HS Code |
405470 |
| Product Name | Ethyl 2-(2-chloroethoxy)acetate |
| Cas Number | 6309-59-1 |
| Molecular Formula | C6H11ClO3 |
| Molecular Weight | 166.60 |
| Appearance | Colorless to pale yellow liquid |
| Boiling Point | 102-104°C at 15 mmHg |
| Density | 1.154 g/cm3 at 25°C |
| Refractive Index | 1.431-1.433 |
| Purity | Typically ≥98% |
| Flash Point | 98°C |
| Solubility | Slightly soluble in water, soluble in organic solvents |
As an accredited Ethyl 2-(2-chloroethoxy)acetate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Ethyl 2-(2-chloroethoxy)acetate (100 mL) is supplied in an amber glass bottle with a secure screw cap by Sigma Aldrich. |
| Shipping | Ethyl 2-(2-chloroethoxy)acetate is shipped in tightly sealed HDPE bottles or glass containers compliant with hazardous chemical regulations. Packaging ensures stability during transit, with outer cushioning for protection. Standard shipping uses ground or air freight depending on destination and regulatory guidelines. All documentation, including safety data sheets, accompanies the shipment. |
| Storage | Ethyl 2-(2-chloroethoxy)acetate should be stored in a tightly sealed container in a cool, dry, and well-ventilated area, away from direct sunlight, heat, and sources of ignition. Keep away from incompatible substances such as strong oxidizing agents and acids. Store at room temperature (15–25°C) and handle using appropriate personal protective equipment as recommended by Sigma Aldrich, Merck, or TCI. |
Competitive Ethyl 2-(2-chloroethoxy)acetate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every bottle of ethyl 2-(2-chloroethoxy)acetate in our warehouse tells a story about careful process management, firm standards, and a direct understanding of what customers downstream look for in a specialty chemical. In the daily work of chemical synthesis, clients want more than a chemical with a long name and a complex formula. They want a product that has proven its worth in practice. Here, in our own production workshops, this molecule earns its purpose batch by batch.
Producing ethyl 2-(2-chloroethoxy)acetate takes more than just reactors and raw materials. Our team manages the reaction sequence down to the details—temperature, pH, and reactant concentrations get tracked and adjusted in real time. The raw material sourcing, often centered on chloroethanol and ethyl glycolate, drives the foundation of purity from the outset. On the shop floor, reaction consistency stands at the center of our output. Our staff take pride in catching problems early, making timely adjustments, and recording every batch for traceability.
Specifications are not just numbers on a sheet. We check GC purity above 99%, but just as often we smell, observe, and touch—checking for color, visible residue, or odd odor that signals an outlier. Each bottle comes with a certificate, but it is the in-facility, hands-on checks that matter the most. It all leads to a pale yellow liquid that moves smoothly through normal handling, with specific gravity and acid value maintained where downstream syntheses won’t go off target.
Batch chemistry involves more than formulas—it’s about reliability. Our regular customers make products such as pharmaceutical intermediates, crop protection agents, and fine chemical additives. They want to skip re-purification and move the workflow forward. If the purity drops even half a percentage point, or water content creeps up unseen, the entire value chain slows. Acetyl chloride contamination, for instance, causes chain reactions nobody wants to troubleshoot. We keep moisture below 0.1% because those few stray water molecules can quench a reaction downstream, forcing retesting and delays.
As a manufacturer, feedback from steady partners means more than any brochure. Over the past decade, clients from the API (active pharmaceutical ingredient) industry rarely complain about failed reactions when using our material. They’ve cut back on extra distillation because water and acid content land inside a range even with sensitive intermediates. From the plant manager’s point of view, that means fewer emergency calls and night shifts spent investigating batch failures.
Over time, our site has shipped ethyl 2-(2-chloroethoxy)acetate to a range of users who run reactions for both development and regular production. While textbooks list it under “halogenated esters,” customers find real value in its role as a versatile ether-ester building block. Its chemical structure, with the chloro handle at the end of an ethoxy chain, makes it a prime tool in nucleophilic substitution reactions.
