West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

n-Octane [for HPLC Solvent]

    • Product Name n-Octane [for HPLC Solvent]
    • Alias Octane
    • Einecs 205-563-8
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    164170

    Product Name n-Octane [for HPLC Solvent]
    Chemical Formula C8H18
    Molecular Weight 114.23 g/mol
    Cas Number 111-65-9
    Purity ≥99.0%
    Appearance Colorless liquid
    Boiling Point 125-127°C
    Melting Point -56.8°C
    Density 0.703 g/mL at 25°C
    Refractive Index n20/D 1.397
    Flash Point 13°C (closed cup)
    Water Solubility Insoluble
    Vapor Pressure 14.0 mmHg at 25°C
    Storage Temperature Room temperature
    Un Number 1262

    As an accredited n-Octane [for HPLC Solvent] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing n-Octane [for HPLC Solvent] is supplied in an amber glass bottle, 1 liter, with a tamper-evident cap and chemical-resistant labeling.
    Shipping n-Octane [for HPLC Solvent] is shipped in sealed, chemical-resistant containers, clearly labeled for laboratory use. Transport complies with DG (Dangerous Goods) regulations, ensuring proper handling, safety documentation (SDS), and temperature controls. Packaging from Sigma Aldrich, Merck, or TCI ensures product integrity and safe delivery to laboratories worldwide.
    Storage n-Octane [for HPLC Solvent] should be stored in a tightly closed container, in a cool, dry, and well-ventilated area, away from direct sunlight and sources of ignition. Keep away from incompatible materials like oxidizing agents. Store at room temperature and ensure proper labeling. Follow local regulations for flammable liquid storage, and use appropriate containment to prevent leaks or spills.
    Free Quote

    Competitive n-Octane [for HPLC Solvent] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    n-Octane for HPLC Solvent: A Manufacturer’s Perspective

    Our Experience Making n-Octane for Specialized Analytical Work

    Over decades in chemical manufacturing, I’ve learned that not all solvents handle the challenges posed by advanced laboratory techniques. n-Octane tuned for HPLC (High Performance Liquid Chromatography) brings together technical accuracy and production know-how. This isn’t a matter of batch blending or routine distillation; creating n-Octane that supports tough detection limits and avoids contamination means taking responsibility for every step, from feedstock sourcing to final fill.

    Analytical consistency starts long before the solvent reaches a chromatography lab. As manufacturers, we go straight to petrochemical origins and oversee every phase of refinement. We select premium-grade feed for distillation, and every intermediate undergoes extra purification cycles. We run the n-Octane through fractional distillation towers, stripping off light and heavy fractions until the target boiling range sits precisely in spec. Routine solvent-grade octane won’t match this level; even subtle impurities, like minor branched hydrocarbons, phosphates or traces of sulfur, can skew data or leave behind residue on columns and detectors.

    Model, Purity and Specifications

    Our n-Octane for HPLC solvent applications comes under the OCA980 model code at our site. Typical purity sits above 99.9% by gas chromatography, but purity alone won’t deliver reproducible separation or a blank baseline. We keep a close eye on UV absorbance at multiple wavelengths (often 210 nm and 254 nm) because organic fines—sometimes undetectable by routine analyses—lead to baseline drift or false peaks below one part per million. Trace water content measured by Karl Fischer titration always falls below 0.005%. Metals are checked by ICP-OES to the ppb range. This level of scrutiny comes from lessons learned the hard way—corroded injector valves and ghost peaks show up whenever even a single production variable drifts out of line.

    Physical specs that matter for routine and gradient elution in HPLC are always part of our QC charts: boiling point (typically 125.7°C), density at 20°C (about 0.703 g/mL), refractive index, and evaporation residue. We also screen for halide ions and keep chloride well under a milligram per liter. Many solvent grades offered elsewhere skip some of these steps. For us, this attention to detail didn’t arrive by accident; every failed batch over the years taught us that skipping small controls creates bigger problems later—blocked columns, ghost peaks, memory effects, wasted samples.

