HS Code |
667678 |
| Product Name | H-Phe-OtBu·HCl |
| Chemical Name | tert-Butyl (S)-2-phenylglycinate hydrochloride |
| Molecular Formula | C13H20ClNO2 |
| Molecular Weight | 257.76 |
| Appearance | white to off-white crystalline powder |
| Melting Point | 112-116 °C |
| Solubility | soluble in methanol and ethanol, sparingly soluble in water |
| Cas Number | 39027-92-8 |
| Storage Temperature | 2-8 °C |
| Purity | typically >98% |
| Optical Activity | [α]20/D +25.0° (c=1, MeOH) |
| Synonyms | N-Phenylalanyl tert-butyl ester hydrochloride |
As an accredited H-Phe-OtBu·HCl factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | H-Phe-OtBu·HCl is packaged in a 5g amber glass bottle with a screw cap, labeled with product and safety details. |
| Shipping | H-Phe-OtBu·HCl (Sigma Aldrich/Merck/TCI Chemical Grade) is shipped in sealed, moisture-proof containers to preserve product integrity. It is transported under ambient conditions but protected from excessive heat and light. All shipments comply with relevant chemical handling and labeling regulations to ensure safe and secure delivery to laboratories and research facilities. |
| Storage | **H-Phe-OtBu·HCl** (Sigma Aldrich/Merck/TCI, Chemical Grade) should be stored in a tightly sealed container, protected from moisture and light, at 2–8°C (refrigerated). Store in a dry, well-ventilated area away from incompatible substances such as strong oxidizing agents. Follow manufacturer guidelines and local regulations for safe handling and storage. Keep out of reach of unauthorized personnel. |
Competitive H-Phe-OtBu·HCl prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
From decades at the reactor, I see the working world of protected amino acids as one full of choices and trade-offs, right down to seemingly minor differences in protecting groups or salt forms. Among the suite of protected phenylalanines we prepare, H-Phe-OtBu·HCl stands out not for novelty, but for what it delivers consistently in peptide synthesis—an angle sometimes lost in bulk-market catalogs. Its ter-butyl ester makes all the difference during complex couplings.
I remember the early runs where we’d assess yield drift with fluctuating ambient humidity and raw material sources. It takes more than just stoichiometric balances to make H-Phe-OtBu·HCl at a standard you can trust. Raw L-phenylalanine gets transformed through controlled esterification, taken under anhydrous conditions with t-butyl alcohol and acid catalysts, and any slip on moisture control in the initial phase always shows up on the downstream purification or, worse, in customer complaints when they see problem peaks on their chromatograms.
Products like H-Phe-OtBu·HCl rarely come in multiple “models” the way one might expect for manufactured goods, but every lot carries its own identity built out of process integrity. Consistent white crystalline powder, a tidy melting point in the expected range, residual solvent levels always tracked below the regulatory advice—these are real results born out of hands-on process design and patient refinement.
Each batch is brought through precise fractional crystallization and vacuum drying before final testing of purity. Analytical HPLC traces (retention times, symmetry, and the like) mean more to a chemist than marketing buzzwords. Alongside NMR results, spot-checked for possible rotamer presence or unexpected byproducts from incomplete esterification, this gives a real picture of quality that matters in multistep synthesis.
Down the production line, H-Phe-OtBu·HCl finds repeated application in solid-phase peptide synthesis, specifically where the t-butyl group provides robust protection for the C-terminal carboxyl. The hydrochloride salt form brings both stability and a straightforward deprotection profile. Scale-up projects always benefit from the compound’s reliability under both manual and automated assembly, and the dry, free-flowing powder form slides out of containers without the clumping seen in some less-refined grades.
In large runs, the real litmus test is compatibility with modern Fmoc/t-Bu strategy. With H-Phe-OtBu·HCl, phenylalanine residues insert smoothly into elongating chains. The t-butyl group resists side reactions under Fmoc removal conditions (20% piperidine in DMF creates none of the trouble traces you see with less-stable esters), then comes off clean with standard TFA cleavage, allowing for peptides with uncompromised C-terminal integrity. Time after time, batch records show reproducible yields and minimal deletion sequences, even as run sizes scale from gram lab work to kilo lots.
For custom syntheses, H-Phe-OtBu·HCl’s handling properties have real impact. Batch moisture testing—using Karl Fischer titration—not only keeps the process on spec, but reduces hydrolyzed byproduct formation, which directly links to higher peptide purity post-cleavage. Customers often look for reliable scale-up, and that only becomes possible with raw materials that behave the same in a two-gram manual coupling as in a multi-liter vessel. This is where predictable crystallinity and shelf-stability of our product shows its value.
