West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Nonafluorovaleric Acid (ca. 0.5mol/L in Water) [Ion-Pair Reagent for LC-MS]

    • Product Name Nonafluorovaleric Acid (ca. 0.5mol/L in Water) [Ion-Pair Reagent for LC-MS]
    • Alias NFVA
    • Einecs 206-206-3
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    483392

    Product Name Nonafluorovaleric Acid (ca. 0.5mol/L in Water)
    Chemical Formula C5HF9O2
    Concentration 0.5 mol/L
    Solvent Water
    Molecular Weight 264.05 g/mol
    Cas Number 2706-90-3
    Appearance Colorless to slightly yellow solution
    Purity Typically >98%
    Application Ion-Pair Reagent for LC-MS
    Boiling Point 181 °C (neat compound)
    Storage Temperature 2-8 °C
    Density 1.619 g/mL (neat compound)
    Pka 0.02 (approximate, neat compound)

    As an accredited Nonafluorovaleric Acid (ca. 0.5mol/L in Water) [Ion-Pair Reagent for LC-MS] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Nonafluorovaleric Acid (0.5 mol/L in Water) is supplied in a 100 mL amber glass bottle with tamper-evident cap.
    Shipping Nonafluorovaleric Acid (ca. 0.5 mol/L in Water) is shipped in tightly sealed, chemical-resistant containers to ensure stability and safety. It is classified as a laboratory-grade reagent (Ion-Pair Reagent for LC-MS) and may be regulated as hazardous; shipping typically occurs via specialized chemical courier under temperature-controlled conditions, with all required safety documentation included.
    Storage Nonafluorovaleric Acid (ca. 0.5 mol/L in Water) should be stored in a cool, dry, well-ventilated area, away from heat and incompatible substances such as strong bases. Keep the container tightly closed and protected from light. Store at recommended temperatures as provided by the supplier, typically between 2–8°C (refrigerated). Use chemical-resistant containers and appropriate secondary containment to prevent leaks or spills.
    Free Quote

    Competitive Nonafluorovaleric Acid (ca. 0.5mol/L in Water) [Ion-Pair Reagent for LC-MS] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Nonafluorovaleric Acid (ca. 0.5mol/L in Water) – Ion-Pair Reagent for LC-MS

    Experience-Driven Insights on a Key LC-MS Reagent

    A lot goes into manufacturing ion-pair reagents that meet the precise needs of modern laboratories. Nonafluorovaleric acid, in a well-controlled aqueous solution around 0.5 mol/L, stands out for its consistent performance and compatibility with liquid chromatography-mass spectrometry (LC-MS) systems. Decades of synthesis, purification, and feedback from analytic chemists guide our approach to this reagent, shaping careful choices in raw materials, equipment, and process controls.

    Why Choose Nonafluorovaleric Acid for Ion Pairing?

    The reputation of nonafluorovaleric acid as an ion-pairing agent springs from its unique chemical structure. The nine fluorine atoms on its backbone deliver strong electronegativity, impacting retention times and selectivity during chromatography runs. Its volatility and purity profile lower the risk of contaminating mass spectrometers—a real concern during long-term operation. Over time, we have seen customers gravitate towards this acid when requiring economical, reproducible results for analytes with challenging separation profiles. When we first introduced aqueous solutions near 0.5 mol/L concentration, positive feedback came swiftly from those seeking lower viscosity for high-throughput analyses.

    Focus on Purity and Consistency

    Manufacturing nonafluorovaleric acid typically starts with monitoring incoming fluoroalkyl building blocks, then moving through a carefully staged synthesis. Each batch faces strict chromatography and NMR analysis before blending. Since mass spectrometrists notice the smallest impurity spikes, we've invested in fractional distillation and resin purification to hold the background signal below method-specific detection limits. The ready-to-use aqueous solution reduces risk of user contamination when compared with powdered or concentrated forms that must be diluted in the lab—an especially important point when trace-level quantification matters and solvent-grade water can become a limiting variable.

    Reliability Over Hype

    Early on, we dealt with skepticism from chromatographers who questioned whether highly fluorinated acids belonged in their method. Several years of real-world use and method development put concerns to rest. From our experience, this compound resists degradation even through repeated freeze/thaw cycles and weeks of storage at ambient temperatures. No manufacturer’s process is immune to drift, but feedback on our batches never flagged a loss in performance when used as directed.

    Performance in Diverse Applications

    Ion-pairing with nonafluorovaleric acid can fix common issues in separating weak acids, bases, and biologically relevant analytes. Many peptide and nucleotide analyses show sharper peak shapes and less tailing—the direct result of charge balancing and controlled hydrophobic interactions in the mobile phase. In-house, we ran repeated tests on drugs, environmental residues, and synthetic intermediates, comparing peak area ratios and signal/noise against less substituted analogs. The unique hydrophobic chain length of nonafluorovaleric acid, paired with the non-nucleophilic character from fluorine substituents, leads to reliable retention without generating mass spec background. Our partners in pharmaceutical QC and academic research confirm these benefits during cross-lab method harmonization studies.

