HS Code |
598306 |
| Chemical Name | (S)-(+)-Camptothecin |
| Cas Number | 7689-03-4 |
| Molecular Formula | C20H16N2O4 |
| Molecular Weight | 348.36 g/mol |
| Appearance | Light yellow powder |
| Purity | Typically ≥98% |
| Melting Point | 269-271°C (dec.) |
| Solubility | Slightly soluble in DMSO, methanol, and ethanol |
| Optical Rotation | [α]D +18° (c=1, DMSO) |
| Storage Temperature | 2-8°C (refrigerated) |
| Iupac Name | (S)-4-ethyl-4-hydroxy-1H-pyrano[3',4':6,7]indolizino[1,2-b]quinoline-3,14(4H,12H)-dione |
As an accredited (S)-(+)-Camptothecin factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | (S)-(+)-Camptothecin, 25 mg, Sigma Aldrich: Supplied in a sealed amber glass vial with chemical label, desiccant, and lot information. |
| Shipping | (S)-(+)-Camptothecin is shipped in tightly sealed, light-resistant containers to preserve its stability. Transport is done under controlled, cool conditions, and in compliance with chemical safety regulations. Appropriate hazard labels and documentation are included to ensure legal and safe domestic or international delivery. Only authorized recipients may accept the shipment. |
| Storage | (S)-(+)-Camptothecin should be stored in a tightly sealed container, protected from light and moisture, ideally at -20°C in a dry, well-ventilated chemical storage area. Avoid repeated freeze-thaw cycles. Handle under an inert atmosphere if possible, as the compound is light-sensitive and may degrade upon prolonged exposure to air or humidity. Follow all safety guidelines and local regulations when storing. |
Competitive (S)-(+)-Camptothecin prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Decades in chemical synthesis have taught us that even a single stereocenter changes everything. (S)-(+)-Camptothecin stands as an example. We manufacture this compound in crystalline powder form, favoring rigorous purification and strict optical resolution to ensure a chiral purity exceeding 99%. That level of attention isn’t only about quality certificates – it comes from a deep respect for what researchers demand. The right-handed (S)-enantiomer of camptothecin has become a benchmark for teams working on DNA topoisomerase I inhibition, leading not just to lab outcomes but discoveries that touch clinical practice.
Our standard manufacturing batch runs from milligram quantities to pilot-scale multi-kilo lots, with the HPLC and NMR spectra to support each synthesis. Each lot meets assay requirements of 98% or above by HPLC and has residual solvent profiles reflecting pharma-grade practices. Moisture and impurity controls aren’t checklist items for us; over the years we’ve seen how minute water content or trace side-products can undermine reproducibility. That’s the sort of issue that takes time away from your research milestones.
Anyone who’s tried to work up a purification of camptothecin derivatives knows: every source material tells its own story. Lab notebooks are full of frustration from users who turned to bulk intermediates with poor optical clarity or inconsistent melting points. Our process grew out of problems like these. We characterize (S)-(+)-Camptothecin for polymorphic form, solubility profile in typical solvents (DMSO, methanol, pure acetone), and compatibility with downstream reactions. Direct communication with secondary synthesis teams shapes each step—feedback about yields, unexpected by-products, or solubility quirks doesn’t get lost in translation.
Some manufacturers use aggressive drying or crude isolation in rush to meet tight deadlines. We focus on stepwise precipitation, low-temperature solvent removal, and vacuum desiccation. This habits come from seeing what happens when residual traces cause bioassays to deviate or batch results to drift over time. Our controls for trace metals, residual silica, and carryover organic impurities grow out of feedback from years of downstream enzymatic and cell-based assay partners.
What comes out of our facility isn’t just bulk (S)-(+)-Camptothecin. Our preparation shows consistent color (off-white to faint yellow), micron-level crystalline grain size, and high batch-to-batch uniformity in both purity and chiral excess. Analytical verification using polarimetry, mass spectrometry, and classic melting point comparison provide peace of mind, reducing calls from researchers puzzling over odd melting ranges or unexplained NMR peaks.
