HS Code |
263668 |
| Product Name | Pentafluoropropionic Acid (ca. 0.5mol/L in Water) [Ion-Pair Reagent for LC-MS] |
| Chemical Formula | C3HF5O2 |
| Molecular Weight | 166.03 g/mol |
| Concentration | approximately 0.5 mol/L |
| Solvent | Water |
| Appearance | Colorless to pale yellow solution |
| Density | 1.68 g/cm³ (for pure acid) |
| Boiling Point | 92°C (pure acid, at 1013 hPa) |
| Cas Number | 422-64-0 (for pure acid) |
| Purity | Typically prepared from high purity reagents for LC-MS use |
| Application | Ion-pairing reagent for liquid chromatography-mass spectrometry (LC-MS) |
| Storage Temperature | Store at 2-8°C |
| Ph Value | Acidic (exact pH depends on concentration) |
| Synonyms | 2,2,3,3,3-Pentafluoropropanoic acid; PFPA |
| Hazard Classification | Corrosive (for pure acid) |
As an accredited Pentafluoropropionic Acid (ca. 0.5mol/L in Water) [Ion-Pair Reagent for LC-MS] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Pentafluoropropionic Acid (ca. 0.5 mol/L in Water), 100 mL, supplied in an amber glass bottle with secure screw cap. |
| Shipping | Pentafluoropropionic Acid (ca. 0.5 mol/L in Water) for LC-MS is shipped in secure, leak-proof containers, compliant with chemical safety regulations. Packaging includes appropriate hazard labeling, documentation, and cold packs if required to maintain stability. Transport adheres to all applicable DOT, IATA, and carrier guidelines for corrosive liquids. |
| Storage | Store Pentafluoropropionic Acid (ca. 0.5 mol/L in water) in a tightly sealed, chemically resistant container, in a cool, dry, well-ventilated area away from incompatible substances such as bases, strong oxidizers, and reducing agents. Avoid exposure to direct sunlight and moisture. Ensure proper labeling and use secondary containment to prevent leaks or spills. Follow local regulations and institutional safety protocols. |
Competitive Pentafluoropropionic Acid (ca. 0.5mol/L in Water) [Ion-Pair Reagent for LC-MS] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Standing in the factory, the distinct sharpness in the air always reminds me we are making something impactful for laboratories worldwide. Pentafluoropropionic acid—especially in its hydrated state at ~0.5 mol/L—serves a unique purpose for LC-MS professionals. At this concentration, you get a strong ion-pair reagent, ready to meet the exacting standards of analytical chemistry workflows. Each batch reflects a balance between chemical reactivity and straightforward usability.
In the real world, manufacturing a fluorinated acid like this doesn't start or finish with a simple recipe. The journey, from sourcing the right precursors to reaching a pure, shelf-stable solution, involves layers of chemistry, risk management, and hard-earned expertise. Our facility uses closed-loop systems to minimize airborne acid and prevent material loss. Constant inline monitoring makes sure the acid strength stays consistent, so each order matches the strict spec every single time.
People often ask what makes pentafluoropropionic acid stand apart from standard carboxylic acids or more mild ion-pairing additives. We see the practical differences under the hood. Its heavily fluorinated structure provides stronger ion-pairing efficiency compared to trifluoroacetic acid—especially when working with basic analytes and peptides. In chromatography labs, that means sharper peaks, clearer separations, and more reproducible results. For compounds prone to tailing or ghosting, this reagent lifts out better-resolved data, even with complex sample matrices.
In terms of volatility, pentafluoropropionic acid sits in a valuable middle ground. It doesn’t linger as stubbornly as some long-chain analogues, which can choke up HPLC and MS interfaces if left unchecked. The acid helps users avoid baseline noise issues, streamlining mass spectrometry sessions in both pharmaceutical and environmental labs. Our in-house chemists have tested both freshly prepared and aged solutions and the 0.5mol/L formulation stays stable, as long as the standard storage precautions are followed.
Our choice comes from feedback on the practicalities of lab handling. Higher concentrations complicate dispensing and bring extra hazards; lower concentrations lack the punch professionals demand when working at the limits of detection. Over years supplying to both global labs and young local research institutes, we returned again and again to this near-half-molar mark for its consistency and workflow flexibility.
