HS Code |
932520 |
| Chemical Name | Imidazoleacetic acid hydrochloride |
| Synonyms | Imidazole-4-acetic acid hydrochloride |
| Cas Number | 22884-12-6 |
| Molecular Formula | C5H7N2O2·HCl |
| Molecular Weight | 178.58 g/mol |
| Appearance | White to off-white crystalline powder |
| Solubility | Soluble in water |
| Melting Point | 220-222°C (dec.) |
| Storage Conditions | Store at 2-8°C, protected from light and moisture |
| Pubchem Cid | 123885 |
As an accredited Imidazoleacetic acid (hydrochloride) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Imidazoleacetic acid (hydrochloride), 25g, is packaged in a sealed amber glass bottle with tamper-evident cap, labeled with supplier details. |
| Shipping | Imidazoleacetic acid (hydrochloride) is shipped in tightly sealed containers to prevent moisture absorption and contamination. It is typically classified as a non-hazardous chemical but requires careful handling. Ensure compliance with local regulations. Packaging is designed to prevent damage during transit and shipment is arranged via reputable carriers, often with tracking for laboratory chemicals. |
| Storage | Imidazoleacetic acid (hydrochloride) should be stored in a tightly closed container, in a cool, dry, and well-ventilated area, away from incompatible substances such as strong oxidizing agents. Keep it protected from moisture and direct sunlight. Store at room temperature (15–25°C), and follow the specific storage guidelines provided by manufacturers such as Sigma Aldrich, Merck, or TCI Chemicals. |
Competitive Imidazoleacetic acid (hydrochloride) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Years of hands-on production and day-to-day problem solving go into producing pure Imidazoleacetic acid (hydrochloride), and the experience offers more than a chemical formula. We see requests come from academic labs, agricultural researchers, and pharmaceutical development teams—each looking for reliability and consistency batch after batch. Models and grades differ across labs, but the demand for a high-purity crystalline hydrochloride stands firm. The compound’s molecular structure—C5H7ClN2O2—combines an imidazole ring with an acetic acid side chain, in a hydrochloride salt to stabilize its solid form and boost its solubility in water.
Chemists ask for the hydrochloride salt rather than the free acid for good reason. In our reactors, free imidazoleacetic acid without the HCl salt form tends to clump, cake, and show inconsistent dissolution. When hydrochloride is present, the resulting material flows cleanly in granulation steps, stores with minimal hygroscopicity changes, and dissolves readily for handling in an aqueous context. That means someone in the lab can weigh, portion, and reconstitute according to protocol, rather than burn time preparing extra stock solutions. Small details in bulk physical stability translate into saved research hours at the bench.
Production of research-grade chemicals has little room for shortcuts. Each order passes through an array of checkpoints: crystallization, drying, purity checks via HPLC and FTIR, and full documentation all the way from raw input to finished jar. The stakes are not abstract. Off-spec byproducts or impurities can upset enzyme reactions, change receptor-binding assays, or alter cell culture results. Pharmaceutical customers often request detailed impurity profiles, not just a purity percentage on a certificate.
Over the years, we have traced problem batches back to batch-to-batch ingredient variability in the starting imidazole or acetic acid. Since we started tracing every incoming lot, matching them to spectral fingerprints, and storing retains for long-term review, error rates dropped sharply. That did mean slower scale-ups early on, but without it, false research leads, failed development projects, and repeat rework orders drove up costs for everyone. Those late-night troubleshooting phone calls softened after this internal discipline took hold.
Imidazoleacetic acid hydrochloride shows up in surprising contexts. Biology groups rely on it as an analogue or mimic during study of histamine breakdown and metabolite tracing. Analytical chemists employ it in calibration standards for metabolic pathway mapping. Drug discovery teams keep it on hand for receptor binding and characterization assays, trying to unravel new signaling targets.