It’s easy to underestimate how small differences in optical purity or contaminant profile can influence how (S)-(+)-Camptothecin performs in your work. Over time, we’ve seen that even low levels of the R-enantiomer or degradants like hydroxycamptothecin create noise in biological data. While some generic sources focus only on overall camptothecin content, we check for a complete absence of epi-camptothecin (the R-form), following up with enantiomeric excess determinations post-synthesis.
Both the academic and R&D communities have shown a sharp rise in interest for the S-enantiomer’s activity in DNA breakage and cell cycle arrest models. In screening libraries, minor soluble impurities skew IC50s and add troubleshooting steps that slow progress. We have worked closely with teams developing new analogs, often troubleshooting together when batches failed because of overlooked contaminants or subtle crystallinity differences. Sharing our full analytical datasets with end-users builds confidence, so teams can rely on data from their controls, not just our word.
Extraction of total camptothecin from Camptotheca acuminata bark isn’t new. We respect those traditions, but extraction seldom meets the purity, yield, or optical clarity needed by today’s research-grade standards. That led us to focus on total synthesis and semi-synthetic pathways using well-documented chiral auxiliaries or asymmetric catalysis. This direction also gives us freedom from natural variability—something that plagued early users, who found bioactivity fluctuated batch by batch due to uncharacterized natural impurities.
Markets have been flooded over the years with total camptothecin, racemic forms, and sometimes inadequately resolved material. We find that researchers turning to (S)-(+)-Camptothecin look for the most biologically relevant material—the natural S-form, known for superior DNA relaxation inhibition compared to the racemic mixture. Our data over years show consistent strength at inhibiting topoisomerase I-mediated cleavage, without background activity from the less active or counterproductive R-enantiomer.
As biomedical and pharmaceutical research shifted, we found ourselves moving from small-batch custom orders to standardized supply lines for screening campaigns and even for advanced preclinical development. Our refined purification steps enable smooth, scalable access—always with certificates accompanying each shipment, outlining both chemical and chiral purity, and all relevant detection limits for key byproducts.
(S)-(+)-Camptothecin keeps finding its place across a range of experimental models. Workhorse assays in genomics, oncology, and enzymology all benefit from the reliable inhibition and clean reactivity profile that our material delivers. Newer work with antibody-drug conjugates and targeted prodrug scaffolds lean on the high reproducibility of both chemical structure and physical form. Partnering with developers in these fields, we often adapt our specifications—such as certain preferred hydrate forms or particle sizes—based on their assay feedback or downstream process needs.
Each kilo of (S)-(+)-Camptothecin going out our doors reflects adjustments from decades of customer feedback. Early on, users pointed out solubility challenges in aqueous systems. We responded by mapping particle size distribution and surface area, finding a sweet spot in crystallization conditions to aid both dissolution and downstream modification. That experience informed our later process optimization, minimizing particle agglomeration without introducing unwanted excipients.
Transfer of (S)-(+)-Camptothecin into pharmaceutical intermediates (like irinotecan and topotecan) reveals the importance of a clean starting point. At the plant level, we often see failed derivatization reactions traced back to off-types or oxidized material from other sources. A tightly managed supply chain, in-house stability testing, and real-time analytics mean our batches avoid these pitfalls.
Feedback loops with the biomedical community have helped surface another issue: stability under ambient versus refrigerated storage. Camptothecin is notorious for lactone ring hydrolysis, and we’ve dialed in our moisture control based on endpoint bioactivity. Maintaining the closed-ring structure isn’t a luxury here; it’s the enabler for true biological relevance and successful repeat assays. Over time, teams working on slow-release and encapsulated dosage forms have requested varied crystal morphologies and particle sizes, which we provide by adjusting crystallization solvents, cooling rates, and drying protocols.