We’ve always believed you can’t take shortcuts in protected amino acid production. Each stage, from the first weigh-in of phenylalanine to the drying steps, leaves its trace in the finished product. Raw materials come from vetted suppliers with tight traceability. Each batch receives close control of t-butyl alcohol quality—we reject any sign of excess peroxides, learning the hard way years ago that trace instability breeds downstream discoloration and side products that won’t clear at the isolation phase.
During the formation of the t-butyl ester, heat and acid conditions are controlled just shy of the levels that could trigger unwanted racemization or over-esterification—waste not only of time, but of active substance. The use of HCl for salt formation usually follows, since hydrochloride form both stabilizes the free amino group (as an amine hydrochloride) and improves the solid’s predictability in storage. We tail each run with focused checks for residual t-butyl chloride and related volatiles, using established headspace GC methods.
Logistics also factor into product performance. The choice of packaging, including moisture barriers and inert gas flush, shields the compound from degradation in transit and storage. Any finish line testing—microbalance for bottle weights, desiccator tests for hygroscopicity—comes not from policy, but from countless small customer lab stories where problems resolved simply by attention paid to these overlooked steps.
Comparing this product to other protected L-phenylalanines comes down to practical syntheses and side reaction avoidance. Alternate protection, like H-Phe-OBzl·HCl (benzyl esters), adds risk of hydrogenolysis sensitivity, especially in sequences containing multiple reducible functionalities. The benzyl group comes off efficiently, but only under hydrogenation that could put other sensitive groups at risk. t-Butyl, contrastingly, offers high orthogonality with Fmoc protection and moves smoothly through TFA-labile cleavage.
Some peptide chemists pick methyl esters for their rapid removal under milder conditions, but our process data reveal that t-butyl ester remains the gold standard for demanding, long-chain peptide builds where stability along the synthesis sequence trumps minor convenience in the final steps. H-Phe-OtBu·HCl blends straightforward removal with high stability during repetitive couplings and wash steps that characterize modern automated synthesizers.
In commercial and academic settings, project timelines depend on the elimination of unplanned troubleshooting. We keep logs on returned samples and customer feedback, and most calls about “unknown peaks” in purity assays traced back to the use of less-protected or non-hydrochloride salt forms where hydrolysis or aminolysis creates mismatched coupling. With H-Phe-OtBu·HCl, these troubleshooting cycles nearly vanish.
Compared to Fmoc-protected Phe derivatives, t-butyl-esterified phenylalanine provides chemists with distinctive flexibility: you can couple this compound directly to peptide resin using either manual solution phase or automated methods, watching as t-butyl keeps its place all the way through the synthesis cycle until the final acidolysis. There’s none of the labor-intensive customized protection/deprotection steps required when using less-selective or dual-protected derivatives.
Over years meeting demand surges, our team has mapped out every pinch point in scaling up t-butyl-protected amino acids. Light, oxygen, and even static electricity sometimes trigger minor parameter shifts—details most outsiders barely consider.
Processing tens of kilos in a run, we favor double-crystallization and gentle vacuum drying—these approaches eliminate persistent microscopic residuals that would otherwise foul large-scale reactors or complicate post-synthesis isolation. Each phase rarely reveals major disasters but small deviations, visible only by analytics, give away where process discipline slipped.
We’ve learned from customer complaints and in-process QCs: the best batches record sub-0.5% water (KF methods), high homogeneity on NMR, and stay well inside the typical 98%+ purity expected in pharmaceutical intermediates. Quality control data gets documented; no product gets released on assumed consistency. Trained eyes on production lines catch clumping or off-odors, both warning signs of unintended decompositions—these batches never ship.
As new synthetic protocols develop in academia, and as peptide drug development grows, research chemists need assurance of compatibility, stability, and reliable reactivity profiles. Users of H-Phe-OtBu·HCl depend on its purity and reactivity for every new sequence trial, lead optimization, or process translation to larger GMP standards. The chemistry we monitor in manufacturing reflects the reality faced daily in peptide labs.
H-Phe-OtBu·HCl manufacturing poses technical difficulties best solved by blending equipment reliability with experienced oversight. For example, erratic moisture levels can ruin entire runs, making humidity controls not optional, but critical. Each time a batch shows lower yield or minor decomposition, production logs and environmental readings help pinpoint causes. Regular, systematic analytics—KF water testing, acid-base titration for free amine, purity by HPLC—let us prevent, rather than just detect, the root of problems.
