HS Code |
838107 |
| Cas Number | 924-16-3 |
| Molecular Formula | C8H18N2O2 |
| Molecular Weight | 174.24 g/mol |
| Iupac Name | N-butyl-N-(4-hydroxybutyl)nitrous amide |
| Synonyms | BBN, N-Butyl-N-(4-hydroxybutyl)nitrosamine, Butyl(hydroxybutyl)nitrosamine |
| Appearance | Yellow oily liquid |
| Boiling Point | 135-137°C at 2 mmHg |
| Melting Point | -60°C |
| Solubility | Soluble in water, ethanol, and ether |
| Density | 1.027 g/cm³ |
| Storage Conditions | Store at 2-8°C, protect from light |
| Pubchem Cid | 14138 |
As an accredited N-Butyl-N-(4-hydroxybutyl)nitrosamine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging for N-Butyl-N-(4-hydroxybutyl)nitrosamine (Sigma Aldrich, 1 gram) is a sealed amber glass vial with safety labeling. |
| Shipping | **N-Butyl-N-(4-hydroxybutyl)nitrosamine** requires shipping as a hazardous material, typically under temperature-controlled conditions. It is packaged in tightly sealed, chemical-resistant containers, accompanied by safety documentation. Shipping complies with international regulations (e.g., IATA, DOT), ensuring secure handling and transit due to its toxic and potentially carcinogenic properties. |
| Storage | **N-Butyl-N-(4-hydroxybutyl)nitrosamine** should be stored in a tightly closed container under refrigeration (2–8°C), protected from light and moisture, in a well-ventilated, secure chemical storage area designated for carcinogens. Avoid contact with acids, bases, and oxidizing agents. Use secondary containment and clearly label the storage vessel, following all local regulations and institutional guidelines for hazardous chemicals. |
Competitive N-Butyl-N-(4-hydroxybutyl)nitrosamine prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Direct involvement in synthesizing N-Butyl-N-(4-hydroxybutyl)nitrosamine gives manufacturers a unique perspective on what separates a lab-grade chemical from a commodity compound. Unlike intermediaries or traders, working at the source highlights each batch’s identity and challenges, and it allows for discussions beyond a technical specification table.
Sourcing raw materials for this molecule requires diligence. Butylamine and 4-hydroxybutylamine arrive in drums with their own quirks—moisture content, trace amines, and exposure to air during transit all factor into the final quality. Our process begins with strict receiving protocols. We sample and test every delivery to guard against impurities that could generate unwanted byproducts in the final step, increasing background “noise” in assays that rely on extremely high purity.
After establishing baselines, our synthesis takes place under controlled atmospheres to avoid extraneous nitrosation. The nitrosation phase demands not just accuracy in mixing but also careful engineering controls. Venting, pH, reaction temperature, and timing all influence yield and safety; minor deviations result in lost material or increased risk, so constant monitoring is vital. Over many years, operators learn the value of patience—rushing temperature ramps or shortcutting holding times introduces batch-to-batch inconsistency, which challenges reproducibility in downstream research and applications.
Isolating pure N-Butyl-N-(4-hydroxybutyl)nitrosamine illustrates the difference between reliable supply and general chemical procurement. The final product appears as a pale yellow oil or solid, depending on storage and handling conditions. Consistency in this characteristic directly relates to how the process is run. Factors like container material—glass versus HDPE—impact peroxide formation or discoloration. Scientists using the compound in animal studies or toxicology work require documentation of these nuances, which we provide because we oversee the entire synthetic life cycle.
Post-synthesis, purification steps remove excess reagents and byproducts with repeated washes and fractional distillation under reduced pressure. Failure to clear tars and colored fractions can introduce signal interference during GC-MS or LC-MS testing. On occasion, subtle differences arise—some lots develop a faint odor or minor color over weeks at room temperature, usually due to handling during aliquoting. Because we make the compound ourselves, feedback from researchers led us to adopt inert gas blanketing and light-blocking containers even when not strictly required. These practices stabilize shelf life, crucial for longitudinal studies or multi-year projects.
N-Butyl-N-(4-hydroxybutyl)nitrosamine doesn’t serve a broad industrial base like common solvents or oxidizers. Its niche falls mainly in cancer research. Academic and government labs drive demand, typically for controlled studies of urinary bladder or esophageal carcinogenesis in rodent models. Preparing a reliable series of exposures—dissolved in water or administered via gavage—requires batch homogeneity and precise documentation.
