|
HS Code |
979463 |
| Product Name | (S)-MOP |
| Iupac Name | (S)-(+)-2-methoxy-2-phenyl-1-propanol |
| Cas Number | 21871-47-6 |
| Molecular Formula | C10H14O2 |
| Molecular Weight | 166.22 |
| Appearance | colorless to pale yellow liquid |
| Optical Purity | typically >98% ee |
| Specific Rotation | [α]D20 +40° to +44° (c=1, CHCl3) |
| Boiling Point | 264-266 °C at 760 mmHg |
| Density | 1.057 g/mL at 25 °C |
| Refractive Index | n20/D 1.515 |
| Storage Conditions | store at 2-8°C, protect from light |
As an accredited (S)-MOP factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The (S)-MOP from Sigma-Aldrich comes in a 5g amber glass bottle with a screw cap and tamper-evident seal. |
| Shipping | (S)-MOP is shipped by Sigma Aldrich, Merck, or TCI in secure, sealed containers suitable for laboratory chemicals. Packaging ensures protection from moisture, light, and contamination. Transport complies with international chemical safety regulations, including labeling and documentation. Temperature control may apply; confirm specific conditions per manufacturer’s Safety Data Sheet (SDS). |
| Storage | (S)-MOP should be stored in a tightly closed container in a cool, dry, and well-ventilated area, away from heat and incompatible materials such as strong oxidizers. Protect from moisture and direct sunlight. Store at room temperature (typically 2-8°C if specified by the supplier). Follow all safety and handling instructions provided by Sigma Aldrich, Merck, or TCI Chemicals. |
Competitive (S)-MOP prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Here on the production floor, (S)-2-(Diphenylphosphino)-2′-methoxy-1,1′-binaphthyl—better known as (S)-MOP—remains a quiet revolution in our chiral phosphine range. Over more than two decades, formulas, glassware, and operators have adapted, but the guiding principle stays the same: build molecules that deliver on consistency and impact. Countless hands and thoughtful minds have shaped our process, ensuring that every batch of (S)-MOP shows optimal optical purity, defined stereochemical integrity, and low residual content. We're always targeting ≥99% enantiomeric excess and thorough impurity profiles, because labs and producers trust the work that goes into them for their own high-stakes syntheses.
Producing (S)-MOP is not a matter of just scaling up a published route. It's a chain of craft decisions, built from trial and error, scaled from bench to reactor, and kept steady by a genuine understanding of what each solvent, catalyst, temperature swing, or purification tweak does. Our current process relies on proprietary catalyst loading and precise protection/deprotection steps, tuned to minimize racemization and maximize throughput. Laboratories and commercial plants both demand reliability, so every key transition in the synthesis gets validated, and each final jar goes through quality assurance that runs deeper than checklists alone. It’s never about ticking boxes; it’s about being sure that the sample shipped out today will perform the chemistry tomorrow.
Chemists call on (S)-MOP for asymmetric catalysis, especially in transition-metal systems—rhodium-catalyzed 1,4-additions, asymmetric hydrogenation, or palladium-catalyzed allylic alkylation. Its binaphthyl framework and electron-rich phosphino group work together, turning up yields and selectivity in sterically demanding environments. Not every ligand supplies the balance of reactivity and chiral induction that (S)-MOP manages. Researchers and process chemists alike have used our material in synthesizing key intermediates for pharmaceuticals, agrochemicals, and even specialty fine chemicals, where regulatory scrutiny demands more than just “good enough” stereocontrol.
Our (S)-MOP typically comes as a crystalline off-white solid, stable to air in the short term but happiest inside a glovebox or under argon. Active ingredient content surpasses 98% HPLC area in finished lot reports. Water is ruthlessly excluded already at intermediate stages, and each production run checks for <50 ppm water by Karl Fischer titration. We notch above 99% ee by SFC or chiral HPLC, and batch COAs detail any relevant racemic byproducts or trace contaminants below 0.1%. Each drum and ampoule is sealed nitrogen-tight, but for customers needing more, we've proved low-peroxide and low-transition-metal packaging, reducing risks of degradation during transit or storage.
