|
HS Code |
743187 |
| Product Name | Palbociclib (monohydrochloride) |
| Cas Number | 827022-32-2 |
| Molecular Formula | C24H29N7O2·HCl |
| Molecular Weight | 482.01 g/mol |
| Synonyms | Ibrance monohydrochloride, PD 0332991 HCl |
| Appearance | White to off-white solid |
| Purity | ≥98% (HPLC) |
| Storage Temperature | 2-8°C |
| Solubility | DMSO, water (sparingly), ethanol |
| Mechanism Of Action | CDK4/6 inhibitor |
| Application | Anticancer agent, research chemical |
| Target | Cyclin-dependent kinases 4 and 6 |
| Brand Name | Ibrance |
| Melting Point | Approximately 276-278°C |
As an accredited Palbociclib (monohydrochloride) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Palbociclib (monohydrochloride) is supplied in a 100 mg amber glass vial, sealed, with a Sigma-Aldrich label and product details. |
| Shipping | Palbociclib (monohydrochloride) is shipped in tightly sealed, chemical-resistant containers, typically at ambient temperature. For longer transit or warmer climates, cold packs may be included to prevent degradation. The shipment complies with relevant chemical regulations and includes appropriate safety labeling and documentation in accordance with Sigma-Aldrich, Merck, or TCI standards. |
| Storage | Palbociclib (monohydrochloride) should be stored at -20°C in a tightly sealed container, protected from light and moisture. Ensure storage in a dry, well-ventilated area, away from incompatible substances. When handling, use appropriate personal protective equipment (PPE). For laboratory use only; follow institutional safety guidelines and refer to the manufacturer’s Safety Data Sheet (SDS) for additional information. |
Competitive Palbociclib (monohydrochloride) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every day in our facility, the production of palbociclib (monohydrochloride) demonstrates the combination of science and careful control. On paper, palbociclib looks like a typical small-molecule inhibitor, tasked with supporting treatment regimens for hormone receptor-positive, HER2-negative advanced or metastatic breast cancer. In practice, the demands of making a molecule of this complexity bring a level of precision that affects every corner of our operation.
Palbociclib’s chemical model, C24H29ClN8O2·HCl, barely hints at the process work involved. The structure, a cyclin-dependent kinase (CDK) 4/6 inhibitor, incorporates both aromatic and heterocyclic rings. These features mean our team must keep reaction conditions exact, avoiding trace impurities that would compromise activity or stability. Minor deviations in moisture levels, reagent charge, or even the calibration of measuring tools can throw a synthesis off course, creating byproducts that are hard to purge in downstream processing.
Scaling any kinase inhibitor, palbociclib included, moves beyond theoretical bench chemistry. Achieving multi-kilogram lots with consistent quality has taken years of tweaking and tight process parameters for every stage — from individual reaction steps to purification and drying. Each batch demands a strict purity threshold, often greater than 99 percent, with HPLC, NMR, and LC-MS data for every lot. Moisture content, specific rotation, and residual solvent levels get measured in real time, not just at QC sign-off. Our plant’s experience shows that attempting shortcuts or relaxed monitoring quickly leads to off-spec material. We’ve tested different crystallization solvents and found even seemingly minor changes — like residue from a previous batch — can affect particle formation or solubility.
In production, we work with the monohydrochloride form. This offers a good trade-off between chemical stability and biological compatibility. Products made as a free base, by comparison, can degrade more quickly or give variable performance in finished dosage forms, since they don’t always dissolve or disperse as well in water. The monohydrochloride salt brings a tighter range of pH during drug product formulation, reducing worries about hydrolysis or pH drift over time.
Years ago, before the widespread adoption of targeted inhibitors like palbociclib, our focus centered more on bulk actives and off-patent drugs. The introduction of CDK4/6 inhibitors changed this environment. Tiny shifts in impurity profiles can spell the difference between life-changing therapy and a failed lot. Patients receiving these drugs find themselves relying on lots we produce at plants like ours. A single error in pH adjustment, filtration, or cleaning can affect purity or stability.
For palbociclib, tight control over related compounds matters even more because impurities can include compounds structurally similar to the parent drug. Standard chromatography may not fully resolve these. Our analytic chemists watch for tiny peaks in LC traces, testing against carefully qualified reference standards we’ve produced ourselves. This constant vigilance isn’t about red tape; it comes from direct experience: outliers in crystal habit, shifts in polymorph distribution, or environmental contamination have all once triggered reviews and procedural upgrades in our lines.