We have shipped material directly for projects where analytical windows are narrow and amount per assay small. Results often feed into regulatory toxicology reviews or underpin mechanistic explorations into nitrosamine metabolism. Maintaining consistency isn’t just a matter of pride; disagreements about impurity profiles, stability under simulated storage, or presence of precursor amines can undermine whole research protocols. Over time, our documentation system built on actual process observations serves principal investigators by answering practical questions—how dry the compound is, expected freeze-thaw effects, or residual solvent levels—without vague or evasive language.
Much industry conversation about nitrosamines centers on similarities: common mechanisms, general mutagenicity profiles, or generic syntheses shared among hundreds of derivatives. Experience shows this story oversimplifies things. N-Butyl-N-(4-hydroxybutyl)nitrosamine stands apart due to its dual functional groups and solubility profile. The hydroxybutyl chain increases water dispersibility compared to straight-chain nitrosamines, impacting formulation and dosing accuracy for lab studies.
Many requests come from teams familiar with N-nitrosodibutylamine or N-nitrosodiethylamine; they expect similar storage and handling but soon discover differences. This analog oxidizes faster in air, so freeze-packing and airtight containers mitigate active loss. Residual water from the synthesis step, if left unmanaged, reduces shelf stability, prompting us to rigorously control final moisture levels. Researchers aiming to compare tumor induction rates between analogs need these nuances detailed along with analytical batch certificates to capture comparable endpoints.
Another point raised during years of communication with researchers involves the by-product profile. In producing “simpler” nitrosamines, incomplete reactions may not matter much—trace impurities wash out in baseline readings. N-Butyl-N-(4-hydroxybutyl)nitrosamine’s extra polar group binds many trace contaminants, which show up under routine analytical scans, so each batch runs through expanded columns and at least two organic phase purifications. Our results prove repeatable only with these extra layers, which we maintain despite higher production costs or slightly lower yields.
Scaling up laboratory syntheses introduces new risks. At tens of grams, temperature control drifts and unaccounted-for atmospheric exposure can ruin a batch. Full-scale manufacturing at kilogram quantities throws in even more complexity—thermal gradients, increased potential for off-gassing, and potential for cross-contamination if vessels aren’t fully dedicated or cleaned by validated procedures. For N-Butyl-N-(4-hydroxybutyl)nitrosamine, careful planning keeps each batch isolated, tracked, and documented, with lot numbers tied to every process parameter and raw material lot. Each bottle ships with this lineage in the records, so recipients know what they’re working with and can trace any anomalies.
Some organizations press for “single lot” procurement to simplify downstream reporting, but in our experience, micro-lots enable tighter control. Each set can be quickly pulled, quarantined, or replaced if needed; a problem found post-shipment never propagates throughout regional inventories. Discussions with long-term collaborators reinforce the value of this approach—few appreciate getting a mixed-lot resupply, as subtle variations creep into sensitive experimental endpoints.
Real-world production doesn’t guarantee perfect analytical profiles. QC labs can miss trace peaks if standards are unavailable or certain byproducts elude detection with standard methods. Researchers solving for total nitrosamine content versus specific contaminants benefit from our open reporting of analytical detection limits, not just average purity. Our most experienced team members learned that collaborating openly—providing chromatograms on request and not hiding behind “conforms to spec” disclaimers—builds long-term trust.
Because this molecule serves as an in vivo research tool instead of a finished pharmaceutical or food additive, external standards programs do not set rigid method guidelines. For reproducibility, we routinely run NMR, GC-MS, or LC-UV assessments and share any “outlier” findings even if they fall within generic purity windows. When questions arise about suspicious behavior under new analytical methods, open communication helps us fix lingering process quirks at the source.
Manufacturing N-Butyl-N-(4-hydroxybutyl)nitrosamine comes with responsibility. Its role in inducing malignancies in bioassays means every shipment includes clear documentation—use limitations, disposal advice, and practical exposure warnings. Our experience shows that supplying to professional research institutions, rather than broad commercial channels, vastly reduces misapplication risks. We partner only with teams who demonstrate appropriate approvals, training, and protocols. Requests from unauthorized parties, hobbyists, or non-research applications do not move forward.
