|
HS Code |
492106 |
| Product Name | N,N,N',N'-Tetramethylethylenediamine [for Electrophoresis] |
| Chemical Formula | C6H16N2 |
| Molecular Weight | 116.21 g/mol |
| Cas Number | 110-18-9 |
| Physical State | Liquid |
| Color | Colorless |
| Boiling Point | 121-122°C |
| Density | 0.775 g/mL at 25°C |
| Purity | ≥99.0% (GC) |
| Solubility | Miscible with water |
| Odor | Ammoniacal |
| Refractive Index | n20/D 1.398 |
| Storage Temperature | 2-8°C |
| Application | Used as a catalyst and for polyacrylamide gel electrophoresis |
| Synonyms | TEMED, TMEDA |
As an accredited N,N,N',N'-Tetramethylethylenediamine [for Electrophoresis] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The 100 mL Sigma-Aldrich N,N,N',N'-Tetramethylethylenediamine [for Electrophoresis] is packaged in a clear, sealed glass bottle with safety labeling. |
| Shipping | N,N,N',N'-Tetramethylethylenediamine [for Electrophoresis] is shipped in tightly sealed containers, protected from light and moisture. Classified as a flammable liquid, it is transported according to safety regulations, with proper labeling and documentation. Ensure upright storage and secondary containment during transit. Handle only by trained personnel using appropriate personal protective equipment (PPE). |
| Storage | N,N,N',N'-Tetramethylethylenediamine [for Electrophoresis] should be stored in a tightly sealed container in a cool, dry, well-ventilated area away from heat, moisture, and incompatible substances like acids and oxidizers. Protect from light and sources of ignition. Use only with adequate ventilation and follow all safety guidelines according to Sigma Aldrich, Merck, or TCI chemical grade specifications. |
Competitive N,N,N',N'-Tetramethylethylenediamine [for Electrophoresis] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Those who run a polyacrylamide gel to separate proteins know that every detail counts. We put two decades into producing N,N,N',N'-Tetramethylethylenediamine (TMEDA) at scale for laboratories demanding optimal consistency in their electrophoresis runs. Through constant investment in purification and batch processing controls, we have learned some lessons the hard way about why genuine manufacturing control matters. We control everything from raw material input through the distillation columns to the final packaging so users can focus on research, not troubleshooting strange band artifacts.
Making TMEDA for electrophoresis work calls for obsessive attention to water content, residual monomers, and minor amines. Most suppliers just stock industrial-grade TMEDA or private-label a basic lab reagent. We engineer a grade specifically for electrophoresis, with moisture content held typically below 0.03% and amine-related impurities kept at trace levels that don’t shift gel polymerization. Our staff run batches in stainless steel and glass-lined vessels with inert-gas blanketing to minimize oxygen and keep peroxides below detection. Each lot gets checked by gas chromatography for purity, followed by Karl Fischer titration for water and routine UV-spectroscopy scans to spot anything that could sabotage your experiment.
In production, a simple flaw in column hold-up, valve maintenance, or cleaning can spike the impurity profile. We adapted our lines years ago with high-temperature vacuum distillation, so leftover iron or copper catalysts from typical large-scale amination never have a chance to sneak into a sensitive lot. The polymerization step in your gel just will not tolerate iron at part-per-million levels. Pulling every technical knob we have ensures you’re not fighting wobbly bands because of a shortcut taken on an industrial line.
Many labs learn this only after seeing inconsistent gel runs with off-spec TMEDA. The generic types sold through distributors are pulled from streams originally aimed at textile finishing, resin modification, or water treatment. They pass basic amine-content checks but pay little attention to trace oxygenates, stabilizers, or chromophores that could float through in ppm or ppb amounts. After receiving frustrated calls and sample requests from both University and industrial customers, our technical team started batch-testing several commercial lots head-to-head. It is striking to see how a colorless liquid can contain hidden UV-absorbing impurities, causing streaking or faint artifacts in higher-sensitivity silver staining.