While commercial pharmaceutical companies formulate palbociclib into capsules or tablets for patient use, our work stops at the production and quality confirmation of the API. Most lots see use in solid oral dosage forms, with a preference for dry, free-flowing crystalline material. Microbiological standards, absence of heavy metals and solvents, and reproducibility lot-to-lot become the backbone of every shipment. From a manufacturing perspective, a single out-of-spec polymorph or unidentified trace impurity can halt supply to the market. This is especially relevant in the oncology field, where patients face therapy interruptions waiting for compliant material.
Palbociclib monohydrochloride’s handling requirements stay strict from the weighing of starting materials to final packaging. We maintain batch segregation, specialized air handling, and cross-contamination controls. Every drum or container ships sealed with tamper-evident closures; before filling, our operators perform visual and chemical checks using spectroscopic techniques. Temperature and humidity controls stay in place during storage and shipping to maintain stability and reduce hydrolytic risk, avoiding any shift in appearance, particle size, or chemical content. We have observed that minor deviations in storage can manifest as increased moisture content, lower dissolution rates in drug product testing, or loss of color stability — outcomes flagged during both in-house and third-party audits.
Manufacturing palbociclib monohydrochloride does not follow the same rules as less sensitive APIs or those without intricate regulatory frameworks. While bulk antibiotics or simple analgesics tolerate greater residual solvents or wider particle size ranges, palbociclib requires narrow bands for every key trait. The regulatory submissions for these targeted therapies mean that every data point, from elemental analysis to impurity fingerprinting, must link to a validated process narrative. Inspections from auditors focus on the full production chain, so improvements in traceability and digital batch records evolve directly from our history fielding these reviews.
Other CDK4/6 inhibitors, such as ribociclib or abemaciclib, have differing solubility and stability characteristics in their salt forms. Their synthesis demands tweaks to temperature, solvents, and work-up conditions. Our work with palbociclib monohydrochloride, which stems from years of process development and observation in partner plant audits and international filings, highlights these distinctions. For instance, the tendency of palbociclib to take up moisture can surpass that of the free base or ribociclib chloride. That means every kilo created in our plant reflects the echoes of dozens of trial runs, each teaching us more about minimizing unwanted isomers, solving for scale-up bottlenecks, or combating humidity creep during packaging.
In the earliest years producing kinase inhibitors, raw material variability and tricky intermediates routinely resulted in off-spec lots. Our team learned the importance of qualifying not just the API but the entire process: incoming solvents, cleaning agents, and equipment loads. We now focus on closed process trains where possible, micro-dosing of catalysts, and real-time analytical controls. Palbociclib’s chemistry punishes complacency; a batch may pass initial chemical testing yet fail to deliver on physical properties such as flow, compressibility, or dissolution if upstream steps missed their mark by even a fraction.
One persistent challenge in our plant relates to the control of environmental variables. Humidity, temperature, and even airborne particulates impact this product. Each step, from wet-milling the crude product to controlled recrystallization, builds toward the product’s performance in solid dose manufacturing. Our engineers implemented tight-filtration units and secondary containment after discovering how easily open systems let through trace moisture and solvent vapors. Granule control, even in final drying, remains key, with operators trained to recognize clumping, color change, or unusual particle size as flags for further investigation.
Oversight doesn’t end with batch release. Ongoing stability monitoring guarantees that no lot falls short of shelf-life or storage stipulations. Palbociclib monohydrochloride draws regular audits from global regulators along with critical innovators. Batch production remains visible in real time through data loggers, environment monitoring, and digital trace files. These historical records confirm lot integrity years after delivery, delivered not to satisfy bureaucracy but to ensure material delivered for oncology projects is genuine, traceable, and safe.
From the manufacturer’s perspective, this documentation-intensive regime brings both reassurance and burden. Every new impurity, discovered during forced degradation or accelerated storage, brings rapid process review and corrective training. Our in-house teams revalidate entire steps if a new contaminant or a decline in purity appears. This culture reflects not just regulatory pressure but a shared recognition of the clinical risk — cancer patients waiting for treatment can’t accept undependable supply.
Direct comparison with other pharmaceutical APIs reinforces palbociclib’s specific challenges. Where some actives forgive short lapses in cleaning or recycling of solvents, palbociclib’s chemistry demands pristine conditions, traceability to the gram, and controls on nearly invisible contaminants. It’s common in our manufacturing to dedicate segments of the production suite to palbociclib work exclusively. This separation, rarely so strict for generics, aligns with client and regulatory demand that every container shipped out carries a full history of handling, storage, and verification.
