|
HS Code |
830587 |
| Name | Ganglioside GM1[d18:1, (Carbon-13)C16:0] |
| Molecular Formula | C76H136N2O31 |
| Molecular Weight | 1546.87 g/mol |
| Isotopic Label | Carbon-13 on C16:0 fatty acid chain |
| Lipid Class | Ganglioside |
| Structure Type | Glycosphingolipid |
| Sphingosine Base | d18:1 |
| Fatty Acid | (13C)C16:0 |
| Purity | Typically ≥98% (as per supplier specs) |
| Appearance | White to off-white powder |
| Storage Temperature | -20°C |
| Solubility | Chloroform:Methanol (2:1), water (limited) |
| Cas Number | N/A (isotopically labeled form) |
| Synonyms | 13C-labeled GM1 ganglioside, GM1 [d18:1, (13C)C16:0] |
| Applications | Biochemical research, mass spectrometry standards |
As an accredited Ganglioside GM1[d18:1, (Carbon-13)C16:0] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Ganglioside GM1[d18:1, (Carbon-13)C16:0], Sigma Aldrich, 1 mg, sealed amber glass vial, labeled with lot number and storage conditions. |
| Shipping | Ganglioside GM1[d18:1, (Carbon-13)C16:0] from Sigma Aldrich, Merck, or TCI is typically shipped at low temperatures, often on dry ice, due to its sensitivity. Packaging ensures chemical stability and protection from light. Shipping complies with relevant chemical transport regulations and may require special handling upon arrival. |
| Storage | Ganglioside GM1[d18:1, (Carbon-13)C16:0] should be stored at -20°C, protected from light and moisture, due to its sensitivity to oxidation and degradation. It should be kept in a tightly sealed container, preferably under an inert gas atmosphere. Avoid repeated freeze-thaw cycles, and use within the recommended shelf-life provided by Sigma Aldrich, Merck, or TCI for optimal stability. |
Competitive Ganglioside GM1[d18:1, (Carbon-13)C16:0] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
In our years on the production floor and in the lab, we’ve learned that true value in a chemical compound lies not just in its purity or source material, but in how it fits challenging protocols and research goals. Ganglioside GM1[d18:1, (Carbon-13)C16:0] isn’t an ordinary glycolipid. Over countless batches, reference checks, and feedback cycles with neuroscientists and analytical specialists, we have seen firsthand why precise structural customization like Carbon-13 labeling turns fundamental ganglioside molecules into indispensable research tools.
Standard GM1 gangliosides find frequent use in neuroscience, lipidomics, and cell membrane modeling. Our version, prepared with a d18:1 sphingosine tail and a strict (Carbon-13) labeling on the C16:0 fatty acid, makes a marked difference in experimental workflow and interpretation. The stable isotope label introduces an extra layer of tracing power, key for mass spectrometry and NMR studies where background noise or molecular ambiguity threaten to skew results. Many of the researchers we supply mention how the clear isotopic signature transforms quantification and metabolic tracing, eliminating time spent separating natural isotopic variations from true metabolic events.
While natural GM1 occurs abundantly in mammalian nervous tissue, achieving a labeled variant at usable scale took more than a decade of incremental manufacturing adjustments. The labeling must persist through each production phase—blending, purification, lyophilization—to deliver a molecule that doesn’t show degradation, oxidation, or isotope loss. We have learned to watch for trace impurities and develop robust analytics so each lot’s isotopic enrichment is confirmed and batch reproducibility never wavers. Our own documentation process comes from hundreds of quality control cycles, and neither we nor our clients accept less than reliable isotope content from vial to vial.
We’ve worked with labs peeling apart the molecular traffic of the central nervous system or investigating sphingolipid turnover in neurodegeneration. The demands are exacting. Regular, unlabeled GM1 often leaves important questions unanswered, since it blends into endogenous pools and can’t be followed through metabolic pathways. The (Carbon-13)C16:0 label creates clarity—providing a unique fingerprint so even minor metabolic changes reveal themselves during analysis.
The ganglioside backbone remains biologically active and structurally identical to native compounds, except for the carefully introduced label. That means researchers can run key cell or animal studies without the uncertainty associated with heavily modified probes. Our quality assurance frequently includes collaboration with academic and industrial partners, examining how this molecule performs in live cells, brain slice cultures, or after in vivo administration. Feedback from these collaborations steered us toward higher isotopic enrichment, stricter lipid oxidation controls, and lower pyrogen contamination than typically seen in commodity gangliosides.
