |
| Bulk Density | 0.7 - 0.8 g/cm³ |
| Loss On Drying | <6% (at 105°C) |
| Purity | >99% |
| Chemical Formula | SiO2 |
| Solubility | Insoluble in water and organic solvents |
| Moisture Content | <7% |
| Application | Column chromatography |
| Storage Temperature | Room temperature |
As an accredited Silica Gel (Spherical, 100µm) [for Column Chromatography] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging is a 500 g white plastic bottle, labeled "Silica Gel (Spherical, 100µm)", suitable for column chromatography, from Sigma Aldrich. |
| Shipping | Silica Gel (Spherical, 100 µm) for column chromatography is shipped in sealed, moisture-proof containers to prevent hydration. It is classified as non-hazardous for transport. Ensure upright handling and store in a dry area upon receipt. Standard shipping practices by Sigma Aldrich/Merck/TCI Chemical apply, following all relevant regulations. |
| Storage | Store Silica Gel (Spherical, 100 µm) for column chromatography in a tightly sealed container, away from moisture, heat, and direct sunlight. Keep in a cool, dry, ventilated area, and avoid exposure to acids or alkaline substances. Ensure proper labeling, and handle in accordance with standard laboratory safety protocols. Use only in well-ventilated spaces to minimize dust formation. |
Competitive Silica Gel (Spherical, 100µm) [for Column Chromatography] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Inside the plant, silica gel stands as the workhorse of many separation processes. The 100µm spherical type developed right here reflects years of production know-how—carefully balancing the chemistry and process conditions during gel formation. Our experience has shown that achieving this particle size, in spherical form, isn’t just a matter of sieving. It requires tight control over hydrolysis rates, pH, and drying cycles. We’ve watched as each batch shapes up in the granulators, and those uniform spheres are not a lucky accident. Each size range has its own quirks—100µm spheres strike a sweet spot, providing reliable flow characteristics without excessive backpressure in the column.
Many in labs, from academia to industry, immediately reach for spherical silica for chromatography work, once they’ve seen what inconsistent particle shapes can do to separation. Fragmented or irregular particles create dead volumes, broadening peaks and making purification tricky. Our team observed this firsthand back in the early days, when stickier, angular gels would hang up solvents in pockets, slowing runs and wasting precious product. The geometry of spheres—consistently produced by our in-house processes—reduces channeling in packed beds. This translates to sharper separation and repeatable performance, which matters deeply in both analytical and preparative applications.
True 100µm spherical silica isn’t just about particle size distribution. During QA, we check pore structure and surface area with utmost care, not to chase marketing figures but because we’ve seen how deviations directly affect elution profiles. A higher surface area provides more adsorption sites, which improves fractionation, but too high and it’ll hold onto solvents longer. By controlling synthesis, our gels present a median pore size suited to a wide array of mobile phases, including both polar and non-polar solvents. Practical experience taught us that maintaining purity is essential—trace metals or residual processing additives have ruined more than one critical separation in R&D projects. For this reason, raw materials for our silica start with carefully sourced sodium silicate and acidified with deionized water under clean conditions. Batch retention samples serve as forensic evidence in any outlier case.
Packing columns seems simple on paper, but small differences in gel consistency have a big influence under constant flow. We’ve helped customers troubleshoot cases where user-packed columns yielded inconsistent results—hasty column fills led to settling or air gaps, impacting resolution. Our 100µm spheres offer predictable packing density, and the spheres support a stable bed under both gravity and pressure-driven flows. When eluting, these spheres resist fines production, which keeps pressure drops stable across long runs. Technicians working on scale-up projects routinely highlight less clogging and fewer flow interruptions, especially in preparative chromatography for APIs, plant extracts, and fine chemicals. Over years of real-world runs, we’ve tracked substantially lower column backpressure and better sample recovery rates compared to non-spherical or off-grade materials.
Size matters, and so does shape. Within every lot, our plant technicians routinely check for outlier shapes, rejecting any that threaten to compromise the bed structure. 100µm offers a balance between speed and resolution often sought by process and analytical chemists—smaller particles (like 50µm) can give higher resolution, but demand higher pressures and costly equipment modifications. The 100µm range excels for routine work, mid-scale purification, and cases where pressure limitations exist. Compared to irregular silica, these spheres load easily, flow more evenly, and enable better reproducibility across columns and runs. We see this time and again from both pharmaceutical and specialty chemical manufacturers: well-resolved fractions, reliable scaling from bench to pilot plant, and stable bed heights—these benefits flow directly from process control at the manufacturing stage.
Consistency has kept long-standing customers returning year after year. This product reflects not just a formula, but strict adherence to well-established, hard-won production standards. Each batch of silica sees in-process testing: moisture, acidity, particle checks, and absence of extraneous contaminants. Our technicians perform hands-on, labor-intensive sieving and inspection to rule out broken beads or powdery fines. Plant audits, both internal and customer-led, have scrutinized our clean rooms, raw material batches, and drying ovens. We built these controls because we’ve lived through the chaos that subpar raw materials can create—overheating in packed beds, or tailing peaks under seemingly identical operating conditions.