Attempts to streamline processes, for instance adopting generic filtration units or standard dryers, have faced setbacks due to the unique properties of this molecule. Niche solvents, unusual crystallization temperatures, and anti-static measures in packaging have all come into play. The investment in specialized containment and sensors, or double sets of cleaning validation, traces directly to past issues and the lessons we have absorbed from process incidents over the years.
While more established or less sensitive molecules might allow for pooling batches or more relaxed release testing, palbociclib demands single-lot identification and release. Cross-contamination prevention and rigorous stability testing evolved directly from the business-critical requirement to support clinical and commercial programs simultaneously. A failed batch, once, meant delaying not just one customer’s order but potentially a whole clinical study. These pressures shaped our continuous improvement system and caused us to double down on end-to-end process monitoring.
Process risk often grows at scale. During early production, we encountered phosphorylation byproducts resistant to standard silica purification. The solution required reengineering the synthesis to cut out conditions that favored byproduct formation, incorporating in-line water detection, and revamping solvent purification. Only ongoing attention to such process tweaks, rooted in factory-level observation, has enabled reliable kilogram-scale batches. A few years back, an unexpected spike in environmental humidity during a single shift resulted in an entire day’s output failing moisture specs. That incident led us to invest in new HVAC and tighter room pressurization, avoiding repeats and supporting more regular batch throughput.
Raw material sourcing involves more than price and lead time; vendor changes can affect impurity fingerprints, which must be controlled tightly. After a supplier delivered a slightly different particle-sized starting material on a consignment, we noticed a small increase in related substance levels in the finished product. Supplier change control — qualifying multiple lots, keeping trace samples, and ongoing communication with our partners — now sits at the heart of procurement strategy. Lessons learned through such events underscore why batch-specific records and full material genealogy allow us to react quickly to unforeseen hurdles.
Another lesson arose with cleaning validation. Despite validated procedures and scheduled line cleaning, we once noticed cross-residue from a previous campaign. This prompted us to invest in continuous monitoring devices for real-time residue testing. Every cleaning event now finishes with both analytical confirmation and operator sign-off. These investments stem from direct experience, as even minimal residues in equipment can affect yield, stability, or appearance of the next palbociclib lot.
Palbociclib’s global use has only increased expectations for documented consistency. Every regulatory filing, inspection report, and client audit shapes how we handle change. Small molecule oncology agents require more data: extractable and leachable studies, genotoxic impurity assessments, and routine review of ICH guidelines. Every year brings revised criteria for solvents, particulates, and heavy metals, which can lead to changes in source materials or process steps. Our entire team, from synthesis to packaging, stays current with emerging standards, and we embed regular training cycles into operations.
Handling both process variation and regulatory feedback calls for open communication throughout the company. Operators report process drifts, analysts log every atypical chromatogram, and feedback loops tie back through the technical and QA teams. Our experience with regulatory warning letters years ago pushed us to develop more robust root cause analysis and corrective action planning. These were not optional upgrades, but critical measures learned the hard way, protecting both patient safety and business continuity.
Customer expectations have evolved alongside the science. More teams ask for detailed stability studies, expanded impurity datasets, and faster batch release times. The trend toward more personalized and targeted medicines, including next-generation kinase inhibitors, has only amplified these demands. In response, our manufacturing has become more data-driven and adaptive, integrating predictive analytics and early-warning systems for out-of-trend results.
Looking ahead, the growing pipeline of similar molecules will likely increase demand for robust manufacturing protocols, tighter contamination controls, and real-time process analytics. Our history with palbociclib monohydrochloride has laid the groundwork: every new molecule entering the suite benefits from lessons learned, process documentation, and investments in both technology and workforce expertise. Clients working on future therapies already expect detailed, individualized reports, and our ability to meet or exceed those expectations comes from solving for palbociclib’s unique challenges over the years — not from a playbook, but from direct experience on the floor.
From our view as manufacturer, palbociclib monohydrochloride is more than a chemical unit operation or line item. The discipline it demands — from raw material sourcing to process optimization, packaging, storage, and shipment — reflects a web of hands-on experience and growing regulatory standards. We’ve learned, sometimes painfully, just how deeply every small change ripples through the process, ultimately shaping the therapy one patient in a cancer center may receive. It’s this understanding, rooted in years of plant-floor work and daily problem-solving, that supports both our production and our clients’ changing needs.