One major group of users comes from pharmaceutical manufacturing. They rely on predictable reactivity—this compound lets them create active compounds where the chloro group can be substituted precisely with amines, thiols, or other nucleophiles. Each batch gets turned into something more complex, whether for beta-blocker intermediates or new testing compounds in drug discovery.
Agricultural chemistry companies also source this molecule for transformations leading to new herbicides. In their hands, the compound gets converted by SN2 reactions into new ethers, thioethers, or amines. Their chemists demand stability—decomposition or hydrolysis cannot sneak in. So moisture and trace acid, possible if purification skips a step, get cut off early in our process.
Fine chemical groups and research labs apply our product as a linker, building up sidechains in polymers or modifying delicate alcohols without risk of rearrangement. The absence of interfering by-products and side isomers gives these researchers better NMR spectra and reproducibility. If their synthesis fails, they want to blame their own procedure, not a mistake from upstream.
From our perspective, ethyl 2-(2-chloroethoxy)acetate stands apart among halogenated esters for the way it balances stability and reactivity. We’ve handled plenty of alternatives—methyl, propyl, and isopropyl variants, as well as longer-chain analogs—but not all show the same combination of liquid state at room temperature, manageable volatility, and clean reactivity.
Methyl variants turn out to be more volatile and, in practice, often lead to more evaporation loss during vacuum transfer. Their shorter chain makes the molecule less flexible in synthesis, especially for introducing more tailored ether functions. Propyl or higher alkyl esters, on the other hand, show sluggish reactions—demanding longer run times, more catalyst, or higher temperatures. That means higher raw energy use on our floor, and trouble for clients who need to manage thermal budgets in their equipment. Isopropyl and tertiary esters, with their bulkier groups, do not offer the same clean SN2 reactivity and leave more residue on removal.
From a storage and handling perspective, ethyl 2-(2-chloroethoxy)acetate remains manageable. Drums keep sealed tight for months, handling crews report no pressure build-up or loss in purity. This acts as a relief in facilities where dust, airflow, and humidity shift with the seasons. Compare that to more aggressive halides or esters prone to hydrolysis—they often require stricter ventilation and more frequent QC, which means manpower tied up in monitoring rather than production.
Handling halogenated esters brings daily attention to detail. Everyone in our factory wears protective gear, and we store this chemical under controlled temperature to avoid unplanned releases or pressure build-up. Usually, we keep it between 5°C and 25°C, minimizing possible breakdown.
Our QC lab runs standard tests for residual acids and chloride content. These steps are not box-checking. Elevated acid content corrodes metal lines; stray chloride can trigger side reactions further down the line. Waste disposal gets tracked by batch and logged daily to comply with local and national standards, including waste code matching and pH readings prior to neutralization.
Worker feedback shapes improvements. A few years ago, transfer lines clogged due to trace polymerization—so we reworked the process, lowered transfer temperatures, and switched some equipment to PTFE-lined tubing to avoid trace catalytic effects of metal pipes. This hands-on approach—born from practical challenge, not a data sheet—is what keeps our batches steady and our workers healthier.
Regular internal audits pick up safety issues before they turn into problems. During plant shutdown seasons, our team reviews storage buffer times, pipe integrity, and batch records to prevent leaks or cross-contamination. Over time, these routines show up as shorter downtime and fewer hazardous waste emergencies.
Daily production keeps us close to challenges—both technical and operational. Raw material prices do not always stay flat, and supply-chain slowdowns test our ability to keep the plant humming. We do not keep problems secret. For example, a regional supplier once delivered chloroethanol with minor off-specs. Our incoming QC flagged it after a minor spike in acid content on incoming batches. Addressing this quickly, by adding extra pre-filtration and reaching out to source a replacement supply, helped avoid what could have been weeks of scrapped output.
Customers—especially those with critical pharmaceutical projects—value honesty about disruptions and recovery. We keep transparency as a core part of how we communicate batch timelines, with regular reporting and updates as soon as shipment or production slowdowns look possible.
Reactor maintenance, often overlooked, forms another piece of our day-to-day. Pumps, valves, and seals degrade when dealing with halogen-rich feedstocks. Our on-site technicians track minor leaks during the production run and execute repairs quickly, relying more on on-hand expertise than outside contractors. This stands as the only way to ensure unwanted downtime remains rare.