    Why n-Octane Remains a Critical Solvent for HPLC

    Manufacturers with a background in chromatography research know n-Octane isn’t just a hydrophobic solvent—it shapes selectivity in many normal and reversed-phase HPLC methods. Its defined nonpolarity, coupled with low UV cut-off (around 210 nm), keeps the background clean and avoids interfering with analyte signals. Some users try heptane or hexane alternatives, and there’s value in each, but n-Octane offers a balance between volatility and solvation that heptane can’t reach and hexane can’t hold for longer retention times. Lower volatility compared to hexane reduces losses during mobile phase prep and keeps changes in mobile phase composition low during long analytical runs.

    A common challenge among chromatography labs is dealing with contaminants at the point of use. Many technicians work with octane grades not made for HPLC, sold in drums or even contaminated by plasticizers from packaging. Manufacturing HPLC-grade n-Octane means controlling every transfer, container lining and fill, right down to the final purge with high-purity nitrogen. Recycled or repackaged octane enters the supply chain, especially when there are price pressures. I’ve seen customers come to us after trying these shortcuts: months spent troubleshooting erratic signals, only to trace it back to a trace impurity or batch cross-contamination. These are solvable at the manufacturing step, not in the lab.

    Batch Consistency and Its Real-Life Impact

    We run HPLC validations with our own solvent on reference-grade columns before each batch goes out. It’s one thing to meet a number on a spec sheet, but our work matters most during real sample runs: pharmaceutical actives, botanicals, food safety checks. I remember several years back, a major pharma client flagged spikes in the outflow of one of their test drugs. By tracing back through their mobile phase and reference standards, we identified halogen contamination in their supposedly “chromatographic” grade octane—irregular product from another supplier. Swapping in our n-Octane fixed their baseline noise within a day. Such events highlight that purity testing must track every possible contaminant and that batch-to-batch consistency can’t just mean “about” the same purity each time.

    Our on-site labs reserve each batch long after shipping. Stability checks over time at -20°C and room temp ensure the solvent doesn’t pick up moisture or degrade in storage. Container materials matter: we only use pre-cleaned amber glass with PTFE-lined caps for small-format packaging, and for bulk we offer stainless steel reusable drums, passivated and vacuum-purged after every fill and return. Each choice comes from field experience—flimsy plastic or unlined steel drums will leach microcontaminants, even if the solvent arrived clean. Many users overlook inert packaging at their own risk.

    Building Trust in Laboratory Analysis

    That trust starts by knowing what happens behind the scenes in chemical manufacturing. DIY or simply trading generic industrial n-Octane doesn’t give a user control over origin or composition. Labs aiming for reliable chromatographic data need the solvent to perform—not just appear clean, but actually stay artifact-free during high-sensitivity work. We’ve invested in cold-filtration systems, high-capacity distillation with multiple cut points, continuous nitrogen blanketing, cleanroom filling and nearly redundant batch records traced back to each raw material barge or truck.

    This level of scrutiny isn’t for show. Regulatory authorities, pharmaceutical customers, food analysis labs and environmental agencies all demand documentation. An accreditation body once showed up unannounced. Our historical records for n-Octane lots included raw material batch, column performance validation, GC verification logs, and even storage temperatures before shipping. Every number tied back to a real QC sample stored on site. Confidence in an analytical standard starts with traceable, audited production.

    We’ve worked side-by-side with lab teams, watching their gradient runs and troubleshooting drops in detector sensitivity. Time after time, the solution lay in the solvent. While upstream source and production checks require effort, they pay off through reliable analysis. Fewer instrument cleanings, less downtime, and tighter peaks mean more accurate results, fewer failed validations, and more published papers that stand up to scrutiny.

    Practical Differences From Other n-Octane Grades

    Not every n-Octane is alike. Industrial or reagent grades often skip purification or final filtration. As a producer, I’ve seen suppliers blend fraction cuts from different distillation streams, introducing trace solvents, lubricants or anti-static additives. This doesn’t matter if you’re washing a reactor, but these extras spell disaster for an analytical method. Some manufacturers run bottles through automated lines that handle acids, esters or glycols on the previous shift. We run dedicated filling lines, perform blank runs between solvents, and audit every line for cross-contaminants.