Some fermentation specialists use our material in specific bacterial growth media as a trace-level stimulant or inhibitor. In these cases, trace metals bind differently if the hydrochloride is not fully neutralized, so we go several steps beyond standard heavy metal checks and screen for trace copper, iron, and zinc. Most generic quick-tests would never catch those minor contaminants, but a flagged media prep sets an entire production schedule back days.
Custom requests arise, especially on milligram to kilogram pilot scales for unique buffer formulations or conjugation reactions. Synthetic chemists might tweak downstream synthesis and request finer or coarser granularity. Our milling and sieving lines allow us to tailor material to these requests after a routine spec run, but we always compare post-processing lots to a master reference through both spectroscopic and chromatographic checks.
People new to the compound sometimes ask about the difference between the hydrochloride salt and free acid, or the sodium and potassium salts. Each form has distinct utility, often dictated by process or experiment.
Hydrochloride generally outperforms the free acid in terms of shelf life and solubility. We routinely analyze retention samples over a two-year period, and hydrochloride retains crystal structure and potency with minimal degradation under controlled storage. The free acid, by contrast, absorbs atmospheric moisture and can turn sticky or discolored after only a few months, especially in humid zones or with repeated opening.
Salt form selection often comes down to downstream compatibility. When an assay or process is acid-sensitive, the sodium salt gets nod for neutral buffering or direct feed into base-catalyzed reactions. Most peptide and protein conjugation chemistries, though, tolerate a little extra chloride ion, so hydrochloride finds broader acceptance. In our operation, hydrochloride grades move out the door in far greater volume due to this practical fit.
Some production partners request deuterated variants for tracer work. These require additional synthesis steps and careful monitoring for back-exchange. For the vast majority, standard hydrochloride meets the testing protocols with no drift in performance or unwanted ionic interference.
Manufacturing and shipping often get overlooked in chemical catalogs, but over years of production, those practicalities shape outcomes. Our packaging team has tested dozens of liners, bottles, and seals before dialing in what prevents caking and minimizes static charge. Glass jars offer the best chemical compatibility, but brittle containers rarely survive real-world handling, especially in international transit.
On the warehouse floor, temperature and humidity tracking has taken on more importance as we started working with more projects in equatorial climates. We invest in dual desiccation packs and layered polyethylene liners for drum shipments, since customs search delays sometimes strand product for weeks. We have tracked returned shipments back to packaging failures rather than core material faults, which shaped how we spec bottles and secondary liners for each region.
Feedback from technical customers often spurs us to adjust process steps or overhaul how we prepare and ship products. One major research partner reported recurring static build-up inside their automated dispensing system. Our trials found that a modified antistatic liner plus a finer prepackaged aliquot size solved the issue for future shipments. Small details add up in a lab running around-the-clock screening plates.
Safe production and packaging of any solid or granular acid salt relies not just on written protocols but on practical vigilance. Dust and granular drift must be contained at source, which means our operators wear full protective gear, run batch filters under dedicated hoods, and steadily upgrade extraction controls. Over the years, we have been able to reduce staff exposure fourfold by shifting pelletization steps into enclosed mixers with direct bagging arms.
Our firsthand observation is simple: a careless transfer step or skipped PPE checkpoint results in lingering acid odors and possible irritation for staff. Early incidents led to an internal checklist that would be familiar to anyone who spends a lifetime handling reagents. Most commercial chemical safety standards originate from field experience, documented near-misses, and actual improvements in workplace layout, rather than imposed rules.
Customer safety awareness has grown along with regulatory attention. Some partners ask for detailed handling protocols or safety reference sheets for onsite teams, and we share lessons learned from our own shifts. Good practice passes down through direct dialog and feedback, not just paperwork.
Regulations across the United States, European Union, and Asia each spell out their own lists of compliance requirements. Our lab audits have seen ever-rising scrutiny on impurity thresholds, solvent residues, and even residual catalyst levels. Each year, new checklists force us to upgrade methods or add headspace GC screens for unexpected volatile residues. These demands sharpen technique and build trust, even if they slow throughput.
