West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

N,N-Dimethylcyclohexylamine [for HPLC]

    • Product Name N,N-Dimethylcyclohexylamine [for HPLC]
    • Alias DMCHA
    • Einecs 206-046-9
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    558486

    Product Name N,N-Dimethylcyclohexylamine [for HPLC]
    Chemical Formula C8H17N
    Molecular Weight 127.23 g/mol
    Cas Number 92-50-2
    Purity For HPLC
    Appearance Colorless to pale yellow liquid
    Boiling Point 167-170 °C
    Density 0.84 g/mL at 25 °C
    Refractive Index n20/D 1.442
    Flash Point 49 °C
    Storage Conditions Store at room temperature, tightly closed
    Solubility Miscible with organic solvents

    As an accredited N,N-Dimethylcyclohexylamine [for HPLC] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing N,N-Dimethylcyclohexylamine for HPLC is supplied in a 100 mL amber glass bottle with a secure screw cap, labeled appropriately.
    Shipping N,N-Dimethylcyclohexylamine [for HPLC] (Sigma Aldrich/Merck/TCI Chemical Grade) ships in tightly sealed containers, protected from moisture and light. It is classified as a hazardous chemical and is shipped according to international regulations. Shipping includes protective packaging and documentation, with express delivery options to minimize transit time and ensure product integrity.
    Storage N,N-Dimethylcyclohexylamine [for HPLC] should be stored in a tightly sealed container, away from light, heat, and moisture. Keep it in a cool, well-ventilated, and dry area, preferably at 2-8°C (refrigerated). Ensure that it is segregated from incompatible substances, such as strong acids and oxidizers, and label the container clearly with appropriate hazard information.
    Free Quote

    Competitive N,N-Dimethylcyclohexylamine [for HPLC] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    N,N-Dimethylcyclohexylamine for HPLC

    Our View from the Production Floor

    Few things in chromatography frustrate a lab manager more than inconsistency in reagents. Having manufactured N,N-Dimethylcyclohexylamine for HPLC applications for years, our team has spent a lot of time and resources understanding what actually impacts performance at the bench. The best way to talk about this product is to tell the story of how our approach has changed over decades of production, and why the details matter well beyond ticking boxes on a spec sheet.

    The Heart of Reliable HPLC: Purity You Can Trust

    We focus on N,N-Dimethylcyclohexylamine, particularly formulated for high performance liquid chromatography work. HPLC labs depend on reliability—run-to-run differences in mobile phase additives don’t just waste time, they send researchers on wild goose chases for phantom contaminants. Our experience in this field has taught us that keeping water content extremely low, and maintaining a consistent amine-to-contaminant ratio, prevents baseline noise and detection errors in HPLC.

    Typical model: N,N-Dimethylcyclohexylamine (CAS: 98-94-2), produced and refined to meet trace impurity thresholds demanded in modern analytical environments. Experience tells us that pushing for “just good enough” purity does not cut it. It’s tempting to treat small variances—halogenated impurities, oxidized amines, metal traces—as non-issues, but these have derailed many a lengthy analysis. Our in-house gas and liquid phase purification steps specifically target these issues, going well beyond usual Commodity or Technical grade standards.

    Tracing Each Batch, Lab to Loading Dock

    To illustrate how serious we get about quality: every production batch undergoes a complete GC-MS and elemental analysis, not out of regulatory obligation, but because we’ve seen subtle differences cause failures on customer HPLC systems. Sometimes these shifts only become visible after a dozen runs. By preserving full traceability—batch records, analytical results, timestamps—any anomaly spotted in downstream workflows can be mapped back to our actual data, not third-party claims.

    Our purification process is tuned with live feedback from partner labs performing HPLC. If a batch exhibits slight drift in water or trace organics outside agreed-upon thresholds (often below 0.02%), it doesn’t ship. Managing these details requires collaboration beyond the plant floor. We routinely sit with customer analysts, reviewing their baseline data side by side with our own lab techs, tracing sources of ghost peaks, chloride noise, and retention variability. More than once, these sessions led us to refine reactor cleaning steps or overhaul entire lines to respond in real time to the needs of HPLC precision.

    Specifications Built through Actual Use

    The final specs on our N,N-Dimethylcyclohexylamine for HPLC have emerged from back-and-forth with chromatographers. Key numbers: assay typically exceeds 99.8% by GC-FID, residual water below 0.03% as determined by Karl Fischer titration, and total heavy metals held to below 0.5 ppm. These values did not come from guesswork or marketing—each is rooted in actual HPLC method requirements from food safety, pharmaceutical, and academic customers.