    Some of the sharpest differences show up in subtle ways: the clean baseline in a UV detector, the quick recovery of peaks after flushing, the ability to run long sample sets without losing sensitivity. Water and peroxide levels are often missed by batch spot checks; we measure every batch, with peroxide scavenging and extra drying built in. Even our bulk shipments keep the solvent under dry inert gas blankets. Many so-called “HPLC grade” products degrade rapidly after opening; as a result, labs sometimes blame the instrument when deterioration really started with the solvent.

    Usage Stories From the Field

    n-Octane shines in a wide range of methods, from pharmaceutical actives to environmental pollutants. It provides a middle ground for separation in normal-phase HPLC, and its consistent evaporation and low residue make it ideal as a sample prep diluent. We deliver to forensic labs testing trace explosives, university groups working on plant alkaloids, and contract laboratories where a single false positive would send results back for review.

    One university group contacted us after they struggled with drift in pesticide baselines; their method required UV detection down to 210 nm, and their in-house solvent stock, sourced from an industrial-grade drum, left background absorbance too high. After switching to our HPLC n-Octane, their background dropped by 50% and their detection limits improved. Another group running environmental testing on soils for PAHs found particulate residue in their pre-filtered solvent, which previously caused several columns to clog. With tighter control over our inline filtration, they stopped losing columns after a few dozen runs.

    Larger manufacturing groups depend on us for both supply chain reliability and solvent performance in process development. A major agchem producer struggles with lot-to-lot variability in other solvents. With n-Octane produced under fixed distillation, in small controlled batches, and with direct shipment scheduling, their analysis team cut internal investigation time by a third. It’s not just about each sample passing—solvents that perform consistently allow teams to push their methods harder, move to lower detection limits, and handle dirtier matrices without constant adjustment.

    Continuous Improvement and Industry Challenges

    Laboratory analysis has grown more complex. Detection levels continue to drop while method complexity goes up, putting extreme pressure on solvent purity. User demands and new cartridge/column tech mean what counted as “pure enough” last year might cause subtle interference in a new method today. Our QC lab keeps evolving; we pull and store retention samples, challenge older product lots under accelerated conditions, and partner with research groups to validate against new analytes and detector designs. Keeping ahead means never treating the process as finished.

    Supply disruptions and counterfeit solvents have become a growing problem—batches refilled into old drums, diluted with off-spec material, or misrepresented as HPLC grade. We see a strong need for users to demand more robust origin documentation—batch traceability, in-house certificate verification, and assurance on transportation and storage. End-to-end control only happens at the producer level. Resellers usually lack any direct view of production, batch handling or plant history.

    We work with transportation partners willing to collaborate on traceable shipping—sealed tankers, direct delivery, condition monitoring on bulk drums. To support customers, we started offering digital batch records accessible by QR code, giving instant access to certificate data, date of fill, storage interim, and the grade history of each drum, including any container refurbishments. These responses come directly out of field data requests—labs want to know what they’re using, and modern informatics makes this possible.

    Supporting the HPLC Community: Next-generation Solutions

    Growth in green chemistry and sustainability asks new questions of all producers. We’ve piloted the use of bio-based feedstocks for limited n-Octane runs and invested in closed-loop solvent recovery, recycling internal process waste for feed into the next distillation cycle. We track environmental impact and support user programs for return of empties and drum recycling. Customers in academic and regulatory spaces report positive feedback as they move toward zero-waste labs. Waste minimization, alongside solvent purity, defines the future of our sector. Knowledge learned making n-Octane translates directly to building cleaner, lower-impact chemical supply chains.

    Ultimately, making a dependable HPLC-grade n-Octane starts with a manufacturer’s accountability. We built every control, every test, and every improvement into our process because real users—people running real samples—depend on us. Our strict specs are not “corporate policy”; they’re the outcome of trial, error, and listening to labs across the world. No two producers work exactly the same way, but in analytical chemistry, results win. As the producer, we’re proud every time our n-Octane stands up to the strictest test in the toughest field lab, because we know every step that went into that bottle.