As producers, we’ve learned the difference between a batch that just passes and one that yields robust, confident data downstream. Sourcing reliable starting materials presents one of the main challenges—picking suppliers who control for both trace organic impurities and background isotopes. Many processes in the industry don’t safeguard isotope purity since it’s a cost driver, but in this field, even a 1% deviation means skewed results. We have invested in both carbon-13 precursor screening and post-synthesis analysis to guarantee a stable isotopic signal. This level of detail pays off for every end user relying on actionable data.
Chemical synthesis, particularly glycosylation and acyl chain attachment, rarely happens without hiccups. Over time, we optimized reaction conditions, adopting less aggressive reagents while still ensuring linkage fidelity—a necessity, since even subtle side-products interfere with quantification in analytical platforms. We’ve suspended production on multiple occasions to introduce better purification resins or more sensitive chromatography columns. Tight feedback with those using the product led us to refine lyophilization controls to protect the heat- and light-sensitive ganglioside headgroup.
Learning directly from client experiences, we tighten conventional specifications for carbon-13 content and mass spec purity. Some early lots revealed how minor impurities and undetected isotopic scrambling cropped up during long-term storage. Addressing those, we now rely on improved vial sealing and low-temperature logistics, cutting down on unwanted chemical transformations that usually go unnoticed until analysis begins.
In practical work, the value of ganglioside GM1[d18:1, (Carbon-13)C16:0] revolves around two pillars: quantification and metabolic resolution. Researchers in mass spectrometry-driven lipidomics require precise internal standards. Ordinary GM1 doesn't stand out against the complex mix of endogenous brain lipids. The Carbon-13 label delivers an unmistakable trace, letting research teams calculate recovery, turnover, and localization of ganglioside pools with clarity.
In metabolic labeling experiments, non-labeled controls won’t provide the confidence needed to delineate subtle biochemical changes or cell lineage tracing. With our isotopically-labeled molecule, scientists identify uptake, conversion, and breakdown products without cross-talk from naturally-occurring analogs. This exactitude becomes critical in model organism studies where metabolic drift or tissue compartmentalization matters. Pharmacologists and neurobiologists mention how our product shortened analysis cycles and reduced the guesswork compared to non-labeled standards.
Getting precise results doesn’t depend only on the label. We build each batch with membranotropic purity and endotoxin control, factors that influence cellular response and experimental reproducibility. Early versions, made without such strong sterility focus, saw unpredictable signaling in cell cultures. By tweaking our process after customer feedback, we learned to push purity levels and pyrogen clearance well beyond general research standards, protecting sensitive cultures from confounding variables.
Some suppliers offer ganglioside GM1 in its unmodified form or with a range of isotope labels, but the specifics matter. Unlabeled or deuterium-labeled gangliosides usually present spectroscopy challenges since deuterium produces smaller mass shifts, can exchange back to protium in water, and complicates interpretation for certain analytical platforms. Our Carbon-13 labeling on the fatty acid side chain provides a robust, permanent, and unmistakable mass shift, unaffected by solvent conditions or storage.
Some chemical companies favor C18:0 or heterogeneous fatty acid chains, which leads to batch heterogeneity and introduces variability in biophysical and metabolic assays. We adhere to a uniform GM1 species—d18:1 sphingosine and C16:0 fatty acid—mirroring common naturally-occurring variants. This structural fidelity delivers results that translate to endogenous metabolism without channeling data down theoretical or abstract pathways. Our batches avoid mixtures and undefined species, controlling for chain length, degree of isotopy, and headgroup activity.
We’ve fielded comparisons with resellers’ products labeled only at random sites, or containing incompletely labeled pools. In quantification studies, partial labels inflate error margins and render isotope recovery uncertain. By committing to whole-molecule, site-specific Carbon-13 enrichment, we sidestep data ambiguity and permit accurate mass-tracing whether the sample passes through cell lysates, organ homogenates, or complex mass spectrometry environments.
Neuroscience groups seeking insight on GM1 metabolism in neurodegenerative diseases such as Parkinson’s and Huntington’s have built new projects upon the backbone of our labeled GM1. In mouse models or primary cell assays, our compound provides the clear isotopic signal to capture uptake, transport, and clearance—critical endpoints for drug development and mechanistic research. In experiments tracing changes in brain lipid pools after injury or enzyme inhibition, the Carbon-13 signal survives sample prep and instrument noise, opening up previously inaccessible biochemical dynamics.
Pharmaceutical researchers benefit from the control our product offers in kinetic and distribution studies. By spiking tissue extracts or plasma samples with the labeled compound, they precisely measure recovery and drug-lipid interactions, supporting both basic discovery and translation through regulatory pathways. Our large-scale batches support multi-site studies, ensuring data from all labs can be compared without the confounders of batch variation or isotopic dilution.
