West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

N-Hexylamine hydrochloride

    • Product Name N-Hexylamine hydrochloride
    • Alias Hexan-1-amine hydrochloride
    • Einecs 258-847-9
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    143485

    Product Name N-Hexylamine hydrochloride
    Chemical Formula C6H15N·HCl
    Molecular Weight 137.66 g/mol
    Cas Number 638-39-5
    Appearance White to off-white crystalline powder
    Melting Point 207-210 °C
    Solubility In Water Highly soluble
    Purity Typically ≥98%
    Storage Conditions Store at room temperature, tightly closed
    Ph 1 Solution 4.5-6.5
    Odor Ammonia-like
    Synonyms Hexylamine hydrochloride; 1-Aminohexane hydrochloride

    As an accredited N-Hexylamine hydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing N-Hexylamine hydrochloride (Sigma Aldrich, 25g) is packaged in a clear, sealed glass bottle with a labeled chemical-resistant screw cap.
    Shipping N-Hexylamine hydrochloride (Sigma Aldrich/Merck/TCI Chemical Grade) is shipped in tightly sealed containers, protected from moisture and light. Packaging adheres to international chemical safety standards, labeled for laboratory use. The chemical is shipped as a solid, with accompanying Safety Data Sheet (SDS), and typically dispatched via ground or air transport in compliance with relevant regulations.
    Storage N-Hexylamine hydrochloride should be stored in a tightly sealed container at room temperature (15–25°C), protected from moisture, heat, and direct sunlight. Ensure it is kept in a well-ventilated, dry area away from incompatible substances such as strong oxidizers and acids. Follow manufacturer's guidelines and local safety regulations for chemical storage, and label containers clearly.
    Free Quote

    Competitive N-Hexylamine hydrochloride prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    N-Hexylamine Hydrochloride: Direct From the Manufacturer’s Perspective

    Hands-on Experience with N-Hexylamine Hydrochloride

    Every batch of N-Hexylamine hydrochloride coming out of our reactors carries years of production experience. In the lab, the transformation from raw amine into its hydrochloride salt looks straightforward. On a plant scale, things get more interesting. Strict control over exotherms, effective drying, and attention to the possible presence of byproducts from the neutralization step turn a simple-looking procedure into a disciplined process. We use a proprietary synthesis route that keeps color and impurity levels low, delivering material with a crisp crystalline form. The finished product arrives as a white, free-flowing powder, something our chemists have worked hard to achieve batch after batch. This is not a result of luck; it reflects repeated process optimization and many hours on the floor.

    Product Model, Specifications, and Quality Focus

    Our current standard offering is the 99% pure N-Hexylamine hydrochloride, model HA-08. The material comes with a moisture content below 0.3% and low residual amine, which means easy handling and a low risk of caking during storage. Yield consistency is something we monitor with each lot. Any deviation in melting point, color, or particle size distribution triggers a deeper investigation, not just a simple pass/fail check. More than once, we have caught shifts in purity related to minor valve leaks or an unnoticed blip in acid flow control. To many, a clean certificate of analysis is a line on a datasheet; to us, it is a reflection of the plant crew’s attention to the thousands of details each week.

    We avoid relying solely on in-house standards. Our analytical lab uses both HPLC and NMR comparisons with industry references. Samples occasionally go out for third-party verification, and our process has picked up minor batch contamination missed by rapid tests. Lab technicians check for organic byproducts from process reagents and trace metal impurities. It’s not all about the expected numbers; sometimes, it’s the subtle hints on the spectra that spark a conversation back at the control panels.

    Common Uses Drawn from Practical Application

    Most of our N-Hexylamine hydrochloride lands with custom synthesis and R&D teams. Medicinal chemists look for an amine source that reacts cleanly in salt formation and alkylation steps. Having run hundreds of conversion reactions ourselves, we appreciate why purity tails off when water to amine ratios are out of line or when acid dosing drifts. Bulk drug intermediates make up a second group relying on our material. Here, the hydrochloride salt’s solubility in water shapes downstream fermentation or separation steps. Each month, we hear from teams finetuning formulation—trying to minimize free base loss or reducing dissolution time in aqueous layers. Their practical feedback often nudges minor tweaks in our protocol.