Beyond the (S)- and (R)-enantiomers, the market shifts with cheap synthetic and poorly resolved racemates. We don’t chase the lowest cost per gram. Our goal is to provide a workhorse (S)-(+)-Camptothecin that performs predictably, with well-characterized physical, chemical, and optical properties. Teams coming to us after working with generic sources report clearer results in cell lines and reduced background in mechanistic studies. Faced with ambiguous data, they’ve voiced appreciation for knowing every batch tracks back to a consistent synthesis and rigorous chiral resolution.
We maintain open communication about lot-to-lot variation. Years ago, we adapted our process after a top-tier customer detected sub-visible particulates affecting high-throughput screening consistency. Following their findings, we adjusted filtration steps, even though “out of spec” batches never shipped. The changes improved clarity and injection reliability for all users. Our synthesis pathway doesn’t introduce carrier salts or residual bases that could complicate downstream reactions—unlike some bulk intermediates or knock-off suppliers.
It’s one thing to supply small vials for bench experiments; it’s another challenge to fill large-crystal requests or pilot-scale lots for a CRO gearing up for GLP runs. Scaling up isn’t only about more reactors or bigger filter plates. Reliable scale-up means every milligram in a larger batch mirrors the chemical and chiral profile of our smallest research sample. We invest heavily in process controls—real-time analytics, solvent reclamation, and continuous training for every staff member involved. Hard-earned experience tells us: downstream reproducibility only happens with careful upstream management.
Questions come in from polymer scientists exploring camptothecin release matrices, biotechnologists investigating new anticancer conjugates, and pharmacologists validating fresh targets. The common thread is a demand for both chemical clarity and absolute consistency. We see value in adapting, whether it’s providing particle-size matched batches, ultra-low endotoxin lots, or custom packaging to avoid static clumping.
Quality systems in our shop go beyond off-the-shelf ISO checklists. Our line staff meet face to face with both quality control teams and process chemists; feedback doesn’t get lost in bureaucracy. User experience keeps shaping our protocols for labeling, documentation, and physical stability. Storage systems are chosen for maintaining the material’s active lactone form, often with desiccant or nitrogen blankets based on the time needed for transit and warehouse storage.
Confidence in our (S)-(+)-Camptothecin comes from more than test results. We run cross-checks against the reference standards from major pharmacopeias, and continually update protocols based on chemical literature and new assay technologies. Changes in analytical methodology—high-res mass spec, upgraded polarimeters, or new impurity LCMS libraries—drive continuous improvement in both detection and lot release criteria. Rather than waiting for problems to appear downstream, we proactively model and mitigate risk points based on decades of hands-on process chemistry.
Supplying (S)-(+)-Camptothecin involves trust—teams bet their research dollars and reputations on our manufacturing insight. We share safety notes, handling tips, and troubleshooting guides with each shipment. Sometimes, order follow-ups become troubleshooting sessions for process improvements both for us and the users.
The needs of medical and scientific research push us to higher accuracy, not just higher throughput. If a customer reports odd color, solubility variance, or unusual results in topoisomerase assays, we pounce on root causes, collaborating openly about findings. Years responding to such feedback led us to refine filtration, adjust vacuum-drying, or improve packaging and shipment method—because the real-world lab experience counts as much as any specification document.
In-house, we repeat every synthetic campaign with lots of record-keeping. Experienced chemists know cutting corners in process control only invites problems—so we invest in fresh staff training and regular review of GMP and analytical best practices. Meeting and exceeding industry benchmarks starts at the level of daily batch logs, not post-facto spot checks.
Sourcing knowledge from users in the field keeps us honest. Over the years, suggestions from lead scientists, process engineers, and bench researchers informed almost every protocol we follow. Sometimes the best improvements didn’t come from market surveys or certifications but from an email with attached chromatograms and late-night notes on how a batch performed in a new bioassay.
Supplying (S)-(+)-Camptothecin is both challenge and privilege. With our routine syntheses, attention to the smallest details, and responsiveness, our product escapes the “commodity” label. Teams using it for sensitive assays, scale-up studies, or pilot plant development count on our close control from bench top to packaging. The drive toward rigorous reproducibility and scientific accuracy runs through everything we do, making our facility stand out as a trusted partner for advanced research and innovation.