In cell biology and immunology, researchers often explore GM1’s role in lipid raft formation, receptor modulation, or pathogen interactions. Our Carbon-13 label enables tracing through detergent-resistant membrane fractions and beyond, clarifying how exogenous gangliosides behave relative to endogenous pools. The feedback we receive from collaborative groups often drives minor changes to improve dispersibility and reduce clumping, fine-tuning our process to fit the demands of cutting-edge work.
The field of stable isotope labeling has no shortage of evolving analytical and regulatory demands. Maintaining a consistent, high-purity product means facing unpredictable supplier chain shifts, regulatory updates, and emerging customer technical requirements. We respond by holding deep partnerships with suppliers of both raw ganglioside intermediates and Carbon-13 labeled fatty acids. Frequent auditing and pre-shipment validation keep us ahead of potential disruptions.
Staying current with the needs of globally dispersed research centers challenges our logistics team and cold-chain partners. Tight shipping timelines and temperature-controlled storage guard against moisture uptake, oxidation, and the slow decay of the labeled moiety. Subtle changes in packaging materials, sealing techniques, and shipment routines all stem from continuous improvement to fit ever-more exacting requirements. What started as a rare, custom-synthesized product now forms part of high-throughput screening and international collaborations.
The science behind our ganglioside GM1[d18:1, (Carbon-13)C16:0] continues to push us into technical refinements. We constantly scan the analytical landscape for better QC tools. Advanced HPLC and high-resolution mass spectrometry help us detect impurities or isotopic shifts missed by older techniques. Real-world customer studies reveal the impact of even low-level oxidized side-products or structural isomers, prompting us to bolster every production and analysis phase.
Early in the development of labeled ganglioside products, scaling up production without loss of purity or isotopic consistency caused persistent setbacks. Over time, and with sustained investment in both analytical and process enhancements, we established a stable path for gram-scale production, eliminating batch drift and loss during extended campaigns. This scale-up process lets us deliver larger lots for institutions standardizing lipidomic or tracer analyses across departments or sites.
As environmental and sustainability concerns rise in the chemical manufacturing world, we take active steps to reduce solvent use, optimize precursor recovery, and introduce greener purification technologies. By recycling solvents and minimizing waste during key synthetic steps, we support research progress without burdening laboratories with hidden environmental costs. Our efforts on this front reflect researcher feedback for responsible sourcing and waste management but go beyond by implementing solutions before they become crisis points.
Feedback channels with our customer base remain an important aspect of what we do. Suggestions for changes often flow directly from bench scientists, analytical chemists, or principal investigators who run into new challenges as their protocols advance. This direct engagement leads to iterative improvements—whether introducing traceable QR codes for batch verification, or embedding smarter safety protocols in high-throughput setups. Our team treats each suggestion as an opportunity to increase both product and procedural value.
Throughout our experience producing and supplying Ganglioside GM1[d18:1, (Carbon-13)C16:0], we’ve found that mutual trust between manufacturer and researcher drives progress as much as technical data. Laboratories expect—and deserve—comprehensive transparency about structure, purity, and isotopic enrichment. We share both specifications and data from each batch, adapting reporting standards to fit regulatory and journal requirements as needed. Our documentation goes beyond typical vials and manifests, drawing on real use-case data to help build trust and credibility for each client.
Issues such as data reproducibility and batch-to-batch consistency form key pillars of academic and preclinical lab operations. By focusing on these metrics, with each lot’s measurements tracked and recorded, we protect both the researchers relying on our products and the integrity of their publications or regulatory submissions. In our own development cycles, every deviation or client-reported anomaly prompts a root-cause analysis and team-wide lessons learned, fueling upgrades across the board.
As a team deeply involved in making advanced chemical tools, we stay focused on the research problems our clients confront, not just abstract performance markers. Direct discussion with users reveals shifts in required sophistication—greater isotopic specificity for metabolic flux studies, expanded QC reports for regulatory filings, or finer dispersibility for biological assays. Each trend presents new production hurdles and opportunities to refine both molecule and method.
Ganglioside GM1[d18:1, (Carbon-13)C16:0] isn’t static; its structure and specifications respond to discoveries made by researchers who push beyond current boundaries. Our process incorporates their demands—from adjusted drying protocols to more rigorous light protection and automated batch certification. By cultivating these collaborative ties, we invest in scientific progress and reinforce our commitment to quality over convenience or volume.
Moving forward, we aim to deepen these collaborations, staying at the forefront of the evolving intersection of lipidomics, stable isotope chemistry, and systems biology. Providing a tool like Ganglioside GM1[d18:1, (Carbon-13)C16:0] means remaining agile, willing to upgrade and innovate in the service of breakthrough experiments. Every improvement we make comes from addressing real questions, delivering more than a molecule, but a tested and trusted research partner.