West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

p-Terphenyl (purified by sublimation)

    • Product Name p-Terphenyl (purified by sublimation)
    • Alias TER145
    • Einecs 202-127-9
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    474297

    Chemical Name p-Terphenyl
    Synonyms para-Terphenyl
    Cas Number 92-94-4
    Molecular Formula C18H14
    Molecular Weight 230.31
    Appearance White crystalline solid
    Melting Point 212-214°C
    Boiling Point 375°C
    Purity purified by sublimation
    Solubility Insoluble in water, soluble in organic solvents
    Density 1.23 g/cm³
    Smiles c1ccc(cc1)-c2ccc(cc2)-c3ccccc3
    Refractive Index n20/D 1.669
    Storage Conditions Store at room temperature, away from light

    As an accredited p-Terphenyl (purified by sublimation) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Sigma-Aldrich p-Terphenyl, purified by sublimation, packaged in a 25g amber glass bottle with tamper-evident cap and safety labeling.
    Shipping p-Terphenyl (purified by sublimation) is shipped in tightly sealed, chemically resistant containers to prevent contamination and moisture exposure. The packaging complies with regulatory standards for safe handling of chemicals. It is labeled with hazard information and shipped via ground or air transport, according to international and local chemical shipping regulations.
    Storage p-Terphenyl (purified by sublimation) should be stored in a tightly sealed container, protected from light and moisture, in a cool, dry, and well-ventilated area. Keep away from sources of ignition, heat, and incompatible substances. Ensure storage conditions comply with chemical safety regulations, as supplied by Sigma-Aldrich, Merck, or TCI Chemical Grade standards. Always wear suitable protective equipment when handling.
    Free Quote

    Competitive p-Terphenyl (purified by sublimation) prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    p-Terphenyl (Purified by Sublimation): True Manufacturer’s Perspective

    Our Approach to p-Terphenyl Production

    After decades dedicated to aromatic hydrocarbons, producing p-Terphenyl gives me both pride and a steady lesson in patience. p-Terphenyl, known by its CAS number 92-94-4, appears as off-white, crystalline flakes with a characteristic mild aromatic scent. Our team follows strict in-house protocols to refine p-Terphenyl by sublimation, a process that separates impurities without involvement of solvents or filtering agents that risk introducing trace contaminants.

    Sublimation leaves us with material of high purity, usually 99% and above, but the number only tells part of the story. In our experience, the true value comes out when customers run it through their own sensitive applications: scintillation, specialty dyes, optoelectronic materials, or as a heat transfer agent. Every application puts its own demands on the product, and impurities—even at fractions of a percent—change physical behavior and downstream reliability.

    What Model Purified by Sublimation Means in Real Terms

    We don’t just label our p-Terphenyl as “sublimed” for marketing. In practice, this means handling repeated small-batch treatments under high vacuum, gradually collecting the purest parts while discarding tails and foreshots—the process is physically demanding, time-consuming, and leaves hands with a unique, pungent odor each shift. We do this to ensure every shipment comes out with a consistent melting point, clear of the brown or yellow discoloration that shows up in less carefully managed thermal treatments.

    Our material maintains a melting point near 212°C and stays colorless under the right handling. Issues like trace yellowing signal incomplete purification. Material from other sources—especially those only treated with solvents—often doesn’t dissolve as cleanly in tetrahydrofuran or aromatic solvents and can deposit stubborn residues. Downstream, this affects crystal growth for organic electronics or homogeneity in mixture for scintillator plates.

    From Chemicals to Real-World Function: Meeting Exacting Standards

    We’ve supplied p-Terphenyl for everything from organic light-emitting diodes (OLED) R&D to nuclear detector calibration. Every field reports its own pain points. For radiation detection, the difference between crystallinity grades is often visible by eye: a poorly-purified sample develops haze and non-uniform surfaces under UV exposure. In pure organic electronics, minimal iron and copper content matters since even parts-per-million can act as traps for charge carriers. Over the years, it’s become clear that application success rests heavily on the amount of care that goes into the original material processing and storage.