In application, purification steps after coupling often slow projects. With consistently high-purity starting material, we see researchers trimming hours off post-synthetic purification, eliminating repetitive flash columns, and reducing costly waste. Feedback shows that reliability saves time and supports tighter project timelines, especially evident in fast-paced preclinical projects and pilot peptide manufacturing.
Cold-chain and shelf-life concerns often come up with intermediates like H-Phe-OtBu·HCl. Our response focuses on rapid yet gentle dehydration and robust packaging. Each lot ships with moisture indicator cards, not as pageantry but as a quick reality check for whoever opens the drum, especially in humid regions. This practical approach prevents the compound from absorbing atmospheric water and forming the t-butyl deprotected acid, which complicates downstream coupling.
Many new or smaller synthesis groups lack the full suite of analytical tools to check batch-to-batch quality. To support these labs, we routinely share batch chromatograms, NMR spectra, and water content certificates upon request. Clear transparency around these parameters builds trust and supports process reproducibility outside the big pharma environment.
The story of producing t-butyl-protected amino acids isn’t static. Each year brings new analytical techniques and process optimizations. We calibrate high-sensitivity HPLC detectors to pick up possible contaminants and cross-check sample integrity against reference standards from independent sources. New process monitoring tools alert us to temperature deviations or pressure spikes in real time in the reaction stage, helping us head off rare problems before they show up in downstream purification.
We invest in direct feedback channels with users, regularly collecting notes, reporting any synthesis bottlenecks tied back to raw material stability or purity. Our lab team investigates these reports with targeted micro-scale experiments, using the customer’s real solvent systems and coupling reagents to test compatibility. Information comes from both sides—the benches we run daily, and the ones run by project chemists across the globe.
Sourcing and regulatory challenges also reshape our approach from year to year. Shifts in global raw material supplies mean we run extra analytical profiles with every new vendor batch, alert for changes in optical rotation, impurity loads, or even packaging integrity. This vigilance has saved us from recall headaches more than once.
Market changes, especially tightening regulations on residual solvents and elemental impurities, force continual adaptation. Staying ahead means cross-checking lots with the most up-to-date official methods, whether that’s gas chromatography for volatiles or inductively coupled plasma for heavy metals. While some suppliers cut corners, we take pride in never skipping these steps, no matter the extra cost or time.
For every researcher depending on H-Phe-OtBu·HCl, what comes in the drum sets a boundary for what their work accomplishes. Stringent process control translates into higher coupling yields, fewer purification cycles, and, most vitally, reproducible results. We’ve seen cases where a single off-specification batch led to cascading project delays—lost weeks not only in material replacement but redesigning purification schemes.
Missteps in raw material choice at the protected amino acid stage have downstream impact, from missed preclinical milestones to regulatory headaches in GMP scale-up. Our on-the-ground knowledge—tracking how certain lots behave in real-world syntheses, not just how they appear on paper—lets us adjust and fortify every stage of our process, from breathing new rigor into QC steps to emphasizing unbroken cold-chain transport during the summer surge months.
With the growth of peptide therapeutics and research, demand for high-quality intermediates like H-Phe-OtBu·HCl won’t slow. As batch sizes grow, so does the penalty for lax controls. We spend as much time investigating customer project outcomes as we do our own analytics, bringing every lesson learned back into the next cycle of production. The industry’s shift toward transparency and documentation has shaped our protocols—real batch-to-batch records hold more value than generic data sheets.
The questions that matter to working chemists—does it dissolve cleanly, does it store without degradation, does it give full conversion during coupling—can only be answered through accumulated hands-on manufacturing and follow-through. Every year of producing H-Phe-OtBu·HCl deepens our understanding of the details that separate success from frustration.
Consistent manufacturing of H-Phe-OtBu·HCl depends on direct engagement with both the science and the daily slog of chemical production. We carry forward improvements and discoveries not just from literature, but from the feedback cycles inside every drum shipped and every run tracked on customer reports. Mistakes become lessons, and rare successes become new standards.
Years spent troubleshooting coupling bottlenecks, managing humidity controls, and tuning crystallization protocols bring a real-world credibility that sales pitches rarely touch. Peptide researchers trust us to sweat the small stuff so they can focus on building vital new molecules, diagnostics, and drugs. Respect for the work drives our standards.
Reporting as both manufacturer and problem solver, I see our job as far more than mixing and shipping chemicals. Every refinement to H-Phe-OtBu·HCl production, every adaptation to feedback and new market needs, contributes to the science and industry—building reliability batch after batch, and sparing researchers the costs of unpredictable results.