    Occasional projects put N-Hexylamine hydrochloride in dye synthesis, where the amine chain length helps tune color fastness and pigment compatibility. Agrochemical labs value the hydrochloride for preparing certain herbicide analogues. Once or twice a year, a polymer researcher will try our salt as a functional group carrier or chain extender. From years of fielding technical calls, we see the same worries crop up. Will a slightly higher chloride content mess up their stoichiometry? Will an off-white cake trace back to a rare lot of base? Usually, the answers go back to our manufacturing logs, not theoretical specs.

    Comparisons: What Makes It Different From Other Amines and Salts?

    Working with simple alkylamines shows how small changes in structure swing reactivity. N-Hexylamine hydrochloride – C6H15N•HCl – brings a mid-length chain, longer than butyl but shorter than octyl. This length doesn’t just shift melting or boiling points. It changes how the salt dissolves, partitions, and interacts in multi-phase systems. In water, hexyl derivatives bring a touch more hydrophobic push; in organic solvents, their behavior bridges gaps between neighbors like propyl and octyl analogues. Customers who once tried n-butylamine hydrochloride and found it too volatile or low-boiling switched to hexyl for its higher handling comfort.

    Every amine salt has quirks, and overproduction years, we have learned them well. For example, methylamine hydrochloride has far greater volatility and is much more inclined to form dust. With hexyl’s greater mass, you get a powder that is easier to weigh accurately and is less hygroscopic under normal lab humidity. Isopropylamine hydrochloride, by contrast, offers lower toxicity but at the cost of lower chain length usefulness in certain alkylation reactions. Dodecylamine hydrochloride’s unwieldy hydrophobic profile makes it ill-suited for most aqueous chemistry. In a sense, N-Hexylamine hydrochloride sits in the practical middle, where it can function both as a manageable lab reagent and as an ingredient for larger scale processes. Bulk users confirm this in their blending and extraction workups.

    Over time, our team ran side-by-side trials using different amine hydrochloride salts for a range of cyclization, quaternization, and substitution steps. Even at the bench, color purity, odor profile, and salt stability set each one apart. Hexylamine hydrochloride consistently gave cleaner threads of product in alkylation, avoiding the greasy residues left by its heavier cousins. You wouldn’t reach for aniline salts for these jobs—too electron-rich, prone to oxidation, and susceptible to trace metal chelation. Hexylamine’s straight-chain, primary character makes it a staple for predictable, repeatable chemistry. Every cycle through the plant exposes new nuances but reinforces why users return to this familiar salt.

    Real-World Storage and Handling: Getting Away From the Books

    Brochures and data sheets can only go so far. Our factory crews shovel, weigh, and pack tonnes of N-Hexylamine hydrochloride every year, so we see firsthand what goes wrong and what holds up. Poly-lined drums with tight seals consistently beat open-topped bins, especially in humid months. Product left unsealed for more than a day can clump, even with the best desiccation. Some users ask if glass bottles would be better in high-purity batches. Glass minimizes static but brings breakage risk in larger volumes. We moved toward double-lining and resealable bulk bags after customer trials highlighted spills and moisture gain when single barriers failed.

    For smaller scale laboratory storage, amber glass helps limit slow yellowing. Not every lot is used up in a few days, and even the purest powder picks up hints of haze if exposed too long on the bench. There’s no shortcut around airtight containers—those who try to cut time with flimsy caps usually call back in a month asking why their salt caked. It’s a mundane problem, but constant handling means we catch these problems quickly, making adjustments batch by batch.

    Process Safety and Environmental Points Learned Over Repeated Operation

    Our solvent handling and waste recovery teams have tuned the entire N-Hexylamine hydrochloride process to minimize amine loss and acidic off-gas risks. Trapping volatile N-hexylamine before and after salt formation is a lesson learned the hard way; early setups lost grams per batch, and anyone on the floor caught the sharp odor. Switching scrubber media cut emissions and made for better working conditions. Those running their own neutralizations notice that uncontrolled release brings regulator attention, so robust scrubbing and closed transfer loops matter at every scale.

