|
HS Code |
738122 |
| Product Name | Semicarbazide hydrochloride |
| Cas Number | 563-41-7 |
| Molecular Formula | CH6N4O·HCl |
| Molecular Weight | 111.55 g/mol |
| Synonyms | Carbohydrazide monohydrochloride, Semicarbazide monohydrochloride |
| Appearance | White crystalline powder |
| Solubility In Water | Freely soluble |
| Melting Point | 169-171°C (decomposes) |
| Storage Conditions | Store at room temperature, tightly closed, away from moisture |
| Boiling Point | Decomposes before boiling |
As an accredited Semicarbazide (hydrochloride) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Semicarbazide hydrochloride is supplied in a 25g amber glass bottle, labeled with product details, hazard symbols, and manufacturer branding. |
| Shipping | Semicarbazide (hydrochloride) is shipped in tightly sealed containers to prevent moisture exposure and contamination. It is typically packed according to regulatory standards for chemical safety, often using secondary containment. During transit, temperature and handling instructions are adhered to, ensuring the product’s stability and integrity until delivery. Shipping complies with relevant local and international regulations. |
| Storage | Semicarbazide hydrochloride should be stored in a tightly sealed container at 2-8°C (refrigerated), away from moisture and incompatible substances such as strong oxidizers. Store in a cool, dry, well-ventilated area, and protect from light. Follow standard chemical hygiene protocols, and ensure appropriate labeling to avoid accidental misuse or exposure. Always refer to the manufacturer’s safety data sheet for specific storage instructions. |
Competitive Semicarbazide (hydrochloride) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every day at our facility, semicarbazide hydrochloride makes its journey from the reactor to the finished product packaging. Over the years, our team has learned every nuance of this compound, which is also recognized in our technical circles by its chemical name, semicarbazide hydrochloride. You get a fine, off-white crystalline powder that dissolves easily in water, sometimes surprising new operators with just how quick that reaction is. Our material's model, often internally referenced as the HCl stable salt of semicarbazide, features a molecular formula of CH6N4O·HCl and a purity of 99% minimum by HPLC—the level you expect in pharmaceutical synthesis or analytic applications.
Unlike semicarbazide free base, the hydrochloride salt handles easier and stores longer. People new to this chemistry sometimes try to use the free base, facing trouble with moisture absorption and decomposition. The hydrochloride version stays solid and pure much longer, even on the shelf, and packs more tightly in drums and bags. This characteristic supports both safer logistics and less product loss.
Chemists often mention semicarbazide during discussions on intermediates for active pharmaceutical ingredients. The hydrochloride salt in particular has a well-defined melting point and much less dust than some generic grades seen elsewhere. Our plant runs in closed reactors to keep moisture out and minimize by-products. This approach ensures batches meet pharmaceutical clients’ strict standards. We use filtration under nitrogen and drying at carefully controlled temperatures, always keeping our focus on making sure residual solvents stay well below regulated thresholds. These details don’t always appear on inspection reports, but they directly affect the consistency of what ends up in your warehouse or R&D lab.
Before each shipment leaves, our in-house analysts run NMR, FTIR, and HPLC to spot any over-oxidation or off-spec peaks. Long experience taught us shortcuts never pay—cut corners now, and hours get lost later, tracking down off-color results in conversion steps downstream. Sometimes, labs using semi-refined grades from less disciplined plants think the difference won’t show up—until a condensation reaction fizzles or impurities cloud a chromatogram. Regular feedback from pharmaceutical synthesis runs and input from process chemists help us fine-tune each lot towards what actually works in your real-world processes.
Semicarbazide hydrochloride plays a direct role in the synthesis of a range of heterocyclic compounds, including triazoles and oxadiazoles. In our experience, customers focusing on uracil derivatives and hydrazones require chromatographic grades and extended stability. The hydrochloride salt offers exceptional compatibility with these reactions—the solid dissolves quickly to participate in condensation steps, while unreacted amounts get removed easily once the reaction finishes. Plant operators who tried shifting to non-salt (neutral) forms often return, citing poor shelf-life, slower dissolving, and costly cleanups.
Metabolite identification assays for pharmaceuticals rely on high-purity semicarbazide hydrochloride for hydrazone formation. Analysts aiming to detect α-dicarbonyl impurities in food packaging materials also prefer our stable-grade material. The purity of our product supports hitting LOQ levels in LC-MS or GC-MS analytics—one impurity at this stage can throw off entire analytical runs and waste expensive primary samples. We learned long ago that skipping one hands-on step in purification translates into wasted time later down the road.
Stability matters more than most people anticipate. Semicarbazide hydrochloride developed in uncontrolled workshops can show yellowing, excess moisture content, or caking after a few short months. Inside our plant, each drum gets triple-bagged and packed with desiccants, because a little care up front pays off for everyone later. Shipping departments appreciate knowing the material holds steady during transit, especially in high-humidity regions. Few things frustrate a QC chemist more than tearing open a fresh order only to find wet clumps or clinging fines.
Older product specs from previous decades sometimes allow up to 1% moisture—pharma-grade manufacturing can’t tolerate that anymore. Our modern grade comes in under 0.2% moisture, giving confidence to tableting or formulation staff. We work closely with partners to review shelf-life data and suggest repacking schedules based on ambient storage conditions. Experience shows storing in cool, dry rooms away from direct light gives the lowest risk for slow decomposition. Plant engineers who ignore this guidance soon face more paperwork due to out-of-spec internal audits.
Not all semicarbazide products come out the same. Some suppliers offer lower purity technical grades meant for industrial uses such as rubber accelerators or bulk dye intermediates. Those materials often contain unreacted hydrazine or carbonyl by-products that can ruin a pharmaceutical synthesis. Bulk chemical traders sometimes advertise “pure semicarbazide” at suspiciously low prices. We’ve tested those samples—HPLC traces reveal heavy tails, base discoloration, and poor solubility.
