West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

N-Acetyl-D-penicillamine

    • Product Name N-Acetyl-D-penicillamine
    • Alias NAP
    • Einecs 214-484-9
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    606254

    Chemical Name N-Acetyl-D-penicillamine
    Molecular Formula C7H13NO3S
    Molecular Weight 191.25 g/mol
    Cas Number 22298-22-6
    Appearance White to off-white crystalline powder
    Solubility Soluble in water
    Melting Point 192-196°C
    Pka 3.6 (carboxyl), 9.5 (amine)
    Storage Temperature 2-8°C
    Synonyms D-(-)-2-Acetamido-2-methyl-3-mercaptopropanoic acid
    Chirality D-enantiomer
    Iupac Name 2-Acetamido-2-methyl-3-sulfanylpropanoic acid

    As an accredited N-Acetyl-D-penicillamine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing N-Acetyl-D-penicillamine, 1g, supplied in a clear, sealed glass vial within a labeled, tamper-evident Sigma-Aldrich box.
    Shipping N-Acetyl-D-penicillamine (Sigma Aldrich/Merck/TCI, chemical grade) ships in tightly sealed containers to prevent contamination or moisture exposure. It is typically transported at ambient temperatures unless specified otherwise, with clear chemical labeling and documentation. Compliant with relevant regulations, shipping may include safety data sheets and hazard precautions as required by applicable transportation guidelines.
    Storage N-Acetyl-D-penicillamine (Sigma Aldrich/Merck/TCI Chemical Grade) should be stored in a tightly closed container, in a cool, dry, and well-ventilated area, away from incompatible substances such as strong oxidizers. Protect from moisture and light. Recommended storage temperature is 2-8°C (refrigerated). Always refer to the Safety Data Sheet (SDS) for detailed storage and handling instructions.
    Free Quote

    Competitive N-Acetyl-D-penicillamine prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    N-Acetyl-D-penicillamine: From Factory Floor to Laboratory Bench

    Reliable Supply Stems from Deep Manufacturing Experience

    In the chemical manufacturing industry, long-term supply relationships depend on transparent processes and continual attention to detail. N-Acetyl-D-penicillamine occupies a trusted spot among our main products, and its success comes from years spent refining our methods for consistent purity and batch reliability. Our team develops each lot from raw materials we select ourselves. Past experience with various routes, including acetylation steps and refined crystallization, taught us how small tweaks can make a difference when sensitive end uses are involved. We’ve implemented redundancy in critical control points, not just to meet pharmacopoeial requirements but to anticipate unforeseen shifts in material variability. That includes investments in analytical verification equipment and in training technicians to spot anything out of the ordinary before a product leaves the plant. All incoming and outgoing batches face an array of analytical tests, including chiral purity and residual solvent analysis, with results documented for full traceability.

    Production Nuances Set Our Material Apart

    Our history producing N-Acetyl-D-penicillamine taught us where to invest for better downstream outcomes. Handling the acetylation process on an industrial scale requires temperature controls and rapid pH adjustments, as even a brief drift results in troublesome by-products or inconsistent yields. Chiral separation on the D- isomer requires special attention; contamination with L- isomer always risks undermining end-use reliability. Years of pilot-scale trials led to dedicated vessels and flows designed just for ultra-pure grades. Special mixing profiles make a difference when scaling up, so we keep our blending speeds and order-of-addition parameters close to the chest. These methods help us produce batches with reproducibly high chemical purity and a low-enough moisture content that packaging remains stable through transport.

    Understanding Specifications from the User Perspective

    Every lot leaves with certificates of analysis detailing chiral purity, residual solvents, and trace metal content. Most of our customers focus on chemical purity above 98 percent, with optical rotation values that match published literature. Low iron and heavy metal readings proved especially important when our customers sought API-grade material for pharmaceutical synthesis. During a period of particularly wet monsoon seasons, we learned firsthand how trace water content can increase during milling and packaging. Investing in humidity-controlled environments for post-reaction handling became a priority, so our customers can count on consistent moisture readings.

    Particle size distribution, while less a concern for strictly solution-phase syntheses, matters for anyone incorporating the material into solid formulations. Our grinding and sieving lines respect common requests for uniform powder below certain mesh sizes, based on the observations that larger or uneven crystals slow dissolution in process tanks. Feedback from production chemists prompted early investments in air classification and fine-mesh screening to minimize clumps and uneven flow.

    Applications Shaped by Trusted Quality

    Among the most common uses, N-Acetyl-D-penicillamine acts as a precursor or intermediate in the preparation of pharmaceuticals for chelation therapy. Our partners in the pharmaceutical and veterinary industries count on consistently high purity for further transformation into finished products—there is little room for off-specification delivery. Suppliers of diagnostic reagents also incorporate our product for specific test kits that require reliable D-enantiomer content to ensure accurate readings in clinical applications.

    Despite competition from larger multinationals, our reputation has grown in niche therapeutic areas requiring bespoke control of impurity profiles. Some clients utilize our N-Acetyl-D-penicillamine during advanced peptide synthesis, where even minor isomeric contamination triggers product loss or lower yields. Others, in the research field, selected our material for redox studies, since batch-to-batch stability saves days of troubleshooting reactive intermediates.