(S)-MOP stands apart from other chiral phosphines through both its molecular architecture and the learning embedded in every batch. Binap, for example, brings C2 symmetry and a different steric profile, showing its strengths in electronic tuning and certain hydrogenations but often missing the extra edge (S)-MOP brings in more hindered or electron-rich cases. (S)-Monophos and Trost ligands can excel in palladium chemistry, yet their backbone and oxygen tolerance limit their scope in some rhodium-catalyzed additions. In many situations, customers see higher enantioselectivities or distinct product ratios, not because the chemistry is radically new, but because small physical changes—like our method for ensuring tight control of methoxy substitution or mitigating trace oxidation on phosphorus—make the difference where others fall short.
Practical experience shapes our packaging and technical support as much as any specification. (S)-MOP resists ambient air better than some phosphines—helpful when weighing and charging it into gloveboxes or reaction vessels. Oxidation remains manageable if you keep it cool and dry, yet the solid will still degrade after days of exposure, so we ship smaller pack sizes for those who don't have inert-atmosphere hoods. Since real-world labs run into challenges—solubility mismatches, compatibility with glassware or PTFE, measuring down to single-digit milligrams—our technical staff pull samples from production to beta-test every new compatibility question. Sometimes, a solvent change on a kilo scale makes a batch come together, so our process and technical team try out common solvents across purity lots: THF, toluene, dichloromethane, and hexanes, giving detailed guidance when crystallization or slow charging is a concern.
We've scaled (S)-MOP from tens of grams to tens of kilograms on contract, with each volume jump teaching us something new. Small-scale lab practice rarely matches bulk production. Temperature control, agitation, and gas flow matter even more when purity targets and selectivity have no room for error. Years ago, small side-reactions started cropping up in higher-throughput glass reactors—those initially led to residual byproducts beyond 0.3%. So, we swapped to custom PTFE-lined reactors and re-optimized degassing steps, all based on what our distillation engineers, synthetic chemists, and QA staff saw day-to-day. Seeing purity outcomes in pilot lots and finished drums directly shapes the next run's protocols—there's always more to learn from the clash between design and actual practice.
No final downstream result matters if the ligand runs racemic or drops in selectivity batch over batch. Many users ask for certificates verifying >99% enantiomeric excess, but what matters almost as much is the stability of that performance across storage cycles, heat, or slight handling stresses. We routinely stress-test representative samples in-house: heating at 40-50°C, running dry-down and re-crystallization, testing for racemization or loss of resolution. If a batch drops below specification, we quarantine and investigate root causes—sometimes it's an upstream impurity missed by a supplier, sometimes an equipment maintenance issue. These are gritty, daily realities that shape how strictly we track everything from raw material orders to process logs and even lab notebook notations.
Some customers demand a different density of packaging, a special inertization procedure, or want to blend (S)-MOP into catalyst precursors before shipment. These requests come not from a textbook, but from years of accumulated field experience: how the ligands behave in their reactors, which trace trace metals matter for FDA filings, what documentation will pass muster under audit. Our technical support staff carry chemistry backgrounds and get hands-on with batches before advising on use cases. They’re in regular contact with plant managers and R&D chemists, revising SOPs and shipment practices in response to real-world data. If a project means testing a novel transition-metal precursor with our chiral ligand, we run and release those trials as a matter of course—sharing findings with both the customer and the development pipeline.
User innovation often happens outside our walls: new catalyst systems, process improvements, new product syntheses. We learn as much from clients bench-testing (S)-MOP in complex reactions as from any literature or patent scan. We track application examples across literature, industrial collaborations, and, informally, over phone calls with process chemists troubleshooting tricky transformations. One pharma client shifted from BINAP to (S)-MOP for a late-stage asymmetric hydrogenation, shaving significant waste from their process not through a change in reagent but because our material’s reliability allowed them to avoid a costly recrystallization step mid-synthesis. That case, and others like it, get fed back into how we document, produce, and support our ligands with each batch.
Standard procedures only tell part of the story. Every run, our operators log and monitor: reaction temperature curves, stirring speed, gas purity, exact weights, and chromatography outcomes. Deviations show up in real time, and corrective action flows from lived experience every time. Cross-training staff between analytical and production jobs builds both flexibility and accountability—detecting a drift in retention time or a color change mid-run gets flagged and fixed, not shuffled onward. Each lot carries a tangible history: who sourced the starting binaphthol, who set the key chiral crystallization, who pulled the analytical samples for purity and optical rotation. That continuity—knowing who to ask, what questions to pose, how to work “behind the numbers”—shapes outcomes more than specs on a page ever could.