We tune our TMEDA output for labs requiring enzyme-level reproducibility, not just bulk reactivity. Our stricter endpoint criteria mean staff take extra time to exclude “tails” and “heads” at the fractional distillation cut, resulting in a higher cost per kilogram but eliminating the most troublesome minor byproducts. These byproducts—sometimes ignored by others—can show up as subtle baseline noise or inhibit free-radical polymerization. We saw one industrial customer lose an entire batch of protein separations because a refinery-sourced TMEDA carried over ethylamine and hydroperoxide residues. From our side, each batch gets certified by our on-site application team with a trial polymerization. If a gel fails to polymerize properly, that lot is flagged and doesn’t ship.
As the original manufacturer, we maintain control over our model specifications. For electrophoresis, that means a minimum purity specified as greater than 99.5% by GC, a water content tightly regulated below the established 0.03%, and UV absorbance below 0.05 at 260 nm, which our own R&D experience found most directly relates to interference with downstream protein detection. Each drum and bottle is nitrogen-flushed and sealed at the point of fill—our own packaging lines never use recycled containers to prevent trace contamination. Shelf-life assessments are done on real-time held batches, so expiry dates are given conservatively, rather than padded to meet paperwork requirements.
Time and again, too many market products are “rebottled” or diluted at third-party facilities. These steps introduce variables from dissolved gases, plasticizers leaching in, or minor air oxidation. By keeping the entire process within our plant and maintaining closed-system transfers, we give an extra margin of safety for users running critical analytical or preparative gels.
We have seen labs lose days of work and risk compromised reproducibility from little-known details about chemical handling. TMEDA is hygroscopic and picks up water from ambient air shockingly fast. Adding a few microliters of water per milliliter might not ruin a general amine reaction, but in acrylamide gel polymerization, it shifts catalyst ratios, throws off stacking, and can flatten band sharpness. That is why our packaging and shipment routine always include desiccant monitoring in each case. We test each outgoing lot for peroxide formation, since small air leaks or a reused septum can allow just enough oxygen to react with the amine and create a free-radical scavenger, stopping polymerization before it starts.
Practical laboratory feedback helped us tighten these practices. Feedback from protein biochemists and electrophoresis core facilities led to our current documentation standard, where every batch includes not only a certificate of analysis but a polymerization test sheet showing performance in a defined acrylamide system. Nobody should have to spend an afternoon reading forum posts or troubleshooting gel run failures because of bad TMEDA.
Production-grade TMEDA for generic uses often comes with variable impurity profiles and batch-to-batch variation. It is made to fuel epoxidations, resin curing, or textile process lines, not as a reagent for high-resolution protein gel work. The industry standard tolerates color, slight amine odor, and water up to 0.5%—this avoids costly drying steps and maximizes plant throughput. By contrast, our production imposes drying and inert transfer, chemical polishing, and a triple-filtration system specifically because these steps protect the subtle chemistry at play in electrophoresis.
Lots destined for gel work face much more scrutiny, down to the handling and storage environment. We maintain positive-pressure cleanrooms for final fill. Each product batch sits for a minimum of two days in a monitored holding tank under inert gas to confirm long-term stability before shipping. No batch certified for electrophoresis leaves our plant without a sign-off from our in-house analytical chemists, who track performance over time by holding "archive samples" from each lot.
Busy research labs want reagents to work the first time. Nobody on a grant deadline has the luxury of wasted gels. Random banding, faint background haze, or slow polymerization trace back to small mistakes in amine handling every time. Access to a direct-from-manufacturer grade, with all certifications and supporting test data, shrinks error rates and lifts reproducibility from run to run.
We try to manage risk for our users by offering technical support from the plant floor. Our chemists document every change in raw material, cleaning protocol, or packaging batch, so if a problem ever emerges in the field, samples can be traced to source in hours. Working directly with labs, we sometimes spot emerging issues—like the influence of aged TMEDA or the build-up of microcontaminants in suboptimally-stored containers—that feed back into our company’s R&D and process refinement.
On the cost side, prioritizing high-purity TMEDA looks expensive compared to bulk material. Yet, every failed run avoided, every clear and repeatable result, and every hour saved on troubleshooting adds up. Our customers tell us this margin for error is worth it over the year, even as grant budgets get tighter. The feedback loop between QC, application science, and final product sets us apart from repackagers and traders where the supply chain’s origin is murky.