Offering only the hydrochloride variant with strict internal controls allows us to avoid legacy issues with contamination from free base versions. Researchers needing both chemical stability and minimal background reactivity consider the hydrochloride version—either as the main reactant or as a scavenger for problematic carbonyls in process streams. Labs using only analytical grade materials have come to trust the feel and look of a consistent batch from our plant. Our process avoids cross-contamination with other hydrazine derivatives, a lesson learned from facility upgrades and batch failure investigations early in our company history.
Our user base includes both scale-up teams in pharmaceutical plants and bench-scale chemists trying new routes in heterocycle chemistry. On several occasions, we’ve worked hand in hand with them, reviewing batch records to support successful DMF submissions or troubleshooting late-stage crystallization issues. We’ve seen big differences between lab-derived semicarbazide and that manufactured via continuous process under closed conditions. Quick filter color test in the lab might not reveal low-level aldehyde contaminants that later show up in precision synthesis, so having control over every step of the manufacturing process—from raw hydrazine to finished hydrochloride—provides real-world peace of mind.
Academic collaborations sometimes require custom batches—changing particle size distribution or drying times to support dissolved oxygen-sensitive reactions. Our engineering team regularly runs small pilot lots to accommodate such requests, learning each time how minute adjustments play out not only in analytic purity, but in hands-on downstream process performance.
Regulatory pressure continues to grow on all critical reagents, especially those used as key intermediates. Keeping clear of nitrosamine or other carcinogenic trace impurities in semicarbazide hydrochloride requires not just validated cleaning, but precise control throughout synthesis, washing, and packaging. After a string of high-profile recalls industry-wide for unrelated contaminants, we increased in-process controls and introduced redundancy in critical sampling points. Nobody wants to be caught by surprise when customers need analytical backups for regulatory filings or surprise audits.
To support the food analysis sector, purity thresholds have become ever tighter. We maintain dedicated QA review teams for lots intended for analytical work, knowing how even a minor deviation can ripple out into flawed research results or legal disputes. Customers in the food-packaging arena now send their own auditors to our plant to witness production and packaging—and seeing up close the differences that real process discipline makes. Some ask detailed questions about wastewater recovery, solvent recycling, and trace heavy metals. Being candid about the answers—good or bad—helps build long-term trust. In the rare event of a spec drift, our plant flags the batch, not the customer.
Our process didn’t reach its present state overnight. Every new solvent, reactor coating, or filtration grade represented hours of operator training, failed prototypes, or troubleshooting dead-ends. Newer staff benefit from the detailed batch logs compiled by process veterans, which record even minor formula modifications so learning accumulates across generations. The result is fewer unexplained outliers in testing and more robust product for every customer, whether prepping a 10 g research batch or a 500 kg commercial run.
Semicarbazide hydrochloride continues to attract attention across new segments. Biopharma groups exploring novel linker chemistry in ADCs have started to order high-purity lots from us, seeking out the hydrogen-bonding and nucleophilic features that define this molecule. Peptide cyclization specialists value the hydrochloride form, not only for purity but for low impurity profile—trace residuals left by hydrogen chloride in the synthesis are documented and tracked.
Operators oversee supply to dozens of destinations, from major pharmaceutical hubs to smaller sites in emerging markets. We’ve seen how product requirements shift rapidly depending on regulatory regimes. In Europe and North America, traceability and change control top the list—site audits and documentation requests arrive frequently. In other regions, users ask about scalable shipments, drum stability, or flexibility in loading patterns. We take pride in personally training logistics staff to avoid issues such as vibration-induced caking or inadvertent water ingress during overseas transit.
Academic and industrial clients alike often need to solve urgent sourcing issues for semicarbazide hydrochloride. Having direct lines to process managers on both sides allows us to quickly swap lot data, resolve spec clarifications, or propose substitutions for related derivatives—all without layers of distribution bureaucracy. From the plant floor, we see which paper specs turn into real world production hurdles and which simply reassure regulators. Every staff member learns that the true value of our semicarbazide hydrochloride isn’t only in certified purity—it’s in the history, adaptability, and transparency underlying every shipment.
The next generation of process improvements focuses on greener solvents, energy recovery in drying steps, and long-term minimization of hazardous by-products. Our R&D group works directly with synthesis engineers and regular plant operators to test run proposed changes—differences that look good on paper sometimes fall flat in scaled manufacturing. Every adjustment requires supporting data and traceable documentation. By keeping the entire team involved in process development, we prevent knowledge bottlenecks and protect against critical skills loss.
New demands continuously emerge. High-throughput analysis in clinical diagnostic labs now stretches demand for ever-cleaner semicarbazide hydrochloride, driving us toward advanced filtration and final-packaging protocols. Digital batch tracking supports ongoing queries and retrospective data reviews. Rather than chasing every trend, we focus on connections with users willing to share honest feedback about reaction performance, shelf-life, and end-application quirks.
Years of direct manufacturing experience shaped how we approach semicarbazide hydrochloride production. Our approach privileges process visibility and open communication from synthesis through packaging. Each employee—chemist, operator, packager—understands how the decisions made in our plant affect labs and factories half a world away. Regular on-site audits, live customer feedback sessions, and review of actual production records keep our routines sharp and aware.
Semicarbazide hydrochloride isn’t just another entry in a catalog. It’s a vital partner to many scientific breakthroughs in pharmaceuticals, analysis, and advanced materials. The subtle differences between grades—borne out of real production experience and customer-driven improvement—prove their worth every day, drum by drum. By sharing our journey with this critical intermediate, we hope to encourage continuous dialogue with every user, supporting each application with experience gained on the shop floor, one batch at a time.