Preparing the solution directly in water guarantees rapid solvation and integration into mobile phases. We draw on direct feedback from LC-MS operators who need a reagent that is ready-to-use but remains consistent down to the last milliliter. Unlike dry-packed acid—which requires precise weighing and risks static pull-off losses—our pre-formulated solution skips steps and minimizes exposure risk, since evaporation can cause not just yield losses but health concerns.
Getting to a product that meets both regulatory expectations and end-user satisfaction requires control over many fine points. Working at scale, the way pentafluoropropionic acid reacts with water isn’t always forgiving. The acid’s reactivity toward metals means we avoid iron or steel wherever possible in our lines; glass or PTFE serve as the backbone for our blending tanks and transport lines. Regular checks for iron content aren’t a bureaucratic hoop—they’re a commitment to our client’s analytical signals remaining sharp and free from metallic contamination.
Purity is not something we chase in the abstract, either. For each production run, we examine the residual moisture, target acid content, and track any byproduct signals. Our analytical QA, built through years of responding directly to client troubleshooting requests, extends beyond a simple certificate. We check for low-level halogenate impurities, since even trace contaminants can have broad consequences in sensitive workflows. A customer running trace-level metabolite screens catches even the faintest off-peak, so maintaining the intended profile—high purity, without hidden fluorine or oxygenated byproducts—matters for every run.
There’s plenty of noise in the marketplace about what makes a good ion-pairing agent. Inside our operation, we’ve run head-to-head challenges using pentafluoropropionic acid, trifluoroacetic acid, and heptafluorobutyric acid in common LC-MS assays. Our technical staff see that longer-chain acids deliver even stronger ion-pairing but risk surface "memory effects" that cause backgrounds to persist between sample runs. The heaviest fluorinated acids often leave persistent residues within the ESI interface, robbing users of throughputs and clarity.
Trifluoroacetic acid, lower on the fluorination scale, brings some volatility and is easier to clear—yet doesn’t always provide the selectivity and retention needed for advanced peptide or metabolite workflows. From practical experience, pentafluoropropionic acid delivers a solid balance: enough retention modulation and selectivity without building up in fluidic systems or mass spectrometry interfaces. We configure our concentration to let labs tune their method without overhauling injector programming.
Any technician refining gradient methods for LC-MS knows the value of reliable, steady acid strength. Our pentafluoropropionic acid formulation slots right into existing methods, allowing teams to focus more on analytical challenges than fiddling with preparative steps. The acid’s high purity and ready-to-mix nature eliminate troubleshooting at the solvent prep stage. For teams running batches over long shifts, less downtime for line clearing means more samples processed per day and fewer error flags stemming from acid breakdown or inconsistent concentration.
One often overlooked advantage: this acid’s moderate pKa and high electron-withdrawing capacity mean cleaner detection for a wide range of amines, nucleosides, and complex heterocycles. We’ve helped pharmaceutical research teams move beyond conventional acids, achieving both improved signal-to-noise and less detector fouling on extended studies. Because our product rides the line between volatility and retention, it adapts well to routine screening as well as exploratory metabolomic profiling. The reduced background in the MS reads as more consistent data batches and fewer system washes.
Sourcing and working with a strong fluorinated acid is not for the inexperienced. We remind users that even at moderate concentrations, the fuming risk and corrosivity remain, so personal protective equipment and good ventilation must stay at the forefront. We have invested in drum and bottle closures with vapor-reducing features to lower exposure when opening and dispensing. Each lot is supplied with technical support advice collected from decades of direct feedback—not scripted safety lines, but practical instructions on storage, transfer, and neutralization.
In our own facility, training for safe handling runs alongside chemical production. Our staff recognize that familiar routines can hide small changes in behavior or equipment health, so we reinforce routine safety audits and cross-check each station after long batch runs. These lessons carry into the field, as we often provide direct support to customers ramping up new analytical lines. Building a relationship means troubleshooting together on process changes—if a client starts seeing unexpected tailing or background rises, it helps to have a manufacturer who has truly seen the processes at production scale.