Tightly controlling distribution, even when this means turning away business, ensures both safety and maintains our good standing with regulatory and oversight agencies. Compliance walks hand-in-hand with operational transparency. Regular internal audits ensure that our documentation and shipment processes adapt alongside changing environmental, health, and safety standards worldwide. Rather than leaving users to parse vague legal disclaimers, our approach focuses on plain language and accessibility.
Handling production waste forms a major part of day-to-day operations. Each unit of product leaves behind streams containing acidic residues, unused amines, and dilute organic solvents. Our experience points to the necessity of closed-loop systems—recycling solvents where possible, neutralizing acid streams before disposal, and ensuring any hazardous waste is documented by batch and destination. Investing in these systems, despite added expense, delivers a dual benefit: environmental risk reduction and auditability if agencies challenge a disposal record.
We constantly update internal documentation and adjust process flows based on evolving waste regulations. Sometimes this involves changing a solvent or shifting a purification step, with full transparency offered in technical summaries sent with each batch. Over decades, we’ve seen regulations shift considerably; sustained compliance is less about keeping up with the letter of new rules and more about embedding responsible behaviors as part of work culture.
Direct contact with users provides valuable insights. Occasionally, we receive reports of flagged background readings, new instability profiles, or requests for custom documentation on byproducts. We address questions by investigating upstream causes, examining storage history, or checking data from previous lots. This two-way communication leads us to better practices—from changing container types to offering optional additional purification. Decades of feedback have shown that learning from users, rather than only our own lab data, often guides process or quality upgrades.
Sometimes, problems emerge only under unusual environmental conditions, such as extreme humidity in certain research facilities or unexpected delays in customs. We field these issues with on-the-ground troubleshooting—supplying replacement material rapidly, providing fresh documentation, or collaborating on modified handling protocols. By owning every step from synthesis to delivery, we own every potential imperfection, which sharpens our focus on getting the process right rather than passing responsibility down the chain.
Colleagues frequently ask about the differences between this molecule and more familiar analogues like N-nitrosodimethylamine or N-nitrosodiethylamine. Beyond molecular size, the added hydroxy group alters biological and chemical behavior. The compound’s partition coefficient shifts, changing how it disperses in aqueous solutions and cells. Toxicological studies document different pathways of activation and excretion, meaning experimental comparability depends on consistent material and tight analytical controls.
From a producer’s vantage point, synthesis complexity directly shapes error rates. Shorter-chain nitrosamines let operators work a bit faster thanks to less stringent atmospheric controls and simpler purification. Extra functional groups in N-Butyl-N-(4-hydroxybutyl)nitrosamine impose additional checklists: more solvent washing, repeated crystallization steps, and the use of low-UV absorbing storage containers. Each new layer adds cost and time, but operational experience shows these steps consistently improve reproducibility for those who conduct research using the product.
Producing a compound of this character at scale brings recurring technical and operational hurdles. Scaling reactions safely, ensuring purity in a changing regulatory environment, adapting to feedback, and supporting customers globally take more than routine execution. Our practice relies on both well-maintained SOPs and a willingness to review results batch-for-batch. Customizing distribution, tracking shipments, and troubleshooting post-shipment issues at both source and destination keep our teams engaged through the product life cycle.
To handle unexpected demand, we built up source material inventories and established reliable supplier relationships. We continuously refine process controls: automating more steps with real-time feedback mechanisms, using more specific analytical standards, and soliciting verification from independent third parties when new applications emerge. Each of these improvements traces back to real-life process issues—sometimes flagged by our own staff, other times through external collaboration—and embodies a culture of practical problem-solving.
Sourcing material from a direct producer carries advantages beyond product consistency. Years of hands-on synthesis and close cooperation with research groups have given us useful insight into the nuances of N-Butyl-N-(4-hydroxybutyl)nitrosamine—how subtle changes in process can influence usability and reliability, how material history should be documented not only for compliance but for user benefit, and how transparency in problem-solving builds lasting trust. These experiences highlight the difference between simply shipping a chemical and taking responsibility for the entire supply chain.
Overall, this kind of specialty compound teaches one lesson above all: real-world reliability comes from deep practical experience—knowing each variable, understanding user needs on the ground, and maintaining flexibility to improve as challenges arise. Working as the manufacturer, one never takes consistency for granted or assumes the same path suits all materials equally. Instead, every batch brings a practical test of skill, foresight, and commitment to quality, all rooted firmly in hands-on reality.