We observed several years ago that poorly documented syntheses elsewhere led major clients to shift vendors. A certificate of analysis only delivers value when actual process notes, step-by-step chromatography reference checks, and traceability documents match. In our experience, sharing full process docs rather than sanitized synth numbers reassures not just auditors but working chemists as well. Transparency is more than buzzword—it's a daily practice embedded by managers who themselves came up from frontline production roles.
The drive toward sustainable practices affects every chemical manufacturer, but especially those producing crystalline acid salts. We've retooled plant wastewater management to separate acid and neutral salines, reducing total volume and diverting neutral water for facility cleaning instead of disposal. By reclaiming filtered hydrochloric acid from mother liquors and steam stripping rather than sending it to waste, total chloride emissions from our line have dropped over fifty percent in recent years.
Raw material selection also plays a role in final product impact. Lower grade acetates or off-spec imidazole introduce not just variable performance, but waste byproducts requiring additional treatment. By sticking to certified upstream suppliers and fast-tracking impurity checks before production, less off-grade material needs scrapping. The practical payoff shows up in reduced waste disposal costs, steadier environmental reporting, and leaner purchase cycles.
Plant teams continually look for ways to recapture spent solvent or minimize batch mother liquor volumes. While these steps require upfront investment and ongoing maintenance, the cumulative effect shows in inspection reports and in reduced community complaints about odor or accidental discharge risks. We see our environmental credentials not just as a regulatory requirement but as competitive leverage—better process means more consistent supply for customers and a safer footprint for everyone nearby.
Pricing for technical- and research-grade Imidazoleacetic acid hydrochloride fluctuates with global feedstock costs, energy volatility, and transportation bottlenecks. Our finance team monitors global acetic acid and imidazole prices, and we have experienced first-hand the pricing swings when major upstream plants pause for maintenance or when shipping container shortages push freight costs skyward. On-the-ground planning means stockpiling raw materials before major market moves, locking in forward contracts, or even negotiating contingency shipments by air for urgent customer timelines.
Not every lab needs kilogram volumes. Academic groups in particular appreciate smaller, high-purity batches, shipped with complete assay and handling documentation. Our production philosophy maintains dedicated pilot vessels and custom run sheets for these small batches, even when it means a higher per-unit overhead. Many of our past collaborations have begun with a milligram test batch and scaled up through research milestones, which keeps our team focused on flexible support rather than a one-size-fits-all operation.
The fastest growing segment now comes from biotechnology firms—especially those investigating metabolic pathway engineering and receptor pharmacology. The repeatability of biologicals depends on consistent excipient and chemical input quality, and any analytical deviation can invalidate months of cell culture work.
Our team often learns the most from direct collaboration with working scientists, production technologists, and analytic staff in the field. Customization requests, feedback on particle size or wettability, and requests for novel packaging all start with dialog. One group working on large-screen biological assays flagged issues caused by slight variations in batch potency; subsequent rounds of process refinement brought tighter controls and more frequent interim sub-lot testing.
Product evolution rarely comes from theoretical lab work alone. Line workers shape improvements to transfer processes, in-house chemists troubleshoot micro-scale synthesis updates, and plant maintenance crews adapt water handling based on hands-on experience. Together, those insights make each production run a little smoother and the product a bit more reliable for the next project.
Hydrochloride form offers more than just a minor chemical tweak. Stability, ease of handling, improved solubility, and robustness against environmental humidity set it apart from both the free acid and other salts. Our data show fewer reorder delays, more stable assay outcomes, and longer shelf life, all supported by continuous field feedback and internal retention testing.
We produce the hydrochloride for teams that need those attributes. While custom variants serve niche needs, for most applications, the hydrochloride stands out in day-to-day work for anyone needing predictable, high-purity imidazoleacetic acid on the lab bench or the production floor.