    Specification Details Brought to Practice

    Our main production lot falls consistently within these ranges:

    We pack under inert nitrogen to reduce oxidative discoloration, and employ glass or fluoropolymer-lined containers for shipments above 500g to prevent leaching and static charge buildup. Experience taught us that reusing generic liners imparts unwanted organics—leaving a faint petroleum note that signals product alteration at a chemical level.

    Distinction from Other Supplier Grades and Processing Methods

    Competitors often introduce p-Terphenyl purified only by recrystallization from solvents, a process that works for bulk pigment but leaves traces of mother liquor and contaminant aromatic fractions. Our sublimation batches undergo additional QA, including UV-vis spectroscopy to catch broad tailing or minute color shifts, and ICP-MS scans for sodium, iron, copper, and silicon that can sneak in from glassware or packaging.

    Some distributors tout “ultra-pure” or “electronic grade” thermally treated products. I’ve seen side-by-side comparisons where their material under a microscope reveals clustering and brighter spots—clear signals of incomplete separation. We test random storage samples three and six months after manufacture, watching for signs of color drift, clumping, or phase changes.

    The reason for stubbornly sticking with sublimation, despite the industry push for faster, larger-mass solvent extraction, is reliability in critical use. Solvent treatments fail to remove high-boiling residues or contaminants that are invisible until a device fails QA or a batch turns yellow weeks after shipping. Our technical team deals with customer feedback directly, so these details return to our labs, and we close the loop by methodically adjusting rebake times or modifying chamber cleaning cycles.

    Applications Benefiting Most From True High-Purity p-Terphenyl

    Customers approach us with unique requests: one group requires high-purity p-Terphenyl for single-crystal growth in organic semiconductors, another for use as a wavelength shifter in liquid scintillator detectors, and others as a key starting point for designer dyes. Few realize every adjustment in our process affects how their end products behave.

    In liquid scintillator manufacture, p-Terphenyl overlays the primary emission spectrum. Any colored contaminants or residues shift the baseline response of detectors, sometimes by ten percent or more. This can ruin sensitive nuclear readings. Ultra-trace metals, even those in the sub-ppm range, can poison catalysts during derivative syntheses. Our tightly controlled sublimation steps exist to ensure anyone formulating a secondary dye like POPOP or embedding it into a plastic matrix starts with reliable, interference-free material.

    In display technologies, trace impurities reduce carrier mobility and stability, directly causing premature dropout in OLED performance. Here, purity is more than a figure on a certificate—it comes down to how well the product we ship continues to perform after weeks, months, or even a year in storage under real-world handling, not just right after packing in our facility.

    Supporting Scientific Transparency & Traceability

    From the outset, our philosophy runs deeper than hitting a specification. Our lab logs detail each batch, with full traceability back to raw benzene sourcing, storage humidity, and even the cleaning solvents last used in our apparatus. Real-life chemical manufacturing—especially for specialty organics like p-Terphenyl—requires tightened practices, not only to reach high purity but to maintain it through packaging, storage, and transport.

    For those who’ve never run a bad synthesis due to an unseen contaminant, the value of rigorous traceability may sound excessive. For teams running multistep syntheses or calibrating high-sensitivity detectors, discovering the source of a trace impurity means the difference between a month’s lost work and a reliable result.

    We maintain archival samples of each production lot, available for re-analysis. Our QA lab tracks batch deviations in melting point, appearance, and chromatographic purity, cataloguing even minor trends to improve future syntheses. This log-based approach enables us to address customer queries accurately, building trust over one-off transactions.

    Challenges Unique to Manufacturer-Scale Production

    Scaling purification without sacrificing quality never follows a simple roadmap. The temptation to speed up or enlarge batch size consistently brings its own pitfalls: incomplete condensation, altered crystal morphology, or slow creep of batch-to-batch variance. Lessons come from failed attempts—glossy, plate-like surface crystals that cool too quickly shatter upon shipping, while overextended baking dulls the signature needle structure customers rely on for downstream use.

    Many problems only surface weeks after shipping: subtle color changes in the customer’s hands, unusual dissolution rates, or hints of haze after sample drying. These field reports take priority in production adjustments. We thoroughly test for reactive residues, monitor packaging oxygen ingress, and adjust storage durations based on actual shipment times, not just what works inside our own warehouse.