We received direct feedback from contract research organizations who lost days to contaminated runs caused by poorly manufactured silica. At our plant, every load of sodium silicate is checked for metals and organics, and mother liquors are tested before neutralization. We’ve learned that minute residues, undetectable to the naked eye, change how compounds move in a column. That’s why we don’t tolerate shortcuts in washing or drying stages. Year after year, analytical users—especially those producing clinical or API timelines—request supporting certificates to prove batch-to-batch consistency. We respond with detailed technical support, sharing chromatograms and residual metal reports from our own QA, not third-party summaries.
Our 100µm spherical silica finds a home wherever reliable separation is needed. Chemical synthesis labs, pharmaceutical QA, environmental monitoring stations, and even seed oil analysts rely on the repeatable results these spheres deliver. In our own process development programs, we used these gels to purify enzyme reaction products and extract trace contaminants from recycled solvents. In India’s dye manufacturing sector, our product helps avoid costly rework by letting colorants move predictably through the purification stages. For manufacturers scaling up, predictable pressure profiles and lower risk of column collapse are confirmed advantages.
Irregular silica, often produced by legacy wet methods, finds still some niche use due to lower production cost. Yet over 15 years, our own pilot runs confirmed that irregular shapes lead to greater solvent usage, more frequent clogs, and higher rates of undesirable tailing in chromatograms. We’re old enough to remember frustrations when columns loaded with irregular gel cracked or shifted mid-run; modern spheres, by contrast, keep the bed jointless, even over extended operations. Tiny dust-like fines common in substandard or poorly classified products complicate filtration and can harm expensive analytical equipment. Our plant’s tight screening and dust management ensures the material won’t be the weak point in a customer’s workflow.
Not all chromatography is high-throughput. Analytical chemists working with rare organics or unstable intermediates need confidence in their solid phase. Feedback from these users guided us to optimize the 100µm range—ensuring minimal lot-to-lot variation, clean eluate, and no interference in spectral measurements. Over time, this approach has won repeat business from academic spin-outs and high-purity synthesis houses. One project purified organic photoinitiators for semiconductors, another tackled residual solvents in botanical extracts. In each, column reproducibility and low extractable background made our spherical silica the go-to choice.
Daily, we pursue more precise classification steps and better in-line monitoring of hydrolysis and agglomeration during gel synthesis. Defective particles equal direct customer complaints, and lost raw material cost. That’s why we re-invest in sieve upgrades, denser sampling, and staff retraining when needed. High-quality silica, once demanded only by a few, is now baseline for even routine commercial workflows. We log every production run and respond rapidly to off-spec trends. Customers who brought us “problem columns” in the past report markedly fewer issues since shifting to our production lots.
Silica gel, though chemically inert, does create dust and waste during use and disposal. In handling large quantities, especially for process purification, it’s crucial to minimize airborne dust—for both worker health and product integrity. We incorporated dust extraction at each packaging line, reducing incident rates among staff. On a larger scale, we’re working with downstream users to encourage collection and recycling of spent gel into construction materials. By tracking internal waste and studying used silica’s potential for reuse, we’re working to lower the product’s overall environmental footprint, a growing concern among newer labs and industrial partners alike.
Over the past decade, columns have grown longer and diameters wider as upstream loads increased. Many customers initially thought larger silica particles would solve pressure issues, only to deal with poor resolution or too-fast elution. Spherical 100µm gel has proven it can keep up with the drive for throughput, balancing backpressure with repeatable separation. We advise against shortcuts, like cutting corners on slurry formulation or skipping degassing, since those details scuttle runs faster than most realize. Our in-house R&D continues to optimize the spherical process, aiming for even narrower PSDs and increased mechanical strength.
Certifying every batch isn’t a paperwork exercise for us. Product documentation, from manufacturing records to purity analysis, helps customers in regulated industries meet their own compliance requirements. Over years, customers have come to rely on us for straightforward answers—not canned responses, but insight drawn from our daily experience. A technician running a plant-scale column wants troubleshooting support grounded in real lab work; we are always ready to share tips on column packing methods, recommended solvent pre-washes, or ways to regenerate spent silica for secondary uses. Those details aren’t just theory—they’re drawn from decades working with this same gel, in and out of columns, under different conditions.
R&D chemists, routine analysts, and industrial process managers repeat similar stories: sharp, reproducible peaks, few surprise pressure drops, and reliable performance over repeated cycles. We’ve even received unexpected photos—a well-packed column, a resolved chromatogram, or the “after” comparison following a switch from off-brand gel. Even more telling is the drop in complaint calls after switching to 100µm spheres. We believe direct, honest feedback gives us the clearest picture of our product’s real-world value. Long-term buyers know that occasional hiccups in production will be addressed openly—because we run our own lab columns with the same lots sold to customers, we have firsthand stakes in the outcome.
Synthesis challenges grow every year, driven by new pharmaceuticals, industrial catalysts, and specialty chemicals. To maintain relevance, we continually upgrade our production lines, both to support emerging standards and to keep pace with higher purity needs. Advanced analytics, trace-level impurity screens, and customer requests for custom-sized spheres push us beyond the basics. What started as a commodity ingredient now requires tight process integration, digital plant monitoring, and ongoing skill development for our operators. Listening to user trends, we’ve developed finer gradations and specialty blends for niche separations. Our aim remains direct: to provide a product born from real manufacturing experience, tuned to the daily realities of column chromatography in all its forms.