Analytical machinery (NMR, LC-MS, chiral HPLC/SFC) tracks not just the final product but intermediates and side-products, accumulating a dataset that steers continual process adjustment. One production run showed an abnormal phosphorus impurity pattern on ^31P NMR—the investigation led to recalibrating a pump and tightening solvent spec, a fix only noticed by matching batch profiles side-by-side. Our files fill with performance data on both successful and nonconforming lots, which we use not just for compliance but for carving away long-term variability. For new users, we share representative chromatograms and spectra so in-house labs see what consistency really means, not just a line in a COA.
(S)-MOP’s shelf life often extends beyond two years if kept cool, sealed, and dry, though some customers finish their supply within weeks of delivery. We validate this through forced aging: storing test samples under light, heat, and moisture, then pulling out aliquots for performance checks in model reactions. Not every shelf-life chart lines up with a real-world, humid lab or long trans-Atlantic shipment. Our packaging includes oxygen scavenger sachets and secondary seals for longer hauls—a procedural step driven not by protocol, but by learning from clients whose material had sat through customs delays or unexpectedly warm warehouses.
Legislation around chemical traceability, waste management, and safety tightens the bounds of our practice. We document every key input lot number and maintain digital tracking through production and shipping, supporting many customers with extra compliance paperwork relevant for pharmaceutical or fine chemical chains. Waste streams are tightly segregated in production, processed for safe disposal or recovery, guided by known regulatory guidelines. Our staff handle and train with updated safety guidance, including new PPE standards and periodic third-party inspections. While the technical criteria for (S)-MOP stay chemical, the paperwork and stewardship now reflect broader accountability—the batch’s history doesn’t end at our gates, and clients expect as much documentation for stewardship as for stereochemistry.
(S)-MOP never races to the bottom on price. Raw binaphthol and diphenylphosphine have fluctuated sharply over past years based on supply and regulatory changes for core aromatic inputs; catalyst and solvent purity swings often dictate our own input costs. Energy consumption for low-temperature reactions (keeping chiral induction sharp) has real impact on cost per kilo at scale. Process tweaks—solvent recycling, de-bottlenecked purifications, in-line monitoring—feed back into keeping price steady, but the market recognizes the value of authentic, consistently high-selectivity material, ready to go batch after batch. For contract and repeat customers, sharing long-term forecasts helps us justify investment back into capacity, QA, and more thorough technical support.
As industry turns to more complex, multi-chiral center molecules and ever-tighter regulatory oversight, reliable ligands aren't a luxury. This isn’t just for big corporate campaigns; smaller labs developing new catalytic cycles or startup ventures pushing specialty compounds need the same high baseline. Our bulk (S)-MOP often fuels longstanding pharma targets, but the technical questions and support demands often come from the smaller or more agile customers—the kind open to creative experimentation and looking for a problem-solving partner more than just a shipper.
Our teams—synthetic chemists, engineers, QA specialists, and logistics partners—bring their own subject-matter insights and hard-earned troubleshooting skill to each shipment. Lab synthesis sometimes runs on autopilot, but full-scale production calls for daily flexibility: rinsing lines for cross-contamination, switching glassware to PTFE amidst supply shortages, hand-labeling drums so end-users get useful traceability. Each challenge, from sourcing through packaging, gets handled by a crew who take pride in clear outcomes and honest feedback. The reputation attached to every batch isn’t just the company’s name on the label—it’s the unseen hours and integrity behind every kilogram of (S)-MOP that reaches a customer’s receiving dock.
The demands on chiral ligands like (S)-MOP will only grow, as downstream syntheses expect even greater selectivity, lower residual metals, and tighter compliance for emerging pharmaceutical and specialty chemical markets. We keep investing in new purification tools, continuous-flow process screening, in-situ monitoring, and downstream analytics—tools shaped by feedback from those who see first-hand how ligands perform in unique transformations. Every kilo shipped tells a story that stretches beyond raw material sourcing or price points: it’s the accumulated lessons, constant feedback, and hands-on care from production line to application. For any chemist or process engineer working with (S)-MOP, that reality shows up not in marketing claims, but in real performance, batch after batch, synthesis after synthesis.