    What Sets This Solution Apart?

    Most commercial ion-pair reagents come in concentrate or salt forms, requiring end-users to weigh, dissolve, filter, and store solutions under controlled conditions. We’ve streamlined that step by offering a pre-portioned, approximately 0.5 mol/L solution. This eliminates in-lab weighing errors, saves time, and limits the possibility of cross-contamination. Years of supporting labs led us to standardize water grades and container materials for acid stability, so storage and shipping don’t introduce new error sources. The disposable bottle approach has cut down on decompositions that used to take chemists by surprise during inactivity, simplifying inventory management for high-throughput screening labs.

    Comparison to Other Ion-Pair Reagents

    We’ve supplied both perfluorinated and hydrocarbon-based ion-pair agents over the years. With trifluoroacetic acid or heptafluorobutyric acid, users often report higher volatility and potential for method interference through adduct formation in MS ion sources. The longer chain in nonafluorovaleric acid gives a more stable mobile phase composition at common flow rates, which in turn leads to less drift between instrument runs. Compared with traditional nonafluorinated counterions, the perfluorinated backbone of this acid is less reactive, generating minimal side reactions and virtually no polymeric byproducts. When labs run high-sensitivity work, small inconsistencies often add up—to tackle this, we apply the same batch-release protocols to every lot, logging all retention time and matrix-effect data for customers who need independent verification.

    Practical Notes from the Manufacturing Floor

    Our operators measure each raw material and finished acid on fault-checked scales. Automated pumps and checkweighers track every step, from acidification to dilution, to guarantee accurate molarity. In the early days, we mixed by hand in glassware, but demand—especially from contract research organizations—drove upgrades to closed, nitrogen-flushed systems that lock out moisture, dust, and background acids. We frequently compare customer returns to internal records, looking for drift in coloration, pH, or byproduct buildup. Rarely do we find anything out of specification, yet these audits help us improve quality controls and set ever-tighter release criteria.

    End-User Perspectives: Why This Matters

    Chemists and analysts rarely have time to troubleshoot solvent prep or figure out why retention times wander. We spent years gathering user feedback, conducting on-site visits, and monitoring complaints: time and again, the ability to open a bottle of nonafluorovaleric acid solution, pour into a solvent reservoir, and see performance mirror published methods made a significant impact on workflow efficiency. Our large-batch approach means each shipment reflects only minor variation from the last, giving instrument calibration teams confidence in their baselines over time.

    Method Validation: What Our Customers See

    We supply this product to pharmaceutical, food, and environmental labs who run regulatory methods on LC-MS systems. Their external audits often require traceability of each reagent batch, so we track every acid lot from raw material intake through mixing and bottling. We often hear back that retention times, calibration curves, and signal strength match peer-reviewed literature, giving analysts fewer variables to explain if unexpected results occur. The combination of high boiling point and strong acid properties lets this perfluorinated acid serve in both routine and challenging separations, reducing run-to-run carryover compared to shorter-chain analogs.

    Environmental and Operational Safety

    Handling strong acids with multiple fluorine atoms presents unique challenges in waste treatment and vapor control. Over the years, we’ve moved away from vented shipping and open-drum decanting to single-use, sealed bottles. These upgrades cut exposure risks for end users, since even small vapor losses from poorly sealed storage can trigger headaches or air sensor alarms. In our plant, all rooms handling this solution include negative pressure hoods and real-time fluorinated compound detectors. We mandate acid-resistant gloves and splash shields for everyone handling bulk material, but we also select safe, manageable volumes for each packaged unit, minimizing spill potential once containers reach customer labs.

    Waste Management and Disposal

    Many labs struggle to find solutions for the disposal of perfluorinated acids, some of which can persist in wastewater or soil. We encourage customers to collect used and surplus solutions separately from other waste streams. For high-usage clients, we can recommend certified hazardous waste handlers familiar with fluorinated organic acids. Over many years, we have developed take-back programs for unused material, supporting customers who need to comply with local restrictions on volatile organic compound emissions and persistent chemical disposal. We hope further process research will soon offer cleaner ways to break down perfluorinated chains, enabling safer downstream environmental outcomes.

    Research and Development Reflections

    Whenever new LC-MS technologies emerge, our R&D team puts nonafluorovaleric acid through fresh trials. We survey new detector technologies, source designs, and flow configurations to see how mobile phase composition and pH stability affect quantitation. Our own analytics show how this acid maintains peak performance even at very low detection limits, right down to sub-ppb levels for some pharmaceutical analytes. Batch-to-batch stability keeps internal standards reliable, so method validation runs achieve targeted RSD values for long and complex sample lists.

