HS Code |
955562 |
| Cas Number | 2082-22-8 |
| Molecular Formula | C7H13NO3 |
| Molecular Weight | 159.18 g/mol |
| Iupac Name | N-acetyl-D-valine |
| Appearance | White to off-white powder |
| Melting Point | 155-158°C |
| Solubility | Soluble in water |
| Optical Rotation | [α]20D +23° (c=1, H2O) |
| Purity | Typically ≥98% |
| Smiles | CC(C)[C@H](NC(C)=O)C(=O)O |
| Inchi | InChI=1S/C7H13NO3/c1-4(2)6(7(10)11)8-5(3)9/h4,6H,1-3H3,(H,8,9)(H,10,11)/t6-/m1/s1 |
| Storage Temperature | 2-8°C |
| Synonyms | Acetyl-D-valine |
| Ec Number | 218-196-4 |
As an accredited N-Acetyl-D-valine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | N-Acetyl-D-valine (1g) is packaged in a sealed amber glass bottle with screw cap, labeled with product details and safety information. |
| Shipping | N-Acetyl-D-valine (Sigma Aldrich/Merck/TCI, Chemical Grade) is shipped in tightly sealed containers to prevent moisture and contamination. It is transported at ambient temperature unless otherwise specified, with clear labeling for chemical identification and hazard information, adhering to international shipping and safety regulations for non-hazardous laboratory chemicals. |
| Storage | **N-Acetyl-D-valine (Sigma Aldrich/Merck/TCI Chemical Grade)** should be stored tightly sealed in a cool, dry, and well-ventilated area, away from incompatible substances such as strong oxidizing agents. Store at room temperature (15–25°C) and protect from moisture and direct sunlight. Use appropriate chemical containers and avoid contamination. Always follow local safety guidelines and consult the manufacturer’s Safety Data Sheet (SDS) for detailed instructions. |
Competitive N-Acetyl-D-valine prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Some compounds take years of hands-on effort to refine and deliver consistently. N-Acetyl-D-valine stands as a testament to focused process tuning and hardworking teams in the world of amino acid derivatives. Our years spent in storefront labs and large-scale facilities have shown us that every batch has its own character, and only practical experience turns those small differences into reliable, usable product.
Those of us in the chemical manufacturing sphere recognize that quality keeps doors open. N-Acetyl-D-valine’s manufacture doesn’t rest on clever sales talk; it depends on the daily routine of purification, checking crystal form, and avoiding the mistakes that show up only after a few dozen cycles. Our production lines operate with careful attention—each valve turn and pH tweak reviewed in real time before the final white powder leaves our hands.
This isn’t a generic process. N-Acetyl-D-valine has its quirks during acylation: temperature swings, acid-base ratios, and unwanted side-products that end up in filtration. We brought in analytical chemists who cut their teeth spotting racemization or unexpected byproduct formation. It took time to figure out how much vacuum actually helps. Batch after batch, scale-up hiccups taught us to check every mother liquor and keep an eye on melting point drift. You’ll rarely see the same vigilance in products passed through several trading hands.
We deliver N-Acetyl-D-valine labeled by lot and purity, not marketing slogans. Most of our clients over the years came through word of mouth—they knew we didn’t exaggerate assay numbers. Currently, we focus on lots with a minimum 98% purity (by HPLC), moisture usually under 0.5%, and optical rotation matching the D-enantiomer. Each lot comes from a fermentation-derived D-valine, not the racemic or L-form.
Our model packaging fits both bench-scale and pilot runs, with 100g, 1kg, and bulk drums. Our QC staff measure every lot for precise content and known residual solvents—common analytical runs include FTIR and 1H NMR. Once in a while, someone asks for chiral chromatography data, and our records go back years. If the batch falls even slightly out of spec, it doesn’t ship. We’d rather have rework than a return. Lab staff probably hold more pride for low rejection rates than any certificate on the wall.