Our plant’s waste treatment team carries just as much responsibility. Byproducts—minor alcohols, esters, and trace halides—must be neutralized before wastewater discharge. Following consistent distillation profiles and maximizing batch recovery trims down what reaches the neutralization tanks. This tight control allows us to consistently pass independent wastewater spot-checks, year in and out.
As one of the few actual producers, we receive direct market signals—pricing pressure for both high-purity batches and larger orders. Customer inquiries sometimes cite trader or broker pricing that seems out of touch with actual manufacturing cost. We welcome these conversations. It’s better for buyers to understand what goes into making a product from the source: reaction conditions, labor, purification, and compliance.
Bulk discounts happen only when batch scheduling and raw material stocks line up. On the other hand, priority for on-spec batches means lead time gets attention. By keeping client communication direct and bypassing resellers, our commercial staff spot corners where lead times can be cut without lowering technical standards or worker safety.
Transparency about cost—the direct result of energy input, raw feedstock quality, and regulatory compliance—lets us keep business partners in the loop. This builds longer, steadier relationships and fewer last-minute surprises during price hikes or raw material shortages.
Our R&D division hinges on direct feedback from users’ labs and plants. We know not every synthesis uses the default ethyl chain—specialty users ask about propyl or butyl ethers, about the replacement of the chloro handle with bromo or iodo analogs, or about alternate ester groups for targeted reactivity. Direct discussions with lead chemists often reveal process-specific bottlenecks, prompting us to trial new purification columns, tweak phase-separation steps, or scale test runs based on their feedback.
Tighter impurity standards for regulated markets, such as those needing European or US regulatory filings, motivate us to keep batch impurity tracking record by record. Experiments with milder drying agents, new filtration protocols, or continuous reaction systems attract in-house engineers. These projects arise directly from market reality—not copy-paste industry trends.
In response to environmental regulations, staff at our plant evaluate green solvent recovery. Trials to recycle extraction solvents, move away from chlorinated process agents in cleaning, and automate pH tracking have taken root these past two years. These changes reflect plant-floor input rather than top-down mandates, and often lead to efficiency gains that cut both waste and cost.
Feedback does not just travel one way. Over the past few years, a customer developing anti-infective agents shared an issue with minor side reactions caused by trace formaldehyde in a competing batch from an outside supplier. Our internal batch records showed no such contaminant, but to reassure them, we adopted added screening and provided detailed chromatograms with every delivery for six months. Afterward, their chemists reported fewer failed syntheses and tighter final product quality.
Our own shift managers share similar stories when a procedural step catches a usually rare impurity or moisture ingress. At one point, we had to pause batch release for a local agrochemical customer after a thermal control issue created an impurity spike. Our team flagged it, pulled the whole batch, then reprocessed the next run with stricter input checks and temperature holds. The result: a cleaner, more stable intermediate for the client and a short time-out to protect end-use quality.
This cycle—problem spotted, solution tested, outcome tracked—shapes the product and the habits of those who make it. The upshot for downstream users: better trust, fewer bottlenecks, and a smoother pathway through their own production lines.
In daily operations, a product like ethyl 2-(2-chloroethoxy)acetate means something more than a line entry on a purchase order. It becomes a test of whether a producer meets the standard that customers quietly expect, across all those small but important details—batch after batch.
Our role as the originator, not as an agent or middleman, brings a unique perspective. Every order, every feedback note, every laboratory result carries weight and shapes what leaves our gates. External audits, customer visits, and repeat orders signal trust we do not take lightly. Instead of chasing buzzwords, our team chases every gram of impurity out of the door, every stray droplet of water from the drum.
Looking forward, we keep the doors open to custom requests, process fine-tuning, and tighter reporting to meet new challenges in regulation, scale-up, or specialty use. Direct conversations with chemists, engineers, and production managers—across pharmaceuticals, agrochemicals, and specialty intermediates—keep the focus where it belongs: on a chemical that not only meets its numbers, but fits seamlessly into the working world beyond the plant.