    A policy we maintain: any claim of out-of-specification material triggers a full re-examination, not just a paperwork review. We have brought product back from customers for reanalysis, and those reports check against retained reference material on shelf. We accept that, as a manufacturer, accountability lasts as long as our name is associated with that shipment.

    What Makes Our Sublimed p-Terphenyl Different?

    Beyond purity claims, the aspects that differentiate our product come out in routine, real-world chemical use. Chemists regularly call us out for the specific way our crystals dissolve—clear, no lingering film—and how little residue they leave under analytical detection. Batch reproducibility allows researchers to conduct multi-year studies without fearing unexplained drift in results.

    Those dealing with fine or specialty chemicals know that buying from traders often introduces variability batch-to-batch, with minor but persistent differences in shell, taste, or after-odor. We rely on in-house personnel to handle not just manufacturing but all end processing and QA. This gives us complete domain over every decision in the chain, from kettle temperature readings to how we purge equipment in between runs.

    We defer to customer batch feedback, actively encouraging return of unused material if any problem appears, since real feedback from field applications keeps the process evolving. Unlike brokers or downstream resellers, our accountability extends to every cut, every kilo shipped, whether destined for an academic project or critical diagnostic device.

    Continuous Improvement & Listening to End-User Experience

    The best improvements come from those using our material daily. Demands have changed: more customers run their own bench analytics, chasing ever-lower impurity thresholds for sensitive work. A decade ago, most buyers trusted certificates and only checked if visible color or melting point deviated. Now, liquid chromatography/mass spectrometry, UV-Vis scanning, and even isotope analysis have become accessible to individual labs.

    We regularly solicit and receive customer process feedback, using reported issues as “invisible specifications” to tune purification and packing. One example: a research group reported minor surface oxidation during summer shipments, prompting us to upgrade outer packaging to multi-layer foil pouches and overhaul our warehouse climate standards. On another front, batch complaints about slow filtration in an OLED manufacturing line led us to adjust crystal growth conditions, optimizing for both dissolution rate and physical integrity.

    We understand the frustration when a run fails due to minor shifts in raw material. Rather than simply defend our specs, we view each customer’s process as a live test bed, learning from every complaint to preempt future issues. Tight feedback loops with R&D and end-users generate improvements far more efficiently than awaiting repeat production failures.

    Environmental and Safety Considerations in Bulk Production

    From a chemical manufacturer’s viewpoint, environmental and safety concerns shape daily decisions around p-Terphenyl production. The aromatic hydrocarbon class tends to volatilize or linger in waste streams without careful handling. Reactivity risks and worker exposure demand strict safety protocols. Staff are trained not only on regulatory compliance but also through hands-on experience, handling high-temperature apparatuses and active vacuum lines.

    Production yields inevitable side fractions contaminated with heavy hydrocarbons or oxidized fragments, which our facility routes into closed-loop waste recovery, incineration, or authorized hazardous material channels. These steps cost time and raise overhead, but avoid downstream liability and ensure shipping safety. Any shortcut here shows up as customer complaints or regulatory scrutiny further down the line.

    Process controls, including air quality monitoring, leak detection, and redundancy in critical cooling and vacuum systems, come out of lessons learned—not just checklists. Overlooking these steps leads to hygiene issues, inconsistent product, or risk to worker health. All staff receive regular updates on process hazards so procedural discipline endures beyond initial training.

    Conclusion: Real-World Reliability Over Spec Sheet Perfection

    Clients who use our sublimed p-Terphenyl appreciate the difference in day-to-day handling, traceability, and responsiveness that comes from genuine manufacturing control. Those with experience in specialty organics can spot differences in product that seem minor on a spec sheet but turn into major issues in field use.

    Our goal centers on reliability. Every step in the process, from raw material to final shipment, reflects lessons learned and feedback from users who expose the product to real-world chemical stresses. The result: a product defined less by certificate data and more by the confidence and repeatability it brings to those who trust their projects to our expertise.