    Matching those figures, though, turns out to be only part of the story. The batch-to-batch consistency, verified by comprehensive documentation, has a bigger impact than chasing hypothetical upper purity limits. What matters to our partners is waking up Monday morning and knowing their elution profiles will match last week’s, no matter what. The only way to do that is internal discipline; we maintain the same reactor systems, solvents, and purification sequences rigorously to avoid introducing new variability.

    We’ve compared our HPLC-grade N,N-Dimethylcyclohexylamine head to head with other lab supply materials calling themselves "analytical" or "HPLC" grade. Wide swings in UV-absorbing impurities and color develop in these alternate products, especially after prolonged storage or exposure to air. We build our lots to outlast these conditions, using nitrogen blanketing and moisture scavenging during fill and packaging stages.

    Real Differences That Matter for HPLC

    There are dozens of amines marketed for HPLC. We have handled several of them: N,N-Dimethylaniline, N,N-Diethylethanolamine, and analogues. In hands-on use, these amines differ not only in physical properties and volatility, but in the way they interact with silica columns, mobile phase buffers, and detector optics.

    N,N-Dimethylcyclohexylamine’s cycloaliphatic structure means a higher boiling point and lower volatility. This gives it distinctive benefits during gradient elution and extended LC runs. During purification, the compound’s hydrolytic stability stands out: under repeated freeze-thaw cycles, no breakdown is detected by NMR, while open-chain analogues slowly oxidize or hydrolyze, generating noise in method blanks.

    Comparing dimethylcyclohexylamine to tertiary amines with aromatic groups (like N,N-dimethylaniline), we have seen much lower background absorbance above 210 nm. In applications needing low-UV backgrounds—pesticide or pharmaceutical residue analysis—this property single-handedly keeps the baseline flat. Product consistency is also easier to maintain, since cycloaliphatic amines pick up less atmospheric contamination and photolytic degradation, causing fewer jumps in detector response between batches.

    Meeting User Demands: Collaboration Beyond Chemistry

    Feedback from analytical labs matters to us. We talk directly with HPLC teams that use our N,N-Dimethylcyclohexylamine for amine-modified mobile phases. Their use cases drive our QC priorities: for example, minimizing trace formamide (a troublesome impurity for LC-MS/MS work), or limiting ionic residue levels. When a big pharmaceutical client moved to sub-2 micron particle columns, they reported increased pressure for reduction in UV baseline wander; after tracing mobile phase add-back, we engineered a two-stage microfiltration into our filling suite, cutting down particulate sources even further.

    Another key learning: users working in regulated environments—GMP pharma, pesticide residue analysis, environmental monitoring—must produce method validation records. To support this, we supply not just a certificate of analysis with batch, but a full analytical data package on request. Our plant keeps these QA records, including chromatograms and purity traces, archived for more than a decade. This is not about paperwork; troubleshooting an out-of-spec run means retrieving those records, down to the time and instrument used on each lot.

    Packaging Approach, Driven by Real Needs

    A big difficulty with amino reagents is avoiding atmospheric pickup, especially dust, water, or airborne acids. Our packing and logistics teams handle these details with the same care as batch synthesis. We use amber, inert containers for packaging, with vapor-tight, tamper-proof seals, and fill in environment-controlled rooms. After years of complaints about container leaching leading to trace contamination, we phased out certain plastics and went to borosilicate only for smaller shipments. Lot numbers and production dates go onto every label—no generic repacks or unlabeled bottles.

    Stability inspections don’t get skipped. We have a protocol for periodic testing of retained lots up to and beyond expiry. If storage affects performance (as can happen with desiccant lapse or packaging breach), we retrofit our processes. A few years ago, a customer’s in-house testing flagged minor residue buildup on stoppers; that led our team to overhaul stopper material and introduce double-sealing on large-volume drums. Each adjustment comes out of dialogue with actual laboratory users.

    Respecting the Safety and Handling Factor

    N,N-Dimethylcyclohexylamine requires sensible handling, both for operator safety and to maintain its HPLC-grade qualities. We take worker protection seriously. On our lines, PPE use is non-negotiable, and we provide well-ventilated work areas, proper eye protection, nitrile gloves, and SCBA setups for bulk handling. All workers are trained on handling organoamines, their reactivity with acids, and basic first aid protocols. These safety policies echo into the labs: we supply clear instructions for safe transfer and storage, and advocate secondary containment for all high-grade lots.

    Shipping gets planned around real hazards, not theoretical exemptions. If a geographic region calls for special hazard declarations or insulation for varying temperatures, we adopt those requirements rather than seeking shortcuts. Volatility stays manageable given our product’s boiling point, but leak prevention and tamper security are critical—once an organoamine shipment is compromised, it simply does not get repackaged or reused.