Not every user fits a template. Research chemists run into N-Acetyl-D-valine while tuning peptide synthesis routes or checking enzyme-substrate specificity. Even seasoned organic chemists have called us about stubborn racemates, or if a reaction behaves differently with D- rather than L-forms. Drug discovery teams experiment with N-acetyl derivatives for structure-activity relationship scans—not only for the final molecule, but for intermediates and metabolic stability work.
We’ve also sent samples for chiral building block libraries and crystallography studies. In agrochemical and veterinary pre-formulation, a few grams of our product were all the difference between a non-starter and a promising candidate. Academics appreciate lot-to-lot consistency, especially for kinetic studies or bioavailability measurements—one less variable in a long chain of unknowns.
N-Acetyl-D-valine pops up in food additive tests, but we’re candid about regulatory status in each region. No one benefits from mislabeling or unclear paperwork, and our quality group tracks documentation for every country it goes to.
The simplest way to describe the difference? We never stop testing. Some sources sell generic N-acetyl amino acids off the shelf, many from mixed production—racemates, L-forms, sometimes even mis-identified material. We focus on enantiomeric purity and rigorous QC, informed by decades navigating not just theoretical chromatography, but the realities of field complaints and process upsets.
Unlike other products that drift batch-to-batch or lose activity sitting in warehouses, our N-Acetyl-D-valine ships quickly after production. That means stability data reflects the true state of the sample when it reaches the customer. We still keep retain samples for nearly every shipment, often in triplicate, ready for re-examination if a partner ever has questions down the line.
We use D-valine as the precursor, so our process minimizes racemization—right from feeding fermentation broth, through reaction, then purification and drying. Testing for L-valine content or residual solvent isn’t just for paperwork; it’s because we’ve seen failed reactions from hidden contaminants, and getting blame shifted back to the manufacturer rarely solves a chemist’s problem. We’ve had situations where a client’s results only lined up after switching to a freshly checked lot of our material.
Many distributors repackage or blend product from multiple sites, which introduces subtle but real batch variability. Our operations run continuous lots, with clear forward and backward traceability. If a contamination event happens upstream, we know not just the date and sequence, but which operator and which equipment handled it. Pre-shipment holds for final verification come standard; plants appreciate fewer surprises after material lands.
For chemists facing solubility puzzles, our tech group has long compiled solubility tables in typical solvents, along with real-world notes about handling the crystalline form. Bags that clump from static? We switched our packaging film years ago, after bench users complained about static charge. For those running into filter clogging, we’ve refined crystal forms and screening during drying, so product moves through even tight-pore filters without hang-ups.
Some labs faced issues with difficult dissolution—D-enantiomers sometimes behave unexpectedly in organic or mixed aqueous solvents. Our technical center now routinely supplies guidance based on years of working not only with our own researchers, but with feedback cycles coming back from multiple continents. We often include those tips with every delivery or upon request.
Regulatory paperwork can bring work to a halt. We’ve learned our customers want every shipping document checked in advance—not only compliance with domestic standards, but with explicit origin and purity details spelled out for customs and regulatory groups. Our approach has always meant fewer cargo delays and easier clearance for approved-use applications.
Downstream, we coordinate with partners during process scale-up, testing product in actual pilot runs to flag incompatibilities as early as possible. This might look like blending trials, solubility snap tests, or impurity stress checks. Our records show plenty of saved batches—knowing in advance which side-product might arise under reaction conditions sometimes prevents lab-scale issues from scaling up into full-blown process breakdowns.
Manufacturing N-Acetyl-D-valine rarely unfolds the same way twice. One production campaign might run smooth, but the next—under different weather or slightly older house solvents—calls for recalibration. Our production logs detail ambient temperature, starting material batch, and even specific distillation lots for solvents. Those adjustments, reviewed month by month, give us the confidence to stand behind every delivery.
