HS Code |
517168 |
| Name | Laurdan |
| Chemical Formula | C21H21NO |
| Cas Number | 76543-13-2 |
| Appearance | Yellow powder |
| Solubility | Soluble in ethanol, DMSO, DMF |
| Excitation Maximum | 350 nm |
| Emission Maximum | 440 nm (gel phase), 490 nm (liquid phase) |
| Application | Membrane fluidity probe |
| Storage Temperature | -20°C |
| Synonyms | 6-Dodecanoyl-2-Dimethylaminonaphthalene |
| Absorption Maximum | 369 nm |
As an accredited Laurdan factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Laurdan (chemical grade, 25 mg) is packaged by Sigma-Aldrich in a small, amber glass vial with a secure screw cap. |
| Shipping | Laurdan is shipped by Sigma Aldrich, Merck, and TCI under regulated conditions. This fluorescent dye typically requires shipment at controlled temperatures, often on dry ice or with cold packs, to preserve its stability and protect from light. Packaging complies with international regulations for hazardous chemicals, ensuring safe and prompt delivery. |
| Storage | Laurdan (Sigma Aldrich/Merck/TCI Chemical Grade) should be stored at −20 °C, protected from light and moisture to maintain its stability and fluorescence properties. Keep tightly sealed in an amber vial or container and in a dry, well-ventilated area. Avoid repeated freeze-thaw cycles and exposure to air, as Laurdan is sensitive to oxidation and hydrolysis. Use desiccants if possible. |
Competitive Laurdan prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
After years at the lab bench and afternoons spent overseeing syntheses that span from the gram scale to the pilot reactor, I have developed a deep respect for chemical products that earn their reputation through precision and reliability. Laurdan, which we produce in our own facility, stands out among biophysical probes known for their clear and dependable performance in membrane research. Chemists and researchers frequently ask us about quality differences, purity profiles, and batch dependability. We’ve seen a lot of “just good enough” product drift around the market, and we won’t have it. Our Laurdan is manufactured from the ground up in-house, with each batch tested for physical characteristics, melting point, emission spectrum, and solubility—no spot checks, no gaps in accountability.
We’ve anchored our Laurdan production around the compound 6-dodecanoyl-2-dimethylaminonaphthalene. This molecule integrates as it should into lipid bilayers, thanks to its tail group and stable aromatic core. We offer Laurdan at a minimum purity of 98% by HPLC, as determined by our lab. Every lot is supported by a spectrum of analytical data, emailed directly to researchers, offering concrete figures: the expected absorption maximum at 360-370 nm, with emission peaking between 420 and 550 nm, depending on local lipid order. Particle size falls within consistent micron range, ensuring homogeneous dispersion in both stock solvents and model membrane environments. Our technical staff monitor water content by Karl Fischer titration and residual solvents by headspace gas chromatography, not because it’s trendy, but because customers have told us stories of failed experiments from batches they bought elsewhere that carried over unwanted volatiles.
The surge of interest in membrane dynamics and cell surface characterization has made Laurdan almost a household name in physical chemistry. In our facility, requests often come from physicists charting lipid raft domains, or neuroscientists mapping synaptic membrane order in brain tissue. We see Laurdan at work every day: dissolved in ethanol for multilamellar vesicle systems, or sonicated with synthetic phosphatidylcholine lipids before measurement. Laboratories rely on Laurdan’s spectral sensitivity to changes in lipid packing—tracking “generalized polarization” changes that flag phase separation, fluidity shifts, and even apoptosis markers.
Our staff have worked directly with researchers to troubleshoot stubborn background noise in GP measurements. Sometimes the culprit lies with subtle impurities or fluorescent contaminants that sneak into poorly controlled syntheses. We purge those risks with aggressive purification and batch tracking. Laurdan is not a “just add water” product—users demand clear baselines, absence of exogenous fluorophores, absence of ghost peaks on TLC, as validated by our own technicians, not passed along from another handler.
I have seen many biophysical probes marketed at conferences, from Prodan to Di-4-ANEPPDHQ. They each work in the right scenario, but Laurdan persists for a reason. Its long-chain tail seats securely in lipid bilayers, so it reads the local environment with very little back-and-forth movement. Prodan, by comparison, drifts more; in practical use, that drift produces broader emission profiles and inconsistencies, especially where lipid packing densities run high. Users of Di-4-ANEPPDHQ brag about red-shifted spectra, but report photobleaching and toxicity concerns in the literature. Laurdan’s stability in vitro and in living cell imaging makes it the mainstay for time-course measurements, repeated scans, and cells you can’t afford to lose after a few minutes of excitation.
Researchers who contact our technical lines often want comparison data—not just tables torn from catalogs, but hands-on evidence. Our own comparative fluorescence readings make it clear: Laurdan delivers the sharpest distinction between gel-phase and liquid crystalline membranes, with the least spectral overlap. Customers concerned about aqueous insolubility or poor miscibility find that our Laurdan batches dissolve cleanly in standard buffers after a short vortex. This reliability matters in multi-well plate experiments, where pipetting artifacts and precipitation headaches can derail a week of incubation work.