    The Value of Direct Manufacturer Relationships

    Having control over every stage from synthesis to shipment gives our users something traders can’t: answers rooted in firsthand production experience. If anomalies show up in a chromatogram, we can retrace steps all the way from feedstock to packaging, looking for the root cause. We don’t point fingers at a network; each product bottle is our responsibility. This reduces guesswork and resolution times, especially when working with regulated labs on urgent timelines.

    Over time, we’ve built relationships with method developers and QA chemists who don’t just want a bottle—they want a knowledge partner. We’ve held joint investigations into source variability, pro-actively tweaking our production to respond to shifts in reference standards or international regulatory specs. Our goal is not just to deliver a specification, but to help users anticipate and resolve the unforeseen quirks and problems that come up when pushing HPLC boundaries.

    The Role of N,N-Dimethylcyclohexylamine in Method Development

    Researchers choose N,N-Dimethylcyclohexylamine for its unique impact on chromatography selectivity. The molecule’s tertiary amine group donates moderate base strength, giving improved peak management for acidic analytes, while its cyclohexyl backbone avoids interference found in aromatic-based amines. This is especially relevant in pharmaceutical and environmental residue analysis, where trace separation and resolution of close analogues matters.

    Over time, labs come to value our product’s batch stability. The compound’s consistent retention behavior reduces the number of re-calibration runs required. Method validation gets easier, with reduced baseline drift and more reproducible run-to-run profiles. This proves out over hundreds of runs—what stays below the detection limit determines not just assay success, but regulatory acceptance.

    Our product finds frequent use as a mobile phase modulator, particularly in reverse-phase HPLC. It adjusts selectivity for base-sensitive columns and keeps separation lines sharp without adding UV noise. Our laboratory trials alongside user feedback proved its particular efficiency in suppressing tailing for carboxylic acids and weakly retained pharmaceutical intermediates. For labs running at the edge of quantitation thresholds, this can mean the difference between a successful QC assay and a rework order.

    Committing to Improvement, Responding to Industry Shifts

    Our production philosophy adapts as analytical techniques evolve. The rise of UHPLC and hybrid MS detectors forced us to test and improve for even lower noise. As regulatory standards shift toward sub-ppm and low-picogram reporting, we break down and analyze our own pipelines for cross-contamination risks undetectable ten years ago. We don’t lean on static certifications—each input material and storage protocol is under constant reassessment. If a new trace impurity appears on wider market, we source inputs differently or overhaul our distillation sequences as needed.

    Our chemists participate in industry roundtables and consortia discussing emerging contamination threats, such as PFAS or newly recognized mobile phase interferences. We take knowledge from these forums back to production, often tweaking processes to shut down potential liability before it reaches the user. These changes are recorded and validated by observed reduction in batch rejections and increased adoption by high-throughput contract labs.

    Beyond Product Supply: Supporting a Knowledge Ecosystem

    Direct communication matters. We answer technical questions promptly, whether it’s a quick clarification on storage conditions, or an in-depth discussion about an unexplained shift in analyte recovery. Our support staff sits near the chemists, the QA team, and the logistics hub—so getting a solid answer doesn’t require a drawn-out shuffle between disconnected departments. Analysts at all experience levels call for help with column fouling, new method validation, or clarification about certificate data.

    We prioritize not only making a pure molecule, but sharing knowledge on how to get the best from each bottle. If a customer needs help adjusting mobile phase pH or optimizing flow rates based on experience with our product, that support is open. We’ve even run joint method trials to establish workarounds for recurring LC issues where other amines failed to deliver.

    Building trust with our users means showing up at conferences and responding to field results, not hiding behind a generic certificate. We see our HPLC grade N,N-Dimethylcyclohexylamine not only as a product, but as an integral component in successful chromatography. Engagement with active users closes the feedback loop, steadily pushing the improvements that keep analyses robust as science evolves.

    Summary of Distinguishing Factors

    N,N-Dimethylcyclohexylamine for HPLC, as manufactured in our operation, stands out for purity, batch traceability, hands-on support, and adaptability to user demands. Years of investment in real-world observation, dialogue with lab analysts, and proactive process upgrades have shaped a product that earns trust not just on certificates but through lived experience at both bench and plant. Our users don’t accept compromises and neither do we—each step from synthesis, packaging, to customer support reflects that commitment. The compound’s low UV absorbance, high hydrolytic stability, and reliable supply ensure that chromatographers can focus on results instead of reagent guesswork. Choosing this amine is more than picking a chemical; it is a partnership grounded in technical validation and continual improvement.