Over time, we saw that every minor improvement, whether tightening a pH setpoint or adjusting crystallization timing, translated into practical benefits. Yield went up, downstream purification needed less rework, and fewer out-of-spec notifications reached our phones late at night.
Our team also saw the real consequences of product traceability. Years ago, when a single batch showed a higher-than-expected moisture level, we pulled it from the shipping queue, delaying an entire order rather than risking a customer’s critical test. The disappointment from missing a deadline can be mended; a wasted synthesis can’t. This mindset stays ingrained long after management changes or process upgrades.
Some suppliers mix D- and L-enantiomers, treating both as interchangeable. From practical process history, we know the importance of keeping each enantiomer distinct. Peptide synthesis outcomes change dramatically with the form of valine used: yields, side reactions, and even chiral catalysis shift if there’s an impurity. It matters not just on paper but at the bench. We keep our D- and L-production lines strictly separate, including cleaning validation and in-process monitoring.
The D-enantiomer works differently in biological settings and analytical chemistry. Enzyme specificity varies, and researchers have told us about metabolic tests that failed simply from using the wrong isomer. For pharmaceutical clients pursuing chiral drugs or intermediates, strict segregation and reliable optical rotation data prove essential—missing this in the production chain erases months of discovery effort.
Our long track record comes not from salesmanship, but from consistent performance, straightforward documentation, and an open door to feedback from users who depend on every lot performing as expected.
Chemical manufacturing remains a blend of rigorous procedure and skilled intuition developed through years at the bench. Our staff check each lot not just for numbers, but for physical feel, crystal shape, and basic handling. You’ll often find shift leads walking the line, checking dryers and making small notes, long before an HPLC trace comes off the printer.
Problems sometimes show up in the least-expected way—static clumping, delayed solubility, or an odor that flags a hidden impurity. Experienced techs catch these not because of rigid protocols, but because they remember what a clean batch looks and feels like. It’s this hands-on oversight that ensures the product leaves our gates in top shape, and we treat each customer report, good or bad, as a direct feedback loop into our process.
We’ve found long-term partners not by lowest price but by living up to the promises made and documentation supplied. Our repeat customers know there’s a real person behind every batch, open to a phone call, a correction, or an on-site review if needed.
The chemical industry never stands still, and neither do we. Newer regulations or customer requests push us to keep files up to date and adjust processes as needed. With N-Acetyl-D-valine, advances in chiral analysis and process control have helped us tighten purity windows and reduce rework rates. Staff training evolves—many come with years of wet chemistry experience, and we keep skills fresh with workshops that focus on root cause analysis and manual troubleshooting, not just compliance.
Feedback from real-world users also shapes the process. Calls about color variation or micro-particles prompted us to invest in better filtration and imaging tools. Software-driven traceability logs let us pull up every detail from any lot, giving customers and our own teams better vision into the entire product story.
Our journey with N-Acetyl-D-valine hasn’t finished, and meaningful change takes time. What grounds our work is a simple approach—learn from each run, respect what customers share, and keep product integrity at the forefront of every decision, from raw material sourcing to final shipment.
Many products reach the market through layered distribution systems. Our approach, with direct manufacture and shipment, provides both flexibility and control that third-party models can’t match. When concerns arise—about purity, reproducibility, or documentation—answers come directly from those who made the product, not intermediaries speculating with incomplete information.
Those assurances matter most in fields like pharmaceutical development, life sciences, and advanced materials design. Users rely on predictable, consistent material, and tapping into deep manufacturing experience means fewer variables and less uncertainty in every test or trial run.
Over the years, developed trust between manufacturer and user becomes its own safety net. Fewer surprises downstream, faster improvements upstream. The process never loses sight of the fact that real researchers—real people—stand behind each request for a better, more reliable source of N-Acetyl-D-valine. We remain ready to help chemical and scientific advances by supplying material we know, from our own hands and our own processes, meets the needs of every challenging project.