    Spent mother liquors still hold dissolved product, so our separation steps get run in sequence—liquid phase decanting, then crystallization at carefully lowered temperatures, and finally a wash-down with cold solvent to maximize recovery. These steps rose out of both yield and waste audits. Waste acid goes for neutralization and further treatment. Where a standard plant might vent to atmosphere, we route streams through multistage absorption towers before discharge. No one on our team wants to face local environmental panels with shady records; clean audits support both trust and a straightforward future.

    Building Trust With the End User

    Years in the manufacturing trade show that it is not the spec sheet that drives long-term relationships, but the regularity with which users get what they expect—and the way issues get solved when expectations aren’t met. Any time a user reports a stuck filtration, haze in their solutions, or lower subprocess yield, our first instinct is to reference not just the batch certificate, but field notes from that production week. The times we caught subtle problems in drying—an offset tray fan, a drift in humidity—serve as reminders that problems don’t always show up on paper.

    Our sales and technical support lines have heard it all: sudden color shifts, unexpected exotherms, handling difficulties traced back to overlooked storage routines. Every ticket and customer call leaves a direct impact on the tweaks we implement. Once, a decade ago, we thought less about particle size—until a repeat customer’s automatic dispenser clogged. Now, we set tighter sieving and mechanical agitation parameters. These are not regulatory moves but real problem-solving steps grounded in user experience.

    Supply Consistency and Forward Planning

    Manufacturing has shown that predictability is not just about scheduling, but about anticipating the unforeseen—logistics delays, raw material purity swings, energy price spikes. Each year brings its own surprises. Natural disasters upstream or border controls can hold up both amine base and acid stocks. We pre-qualify multiple suppliers, spend time on supplier audits, and keep longer-than-average buffer stocks. Safety stock is not a theoretical figure; it is a hard number monitored daily by our plant manager, head of logistics, and on-site warehouse team.

    Our bulk users know that delivery hiccups in the middle of a campaign can derail projects or force hasty substitutions. No one wants to swap a proven amine hydrochloride for an unfamiliar batch midway through a critical step. That’s a practical reason we plan outwards not just in weeks, but quarters. Real-world feedback led us to introduce smaller container sizes for pilot labs and bulk totes for integrated plants.

    Supporting Responsible Use and Compliance

    We follow local and international handling directives not just for paperwork’s sake, but because on-the-ground inspections and periodic surprise audits reinforce their need. Our teams go through annual safety training, and those working with N-Hexylamine hydrochloride understand why containment and labeling aren’t just box-ticking exercises—they’re insurance against spills, cross-contamination, and wasted product.

    Some customers ask about documentation for import or lab registration. We track all production back to incoming lot numbers, running auditable logs with timestamps. This gives downstream users confidence that they won’t face regulatory holdups or difficult questions at customs. Any questions about REACH, TSCA, or local listing elicit immediate response, based on years of building compliant production documentation.

    Challenges and Ongoing Improvements

    A few problems show up more often than others. Temperature and humidity shifts can change flow properties, making it clear that what works in a climate-controlled warehouse may behave differently in other regions. Benchtop users sometimes report different handling characteristics from the same lot, and we help troubleshoot these issues on a case-by-case basis. New applications can put unique stress on crystal size, solubility, or purity, pushing us to adapt manufacturing conditions for future lots.

    Customer discussions drive nearly all improvements. Regular meetings with our process engineers identify repeat service tickets: static buildup in large plastic drums, separation time in precipitation steps, and compatibility with cutting-edge solvents or reactants. Each user brings their own challenges and unintentional insights. We’ve improved venting setups, packing liner materials, and internal sampling techniques thanks to industry partners pointing out friction points. No engineer can anticipate every real-world issue; the best upgrades come from fielded complaints and shared experience.

    Commitment to Reliability and Transparency

    We see N-Hexylamine hydrochloride not just as a standard reagent, but as a product shaped by both manufacturing rigor and ongoing user collaboration. Decades spent refining everything from acid dosing to packaging give us unique perspective. Every customer ticket, product inspection, and tweak to batch processing strengthens not only our processes but the trust users place in what leaves our loading bays. The cycles behind each lot—raw stock testing, plant production, third-party verification—reflect more than regulatory compliance. Each step is geared toward building a long-term partnership based on reliable supply, technical support, and honest problem-solving. That’s the practical backbone behind offering N-Hexylamine hydrochloride direct from the manufacturer.