    Scalability and Batch Supply

    Industrial-scale production has taught us to pay attention not only to chemistry, but also to how small process tweaks ripple through a supply chain. We learned early to qualify every supplier, validate each cleaning cycle, and lock down delivery windows. Many of our long-term customers asked for multi-liter shipments with zero drift in acid strength, and we've responded by tracking all acid deliveries with certified reference checks. Today, most production lots support both high-volume users and boutique labs, shipped in containers from a few milliliters up to bulk canisters for central solvent prep systems.

    Solvent Compatibility and Storage

    This product is designed for long-term stability in sealed containers. From years of tests in both glass and specialty fluoropolymer bottles, we found nothing matches the acid-resistance and leach-proof characteristics of pure FEP and PTFE. Customers who transferred solutions to lower-grade plastics sometimes reported minor composition changes after extended storage; we always recommend leaving the acid in its original packaging until immediately before use. Refrigerators and solvent storage lockers both work for months at a time, so labs with fluctuating inventory demands can restock without worrying over shelf life. We publish in-house shelf life data drawn from accelerated aging tests, using refrigerated and room temperature storage to mirror actual lab practices.

    Feedback from Routine and Advanced Users

    The needs of research and quality labs share one constant: minimizing downtime. Routine diagnostic chemists often want stability in their methods, so mobile phase composition changes don’t chew up hours of re-calibration. They often mention that this pre-mixed solvent removes guesswork, especially when moving between separate instrument platforms. University researchers, exploring novel compounds or metabolomics, look for suppression and enhancement effects across LC-MS ionization regimes; their feedback on matrix effects and detection thresholds prompted us to refine our purification steps. From both groups, requests for documentation, SDSs, and clear handling notes always receive quick responses, since our technical development teams keep a direct line of communication open with our user base.

    Anticipating Trends in LC-MS

    As sample complexity and throughput increase in both regulatory and academic labs, the demand for low-impurity, MS-compatible ion-pair reagents has soared. Over the last decade, high-resolution instruments have made background suppression and contaminant tracking more critical. By keeping a tight rein on fluorinated byproducts and offering ready-to-use solutions, we’ve made it easier for teams to adapt new methods rapidly. We constantly monitor publications, conference presentations, and application notes to ensure process tweaks reflect latest user challenges—from bioanalytical serum assays to forensic trace drug screens.

    Supporting Method Transfer and Global Consistency

    Regulators increasingly demand that analytical methods transfer easily between labs, companies, and countries. Method harmonization can fall apart if small inconsistencies creep in through reagent preparation. Chemists often tell us that using a single, manufacturer-prepared batch smooths out the bumps in method transfer, drastically reducing troubleshooting times and unwelcome surprises from matrix effects. Multinational pharmaceutical customers lean heavily on our cumulative batch records—which log everything from raw material analytics to final solution pH—to support regulatory filings and inter-lab validations.

    Our Commitment to Chemical Sustainability

    Fluorinated organic acids have come under increased scrutiny for persistence in the environment and potential health effects. We track global regulatory trends and invest in process upgrades to cut emissions, reduce waste, and increase accountability from synthesis through final shipment. Our plants focus on solvent recycling, closed waste streams, and next-generation equipment that collects any vapor loss before it leaves containment rooms. We also work with environmental researchers to test breakdown methods for perfluorinated molecules, hoping to make safer alternatives available where possible.

    Looking Forward: Product Evolution

    The growth in LC-MS usage has brought increasing pressure for cleaner, safer, and more user-friendly reagents. Our team constantly refines purification, filling, and packaging systems to keep pace with these expectations. We keep open channels for customer feedback, from usability in the field to regulatory reporting needs. As global standards tighten, we remain committed to both supporting top-tier science and building production with an eye on future environmental and human safety limits—without sacrificing analytical reliability.

    Summary of Experience-Based Benefits

    Producing nonafluorovaleric acid solutions for LC-MS use brings together decades of practical know-how, chemical expertise, and customer support. Every step in our process reflects lessons from thousands of chromatographers, instrument vendors, and QA teams. Our solvent is chosen not just for what it is, but for what it avoids—bottle-to-bottle variability, background noise, and preventable user mistakes. For labs under regulatory scrutiny, our batch traceability and established supply chain ensure compliance without workflow headaches. For discovery chemists, the low impurity profile sustains both reproducibility and freedom to explore new methods, sample types, and detection technologies. Every year, as technology evolves, we adjust to match it—without losing sight of the lab realities and safety responsibilities that matter most to our customers.