Staying close to the production floor, we notice small variables—ambient humidity spikes, temperature drifts during blending, or subtleties in water sourcing—that can nudge product quality over time. Our process engineers tune batch schedules to adjust for these seasonal and operational quirks. This level of care reflects a philosophy begun years ago, when minor reactivity shifts resulted in avoidable spoiled stock and frustrated researchers.
We run our own LC-MS validations before any shipment leaves the site. Direct feedback from our own instrument team provides insights on flow rate tolerance, gradient compatibility, and signal performance across a range of columns. Each quality control run is influenced by real-world user reports—those “outlier” results that often flag system-level bugs more clearly than routine specs ever could. Through hands-on practice, we keep the focus on the acid’s performance—not just as a chemical, but as a trusted analytical partner.
Behind every high-quality LC-MS result, there is a web of operational decisions, instrumentation care, and—often overlooked—choices in mobile phase reagents. It’s rewarding to see research teams tackle novel drug candidates, environmental studies, or clinical biomarkers with confidence, knowing their acid source streamlines their operations instead of holding them back. Our drive, as a manufacturer, is rooted in these collaborative successes: every clean batch and well-resolved chromatogram traces back to the time spent fine-tuning both chemistry and handling experience.
Discussions with global customers have opened our eyes to how this acid plugs into emerging trends—automated liquid handling, microvolume analytics, and tighter regulatory oversight on laboratory reagents. In response, our batch documentation and traceability systems go beyond standard practice. When a regulator or a lab auditor demands proof, we reach into archives of real user performance data, batch histories, and corrective action notes built on hands-on knowledge. This isn’t an abstract “commitment to quality”—it’s concrete evidence, available upon request, from people who know why every test matters.
The lab world does not stand still, and neither does our process. Feedback loops between users and manufacturers run quickly. Analytical chemists now want reagents that integrate seamlessly with advanced LC-MS hardware, shorter run times, and higher reproducibility. Our own R&D team works arm-in-arm with product engineers to monitor field failures, check real chromatograms, and design pilot runs for special projects.
For example, early-adopting research groups pressured us for more robust packaging to avoid uptake losses during shipment, especially for humid tropical regions. Investments flowed into upgraded container linings and off-gassing controls—small features that keep the acid’s profile steady from loading dock to laboratory bench. These experiences, taken from real orders and direct user complaints, shape each incremental product development.
Consistent product means fewer calibration failures, less need to filter or condition solvent lines, and fewer operational surprises. For contract research groups, this translates into delivered reports without unnecessary repeats. The acid’s performance, batch after batch, determines a lab’s ability to publish, meet contract deadlines, and trust their instruments’ baseline. We see our role as a quiet enabler—providing a platform of reliability so others can innovate at the analytical frontier.
Some might overlook this acid as “just another” consumable, but to us, its performance and purity illustrate the trust shared between technician and manufacturer. We’re measured not just by what leaves our doors, but by how well it performs in demanding, real-life labs chasing difficult molecules at vanishingly small concentrations.
Handling and disposing of fluorinated acids draw scrutiny from both regulatory agencies and conscientious lab managers. We engage with these concerns on the shop floor and in technical support calls every week. For years, we have reduced reprocessing waste through in-house solvent recovery and acid neutralization, offering this knowledge to users seeking greener operations.
By encouraging centralized acid purchase and distribution within multi-user laboratories, we have helped clients limit reagent waste, reduce exposure events, and stretch operational budgets further. Flask-by-flask, process changes matter as much as the reagent quality itself. We take pride in working together to close gaps in safe use and reduce the environmental footprint that can sneak up on the busiest research teams.
Pentafluoropropionic acid at 0.5mol/L may sound like a simple bottle on a shelf, but behind it stands the sum of manufacturing discipline, years of laboratory support, and a constant chase for progress. Real-world challenges—shifting regulations, ambitious research deadlines, and unique instrument quirks—have shaped the way we craft and supply this reagent. Every step, from bulk handling to careful quality release, focuses on what matters most: providing an acid that delivers predictable, repeatable results in the hands of demanding LC-MS professionals.
We stand with our clients in the pursuit of better science. Lab after lab, run after run, pentafluoropropionic acid in water 0.5mol/L has shown its worth. It is more than a tool—it is a silent but critical partner in the race for insight, discovery, and answers that matter in the real world.