The chemistry inside an electrophoresis gel run comes down not just to major components, but to what is absent. Oxidative impurities fuel free radicals at the wrong time. Water content swings polymerization speed. Trace metals and colored materials interfere with downstream protein detection. TMEDA for electrophoresis needs a level of care in finishing that comes from understanding what is at stake in a run—those faint bands separating isoforms or signaling a new protein target.
In-house studies using both silver stain and Coomassie protocols proved that small variations in TMEDA feed affect not just the clarity but also quantification by densitometry. Research projects on post-translational modification and antibody validation rely on consistency that low-grade amines cannot deliver. One publication out of our customer base identified a drop in assay sensitivity after inadvertently switching to off-brand TMEDA—a setback that cost several weeks for the lab involved.
Our willingness to work transparently with core facilities, sending out blind-coded TMEDA samples for independent side-by-side tests, drove us to continuously refine not just the chemical endpoint, but every human and mechanical process in our plant. Lab clients know exactly what is in—and what is not in—the bottle. By publishing typical impurity profiles (ethylenediamine, methylamine, iron, copper, and residual water), we let users correlate purity to performance.
As manufacturers, we often get urgent calls from scientists whose last batch of TMEDA failed them in the middle of a protein run. The root cause chart nearly always points back to material sourced through a non-manufacturing reseller, a shipment held for too long in humid conditions, or a bottle that arrived only loosely capped. We designed shift procedures across our fill lines specifically to avoid last-minute “hot swapping,” which tends to open the door for these issues.
Our advice to end users always flows from years fighting these same headaches in application trials. We recommend dispensing only under dry conditions, with tightly sealed bottles backfilled with dry inert gas. Never keep an open bottle on the bench more than the hour needed for setting up your gels. We keep a hotline open for technical support—with our staff ready to dive into specifics, not just forward a product data sheet.
Looking at operational data, we saw customers who managed material properly needed fewer reruns, saw less baseline drift on their stained gels, and experienced less batch-to-batch variability. These are measurable benefits. Every fraction of improvement translates to time gained, not just improved data.
Direct manufacturers differ from resellers in more than just price and paperwork. As producers, we see the full raw material stream. Our direct input contracts with primary chemical plants specify impurity ceilings from the outset. This gives us leverage to stop shipping if raw amine composition drifts. We make our own adjustments in real-time: tweaking pressure-height on the columns, re-drying after maintenance, and auditing every process step with staff who know what a failed gel run means for a user in a real lab.
During COVID supply chain turbulence, these connections allowed us to keep electrophoresis-grade TMEDA available, even as generic industry grades vanished from inventory. Our fully integrated production enables a continuous improvement loop: field issues feed analytical upgrades, and our in-house QC lab can push changes from method validation to full-scale production in a matter of days, not months. No distant procurement queue, no finger-pointing between vendor and packager—just accountable, traceable quality from start to finish.
Customers with compliance requirements in medical or regulated environments gain extra security knowing that our material origin and full chain of custody can be traced back to the individual operator, date, and process line. Routine audits by international certification bodies confirm that GMP and ISO routines are not just on paper. By contrast, third-party relabelers often provide only the most basic traceability, lacking the deeper connection to manufacturing know-how that prevents small problems from turning into batch ruins.
We believe that chemical manufacturing for life science needs to move past commodity thinking. As expectations for reproducibility climb and data standards tighten, consumables like TMEDA become even more critical. This is especially true for new protein detection techniques and multi-color fluorescent electrophoresis, where background artifacts or low-level impurities have an outsized impact.
Continuing investment in process automation, raw material planning, and honest feedback from real-world beta users shapes our approach. Rather than just match a published purity number, we work hand-in-hand with partnering labs to redefine what “electrophoresis-grade” should mean. The lessons we learn from each production cycle—and each troubleshooting session with an end-user—drive the cycle of innovation, helping us improve both chemical and operational transparency.
Making TMEDA by the book isn’t enough for critical lab work; the extra care in moisture control, impurity screening, and application testing comes from understanding the pain points scientists face. Every bit of knowledge picked up over years of production finds its way into a better product, with the user in mind from batch design to packaging and troubleshooting. Our approach goes beyond chemistry—it’s a partnership with researchers, built on traceability, transparency, and technical support that aims for more than compliance. Our TMEDA, designed for electrophoresis from the ground up, turns what might seem like a routine reagent into a foundation for reliable, reproducible results at the bench.