    Comparison with Market Alternatives and Differentiation

    Talking to customers across pharmaceutical, research, and industrial segments, we see a wide spectrum of alternate suppliers. Some source from high-throughput producers that focus on bulk output but don’t always control for subtle impurity levels. Material made with cost-driven, shortcut acetylation can miss the mark on isomeric excess or residual starting material, depending on how tightly the process is managed. Other products on the market may stem from resellers who offer little real-time accountability, forcing buyers to navigate complex chains of custody for quality concerns. End users frequently report inconsistent handling or traceability, which complicates regulatory compliance and makes root cause analysis more challenging when issues pop up.

    By contrast, our approach prioritizes vertical integration and internal data collection over outside dependency. That means upkeep on in-house analytical capabilities, with full transparency for impurity profiles, moisture, and optical properties. Third-party labs occasionally catch mismatches between labels and actual measured quality in broad market samples—only close attention to process oversight can address this. Years of feedback taught us to validate every equipment recalibration against reference standards, instead of assuming variance stays within “normal” boundaries.

    Addressing Challenges and Potential Solutions

    Over the years, cycles of customer demand exposed us to pressures, from supply chain delays on raw inputs to tighter import restrictions. Agility in sourcing plays a role; direct relationships with raw material producers mean priority allocation, especially during periods of restricted trade or shipping congestion. Some clients have real worries about the long-term stability of their projects if forced to switch suppliers midstream. That pushes us to invest not just in inventory, but in transparent documentation, longer-term contracts, and technical support for smooth transitions.

    Environmental management remains a priority, given the nature of waste streams from penicillamine synthesis. Rather than relying on offsite disposal, our plant reclaims solvents and neutralizes effluent in-house, guided by learnings from both regulatory audits and industry working groups. Our chemists monitor emissions and waste at every stage, since subtle changes in upstream processing ripple through to environmental impact. Regular review of green chemistry literature prompted us to trial less hazardous reagents for acetylation, with an eye on both safety and product profile.

    Another practical concern for our team is protecting workers and maintaining reliable output during periods of extreme weather or supply interruptions. Close links between operations and safety staff, along with on-site stocks of critical spares, buffer against sudden downtime. Layered communications protocols allow us to escalate maintenance questions before they affect scheduled deliveries. Training new hires in hands-on process troubleshooting prevents small errors from cascading into larger production setbacks.

    User Feedback Shapes Every Batch

    Years in production revealed that feedback does not just belong to the troubleshooting process; it can reshape protocols, documentation, and even equipment upgrades. We’ve built a habit of collecting incident reports from both our logistics partners and end users. Reports of minor discoloration or trace odor prompted tweaks to final filtration steps. Concerns about pack size and shelf life led us to offer air-tight, customizable packaging, rather than locking customers into a fixed format. Some projects needed ultra-small pack sizes for on-demand research, while ongoing manufacturing required bulk, but with the same batch traceability.

    Cross-disciplinary consultations—where chemists, QC analysts, and applications experts talk through new findings—often highlight the complexity in end uses. Not all applications treat impurity profiles the same way: pharmaceutical synthesis triggers different thresholds for process impurities than advanced academic research into new biologically active compounds. Building real collaboration with customers keeps us learning beyond our own laboratory.

    Regulatory and Quality Management Insights

    Regular audits test the depth of our quality system more than any single batch analysis. Since N-Acetyl-D-penicillamine often enters regulated flows—pharmaceuticals, diagnostic kits, and exported research supplies—the audit trail behind every shipment matters. For instance, certifying compliance means keeping comprehensive data logs from raw inbound materials through to finished release, not just occasional spot-checks.

    Feedback from regulatory inspectors and third-party quality audits taught us that even small changes in documentation can smooth the path for customers’ own submissions. That might mean refining batch records so every raw input timestamp is legible and associated with a unique identifier, or making stability data available to support storage claims. Some regions demand extra certificates based on heavy metal screening or residual solvents, so our paperwork evolves to match those expectations. This continuous improvement cycle gives our partners less to worry about at their next audit.

    Commitment Rooted in Integrity and Practical Experience

    No shortcut ever substitutes for long-term trust. In chemical manufacturing, credibility comes from showing up each day with routine process records, open communication, and equipment that keeps up with demand. Every reformulation or process change faces rigorous internal review and trials, given the weight placed on batch-to-batch uniformity in demanding fields.

    Laboratory and scale-up staff work shoulder-to-shoulder to troubleshoot, so plant operators understand why a tweak in reactor temperature profile can change both yield and impurity distribution. These lessons, built from setbacks and successes alike, shape not just what appears on our spec sheets but how we solve new challenges.

    Looking Forward: Solutions Driven by Expertise, Not Hype

    Continual investment in staff and infrastructure sets the pace for future improvements. New reactors and enhanced purification systems do more than keep us competitive—they reduce bottlenecks and help us meet tighter delivery schedules when customers need quick scale-ups. Data-driven decision-making, based on years of retained process documents, lets us anticipate problems and make evidence-based changes rather than chasing transient industry fads. It also helps when evaluating requests for custom modifications, such as alternative lot sizes or impurity targeting, to provide honest feedback about what’s feasible and where risks may develop.

    From initial procurement to each packed shipment, every gram of N-Acetyl-D-penicillamine reflects long-term effort, discipline on the factory floor, and a constant curiosity about how people put the material to use. Our focus stays on helping customers thrive, not just by meeting published specifications but by learning from their workflows, regulatory drivers, and technical hurdles. We see each order not as a transaction, but as the next step in a relationship built on honest feedback and practical support.