I spend a lot of time walking the production line with our process chemists, and there’s no secret shortcut to a consistently high-yield Laurdan synthesis. We take care sourcing the base naphthalene feedstock and keep every reaction step under batch record control. Temperature and pH swings are documented in real time, with samples pulled after key additions. Research scientists sometimes ask why the same product can look different from one supplier to the next. In my experience, poor solvent removal and incomplete crystallization account for most of the yellowing, haze, or off-odors seen in samples ordered from less specialized handlers.
We keep our focus on robust purification, even when that means running double vacuum distillations or extended recrystallizations. On a few hot, humid days, we’ve rejected finished product that fell outside our moisture specification—even though “technically” it might have passed in a less rigorous facility. I remember one run last year, scheduled for a tight timeline, where we lost yield just to nudge the water content under 0.3%. That cost margin, but it protected reputation and assured returning customers that their membrane prep wouldn’t be ruined by solvent leaching or unplanned side reactions.
Every Laurdan shipment from our plant connects directly to a full certificate of analysis, not just for the major analytes but for batch-to-batch absorption/emission curves, chemical purity, and log sheets of synthesis date and operator name. We overwrote the old “generic” lot numbers some competitors use and built a digital tracking system where clients can scan the batch code on each vial and retrieve the production history.
No researcher wants to hear that their results differ because of a quiet sub-tier vendor shuffle or a poorly labeled stock bottle. Our team learned from customer feedback spanning nearly two decades—membranes prepared with Laurdan from our own reactors give repeatable signals, batch after batch, with low background and predictable partitioning across a range of lipid compositions. We’re happy to supply example data, raw analytic traces, and even post-shipment sample checks for labs running into unplanned anomalies. There’s nothing theoretical about “supply chain transparency” in our world; it lives or dies by the trust of people staking their own thesis projects or grant funding on a reliable probe.
The drive to secure valid results never lets up, given the pace of new discoveries and the steep price of a failed membrane assay. Laurdan’s standing among membrane researchers does not rest on brand hype. It comes through years of head-to-head trials in real labs across the world—whether at the single vesicle fluorescence microscope or bulk sample cuvettes. We’ve heard from graduate students, fresh to GP imaging, and from tenured scientists refining their models of membrane order in cell death or raft formation.
Some of our customers run Laurdan with advanced time-resolved fluorescence setups, looking for nanosecond lifetimes to pick out more subtle shifts in membrane microdomains. Our production chemists track every impurity that might muddle those signals. We know from published reports and conversations with principal investigators that even minor contaminants can lead to quantifiable error, blurring the difference between healthy and disrupted tissue. That’s a responsibility we carry in every gram shipped.
With hands-on feedback, we have developed protocols for dissolving, handling, and storing Laurdan that make sense for standard and nonstandard experiments alike. Many customers have run into solubility problems with Laurdan from sources that skip thorough drying or leave product agglomerated into hard-packed chunks. Our in-house protocol encourages gentle warming and addition of molecular sieves for stock solutions needing storage longer than a week, with full solvent compatibility guides distributed to regular clients.
We see common technical inquiries relate to photostability, solvent carryover, or background autofluorescence. In one recent example, a research group established cleaner, longer-lived Laurdan signals in confocal imaging after switching from a bottled ethanol stock to our dry-transfer vials and adopting an anhydrous preparation. That kind of direct troubleshooting comes out of years spent handling both micro and macro scale fluorescence measurements ourselves, often alongside the academic labs we support.
We keep our finger on the pulse of real users’ needs and don’t just follow protocols from ten years ago. The ramp-up in super-resolution microscopy and machine learning for image analysis puts tougher demands on fluorescent labels. Laurdan from our production line must deliver uncompromising sharpness and minimal drift, batch after batch.
Our lab team meets weekly to review not just yields and QC metrics, but firsthand reports from customers documenting their experimental outcomes. These practical insights trickle straight into how we tweak purification schedules, impurity thresholds, and solvent handling. We never treat production as just another remote chemical catalog entry. For us, supply means direct accountability—backed up by shared knowledge and hands-on support that delivers real research value, not just another invoice.
As the original manufacturer and not another relabeling operation, our approach hinges on years of technical discipline, real user feedback, and a hard-earned understanding of what research labs actually need. We know Laurdan’s strengths—sharp spectral response, proven repeatability, effective membrane partition—and also keep driven by every leftover challenge in sample prep or measurement.
If your project hinges on fine distinctions in membrane order, on fluorescence signals that cannot slip, the product you select makes the difference between clarity and confusion. Our Laurdan stands behind its data sheet, but more importantly, backs up each vial with expert support, deep-running process transparency, and an ongoing drive to adapt and refine. In all our experience, supplying researchers with real tools that live up to their promise means providing more than pure product—we deliver the technical partnership that lets you get to the truth of every sample, every time.